• Title/Summary/Keyword: Accelerator

Search Result 1,926, Processing Time 0.031 seconds

Plasma Cosmetic Container Suitability (플라즈마 화장품 용기 적합성)

  • Ha Hyeon Jo;You-Yeon Chun;Hyojin Heo;Sang Hun Lee;Lei Lei;Ye Ji Kim;Byeong-Mun Kwak;Mi-Gi Lee;Bum-Ho Bin
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.50 no.1
    • /
    • pp.59-65
    • /
    • 2024
  • For plasma cosmetics, it is important to ensure the long-term stability of plasma in the formulation. This study examined the suitability of containers for efficient plasma cosmetics development. By varying the surface area covered by the plasma, 4 cm2, 25 cm2, 75 cm2, and 175 cm2 containers were injected with cosmetic plasma, and the amount of nitric oxide (NO), the main active species of nitrogen plasma, was analyzed. As a result, the surface area and stability exposed to plasma tended to be inversely proportional, and it was most effective in a 4 cm2 container. Furthermore, 25 mm, 40 mm, and 50 mm vials were treated with plasma, which resulted in relative long-term stability of NO at 25 mm, a smaller surface area of the container exposed to air. Water mist and stratified mist were selected as cosmetic formulations, and NO plasma was injected into the water layer to observe the changes in formulation properties and the state of the injected NO plasma. In both formulations, the amount of NO plasma injected was about 1.5 times higher in the water phase mist than in the stratified mist, and the stratified mist gradually decreased with time and was found to disappear after 3 weeks. The stability of the nitrogen plasma was studied at low temperature (4 ℃), room temperature (25 ℃), and high temperature (37 ℃, 50 ℃). As a result, it was found that the water mist did not affect the stability, but the stratified mist observed a color change in the oil phase layer. Overall, this study demonstrates the container suitability of nitrogen plasma and suggests the importance of ensuring the stability of injected nitrogen plasma in cosmetic formulations.

LINAC-based Stereotactic Radiosurgery for Meningiomas (수막종에 대한 선형가속기형 정위방사선수술)

  • Shin Seong Soo;Kim Dae Yong;Ahn Yong Chan;Lee Jung Il;Nam Do-Hyun;Lim Do Hoon;Huh Seung Jae;Yeo Inhwan J;Shin Hyung Jin;Park Kwan;Kim BoKyoung;Kim Jong Hyun
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.87-94
    • /
    • 2001
  • Purpose : To evaluate the role of LINAC-based stereotactic radiosurgery (SRS) in the management of meningiomas, we reviewed clinical response, image response, neurological deficits for patients treated at our institution. Methods and materials : Between February 1995 and December 1999, twenty-six patients were treated with SRS. Seven patients had undergone prior resection. Nineteen patients received SRS as the initial treatment. There were 7 male and 19 female patients. The median age was 51 years (range, $14\~67\;years$). At least one clinical symptom presented at the time of SRS in 17 patients and cranial neuropathy was seen in 7 patients. The median tumor volume was $4.7\;cm^3\;(range,\;0.7\~16.5\;m^3)$. The mean marginal dose was 15 Gy (range, $10\~20\;Gy$), delivered to the $80\%$ isodose surface (range, $46\~90\%$). The median clinical and imaging follow-up periods were 27 months (range, 1-71 months) and 25 months (range, $1\~52\;months$), respectively. Results : Of 14 patients who had clinical follow-up of one year or longer, thirteen patients $(93\%)$ were improved clinically at follow-up examination. Clinical symptom worsened in one patient at 4 months after SRS as a result of intratumoral edema, who underwent surgical resection at 7 months. OF 14 patients who had radiologic follow-up of one year or longer, tumor volume decreased in 7 patients $(50\%)$ at a median of 11 months (range, $6\~25\;months$), remained stable in 6 patients $(43\%)$, and increased in one patient $(7\%)$, who underwent surgical resection at 44 months. New radiation-induced neurological deficits developed in six patients $(23\%)$. Five patients $(19\%)$ had transient neurological deficits, completely resolved by conservative treatment including steroid therapy. Radiation-induced brain necrosis developed in one patient $(3.8\%)$ at 9 months after SRS who followed by surgical resection of tumor and necrotic tissue. Conclusions : LINAC-based SRS proves to be an effective and safe management strategy for small to moderate sized meningiomas, inoperable, residual, and recurrent, but long-term follow-up will be necessary to fully evaluate its efficacy. To reduce the radiation-induced neurological deficit for large size meningioma and/or in the proximity of critical and neural structure, more delicate treatment planning and optimal decision of radiation dose will be necessary.

  • PDF

Postoperative Radiation Therapy for Chest Wall Invading pT3N0 Non-small Cell Lung Cancer: Elective Lymphatic Irradiation May Not Be Necessary (흉벽을 침범한 pT3N0 비소세포폐암 환자에서 수술 후 방사선치료)

  • Park, Young-Je;Ahn, Yong-Chan;Lim, Do-Hoon;Park, Won;Kim, Kwan-Min;Kim, Jhingook;Shim, Young-Mog;Kim, Kyoung-Ju;Lee, Jeung-Eun;Kang, Min-Kyu;Nam, Hee-Rim;Huh, Seung-Jae
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.253-260
    • /
    • 2003
  • Purpose: No general consensus has been reached regarding the necessity of postoperative radiation therapy (PORT) and the optimal techniques of its application for patients with chest wall invasion (pT3cw) and node negative (NO) non-small cell lung cancer (NSCLC). We retrospectively analyzed the PT3cwN0 NSCLC patients who received PORT because of presumed inadequate resection margin on surgical findings. Materials and Methods: From Aug. 1994 till June 2000, 21 pT3cwN0 NSCLC patients received PORT at Samsung Medical Center; all of whom underwent curative on-bloc resection of the primary tumor plus the chest wall and regional lymph node dissection. PORT was typically stalled 3 to 4 weeks after operation using 6 or 10 MV X-rays from a linear accelerator. The radiation target volume was confined to the tumor bed plus the immediate adjacent tissue, and no regional lymphatics were included. The planned radiation dose was 54 Gy by conventional fractionation schedule. The survival rates were calculated and the failure patterns analyzed. Results: Overall survival, disease-free survival, loco-regional recurrence-free survival, and distant metastases-free survival rates at 5 years were 38.8$\%$, 45.5$\%$, 90.2$\%$, and 48.1$\%$, respectively. Eleven patients experienced treatment failure: six with distant metastases, three with intra-thoracic failures, and two with combined distant and intra-thoracic failures. Among the five patients with intra-thoracic failures, two had pleural seeding, two had in-field local failures, and only one had regional lymphatic failure in the mediastinum. No patients suffered from acute and late radiation side effects of RTOG grade 3 or higher. Conclusion: The strategy of adding PORT to surgery to improve the probability, not only of local control but also of survival, was justified, considering that local control was the most important component in the successful treatment of pT3cw NSCLC patients, especially when the resection margin was not adequate. The incidence and the severity of the acute and late side effects of PORT were markedly reduced, which contributed to improving the patients' qualify of life both during and after PORT, without increasing the risk of regional failures by eliminating the regional lymphatics from the radiation target volume.

Assessment for the Utility of Treatment Plan QA System according to Dosimetric Leaf Gap in Multileaf Collimator (다엽콜리메이터의 선량학적엽간격에 따른 치료계획 정도관리시스템의 효용성 평가)

  • Lee, Soon Sung;Choi, Sang Hyoun;Min, Chul Kee;Kim, Woo Chul;Ji, Young Hoon;Park, Seungwoo;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.168-177
    • /
    • 2015
  • For evaluating the treatment planning accurately, the quality assurance for treatment planning is recommended when patients were treated with IMRT which is complex and delicate. To realize this purpose, treatment plan quality assurance software can be used to verify the delivered dose accurately before and after of treatment. The purpose of this study is to evaluate the accuracy of treatment plan quality assurance software for each IMRT plan according to MLC DLG (dosimetric leaf gap). Novalis Tx with a built-in HD120 MLC was used in this study to acquire the MLC dynalog file be imported in MobiusFx. To establish IMRT plan, Eclipse RTP system was used and target and organ structures (multi-target, mock prostate, mock head/neck, C-shape case) were contoured in I'mRT phantom. To verify the difference of dose distribution according to DLG, MLC dynalog files were imported to MobiusFx software and changed the DLG (0.5, 0.7, 1.0, 1.3, 1.6 mm) values in MobiusFx. For evaluation dose, dose distribution was evaluated by using 3D gamma index for the gamma criteria 3% and distance to agreement 3 mm, and the point dose was acquired by using the CC13 ionization chamber in isocenter of I'mRT phantom. In the result for point dose, the mock head/neck and multi-target had difference about 4% and 3% in DLG 0.5 and 0.7 mm respectively, and the other DLGs had difference less than 3%. The gamma index passing-rate of mock head/neck were below 81% for PTV and cord, and multi-target were below 30% for center and superior target in DLGs 0.5, 0.7 mm, however, inferior target of multi-target case and parotid of mock head/neck case had 100.0% passing rate in all DLGs. The point dose of mock prostate showed difference below 3.0% in all DLGs, however, the passing rate of PTV were below 95% in 0.5, 0.7 mm DLGs, and the other DLGs were above 98%. The rectum and bladder had 100.0% passing rate in all DLGs. As the difference of point dose in C-shape were 3~9% except for 1.3 mm DLG, the passing rate of PTV in 1.0 1.3 mm were 96.7, 93.0% respectively. However, passing rate of the other DLGs were below 86% and core was 100.0% passing rate in all DLGs. In this study, we verified that the accuracy of treatment planning QA system can be affected by DLG values. For precise quality assurance for treatment technique using the MLC motion like IMRT and VMAT, we should use appropriate DLG value in linear accelerator and RTP system.

Dosimetric Effect on Selectable Optimization Parameters of Volumatric Modulated Arc Therapy (선택적 최적화 변수(Selectable Optimization Parameters)에 따른 부피적조절회전방사선치료(VMAT)의 선량학적 영향)

  • Jung, Jae-Yong;Shin, Yong-Joo;Sohn, Seung-Chang;Kim, Yeon-Rae;Min, Jung-Wan;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.15-25
    • /
    • 2012
  • The aim of this study is to evaluate plan quality and dose accuracy for Volumetric Modulated Arc Therapy (VMAT) on the TG-119 and is to investigate the effects on variation of the selectable optimization parameters of VMAT. VMAT treatment planning was implemented on a Varian iX linear accelerator with ARIA record and verify system (Varian Mecical System Palo Alto, CA) and Oncentra MasterPlan treatment planning system (Nucletron BV, Veenendaal, Netherlands). Plan quality and dosimetric accuracy were evaluated by effect of varying a number of arc, gantry spacing and delivery time for the test geometries provided in TG-119. Plan quality for the target and OAR was evaluated by the mean value and the standard deviation of the Dose Volume Histograms (DVHs). The ionization chamber and $Delta^{4PT}$ bi-planar diode array were used for the dose evaluation. For treatment planning evaluation, all structure sets closed to the goals in the case of single arc, except for the C-shape (hard), and all structure sets achieved the goals in the case of dual arc, except for C-shape (hard). For the variation of a number of arc, the simple structure such as a prostate did not have the difference between single arc and dual arc, whereas the complex structure such as a head and neck showed a superior result in the case of dual arc. The dose distribution with gantry spacing of $4^{\circ}$ was shown better plan quality than the gantry spacing of $6^{\circ}$, but was similar results compared with gantry spacing of $2^{\circ}$. For the verification of dose accuracy with single arc and dual arc, the mean value of a relative error between measured and calculated value were within 3% and 4% for point dose and confidence limit values, respectively. For the verification on dose accuracy with the gantry intervals of $2^{\circ}$, $4^{\circ}$ and $6^{\circ}$, the mean values of relative error were within 3% and 5% for point dose and confidence limit values, respectively. In the verification of dose distribution with $Delta^{4PT}$ bi-planar diode array, gamma passing rate was $98.72{\pm}1.52%$ and $98.3{\pm}1.5%$ for single arc and dual arc, respectively. The confidence limit values were within 4%. The smaller the gantry spacing, the more accuracy results were shown. In this study, we performed the VMAT QA based on TG-119 procedure, and demonstrated that all structure sets were satisfied with acceptance criteria. And also, the results for the selective optimization variables informed the importance of selection for the suitable variables according to the clinical cases.

The Evaluation of Radiation Dose to Embryo/Fetus and the Design of Shielding in the Treatment of Brain Tumors (임산부의 전뇌 방사선 치료에 있어서의 태아의 방사선량 측정 및 차폐 구조의 설계)

  • Cho, Woong;Huh, Soon-Nyung;Chie, Eui-Kyu;Ha, Sung-Whan;Park, Yang-Gyun;Park, Jong-Min;Park, Suk-Won
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.4
    • /
    • pp.203-210
    • /
    • 2006
  • Purpose : To estimate the dose to the embryo/fetus of a pregnant patient with brain tumors, and to design an shielding device to keep the embryo/fetus dose under acceptable levels Materials and Methods : A shielding wall with the dimension of 1.55 m height, 0.9 m width, and 30 m thickness is fabricated with 4 trolleys under the wall. It is placed between a Patient and the treatment head of a linear accelerator to attenuate the leakage radiation effectively from the treatment head, and is placed 1 cm below the lower margin of the treatment field in order to minimize the dose to a patient from the treatment head. An anti-patient scattering neck supporters with 2 cm thick Cerrobend metal is designed to minimize the scattered radiation from the treatment fields, and it is divided into 2 section. They are installed around the patient neck by attach from right and left sides. A shielding bridge for anti-room scattered radiation is utilized to place 2 sheets of 3 mm lead plates above the abdomen to setup three detectors under the lead sheets. Humanoid phantom is irradiated with the same treatment parameters, and with and without shielding devices using TLD, and ionization chambers with and without a build-up cap. Results : The dose to the embryo/fetus without shielding was 3.20, 3.21, 1.44, 0.90 cGy at off-field distances of 30, 40, 50, and 60 cm. With shielding, the dose to embryo/fetus was reduced to 0.88, 0.60, 0.35, 0.25 cGy, and the ratio of the shielding effect varied from 70% to 80%. TLD results were 1.8, 1.2, 0.8, 1.2, and 0.8 cGy. The dose measured by the survey meter was 10.9 mR/h at the patient's surface of abdomen. The dose to the embryo/fetus was estimated to be about 1 cGy during the entire treatment. Conclusion : According to the AAPM Report No 50 regarding the dose limit of the embryo/fetus during the pregnancy, the dose to the embryo/fetus with little risk is less than 5 cGy. Our measurements satisfy the recommended values. Our shielding technique was proven to be acceptable.

Analysis of Respiratory Motional Effect on the Cone-beam CT Image (Cone-beam CT 영상 획득 시 호흡에 의한 영향 분석)

  • Song, Ju-Young;Nah, Byung-Sik;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Yoon, Mi-Sun
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.81-86
    • /
    • 2007
  • The cone-beam CT (CBCT) which is acquired using on-board imager (OBI) attached to a linear accelerator is widely used for the image guided radiation therapy. In this study, the effect of respiratory motion on the quality of CBCT image was evaluated. A phantom system was constructed in order to simulate respiratory motion. One part of the system is composed of a moving plate and a motor driving component which can control the motional cycle and motional range. The other part is solid water phantom containing a small cubic phantom ($2{\times}2{\times}2cm^3$) surrounded by air which simulate a small tumor volume in the lung air cavity CBCT images of the phantom were acquired in 20 different cases and compared with the image in the static status. The 20 different cases are constituted with 4 different motional ranges (0.7 cm, 1.6 cm, 2.4 cm, 3.1 cm) and 5 different motional cycles (2, 3, 4, 5, 6 sec). The difference of CT number in the coronal image was evaluated as a deformation degree of image quality. The relative average pixel intensity values as a compared CT number of static CBCT image were 71.07% at 0.7 cm motional range, 48.88% at 1.6 cm motional range, 30.60% at 2.4 cm motional range, 17.38% at 3.1 cm motional range The tumor phantom sizes which were defined as the length with different CT number compared with air were increased as the increase of motional range (2.1 cm: no motion, 2.66 cm: 0.7 cm motion, 3.06 cm: 1.6 cm motion, 3.62 cm: 2.4 cm motion, 4.04 cm: 3.1 cm motion). This study shows that respiratory motion in the region of inhomogeneous structures can degrade the image quality of CBCT and it must be considered in the process of setup error correction using CBCT images.

  • PDF

Radioprotective Effects of Granulocyte-Colony Stimulating Factor in the Jejunal Mucosa of Mouse (생쥐에서 과립구 집락형성인자(Granulocyte-Colony Stimulating Factor)의 공장점막에 대한 방사선 보호효과)

  • Ryu, Mi-Ryeong;Chung, Su-Mi;Kay, Chul-Seung;Kim, Yeon-Shil;Yoon, Sei-Chul
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • Purpose : Granulocyle-colony stimulating factor (G-CSF) has been widely used to treat neutropenia caused by chemotherapy or radiotherapy. The efficacy of recombinant human hematopoietic growth factors in improving oral mucositis after chemotherapy or radiotherapy has been recently demonstrated in some clinical studies. This study was designed to determine whether G-CSF can modify the radiation injury of the intestinal mucosa in mice. Materials and Methods : One hundred and five BALB/c mice weighing 20 grams were divided into nine subgroups including G-CSF alone group $(I:10\;{\mu}g/kg\;or\;II:100\;{\mu}g/kg)$, radiation alone group (7.5 or 12 Gy on the whole body), combination group with G-CSF and radiation (G-CSF I or II plus 7.5 Gy, G-CSF I or II plus 12 Gy), and control group. Radiation was administered with a 6 MV linear accelerator (Mevatron Siemens) with a dose rate of 3 Gy/min on day 0. G-CSF was injected subcutaneously for 3 days, once a day, from day -2 to day 0. Each group was sacrificed on the day 1, day 3, and day 7. The mucosal changes of jejunum were evaluated microscopically by crypt count per circumference, villi length, and histologic damage grading. Results : In both G-CSF I and II groups, crypt counts, villi length, and histologic damage scores were not significantly different from those of the control one (p>0.05). The 7.5 Gy and 12 Gy radiation alone groups showed significantly lower crypt counts and higher histologic damage scores compared with those of control one (p<0.05). The groups exposed to 7.5 Gy radiation plus G-CSF I or II showed significantly higher crypt counts and lower histologic damage scores on the day 3, and lower histologic damage scores on the day 7 compared with those of the 7.5 Gy radiation alone one (p<0.05). The 12 Gy radiation plus G-CSF I or II group did not show significant difference in crypt counts and histologic damage scores compared with those of the 12 Gy radiation alone one (p>0,05). Most of the mice in 12 Gy radiation with or without G-CSF group showed intestinal death within 5 days. Conclusion : These results suggest that G-CSF may protect the jejunal mucosa from the acute radiation damage following within the tolerable ranges of whole body irradiation in mice.

  • PDF

Effects of Adjuvant Radiation Therapy and Chemotherapy Following Curative Surgery in Locally Advanced Rectal Cancer (국소 진행된 직장암에서 근치적 절제술 후 방사선치료와 항암화학요법과의 병용치료에 대한 효과)

  • Kang, Ki-Mun;Choi, Ihl-Bohng;Kim, In-Ah;Jang, Jee-Young;Shin, Kyung-Sub;Jang, Suck-Kyun;Lee, Jae-Hak;Kim, Young-Ha;Won, Chong-Man;Choi, Dong-Hwan;Kim, Jin-Seung;Park, Shinn-Hee
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.121-128
    • /
    • 1997
  • Purpose : To evaluate the effect of postoperative adjuvant radiation therapy and chemotherapy on the survival, pattern of failure and complication for locally advanced rectal carcinoma Materials and Methods : From October 1992 to September 1995, twenty eight patients with rectal carcinoma were treated by postoperative adjuvant radiation therapy and chemotherapy Radiation therapy was delivered with 6MV and 15MV linear accelerator, 180c0y fractions 5 day per week. Total radiation doses were 5040cGy in $B_{2+3}$ and 5580cGy in $C_{2+3}$. Within 4 weeks after radical surgery. 5-FU$(400mg/m^2/day)\;and\;Leucovorin(20mg/m^2/day)$ were administered by intravenous injection for 4 days during the first and fifth week of radiation therapy. The median follow up was 19 months with a range 2 to 47 months. Results : The 2 year overall survival and disease free survival rates were $78.6\%\;and\;70.8\%$, respectively. The 2 year overall survival was $93.0\%\;in\;B_{2+3}$ and $76.2\%\;in\;C_{2+3}$(p=0.11) The 2 year disease free survival was $79.4\%\;in\;B_{2+3}\;and\;69.2\%\;in\;C_{2+3}(p=0.13)$. The overall failure rate was $21.42\%$(6/28) including $10.72\%$(3/28) locoregional recurrence, $3.62\%$(1/28) distant metastasis and $7.12\%$(2/28) locoregional recurrence with distant metastasis. The overall locoregional recurrence rate was $17.92\%$(5/28). The 2 year locoregional recurrence rates were $13.32\%(2/15)\;and\;23.12\%$(3/13) for respectively for $B_{2+3}\;and\;C_{2+3}$ The difference between the locoregional recurrence of $B_{2+3}\;and\;C_{2+3}$ patients was not significant(p=0.07). Complications developed in 13 patients$(46.42\%)$, including 8 dermatitis, 7 loose stool, 6 leukopenia, 4 tenesmus, 2 diarrhea. In Univariate analysis, there was no statistically significant factor except for tumor grade in locoregional recurrence, disease free survival and overall survival rate(p=0.04, 0.05, 0.04). Conclusion : This study sugges1s that postoperative adjuvant radiation therapy and chemotherapy is effective in patients with locally advanced rectal cancer. Therefore these results need to be confirmed with a long term follow-up and larger number of patients with the further clinical trials including prospective controlled studies.

  • PDF

Therapeutic Results of Radiotherapy in Rectal Carcinoma - Comparison of Sandwich Technique Radiotherapy with Postoperative Radiotherapy (직장암의 방사선 치료 결과 - Sandwich Technique 방사선 치료와 수술후 방사선 치료의 비교)

  • Huh Cil Cha;Suh Hyun Suk;Lee Hyuk Sang;Kim Re Hwe;Kim Chul Soo;Kim Hong Yong;Kim Sung Rok
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.25-31
    • /
    • 1996
  • Purpose : To evaluate the potential advantage for 'sandwich' technique radiotherapy compared to Postoperative radiotherapy in resectable rectal cancer. Materials and Methods : Between January 1989 and Mar 1994, 60 patients with resectable rectal cancer were treated at Inje University Seoul and Sanggye Paik Hospital. Fifty one patients were available for analysis: 20 patients were treated with sandwich technique radiotherapy and 31 patients were treated with Postoperative radiotherapy. In sandwich technique radiotherapy(RT), Patients were treated with preoperative RT 1500 cGy/5fx, followed by immediate curative resection. Patients staged as Astler-Coiler B2, C were considered for postoperative RT with 2500-4500 cGy. in postoperative RT total radiation dose of 4500-6120 cGy, 180 cGy daily at 4-Sweets was delivered. Patients were followed for median period of 25 months. Results : The overall 5-year survival rates for sandwich RT group and postoperative RT group were $60\%$ and $71\%$, respectively(p>0.05). The 5-rear disease free survival rates for each group were $63\%$. There was no difference in local failure rate between two groups($11\%$ versus $7\%$) Incidence of distant metastasis was $11\%$(2/20) in the sandwich technique RT group and $20\%$(6/31) in the postoperative RT group(p>0.05). The frequencies of acute and chronic complications were comparable in both groups. Conclusion : The sandwich technique radiotherapy group shows local recurrence and survival similar to those of Postoperative RT alone group but reduced distant metastasis compared to Postoperative RT group. But long term follow-up and large number of patients is needed to make an any firm conclusion regarding the value of this sandwich technique RT.

  • PDF