An Economic Design of Constant Stress Accelerated Life Tests (일정스트레스 가속수명시험의 경제적 설계)

  • 윤원영;반한석
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.19 no.1
    • /
    • pp.145-152
    • /
    • 1994
  • This paper deals with an economic design of acelerated life test under constant stresses where failure times are exponentially distributed. In this case the optimization criterion is the information amount per unit cost. Fisher's information matrix of exponential distribution's parameters and expected cost considering fixed and variable costs are obtained. The decision variable is the censoring time in the model. In the 2-level constant stress case, it is proved that the optimal solution exists and is unique under some condition. Numerical examples are also included.

  • PDF

Characteristics of Accelerated Aging in Generator Stator Windings (발전기 고정자 권선의 가속열화 특성)

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.279-280
    • /
    • 2008
  • Accelerated aging tests were conducted under laboratory conditions on two generator stator bars. Electrical stress is applied in No. 1 model stator bar. Electrical and thermal stresses are applied in No. 2 model stator bar. As aging times increased from 0 to 4780h, diagnostic tests were performed on No. 1 and No. 2 model stator bars. Diagnostic tests included AC current, dissipation factor(tan$\delta$) and partial discharge magnitude. The ${\Delta}tan{\delta}$ and $\Deta$I of No. 1 and No. 2 model stator bars increased with increased in aging time.

  • PDF

A Study on Selection of Distribution Function for Reliability Prediction Using Accelerated Life Test Data (가속 수명시험 데이터를 기반으로 하는 신뢰성 예측에 적합한 분포 함수 선택에 관한 연구)

  • Kim Ji-Hun;Park Dong-Gue;Han Hyun-Kak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.3
    • /
    • pp.393-397
    • /
    • 2006
  • The study about Accelerated Life Test and analysis of failed data is increased in order to predict and evaluate reliability of products, according as the development cycle of products is reduced. Therefore, the decision of optimal distribution function about failed data for accurate analysis of failed data and test condition for Accelerated Life Test is very important. This paper compares Anderson-Darling method with Likelihood Function method for the decision of optimal distribution function about failed data. Anderson-Darling considers only failed data and Likelihood Function considers both failed data and life-stress relationship in decision of distribution function. In the results of comparison about two methods, we found that the distribution function chosen by each method is different and the life time predicted by each decided distribution function is different.

  • PDF

Study on Corrosion of Automotive Coil Spring Steel by Electrochemical Impedance Spectroscopy (전기화학 임피던스 분석을 통한 자동차용 코일스프링 강의 부식 평가)

  • Lee, Kyu Hyuk;Park, Jung-Hyun;Ahn, Seung Ho;Seo, Ji Won;Jang, HeeJin
    • Corrosion Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.298-304
    • /
    • 2017
  • Coil spring steels from the automobile suspension part after field exposure for 10 years and those after anti-corrosion validation test in proving ground of 5,000 ~ 10,000 km were examined for corrosion damages. Partial loss of paint, accumulation of corrosion product, and cracking of paint and superficial material were observed. The surface and subsurface region of spring steels had compressive residual stress and high hardness by shot peening. The surface hardness values of the specimens were 620 ~ 670 Hv. They were 60 ~ 80 Hv higher than those of the samples taken from the middle part of the spring. The maximum compressive stress was -916 ~ -1208 MPa measured at depth of about $100{\mu}m$. Electrochemical impedance spectroscopy showed that the resistances of charge transfer and the paint layer of the spring steels ranged from several tens to millions ${\Omega}{\cdot}cm^2$. The resistance of the field samples was much higher than that of the proving ground samples used in this study, implying that the proving ground test condition would be more corrosive than the field environment.

A Study on Procedures of the Accelerated Life Testing for Hose Assemblies (플라스틱 호스 조립체의 가속수명시험 방법에 대한 연구)

  • Lee, Yong-Beom;Kim, Hyeong-Ui;Kim, Jong-Gi;Park, Jong-Ho
    • 연구논문집
    • /
    • s.34
    • /
    • pp.79-85
    • /
    • 2004
  • There are several types of life test method for hose assemblies. The two major tests used for hose assemblies are impulse test and burst test. And magnification adjustment of impulse pressure, heating of testing oil and repetitive motions of bending and straightening of testing hose are also performed for accelerating the life. According to the manufacture process of hose and swaging process of fitting, there is a difference in the life of hose assemblies from minimum 7 times to maximum 40 times during the life test in the same functioning condition. Like this, the life test of hose which has a wide scope of life distribution gives a problem that observation should take a long time to find out the existence of the bursting from the beginning of the test to the completion of bursting of hose assemblies. Therefore, this research proposes a process of concentrating on the defective section of hose assemblies and maximizing the life acceleration by giving 'Knockdown stress' to hose assemblies just until before the hose assemblies get out of order.

  • PDF

The analysis of electrical characteristics with Micro-crack in PV module (Micro-cracks에 의한 PV 모듈의 전기적 특성 분석)

  • Song, Young-Hun;Ji, Yand-Geun;Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Gun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.25-30
    • /
    • 2011
  • In this paper, we analyzed the electrical characteristics with Micro-cracks in Photovoltaic module. Micro cracks are increasing the breakage risk over the whole value chine from the wafer to the finished module, because the wafer or cell is exposed to mechanical stress. And The solar cells have to with stand the stress under out door operation in the finished module. Here the mechanical stress is induced by temperature changes and mechanical loads from wind and snow. So, we experimentally analyze the direct impact of micro-cracks on the module power and the consequences after artificial aging. The first step, we made micro-cracks in PV module by mechanical load test according to IEC 61215. Next, PV modules applied the thermal cycling test, because micro-cracks accelerated aging by thermal cycling test, according to IEC61215. Before every test, we checked output and EL image of PV module. As the result of first step, we detected little power loss(0.9%). But after thermal cycling test increased power loss about 3.2%.

  • PDF

Accelerated Life Test Design of Bladder Type Accumulator Assembly for Helicopter (헬기용 블래더형 축압기 조립체의 가속수명시험 설계)

  • Kim, Dae-Yu;Hur, Jang-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.239-245
    • /
    • 2018
  • The importance of reliability in the development of weapons systems and reliability tests has been emphasized recently. Therefore, this study evaluated a reliability test design method of a bladder type accumulator and proposed a process for reliability test design. To design the reliability test of the accumulator, the main failure modes and failure mechanisms were investigated, and the main stress factors were analyzed to select the appropriate acceleration model. A steady - state reliability test was designed according to the number of samples, and the reliability level and accelerated life test time were calculated according to the acceleration factor computed using the selected acceleration model.

Characteristics of Insulation Aging in Large Generator Stator Windings (대용량 발전기 고정자 권선의 절연열화 특성)

  • Kim, Hee-Dong;Lee, Young-Jun;Ju, Young-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1375-1379
    • /
    • 2009
  • Insulation tests have been performed on two generator stator bars under accelerated aging under a laboratory environment. Electrical stress was applied to stator bar No.1, and electrical and thermal stresses were applied to stator bar No.2. Nondestructive stator insulation tests including the ac current, dissipation factor($tan{\delta}$), and partial discharge tests have been performed on both bars as the bars were aged for 11460 hours. Experimental test results show that ${\Delta}I$, ${\Delta}tan{\delta}$, and partial discharge of No. 1 and No.2 stator bars increased with increased in aging time. It has been concluded from the test that the stator insulation of the two generators are in good condition.

Lifetime Estimation of High Power White LED for Lighting Use (고출력 조명용 White LED의 수명예측)

  • Lee, Myeong-Hoon;Shin, Seung-Jung;Kwack, Kae-Dal
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1343-1348
    • /
    • 2008
  • LEDs which have many merits are widely used in the field of light devices, and have rapidly replaced old light devices such as incandescent or fluorescent lamps. Long life, on the order of 50,000 to 100,000 hours, is one of the key features of light emitting diodes(LEDs) that has attracted the lighting community to this technology. High Power white LEDs have yet to demonstrate this capability. This paper planed accelerated life test that has two factor(temperature, current) and two levels. Finally, using ALTA programs, we estimated the common shape parameter of Weibull distribution, life-stress relationship, B10 life and accelerating factors.

  • PDF

Mechanical Reliability(Life-Time) Estimation for 25.8kV Eco Solid Insulated Switchgear (25.8kV급 친환경 고체절연차단기(Solid Insulated Switchgear)에 대한 기계적 신뢰성(수명) 평가)

  • Lee, Do-Hoon;Lee, Seog-Won;Park, Seok-Weon;Kim, Young-Geun;Lee, Jhong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.202-205
    • /
    • 2010
  • In this paper, mechanical reliability(Life-time) estimation method for 25.8kV SIS(Solid Insulated Switchgear) has been studied. Recently enacted KEPCO's standard includes clause that have to submit a warrantable reliability data for life-time(over B10 25 years) of an epoxy-solid insulating material. Accordingly, this research was carried out on the ALT(Accelerated Life Test) and Life-Estimation method for SIS's insulating material. Mechanical life-time estimation for SIS's insulating material is to verify reliability for tensile creep & fatigue stress, which is the major mechanical stress of SIS. This study proved that SIS's reliability for mechanical stress and established that confidence for estimation results in further verification test.