• Title/Summary/Keyword: Accelerated aging

Search Result 498, Processing Time 0.028 seconds

Electrical and Dielectric Properties, and Accelerated Aging Characteristics of Lanthania Doped Zinc Oxide Varistors

  • Nahm, Choon-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.4
    • /
    • pp.189-195
    • /
    • 2006
  • The microstructure, electrical and dielectric properties, and stability against DC accelerated aging stress of the varistors, which are composed of quaternary system $ZnO-Pr_6O_{11}CoO-Cr_2O_3-based$ ceramics, were investigated for different $La_2O_3$ contents. The increase of $La_2O_3$ content led to more densified ceramics, whereas abruptly decreased the nonlinear properties by incorporating beyond 1.0mol%. The highest nonlinearity was obtained from 0.5mol% $La_2O_3$, with the nonlinear coefficient of 81.6 and the leakage current of $0.1{\mu}A$. The varistors doped with 0.5mol% $La_2O_3$ exhibited high stability, in which the variation rates of breakdown voltage, nonlinear coefficient, leakage current, dielectric constant, and dissipation factor were -1.1%, -3.7%, +100%, +1.4%, and +8.2%, respectively, for stressing state of $0.95V_{1mA}/150^{\circ}C/24h$.

Effects of Freshwater Flooding on the Properties of the Accelerated Thermally Aged CSPE (가속열화 된 CSPE의 특성에 미치는 담수침지의 영향)

  • Kang, Myeong-Gyun;Lee, Jung-Hoon;Lee, Seung-Hoon;Jeon, Jun-Soo;Kim, In-Yong;Shin, Yong-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.367-370
    • /
    • 2014
  • The accelerated thermal aging of a CSPE were carried out for 0, 80.82, 161.63 days at $100^{\circ}C$, which are equal to 0, 40 and 80 years, respectively. The volume electrical resistivities of the non-accelerated thermally aged CSPE and the accelerated thermally aged CSPE for 40y and 80y were $9.620{\times}10^{12}{\sim}1.246{\times}10^{13}{\Omega}{\cdot}cm$, $5.066{\times}10^{12}{\sim}7.576{\times}10^{12}{\Omega}{\cdot}cm$ and $7.195{\times}10^{12}{\sim}9.208{\times}10^{12}{\Omega}{\cdot}cm$ at room temperature, respectively. The dielectric constant of the non-accelerated thermally aged CSPE and the accelerated thermally aged CSPE for 40y and 80y were 3.355~4.030, 2.996~3.963 and 3.020~4.776 at room temperature, respectively. After seawater and freshwater flooding, the volume electrical resistivity of the CSPE trend slightly upward according to drying day at room temperature. After seawater flooding, the dielectric constant of the accelerated thermally aged CSPE were not measured. After seawater flooding, bright open pores of the accelerated thermally aged CSPE were partly transferred to dark close pores due to salinity. After freshwater flooding, dark close pores of the accelerated thermally aged CSPE were partly transferred to bright open pores because salinity of them is decreased. An insulation property of a cable in NPPs was decreased because of the seawater flooding, and an insulation property of them was recovered through the freshwater flooding. As a result, it is considered that an insulation property of a contaminated cable through Tsunami can be recovered if it is cleaned quickly.

Influence of the Cure Systems on Long Time Thermal Aging Behaviors of NR Composites

  • Choi, Sung-Seen;Kim, Jong-Chul;Lee, Seung-Goo;Joo, Yong-L.
    • Macromolecular Research
    • /
    • v.16 no.6
    • /
    • pp.561-566
    • /
    • 2008
  • NR composites with different curing systems were aged thermally at 60, 70, 80, and $90^{\circ}C$ for 2-185 days in a convection oven, and the changes in the crosslink density were investigated as a function of the accelerated thermal aging. The overall crosslink densities increased with increasing aging time irrespective of the aging temperatures and curing systems. The changes in crosslink density were enhanced by increasing the aging temperature. The degree of the increased crosslink density was in the following order: "the conventional cure system > the semi-EV system > the EV system". For short term thermal aging, the change in crosslink density with the aging time was complicated, particularly for low temperature aging. The activation energies of the change in crosslink density with thermal aging using the conventional and semi-EV cure systems increased and then remained relatively constant with increasing aging time, whereas that of the specimen with an EV cure system tended to increase linearly. The experimental results were explained by the dissociation of the existing polysulfidic linkages and the formation of new cross links through the crosslinking-related chemicals remaining in the sample.

Storage Reliability Evaluation of Engine Assembly (엔진 조립체의 저장 신뢰도 평가)

  • Park, Jong-Won;Chang, Mu-Seong;Park, Tae-Kook;Kim, You-Il;Kim, Sun Je
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.157-159
    • /
    • 2017
  • This paper presents a storage reliability evaluation method based on the accelerated degradation test for the engine assembly and parts of the guided missile. The test of the engine assembly is performed at accelerated conditions equivalent to the real storage period, and then the aging condition of parts is checked. For engine parts, performance degradation characteristics are measured periodically at the accelerated conditions and failure times are predicted at each condition. Storage lifetime at normal use conditions is predicted using an accelerated model and failure times at all accelerated conditions.

  • PDF

DC Accelerated Aging Characteristics of Praseodymium-Based ZnO Varistors Doped with $Dy_2O_3$ ($Dy_2O_3$가 첨가된 프라세오디뮴계 ZnO 바리스터의 DC 가속열화특성)

  • Ryu, Jung-Sun;Jung, Young-Chul;Kim, Hyang-Suk;Nahm, Choon-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.78-80
    • /
    • 2001
  • DC accelerating aging characteristics of praseodymium-based ZnO varistors doped with $Dy_2O_3$ were investigated with sintering time. The varistor sintered for 1h exhibited the highest nonlinearity, with a nonlinear exponent of 66.61 and a leakage current of $1.16{\mu}A$, whereas they did not exhibit relatively high stability. The varistor sintered for 2h having nonlinear exponent of 54.81 and leakage current of $2.52{\mu}A$ showed very excellent stability, which the variation rates of varistor voltage, nonlinear exponent, and leakage current are -1.19%, -4.00%, and +75.79% for 2h, under DC accelerated aging stress, such as ($0.85\;V_{1mA}/115^{\circ}C$/24h)+($0.90\;V_{1mA}/120^{\circ}C$/24h)+($0.95\;V_{1mA}/125^{\circ}C$/24h)+($0.95\;V_{1mA}/150^{\circ}C$/24h).

  • PDF

A Durability Study on the Acoustic Baffle for Underwater Environment (수중 환경용 음향 배플의 내구성 연구)

  • Seo, Young Soo;Kim, Dong Hyun;Kim, Jin Tae;Kang, Myeng Hwan;Jung, Woo Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.449-457
    • /
    • 2016
  • Cylindrical array sensor of a surface ship to detect an enemy is normally installed in the sonar dome. Reflected signals by some structures inside the sonar dome make unwanted signals. To minimize unwanted signals, acoustic baffles are used. Acoustic baffles are hard to install and replace, so the durability of acoustic baffles is an important design parameter. To verify the durability of acoustic baffle, accelerated aging tests according to temperature and pressure were performed. Acoustic baffle specimens were made and they are tested the visual and the performance (echo reduction and transmission loss) inspection before and after aging. After the inspection, the effect of accelerated aging of the acoustic baffles were discussed.

Age-associated Alteration in the Hapatic Superoxide Generation and Antioxidant Activities in the Senescence-accelerated Mice (노화촉진 생쥐에서 노화에 따른 활성산소 생성 및 항산화능의 변화)

  • Chung, Hae-Young;Kim, Yun-Kyung
    • YAKHAK HOEJI
    • /
    • v.36 no.5
    • /
    • pp.460-468
    • /
    • 1992
  • Several bichemical parameters related to free radicals were estimated in senile-prone (P) and resistant(R) strains of male senescence-accelerated mice(SAM) at 2, 5 and 11 months of age. The superoxide generation was increased with age in SAM-R/1 and SAM-P/2. Compared to SAM-R/1, more generation of superoxide was significantly noted in the SAM-P/2 liver. The activities of Cu/Zn-superoxide dismutase and catalase were decreased during aging and these activities in SAM-P/2 were significantly lower than in SAM-R/l liver. The activities of glutathione S-transferase were varied with aging, whereas SAM-P/2 showed lower levels compared to SAM-R/l. The gradual decreases of glutathione, protein bound-SH and nonprotein bound-SH contents were noted with increasing age. SAM-P/2 liver contained lesser amounts of glutathione and nonprotein bound-SH compared to SAM-R. In conclusion, superoxide generation was increased whereas the antioxidant enzyme activities were decreased during aging in SAM-R/1. In addition, SAM-P/2 strain showed more superoxide generation and less antioxidant enzyme activities than SAM-R/1 in the liver, thus we assume that these factors might accelerate the senescence of SAM-P/2 strain.

  • PDF

A Study of Aging Effect for Train Carbody Using Accelerated Aging Tester

  • Nam, Jeong-Pyo;LI, Qingfen;LI, Hong
    • International Journal of Railway
    • /
    • v.1 no.3
    • /
    • pp.113-116
    • /
    • 2008
  • The long-tenn exposure of polymeric composite materials to extreme-use environments, such as pressure, temperature, moisture, and load cycles, results in changes in the original properties of the material. In this study, the effect of combined environmental factors such as ultraviolet ray, high temperature and high moisture on mechanical and thermal analysis properties of glass fabric and phenolic composites are evaluated through a 2.5 KW accelerated environmental aging tester. The environmental factors such as temperature, moisture and ultraviolet ray applied of specimens. A xenon-arc lamp is utilized for ultraviolet light and exposure time of up to 3000 hours are applied. Several types of specimens - tensile, bending, and shear specimens that are warp direction and fill direction are used to investigate the effects of environmental factors on mechanical properties of the composites. Mechanical degradations for tensile, bending and shear properties are evaluated through a Universal Testing Machine (UTM). Also, storage shear modulus, loss shear modulus and tan a are measured as a function of exposure time through a Dynamic Mechanical Analyzer (DMA). From the experimental results, changes in material properties of glass fabric and phenolic composites are shown to be slightly degraded due to combined environmental effects.

  • PDF

Evaluation of the Aging Life of the Rubber Pad in Power Window Switch

  • Kang, Yong Kyu;Choi, Byung Ik;Woo, Chang Su;Kim, Wan Doo
    • Elastomers and Composites
    • /
    • v.54 no.4
    • /
    • pp.351-358
    • /
    • 2019
  • To evaluate the aging of a rubber pad in power window switch which is the part of a vehicle, the accelerated thermal aging test of rubber pad material is performed. Finite element analysis was performed using the nonlinear material constants of the rubber pad to calculate the operating force, and the Arrhenius relationship was derived from the aging temperature and time. The aging test was performed at 150, 180, 210, or 240 ℃ for 1 to 60 days. When the operating force of the rubber pad is changed by 10% from the initial value, the service life is expected to be 113 years, which is much longer than the life of the vehicle. This indicates that the aging life of the rubber pad is sufficiently safe and the operating force of the rubber pad during the life of the vehicle (20 years) was decreased by approximately 8.4%. By examining the correlation between the shear elastic modulus and operating force calculated from finite element analysis under each aging test condition, the changes in the operating force of the rubber pad and the shear elastic modulus showed good linear relationship. The aging life could be predicted by the change in shear elastic modulus and a process for predicting the aging life of automotive power window switch rubber pad parts is described herein.

Performance Evaluation of Polymer Insulator using Tracking Wheel and Multi-Aging Test (트래킹 휠과 복합열화시험에 의한 폴리머 애자의 성능 평가)

  • 조한구;안명상;한세원;허종철;이운용
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.119-122
    • /
    • 2000
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. Polymer insulators are a relatively new technology, but their expected life is still unknown. Therefore these estimating technique are very important. Their life time is related to weathering and operating condition. Multi-aging test is requested because aging factor is occurred by multi-aging than unique aging. The aging test about polymer insulators have mainly carried out by IEC 61109. This paper presents multi-stress chamber experiments and tracking wheel test to examine the tracking and erosion performance of polymer insulator for transmission. Multi-stress testing is able to demonstrate deficiencies of polymer insulator materials and designs, including the nature of interfaces in insulation design. We have investigated IEC 61109 Annex C (5000h aging test) and CEA tracking wheel test as test methods of artificial accelerated aging. The aging degree of polymer insulator is estimated by leakage current, measurement of hydrophobicity degree, damage conditions of insulator surface, withstand voltage test etc.

  • PDF