• 제목/요약/키워드: Ac/ac conversion

검색결과 359건 처리시간 0.029초

Comparative Study on 220V AC Feed System and 300V DC Feed System for Internet Data Centers

  • Kim, Hyo-Sung
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.157-163
    • /
    • 2012
  • Internet Data Centers (IDCs), which are essential facilities in the modern IT industry, typically have scores of MW of concentrated electric loads. The provision of an Uninterruptible Power Supply (UPS) is necessary for the power feed system of IDCs owing to the need for stable power. Thus, conventional IDC AC power feed systems have three cascaded power conversion stages, (AC-DC), (DC-AC), and (AC-DC), resulting in a very low conversion efficiency. In comparison, DC power feed systems require only a single power conversion stage (AC-DC) to supply AC main power to DC server loads, resulting in comparatively high conversion efficiency and reliability [4-11]. This paper compares the efficiencies of a 220V AC power feed system with those of a 300V DC power feed system under equal load conditions, as established by the Mok-Dong IDC of Korea Telecom Co. Ltd. (KT). Experimental results show that the total operation efficiency of the 300V DC power feed system is approximately 15% higher than that of the 220V AC power feed system.

Utility AC Frequency to High Frequency ACPower Conversion Circuit with Soft Switching PWM Strategy

  • Sugimura Hisayuki;Ahmed Nabil A.;Ahmed Tarek;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권2호
    • /
    • pp.181-188
    • /
    • 2005
  • In this paper, a DC smoothing filterless soft switching pulse modulated high frequency AC power conversion circuit connected to utility. frequency AC power source is proposed for consumer induction heating hot water producer, steamer and super heated steamer. The operating principle of DC link filterless utility frequency AC-high frequency AC (HF AC) power conversion circuit defined as high frequency cycloinverter is described, which can operate under a principle of ZVS/AVT and power regulation based on alternate asymmetrical PWM in synchronization with the utility frequency single phase AC positive or negative half wave voltage. The dual mode modulation control scheme based on high frequency PWM and commercial frequency AC voltage PDM for the proposed high frequency cycloinverter are discussed to enlarge its soft switching commutation operating range for wide HF AC power regulation. This high frequency cycloinverter is developed for high frequency IH Dual Packs Heater (DPH) type boiler used in consumer and industrial fluid pipeline systems. Based on the experiment and simulation results, this high frequency cycloinverter is proved to be suitable for the consumer use IH-DPH boiler and hot water producers. The cycloinverter power regulation and power conversion efficiency characteristics are evaluated and discussed.

인터넷데이터센터의 교류, 직류급전시스템 비교 분석 (Comparative Study on AC and DC Feed System for Internet Data Center)

  • 김두환;김효성
    • 전력전자학회논문지
    • /
    • 제17권1호
    • /
    • pp.27-33
    • /
    • 2012
  • Internet Data Centers (IDC), as essential facilities for modern IT industry, typically have scores of MW of concentrated electric loads. Uninterruptible Power Supplies (UPS) are necessary for the power feed system of IDCs because of stable power requirement. Thus, conventional AC power feed systems of IDCs have three cascaded power conversion stages such as (AC-DC), (DC-AC), and (AC-DC), which results in very low conversion efficiency. On the contrary, DC power feed systems need just a single power conversion stage (AC-DC) supplying AC mains power to DC server loads, which gives comparatively high conversion efficiency and reliability. This paper compares the efficiencies between 220V AC power feed system and 300V DC power feed system on equal load conditions which were established in Mok-Dong IDC of Korea Telecom company (KT). Experimental results show that the total operation efficiency of the 300V DC power feed system is around 15% higher than that of the 220V AC power feed system.

Three-Phase PWM Inverter and Rectifier with Two-Switch Auxiliary Resonant DC Link Snubber-Assisted

  • Nagai Shinichiro;Sato Shinji;Matsumoto Takayuki
    • Journal of Power Electronics
    • /
    • 제5권3호
    • /
    • pp.233-239
    • /
    • 2005
  • In this paper, a new conceptual circuit configuration of a 3-phase voltage source, soft switching AC-DC-AC converter using an IGBT module, which has one ARCPL circuit and one ARDCL circuit, is presented. In actuality, the ARCPL circuit is applied in the 3-phase voltage source rectifier side, and the ARDCL circuit is in the inverter side. And more, each power semiconductor device has a novel clamp snubber circuit, which can save the power semiconductor device from voltage and current across each power device. The proposed soft switching circuits have only two active power semiconductor devices. These ARCPL and ARDCL circuits consist of fewer parts than the conventional soft switching circuit. Furthermore, the proposed 3-phase voltage source soft switching AC-DC-AC power conversion system needs no additional sensor for complete soft switching as compared with the conventional 3-phase voltage source AC-DC-AC power conversion system. In addition to this, these soft switching circuits operate only once in one sampling term. Therefore, the power conversion efficiency of the proposed AC-DC-AC converter system will get higher than a conventional soft switching converter system because of the reduced ARCPL and ARDCL circuit losses. The operation timing and terms for ARDCL and ARCPL circuits are calculated and controlled by the smoothing DC capacitor voltage and the output AC current. Using this control, the loss of the soft switching circuits are reduced owing to reduced resonant inductor current in ARCPL and ARDCL circuits as compared with the conventional controlled soft switching power conversion system. The operating performances of proposed soft switching AC-DC-AC converter treated here are evaluated on the basis of experimental results in a 50kVA setup in this paper. As a result of experiment on the 50kVA system, it was confirmed that the proposed circuit could reduce conduction noise below 10 MHz and improve the conversion efficiency from 88. 5% to 90.5%, when compared with the hard switching circuit.

직접전력변환 방식을 이용한 전압 강하/상승 보상기의 구현 (Implementation of Voltage Sag/Swell Compensator using Direct Power Conversion)

  • 이상회;차한주;한병문
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1544-1550
    • /
    • 2009
  • In this paper, a new single phase voltage sag/swell compensator using direct power conversion is proposed. A new compensator consists of input/output filter, series transformer and direct ac-ac converter, which is a single-phase back-to-back PWM converter without dc-link capacitors. Advantages of the proposed compensator include: simple power circuit by eliminating dc link electrolytic capacitors and thereby, improved reliability and increased life time of the entire compensator; simple PWM strategy or compensating voltage sag/swell at the same time and reduced switching losses in the ac-ac converter. Further, the proposed scheme is able to adopt simple switch commutation method without requiring complex four-step commutation method that is commonly employed in the direct power conversion. Simulation and experimental results are shown to demonstrate the advantages of the new compensator and PWM strategy. A 220V, 3kVA single-phase compensator based on the digital signal processor controller is built and tested.

AWGN 채널환경에서 Direct-Conversion 수신기의 성능분석에 관한 연구 (A Study on a Performance Analysis of Direct-Conversion Receiver In Additive White Gaussian Noise Channel)

  • 조형래;김철성;박성진
    • 한국정보통신학회논문지
    • /
    • 제5권4호
    • /
    • pp.668-675
    • /
    • 2001
  • 최근, 상업적인 pcs시스템은 매우 발전되어 있으며, 결국 차세대 이동통신은 멀티미디어 서비스를 제공하는 IMT-2000에 의해 실현될 것이다. 그러므로 , 새로운 형태의 수신 시스템 연구가 활발히 진행되고 있고, 이중하나가 Direct conversion 방식이다 Direct conversion은 차세대 이동통신 시스템에 필요한 저전력, 소형, MMIC, 저가에 적합한 방식이다. 이 시스템을 사용할 경우 DC-offset의 문제가 발생하게 된다. DC-offset은 시스템에서 주파수 합성기의 누설신호에 의해 원하는 신호의 증폭을 억압한다. 본 논문에서 DC-offset을 제거하는 방법에 대해 고려한다. DC-offset의 제거법에는 AC-coupling, 대용량 capacitor, DC-feedback loop, DC-free coding의 4가지 방법이 있다. 이중에서 AC-coupling법은 가장 간단하며, DC-feedback법은 최고의 성능을 가진다. AC-coupling법과 DC-feedback법을 HP사의 ADS를 사용하여 시뮬레이션 하였다.

  • PDF

Single-Phase Voltage-Fed Z-Source Matrix Converter

  • Fang, Xupeng;Liu, Jie
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권2호
    • /
    • pp.46-52
    • /
    • 2012
  • This paper proposes a novel single-phase ac-ac converter topology based on the Z-source concept. The converter provides buck-boost function and plays the role of frequency changer. Compared to the traditional ac-dc-ac converter, it uses fewer devices, realizes direct ac-ac power conversion, and has a simpler circuit structure, so as to have higher efficiency and better circuit characteristics. Compared to the traditional matrix converter, it provides a wider voltage regulation range. The circuit topology, operating principle, control method and simulation results are given in this paper, and the rationality and feasibility is verified.

Wireless Energy Transmission High-Efficiency DC-AC Converter Using High-Gain High-Efficiency Two-Stage Class-E Power Amplifier

  • Choi, Jae-Won;Seo, Chul-Hun
    • Journal of electromagnetic engineering and science
    • /
    • 제11권3호
    • /
    • pp.161-165
    • /
    • 2011
  • In this paper, a high-efficiency DC-AC converter is used for wireless energy transmission. The DC-AC convertter is implemented by combining the oscillator and power amplifier. Given that the conversion efficiency of a DC-AC converter is strongly affected by the efficiency of the power amplifier, a high-efficiency power amplifier is implemented using a class-E amplifier structure. Also, because of the low output power of the oscillator connected to the input stage of the power amplifier, a high-gain two-stage power amplifier using a drive amplifier is used to realize a high-output power DC-AC converter. The high-efficiency DC-AC converter is realized by connecting the oscillator to the input stage of the high-gain high-efficiency two-stage class-E power amplifier. The output power and the conversion efficiency of the DC-AC converter are 40.83 dBm and 87.32 %, respectively, at an operation frequency of 13.56 MHz.

DC-Offset 간섭환경에서 AC-Coupling을 갖는 직접변환 수신기의 성능 (Performance of Direct-Conversion Receiver with AC-Coupling in DC-Offset interference environment)

  • 성봉훈;송윤정;김영완;김내수;서종수
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2002년도 정기총회 및 학술대회
    • /
    • pp.9-14
    • /
    • 2002
  • Direct-conversion receiver(DCR) architecture has superior advantages in size, cost, and power over superheterodyne receiver architectures. However, the use of direct-conversion receiver architecture has been limited due to the direct-current offset noise. The ac coupling, which is used to overcome the direct-current offset noise, causes an inter-symbol interference(ISI), whose effects can be effectively mitigated using an equalizer. In this paper, the performance of a direct-conversion receiver with ac coupling in the presence of direct-current offset is analyzed via computer simulation. The simulation result shows that by using decision feedback equalizer with LMS(Least Mean Square) algorithm, signal-to-noise ratio loss of the direct-conversion receiver compared to the idea receiver can be reduced to less than 1㏈ for corner frequencies as large as 10% of the symbol rate.

  • PDF

계통연계형 가변속 풍력발전방식의 PSCAD/EMTDC 모의 및 해석 (PSCAD/EMTDC BASED MODELING AND ANALYSIS OF A GRID-CONNECTED VARIABLE SPEED WIND ENERGY CONVERSION SCHEME)

  • 김슬기;김응상
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권8호
    • /
    • pp.413-419
    • /
    • 2003
  • The paper presents a simulation model and analysis of a grid-connected variable speed wind energy conversion scheme (VSWECS) using the PSCAD/EMTDC software. The modeled system uses a variable speed drive, a fixed pitch angle, a synchronous generator as a wind generator and an AC-DC-AC conversion scheme, which facilitates the wind generation to efficiently operate under varying wind speed while connected to the distribution network. The power output of the WECS is controlled by the AC-DC-AC conversion scheme, the objective of which is to capture the maximum active power under varying wind conditions and to keep the voltage magnitude of the terminal bus at a specific level. Aerodynamic models are applied for a wind turbine model. An simulation analysis of the scheme in terms of its responding to wind variations is also presented.