• 제목/요약/키워드: Accelerated aging condition

검색결과 79건 처리시간 0.025초

가속열화 된 CSPE 상태감시법의 유효성 연구 (A Study on Validation of Condition Monitering Method of Accelerated Thermal Aging CSPE)

  • 신용덕;구철수;김인용;이정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1447-1448
    • /
    • 2011
  • The CSPE cables are used for three years in nuclear power plant. The accelerated thermal aging of chloro sulfonate polyethylene(CSPE) jacket of test cables were carried out for the period equal to 10, 20 and 30 years in air at 90 and $100^{\circ}C$, respectively. The electrical volume resistivity, density, XPS, FE-SEM, EDS and XRF of the accelerated thermal aging of CSPE were measured. The validation of condition monitering method of accelerated thermal aging CSPE was estimated by them. The best validation of condition monitoring method of accelerated aging CSPE is electrical volume resistivity because change thermal of the specimen showed distinction.

  • PDF

가속열화 된 CSPE 상태감시법 유효성 평가 (A Study on Practicality of Condition Monitoring Method of Accelerated Thermal Aging CSPE)

  • 이정훈;구철수;김인용;신용덕
    • 전기학회논문지
    • /
    • 제60권11호
    • /
    • pp.2088-2092
    • /
    • 2011
  • The accelerated thermal aging of CSPE(chloro sulfonate polyethylene) of test cables were carried out for the period equal to 10, 20 and 30 years in air at $100^{\circ}C$, respectively. The CSPE cables(TAIHAN electric wire Co. Ltd) which installed in nuclear power plant for three years were used as starting materials. Condition monitering methods of the accelerated thermal aging of CSPE cables were estimated through indenter modulus and OIT(oxidation induction time) of IEC 62582, and those were newly estimated through volume electrical resistivity, ultrasound reflection time, density, FE-SEM(field emission scanning electron microscopy), XPS(x-ray photoelectron spectroscopy), EDS(energy dispersive spectroscopy), and WD-XRF(wavelength dispersive x-ray fluorescence). A new condition monitoring methods of the accelerated thermal aging of CSPE cables were generally coincident with trend of indenter modulus expect EDS, XPS and XRF. A volume electrical resistivity among new condition monitoring methods of the accelerated thermal aging of CSPE cables is excellent. It is considered that life-time of CSPE cable can be predicted through volume electrical resistivity, if CSPE jacket was aged for period such as more than 20 years.

복합 가속열화를 통한 배전용 고분자 피뢰기의 장기 열화특성 예측 (Longterm Aging Characteristics of Distribution Polymer Housed Surge Arresters by Multistress Accelerated Aging)

  • 김주용;권태호;박철배;김준일
    • 한국전기전자재료학회논문지
    • /
    • 제20권8호
    • /
    • pp.691-696
    • /
    • 2007
  • In this study accelerated aging test equipment was developed to simulate domestic weather condition for accelerated aging test of polymer housed distribution surge arresters. Polymer arresters were aged for 3,000 hours by this test equipment and chemical and electrical characteristics analysis of surge arresters were conducted after aging test. In addition, performance assessment of outdoor installed arresters for 3 years was conducted to compare aging effect between accelerated aging test and natural aging. Through this experiment it is verified that the capability of the proposed aging test for simulating natural aging and the housing material and disconnector of domestic polymer arresters can be deteriorated by the long time field operation.

Evaluation of Nuclear Plant Cable Aging Through Condition Monitoring

  • Kim, Jong-Seog;Lee, Dong-Ju
    • Nuclear Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.475-484
    • /
    • 2004
  • Extending the lifetime of a nuclear power plant [(hereafter referred to simply as NPP)] is one of the most important concerns in the global nuclear industry. Cables are one of the long-life items that have not been considered for replacement during the design life of a NPP. To extend the cable life beyond the design life, it is first necessary to prove that the design life is too conservative compared with actual aging. Condition monitoring is useful means of evaluating the aging condition of cable. In order to simulate natural aging in a nuclear power plant. a study on accelerated aging must first be conducted. In this paper, evaluations of mechanical aging degradation for a neoprene cable jacket were performed after accelerated aging under tcontinuous and intermittent heating conditions. Contrary to general expectations, intermittent heating to the neoprene cable jacket showed low aging degradation, 50% break-elongation, and 60% indenter modulus, compared with continuous heating. With a plant maintenance period of 1 month after every 12 or 18 months operation, we can easily deduce that the life time of the cable jacket of neoprene can be extended much longer than extimated through the general EQ test. which adopts continuous accelerated aging for determining cable life. Therefore, a systematic approach that considers the actual environment conditions of the nuclear power plant is required for determining cable life.

BD-R 장기보존 특성 평가를 위한 가속 열화 실험 조건과 안정성 평가 기준에 관한 연구 (A Study on Suitable Condition of Accelerated Aging Test and Evaluation Criteria of Data Stability for Archival Performance Analysis of BD-R media)

  • 이관용;박선주;김도현;조이형;김영주
    • 정보저장시스템학회논문집
    • /
    • 제10권1호
    • /
    • pp.7-13
    • /
    • 2014
  • The Blu-ray Disc Recordable(BD-R) is one of strong candidates for archival application among optical media formats, because of its large capability. However, the well-defined accelerated aging test conditions and evaluation criteria have not yet been fully confirmed for BD-R. In this study, the data stability and degradation aspect of BD-R were analyzed by the random-symbol error rate(R-SER) measurement after the accelerated aging test. And a reasonable test condition of accelerated aging for BD-R and the appropriate evaluation criterion using R-SER measurement were discussed.

CSPE 케이블의 상태감시를 위한 가속열화 측정 분석 (Accelerated Thermal Aging Measurement and Analysis of CSPE Cable for Condition Monitoring)

  • 박정호;차왕철;이정훈;조욱래;김재철
    • 조명전기설비학회논문지
    • /
    • 제29권3호
    • /
    • pp.88-95
    • /
    • 2015
  • The accelerated thermal aging of CSPE(Chloro Sulfonate Polyethylene) was carried out for 40.41, 121.22, 202.04 days, 16.82, 50.45, 84.09 days and 7.32, 21.96, 36.59 days at 100, 110, and $120^{\circ}C$, respectively, which are equivalent to 20, 60, 100 years of aging at $50^{\circ}C$. The permittivities and the apparent densities of the accelerated thermally aged CSPE samples are increased with accelerated thermal aging year but EAB(Elongation at Break) is decreased with that. The dielectric strength and the electric breakdown of the non-accelerated and accelerated thermally aged CSPE samples do not depend on accelerated thermal aging year and applied voltage rising time. density and EAB measures.

폴리머 피뢰기 가속열화 방법과 열화특성 분석 (Accelerated aging test method and characteristics analysis of polymer housed surge arresters)

  • 김주용;박철배;권태호;정연하
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.210-213
    • /
    • 2007
  • In this study accelerated aging test cycle and equipment was developed for aging test of polymer housed surge arresters under domestic weather condition In order to investigate aging characteristics of polymer surge arresters electrical and chemical analysis of the arresters which are used for accelerated aging test and outdoor exposure test were conducted. Through the analysis the capability of the proposed method was verified and characteristics data were presented for maintenance of domestic arresters. Based on these results long term reliability assessment method was proposed for polymer housed distribution surge arresters.

  • PDF

과도서지를 이용한 가속열화 시험법에 따른 견인전동기 고정자 코일의 전기적 특성 변화 (Properties of Electrical Performance on Stator Coil of Traction Motor by Accelerated lest using Transient Surge)

  • 박현준;장동욱;이길헌;최종선;김저우
    • 한국전기전자재료학회논문지
    • /
    • 제16권9호
    • /
    • pp.783-789
    • /
    • 2003
  • The winding problems of traction motor are the major determinant of motor's life. The root cause of winding failure is gradual deterioration of the insulation due to thermal, electrical, mechanical and environmental stresses. The aging of the insulation reduces the electrical and mechanical strength of the insulation. At same point, a voltage surge or mechanical shock from a traction motor start will fracture or break down the insulation. To achieve the expected life usually requires extensive laboratory evaluation of the insulation systems and the use of accelerated aging tests. There are several nondestructive test available for checking, the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of dielectric loss(tan$\sigma$), capacitance and partial discharge. The method of diagnosis is able to analyze the insulation condition and evaluate the life of the traction motor.

Salt Water Boiling에 의한 Silicone Rubber의 표면열화특성 (A Surface Aging Characteristics of Silicone Rubber by Boiling in Salt Water)

  • 한상일;유승덕;이병성;윤진열;박강식;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 C
    • /
    • pp.1497-1499
    • /
    • 1997
  • This paper dealt with the surface aging characteristics of silicone rubber used as the surface material of outdoor polymer insulators under accelerated aging condition. There are many aging factors in natural environment. In this paper, the silicone rubber were accelerated to evaluate their performance against salt fog, that is, they were dipped in pure water and salt water under boiling condition. Then, contact angle and SEM(Scanning Electron Microscope) were used to estimate surface hydrophobicity, and dielectric loss($tan{\delta}$) and surface leakage current were measured to observe the electrical characteristics.

  • PDF

가속노화에 따른 BKNO3의 아레니우스 동역학 상수 분석 (Arrhenius Kinetic Constants Analysis of BKNO3 under Accelerated Aging)

  • 장승교;김준형;류병태;황정민
    • 한국추진공학회지
    • /
    • 제20권4호
    • /
    • pp.34-39
    • /
    • 2016
  • 열분석기인 시차 주사 열량계를 이용하여 $BKNO_3$ 화약의 아레니우스(Arrhenius) 동역학 상수인 활성화 에너지와 Pre-Exponential Factor를 구하였다. 기존의 방법과 달리 고온 가속 노화와 DSC를 병행하여 보다 정밀한 활성화 에너지를 구하였고 열 유속의 적분값을 비교하여 저장 온도에 따른 분율을 구하였다. 이를 통하여 수명 예측을 위한 $BKNO_3$ 화약의 가속노화 시험 조건을 제시하고 열 가속노화에 관한 의미를 재고하였다.