• Title/Summary/Keyword: Acceptable criteria

Search Result 272, Processing Time 0.024 seconds

Analysis of Glass Bottle using Glass Bottle Lightness Index (유리병 경량화 지수를 이용한 유리병 포장용기 분석)

  • Kim, Sun-Jong;Jang, Si-Hoon;Kim, Ki-Tae;Lee, Yu-Suk;Park, Su-Il
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.19 no.2
    • /
    • pp.109-115
    • /
    • 2013
  • Glass bottle lightness index has been used as a guideline for the lightness of glass bottle. In this study, we developed a glass bottle lightness index (L) by modifying Emhart's lightness index. Domestic and foreign glass bottle products were collected in Korean market and classified into two groups, returnable bottle and one way glass bottle. Emptied glass bottle weight and volume were measured and written product's content volume were recorded to calculate the L value. Based on L value, 'acceptable' and 'optimum' criteria for design guideline of glass bottle were established for both returnable and one way glass bottles. Many of one way glass bottles failed to meet acceptable criteria (L=1.0), while returnable glass bottles mostly satisfied acceptable range (L=1.4). Few of one way glass bottles were even heavier than returnable glass bottles. Generally lightness index (L) of small size drink glass bottles (100 ml) were above 1.0, while these of juice glass bottles (180 ml) were close to acceptable criteria. Most foreign sauce glass bottles met the acceptable level, however most domestic souse glass bottles failed to satisfy acceptable criteria. A few foreign beer glass bottles satisfied optimum criteria, while most domestic beer glass bottles were acceptable level. Our results reveal that domestic glass bottles are mostly heavier than foreign glass bottles. In this paper, we suggest the use glass bottle lightness index as a design guideline for material resource reduction of glass bottle for Korean food and beverage industries.

  • PDF

Determination of Adequate Solder Volume using 3D Solder Joint Configuration in SMT (3차원 납 접합부 형상을 이용한 표면실장기술의 적정 납량 결정)

  • 최동필;김성관;유중돈
    • Journal of Welding and Joining
    • /
    • v.14 no.2
    • /
    • pp.71-78
    • /
    • 1996
  • In order to rpovide proper SMT design criteria in a systematic way, a mathematical formulation has been developed to predict the configuration of the solder fillet formed between the gullwing type lead and rectangular pad. Effects of SMT design parameters such as the solder volume and pad dimension on the solder profile are investigated using the FEM that calculates the 3D configuration by minimizing the energy due to surface tension and gravity in the equilibrium state. Design criteria of QFP and SOP are illustrated by plotting the acceptable range of the solder volume with respect to the length and width ratios of the pad and lead. The results show that the acceptable design range increases with increase in the pad length and width. The pad length has more significant effects on design criteria compared with the pad width, and Bond number can be utilized to predict the joint quality.

  • PDF

Risk Assessement-Safety for Rand use Planning (Risk Assessement를 통한 土地利用安全化計劃)

  • Roh, Sam-Kew
    • Journal of the Korean Society of Safety
    • /
    • v.3 no.2
    • /
    • pp.17-23
    • /
    • 1988
  • Planning controls for the hazardous situation from Petrochemical Complexes in residential areas requires on theoretical estimation of risks. Engineering criteria and standards should e interpreted as acceptable risks for the safety of industrial workers and the community arising from industrial accident. An approach to formulate a safety criteria as distance between the origin and object of hazards and their impact are discussed.

  • PDF

Evaluation on Seismic Capacity of reinforced Concrete Structure Based on Structural Testing (구조실험을 통한 철근콘크리트구조의 내진성능 평가)

  • 서수연
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.308-318
    • /
    • 2000
  • This paper introduces the acceptance criteria for reinforced concrete moment frames based on structural testing of ACI in preparing and proposes criteria for acceptable limiting drift and energy dissipation ratios of reinforced concrete shear walls for structural testing. Limiting drift and energy dissipation ratios were examined for tests on shear walls having ductile type failures. Test data were analyzed and compared to results for a suggested acceptance criteria that involves a limiting drift that is a function of aspect ratio a limiting energy dissipation ratio that is a function of displacement ductility and damping.

  • PDF

Proposed Performance Criteria and Evaluation Procedures for Transmission System Planning in Korea

  • Kook, Kyung-Soo;Kim, Taihyun;Oh, Tae-Kyoo;Bang, Min-Jae
    • KIEE International Transactions on Power Engineering
    • /
    • v.2A no.4
    • /
    • pp.160-165
    • /
    • 2002
  • This paper describes a proposed performance criteria and evaluation procedures for transmission system planning in Korea. Performance criteria of the transmission system are expected to be used as a guideline for investment into a transmission network. Moreover, performance evaluation procedures, which are based on current practices and widely accepted theories, are suggested to achieve fair and acceptable results.

Market-Based Transmission Expansion Planning Under Uncertainty in Bids by Fuzzy Assessment

  • Kamyab, Gholam-Reza;Fotuhi-Firuzabad, Mahmood;Rashidinejad, Masoud
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.468-479
    • /
    • 2012
  • In this paper, by a simple example it is shown that existing market-based criteria alone cannot completely and correctly evaluate the transmission network expansion from market view. However criteria congestion cost (CC) and social welfare (SW) together are able to correctly evaluate transmission network from market view and so they are adopted for the market-based transmission expansion planning. To simply indicate the limits of CC and SW social welfare percentage (SWP) and congestion cost percentage (CCP) are defined. To consider uncertainty in bids of market producers and consumers, and also indeterminacy in the acceptable boundaries of the SWP and CCP and their priorities, fuzzy assessment approach is used. In this approach, appropriate fuzzy sets and a fuzzy rule base are provided to evaluate the acceptability of an expansion plan. Then, the least-investment cost plan, which is acceptable in all probable scenarios, is searched. The proposed method is applied to an 8-bus system.

Case Study : Application of Specific Evaluation Criteria For Safety Circuit Design of EN ISO 13849-1 (사례 연구 : EN ISO 13849-1의 안전회로 설계를 위한 구체적 평가 기준의 적용)

  • Jung, Hwansuk;Lee, Dongju
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.1
    • /
    • pp.94-101
    • /
    • 2018
  • With the development of industrial technology and science, production and manufacturing facilities have been enhanced and improved, and the importance of the safety of workers has also been regulated and limited by various safety management methods. As a way to secure the safety of the workers from the production facility, the fail-safe and fool-proof methods are now being applied. Any possible insecure behavior and unsafe conditions can be removed by adopting the standards and specifications that are now secure the safety of workers and equipment. This research analyzes EN ISO 13849-1 international and European standards during CE certification. In order to secure acceptable reduced risks, the risk assessment process of ISO 12100 and the processes for reducing its risk are applied. In the current ISO 13849-1 standard, the criteria for the required performance level PLr (Required Performance Level) for the applicable risk and safety functions through the risk assessment are subjective and not subdivided. Therefore, the evaluation criteria are likely to cause judge's judgement error due to qualitative judgement. This research focuses on evaluation and acceptable performance level setting for the safety circuit of the equipment. We propose an objective and specific evaluation criteria to secure safety, and the proposed evaluation criteria are applied to the case study of the safety circuit for the equipment. In order to secure the safety of the entire safety circuit, the improvement of the MTTFd and DC level related to the SRP/CS (Safety-Related Parts of Control Systems)' lifetime is required for the future research.

Seismic performance of a building base-isolated by TFP susceptible to pound with a surrounding moat wall

  • Movahhed, Ataallah Sadeghi;Zardari, Saeid;Sadoglu, Erol
    • Earthquakes and Structures
    • /
    • v.23 no.1
    • /
    • pp.87-100
    • /
    • 2022
  • Limiting the displacement of seismic isolators causes a pounding phenomenon under severe earthquakes. Therefore, the ASCE 7-16 has provided minimum criteria for the design of the isolated building. In this research the seismic response of isolated buildings by Triple Friction Pendulum Isolator (TFPI) under the impact, expected, and unexpected mass eccentricity was evaluated. Also, the effect of different design parameters on the seismic behavior of structural and nonstructural elements was found. For this, a special steel moment frame structure with a surrounding moat wall was designed according to the criteria, by considering different response modification coefficients (RI), and 20% mass eccentricity in one direction. Then, different values of these parameters and the damping of the base isolation were evaluated. The results show that the structural elements have acceptable behavior after impact, but the nonstructural components are placed in a moderate damage range after impact and the used improved methods could not ameliorate the level of damage. The reduction in the RI and the enhancement of the isolator's damping are beneficial up to a certain point for improving the seismic response after impact. The moat wall reduces torque and maximum absolute acceleration (MAA) due to unexpected enhancement of mass eccentricity. However, drifts of some stories increase. Also, the difference between the response of story drift by expected and unexpected mass eccentricity is less. This indicates that the minimum requirement displacement according to ASCE 7-16 criteria lead to acceptable results under the unexpected enhancement of mass eccentricity.

A DECISION-MAKER CONFIDENCE LEVEL BASED MULTI-CHOICE BEST-WORST METHOD: AN MCDM APPROACH

  • SEEMA BANO;MD. GULZARUL HASAN;ABDUL QUDDOOS
    • Journal of applied mathematics & informatics
    • /
    • v.42 no.2
    • /
    • pp.257-281
    • /
    • 2024
  • In real life, a decision-maker can assign multiple values for pairwise comparison with a certain confidence level. Studies incorporating multi-choice parameters in multi-criteria decision-making methods are lacking in the literature. So, In this work, an extension of the Best-Worst Method (BWM) with multi-choice pairwise comparisons and multi-choice confidence parameters has been proposed. This work incorporates an extension to the original BWM with multi-choice uncertainty and confidence level. The BWM presumes the Decision-Maker to be fully confident about preference criteria vectors best to others & others to worst. In the proposed work, we consider uncertainty by giving decision-makers freedom to have multiple choices for preference comparison and having a corresponding confidence degree for each choice. This adds one more parameter corresponding to the degree of confidence of each choice to the already existing MCDM, i.e. multi-choice BWM and yields acceptable results similar to other studies. Also, the consistency ratio remained low within the acceptable range. Two real-life case studies are presented to validate our study on proposed models.

Floor impact sound classification and setting Acceptable limit based on psychoacoustical evaluation (감성평가 기반 바닥충격음 등급화 및 수인한도 설정)

  • Kim, Sung Min;Hong, Joo Young;Jeon, Jin Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.7-9
    • /
    • 2014
  • An auditory experiment was conducted to establish annoyance criteria for floor impact noise in apartment buildings. Heavyweight floor impact sounds were recorded using an impact ball; the impact sound pressure level (SPL) together with the temporal decay rate (DR), which is quantified by the dB drop per second, was analyzed. For the experiment, A-weighted exposure levels of the heavy-weight floor impact sounds ranging 34~73 dB were evaluated at 3 dB intervals. Participants used a 7-point verbal scale to evaluate the level of annoyance from floor impact noise. The results show that the annoyance increases with increasing impact SPL and decreasing DR. Consequently, a classification and an acceptable level of floor impact sounds were proposed.

  • PDF