• 제목/요약/키워드: Abutting

검색결과 31건 처리시간 0.028초

Differential Expression of Amelogenin, Enamelin and Ameloblastin in Rat Tooth Germ Development

  • Kim, Jung-Ha;Kim, Hyun-Jin;Kim, Byong-Soo;Kang, Jee-Hae;Kim, Min-Seok;Lee, Eun-Joo;Kim, Sun-Hun
    • International Journal of Oral Biology
    • /
    • 제41권2호
    • /
    • pp.89-96
    • /
    • 2016
  • Tooth development shows dynamic morphological changes from the stages of cap to hard tissue formation and is strictly regulated during development. In the present study, we compared expression and localization of 3 major enamel matrix proteins in rats: amelogenin, enamel and ameloblastin. DD-PCR and RT-PCR revealed differential expression of the major proteins from the cap stage to root stage. Immunofluorescence staining results indicated that amelogenin was not detected in either inner enamel epithelium or reduced enamel epithelium, but highly immunoreactive in preameloblasts and ameloblasts; in addition, it was sporadically expressed in preodontoblasts abutting preameloblasts. Ameloblastin expression was also observed in not only differentiated ameloblasts but also osteoblasts. Immunoreactivity to ameloblastin in ameloblasts was strong in Tomes' processes. Enamelin was exclusively localized along the entire newly formed and maturing enamel. Enamelin was largely localized in near Tomes' processes and enamel rods in maturing enamel. Alendronate treatment resulted in down-regulation of amelogenin and ameloblastin at both transcription and translation levels; whereas, enamelin expression was unchanged in response to the treatment. These results suggested that amelogenin, ameloblastin and enamelin might be implicated in cell differentiation, adhesion of ameloblasts to enamel and enamel crystallization during enamel matrix formation, respectively.

뼈주위 지방종의 자기공명영상 소견: 증례 보고 (MR Imaging Findings of Parosteal Lipoma: Case Report)

  • 배형주;홍석주;김예림;강은영;김학준;류영준;정원용
    • Investigative Magnetic Resonance Imaging
    • /
    • 제14권2호
    • /
    • pp.134-138
    • /
    • 2010
  • 뼈주위 지방종은 골막과 밀접한 관련성을 지니며 발생하는 드문 양성지방종으로 조직소견은 전형적인 연부조직 지방종과 같은 성숙지방세포로 구성된다. 영상에서 특징적으로 뼈와 인접한 지방성의 덩어리로 나타나며 인접한 골피질에 다양한 반응성 변화를 일으킨다. 자기공명영상에서는 뼈주위에 위치한 양성지방종, 이와 연결된 뼈의 돌기 또는 반응성 골피질 변화, 또한 신경 압박에 의한 이차적 근육 퇴행 등의 소견을 관찰할 수 있다. 이 보고에서는 중족골에 연해 발생한 뼈주위 지방종의 증례를 자기공명영상 소견을 중심으로 기술하고자 한다.

Evaluation of Glucose Dehydrogenase and Pyrroloquinoline Quinine (pqq) Mutagenesis that Renders Functional Inadequacies in Host Plants

  • Naveed, Muhammad;Sohail, Younas;Khalid, Nauman;Ahmed, Iftikhar;Mumtaz, Abdul Samad
    • Journal of Microbiology and Biotechnology
    • /
    • 제25권8호
    • /
    • pp.1349-1360
    • /
    • 2015
  • The rhizospheric zone abutting plant roots usually clutches a wealth of microbes. In the recent past, enormous genetic resources have been excavated with potential applications in host plant interaction and ancillary aspects. Two Pseudomonas strains were isolated and identified through 16S rRNA and rpoD sequence analyses as P. fluorescens QAU67 and P. putida QAU90. Initial biochemical characterization and their root-colonizing traits indicated their potential role in plant growth promotion. Such aerobic systems, involved in gluconic acid production and phosphate solubilization, essentially require the pyrroloquinoline quinine (PQQ)-dependent glucose dehydrogenase (GDH) in the genome. The PCR screening and amplification of GDH and PQQ and subsequent induction of mutagenesis characterized their possible role as antioxidants as well as in growth promotion, as probed in vitro in lettuce and in vivo in rice, bean, and tomato plants. The results showed significant differences (p ≤ 0.05) in parameters of plant height, fresh weight, and dry weight, etc., deciphering a clear and in fact complementary role of GDH and PQQ in plant growth promotion. Our study not only provides direct evidence of the in vivo role of GDH and PQQ in host plants but also reveals their functional inadequacy in the event of mutation at either of these loci.

Percutaneous Ultrasound-Guided Fine-Needle Aspiration Cytology and Core-Needle Biopsy for Laryngeal and Hypopharyngeal Masses

  • Dongbin Ahn;Gil Joon Lee;Jin Ho Sohn;Jeong Eun Lee
    • Korean Journal of Radiology
    • /
    • 제22권4호
    • /
    • pp.596-603
    • /
    • 2021
  • Objective: To evaluate the feasibility and diagnostic performance of ultrasound (US)-guided fine-needle aspiration cytology and core-needle biopsy (US-FNAC/CNB) for the diagnosis of laryngo-hypopharyngeal masses. Materials and Methods: This was a single-center prospective case series. From January 2018 to June 2019, we initially enrolled 40 patients with highly suspicious laryngo-hypopharyngeal masses on laryngoscopic examinations. Of these, 28 patients with the mass involving or abutting the pre-epiglottic, paraglottic, pyriform sinus, and/or subglottic regions were finally included. These patients underwent US examinations with/without subsequent US-FNAC/CNB under local anesthesia for evaluation of the laryngo-hypopharyngeal mass. Results: Of the 28 patients who underwent US examinations, a laryngo-hypopharyngeal mass was identified in 26 patients (92.9%). US-FNAC/CNB was performed successfully in 25 of these patients (96.2%), while the procedure failed to target the mass in 1 patient (3.8%). The performance of US caused minor subclinical hematoma in 2 patients (7.7%), but no major complications occurred. US-FNAC/CNB yielded conclusive results in 24 (96.0%) out of the 25 patients with a successful procedure, including 23 patients with squamous cell carcinoma (SCC) and 1 patient with a benign mass. In one patient with atypical cells in US-FNAC, additional direct laryngoscopic biopsy (DLB) was required to confirm SCC. Among the 26 patients who received US-FNAC/CNB, the time from first visit to pathological diagnosis was 7.8 days. For 24 patients finally diagnosed with SCC, the time from first visit to the initiation of treatment was 25.2 days. The mean costs associated with US-FNAC/CNB was $272 under the Korean National Health Insurance Service System. Conclusion: US-FNAC/CNB for a laryngo-hypopharyngeal mass is technically feasible in selected patients, providing good diagnostic performance. This technique could be used as a first-line diagnostic modality by adopting appropriate indications to avoid general anesthesia and DLB-related complications.

Cone-Beam CT-Guided Percutaneous Transthoracic Needle Lung Biopsy of Juxtaphrenic Lesions: Diagnostic Accuracy and Complications

  • Wonju Hong;Soon Ho Yoon;Jin Mo Goo;Chang Min Park
    • Korean Journal of Radiology
    • /
    • 제22권7호
    • /
    • pp.1203-1212
    • /
    • 2021
  • Objective: To investigate the diagnostic accuracy and complications of cone-beam CT-guided percutaneous transthoracic needle biopsy (PTNB) of juxtaphrenic lesions and identify the risk factors for diagnostic failure and complications. Materials and Methods: In total, 336 PTNB procedures for lung lesions (mean size ± standard deviation [SD], 4.3 ± 2.3 cm) abutting the diaphragm in 326 patients (189 male and 137 female; mean age ± SD, 65.2 ± 11.4 years) performed between January 2010 and December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the PTNB procedures for the diagnosis of malignancy were measured based on the intention-to-diagnose principle. The risk factors for diagnostic failures and complications were evaluated using logistic regression analysis. Results: The accuracy, sensitivity, specificity, PPV, and NPV were 92.7% (293/316), 91.3% (219/240), 91.4% (74/81), 96.9% (219/226), and 77.9% (74/95), respectively. There were 23 diagnostic failures (7.3%), and lesion sizes ≤ 2 cm (p = 0.045) were the only significant risk factors for diagnostic failure. Complications occurred in 98 cases (29.2%), including 89 cases of pneumothorax (26.5%) and 7 cases of hemoptysis (2.1%). The multivariable analysis showed that old age (> 65 years) (p = 0.002), lesion size of ≤ 2 cm (p = 0.003), emphysema (p = 0.006), and distance from the pleura to the target lesion (> 2 cm) (p = 0.010) were significant risk factors for complications. Conclusion: The diagnostic accuracy of cone-beam CT-guided PTNB of juxtaphrenic lesions for malignancy was fairly high, and the target lesion size was the only significant predictor of diagnostic failure. Complications of cone-beam CT-guided PTNB of juxtaphrenic lesions occurred at a reasonable rate.

방사선 세기 조절 치료에서 선량을 규명하는 데 사용된 BlnS System의 특성 (The Properties of Beam Intensity Scanner (BInS) for Dose Verification in Intensity Modulated Radiation Therapy)

  • 박영우;박광열;박경란;권오현;이명희;이병용;지영훈;김근묵
    • 한국의학물리학회지:의학물리
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2004
  • 방사선 치료과정에서 가장 중요한 것은 환자에게 조사된 흡수선량을 검증하는 것이다. IMRT에 사용되는 방사선의 물리적 특성을 결정하고 환자에 조사된 선량분포를 검증할 수 있는 정밀한 선량 측정 장치가 필요하다. 본 연구에서 2차원 광자선의 선량검증을 위해 만들어진 BInS (Beam Intensity Scanner)에 관하여 논의한다. BInS에 있는 Scintillator는 광자선이나 전자선에 조사되면 형광을 발생하는 Gd$_2$O$_2$S:Tb를 주성분으로 한다. Scintillator에서 발생된 형광은 디지털 비디오카메라에 의해 수집되어 디지털 신호로 바뀌고 자체 제작한 소프트웨어에 의해 분석되며 상대적인 선량 분포가 3차원 그림으로 표시된다. BInS가 IMRT에서 사용가능한지를 알아보기 위하여 치료에 관련된 몇 가지 측정을 하였다. IMRT의 주요 작동방식 중의 하나인 SMLC (static multileaf collimator) 방식에서는, leaf들의 동작을 통제하여 만들어지는 여러 개의 정적 조사면적(static portal)을 통하여 IMB (intensity modulated beam)이 만들어진다. 따라서 여러 개의 정적 조사면적이 연달아 맞닿아 있는 경우, 연속된 두 조사면적의 경계면에서 penumbra와 산란된 광자들이 겹쳐지고 따라서 hot spot이 생기게 된다. 이와 같이 SMLC 방식에서 나타나는 inter-step hot spot들의 존재를 BInS를 이용하여 측정하여 가시화하였고 또한 그것들을 제거하는 실험적 방법도 제시하였다. IMRT에서 사용되는 다른 주요한 작동방식인 DMLC (dynamic multileaf collimator)는 광자선이나 전자선을 제어하는 leaf의 작동방식이 다르기 때문에 SMLC 방식과는 다른 특성을 보인다. 따라서 BInS를 이용하여 SMLC와 DMLC 방식에 의해 실제로 target에 투사된 선량을 측정 비교하였다. 비록 같은 선량을 target 부위에 투사하기로 계획했을지라도, 실제로는 산란된 광자와 전자들 때문에 DMLC 방식에 의한 선량이 SMLC 방식에 의한 선량보다 14.8%나 큰 것으로 측정되었다.

  • PDF

경상누층군 퇴적암의 절리 특성 연구 (Joint Characteristics in Sedimentary Rocks of Gyeongsang Supergroup)

  • 장태우;손병국
    • 지질공학
    • /
    • 제19권3호
    • /
    • pp.351-363
    • /
    • 2009
  • 경상분지 내 구미노두와 다사노두 지역에서 신동층군의 사암층을 대상으로 절리 연구가 집중적으로 이루어졌다. 사암-이암 시퀀스의 양 지역 노두에서 똑같이 두 조의 직교 절리가 사암층에 전형적으로 발달하고 있다. 여러 가지 절리 자료들을 양 지역의 동일한 두께의 층에서 비교하여보면 상당히 유사한데 이는 절리 조들이 동일한 응력장에서 신장 변형 작용으로 균질하게 생성되었음을 이야기 한다. 대부분의 절리들은 퇴적물이 매몰되어 고화되는 과정에서 수압단열작용에 의해 생성된 것으로 생각되며, 사암층의 층 경계에 수직이고 층 경계에 이르러 중지한다. 두 조의 직교하는 절리들은 단열 격자차단 양상으로 해석되는 상호 접경하는 관계로 볼 때 ${\sigma}_1$은 수직으로 고정된 상태에서 ${\sigma}_2$${\sigma}_3$의 빠른 교환에 의해 거의 동시에 생성된 것으로 판단된다. 사암층에서의 절리조들은 인접한 절리 간에 평행한 배향을 가지며 규칙적인 간격을 가지고 절리면은 평탄하다. 절리간격은 층 두께에 비례하고 간격분포는 대부분의 층에서 대수-정규분포 내지 정규 분포를 나타낸다. 그러나 다중층에서는 간격의 분포범위가 크고 불규칙한 형태를 보여준다. 연구지역에서 두 조의 절리들은 최빈값/평균값의 비가 1 내외로 포화상태를, 또 다른 척도인 변동계수(Cv)도 1이하의 낮은 값으로 포화를 지시한다. 절리의 개구는 모든 사암충의 절리에서 균질하기보다는 절리의 길이가 증가함에 따라 증가하는 경향을 갖는다.

Salsola collina 엽육조직내 변형된 크란츠구조 (Modified Kranz Structure in Leaves of Salsola collina)

  • 김인선
    • Applied Microscopy
    • /
    • 제31권2호
    • /
    • pp.207-214
    • /
    • 2001
  • Salsola callina 엽육조직의 $C_4$ Kranz구조내 세포유형의 발달 및 미세구조 분화특성을 연구하였다. 선형의 다육질성 잎은 표피, 광합성 염육조직, 수분저장조직, 유관속으로 이루어져 있으며, 두 층의 엽육조직은 변형된 Salsoloid Kranz구조를 나타내었다. 내부의 엽육조직층은 전형적인 $C_4$ 구조의 Kranz 유관속초세포의 특성을 보이고, 외부의 엽육세포층은 Kranz 엽육세포의 특성을 보였다. 세포소기관들은 유관속초 세포에서는 구심적으로 배열하였고 엽육세포에서는 세포벽 주위를 따라 분포하였다. 또한 이들 세포유형 사이에는 엽록체 이형현상이 뚜렷하여 유관속초세포의 엽록체는 전분입자가 잘 발달하고 그라나가 거의 형성되어 있지 않았다. 반면, 외부엽육세포의 엽록체에는 그라나와 proteinbody들이 잘 발달되어 있었다. 유관속초세포의 세포벽은 비후되어 있으나 엽육세포의 경우에는 얇고, 특히 이들 두 세포층은 복잡한 구조를 지니는 원형질연락사로 연결되어 있었다. 이러한 구조들은 $C_4$ 광합성과정에서 생성되는 물질이 유관속초세포와 엽육세포 간에 원활하게 수송되고 이동됨을 암시한다. 본 연구에서 밝혀진 Salsola 식물의 미세구조는 $C_4$ 식물의 NADP-ME유형의 구조적 특성과 거의 일치하는 것이며, 구조적 이형현상을 보이는 유관속초와 엽육세포 간의 특성은 엽육조직 분화시 $C_4$ 기능과 밀접하게 연계하여 적응한 결과로 나타난 현상으로 추정된다.

  • PDF

다중 조사면 치료 시 기계적 입력치(MU)에 따른 선량적 안정성에 대한 연구 (A Study of Dose Stability at Low Monitor Unit Setting for Multiple Irradiated Field)

  • 김주호;이상규;신현경;이석;나수경;조정희;김동욱
    • 대한방사선치료학회지
    • /
    • 제17권2호
    • /
    • pp.155-160
    • /
    • 2005
  • 목 적 : 전산화단층 모의치료조준(CT simulation)과 선량 계획 장비(RTP)의 발전으로 많은 저자들에 의해 종양부 위의 선량을 증가시키고 인접한 장기의 선량을 효과적으로 감소시킬 수 있는 3차원 입체 조형 치료(Conformal therapy)와 조사면내 선량 보강 기법(Field in field technique)이 자주 소개되어지고 있다. 이러한 치료 기법은 많은 수의 조사면을 사용함으로써 조사면이 증가할수록 10 MU이하의 극히 적은 기계적 입력치(monitor unit, MU)를 사용하기도 한다. 통상 일반적으로 사용되어지는 선량에 대한 정보(beam data)는 이보다 훨씬 많은 100 MU이상 혹은 그보다 높은 안정적인 출력을 기대할 수 있는 상태에서 측정되어지므로 극히 적은 기계적 입력치에서도 기존에 측정되어진 선량 정보와 동일한 선량분포를 구현할 수 있는지 반드시 확인하여야 한다. 따라서 본 연구에서는 극히 적은 기계적 입력치(MU)에서의 선량적 안정성을 알아보고 향후 정도 관리지침에 활용코자 한다. 대상 및 방법 : 본원에서 사용 중인 선형가속기 Varian 2100C/D의 6 MV, 10 MV(USA)와 Varinan 600C의 4 MV(USA)의 에너지를 사용하여 $10{\times}10cm^2$ 조사면에서 90 MU를 90 MU, 45 MU, 30 MU, 18 MU, 9 MU, 6 MU로 각각 1, 2, 3, 5, 10, 15 회씩 나누어 조사하였다. 전리함(pinpoint farmer type chamber, PTW, GERMANY)를 이용하며 4 MV, 6 MV는 5 cm, 10 MV는 10 cm 깊이, SAD 100 cm에서 물 팬텀을 이용하며 조사면내의 출력을 측정하였고, 측정용 필름(X-omat V, Kodak, USA)을 이용하며 높은 선량을 나타내는 90 MU, 30 MU에서의 편평도와, 대칭도를 비교하였고 일반적인 medical film(AGFA USA)을 이용하여 낮은 선량을 보이는 9MU에서 조사면내 편평도와, 대칭도를 비교하여 선질의 특성 변화를 관찰하였다. 결 과 : 전리함을 이용한 측정에서 2100C/D는 90 MU와 9 MU에서 1 MU 당 선량(cGy/MU)은 6 MV와 10 MV에서 90 MU를 1회에 조사한 것과 비교하여 약 1.6% 정도 증가하였고 2100C는 0.5%, 1.3%가 각각 증가하였다. 600C 또한 1.6% 증가하였으나 6 MU에서 약 3% 차이를 나타내었다. 편평도와 대칭도는 장비와 에너지에 따라 1%에 2.9%까지 차이가 있었으나 전체적으로 적은 MU에서 약간 더 균등하였고 극히 적은 MU로 인한 차이는 확인할 수 없었다. 결 론 : 각각의 실험에서 선량적 차이는 허용되어지는 범위이하의(출력<3%, 편평도<${\pm}3%$, 대칭도<2%, ICRU report 50)오차를 모임으로써 보유한 장비에 따라 정도에 차이는 있을 수 있으나 본원에서 사용 중인 장비에서 극히 적은 MU의 사용이 현저한 선량적 오차를 유발하진 않는 것으로 사료되어진다. 그러나 정도 관리 시 그 오차를 확인하는 과정은 장비의 사용과 수명에 따라 지속적으로 관리되어져야 할 것이다.

  • PDF

양전자방출단층촬영술(PET)을 이용한 식도암 환자의 병기 결정 -전산화단층촬영술(CT)과의 비교- (Staging of Esophageal Cancer Using Positron Emission Tomography : Comparing to Computed Tomography)

  • 심영목;박승준;김병태;김성철
    • Journal of Chest Surgery
    • /
    • 제32권4호
    • /
    • pp.388-393
    • /
    • 1999
  • 배경: 식도암 치료에 있어서 수술전 병기 결정은 매우 중요하다. 특히 절제 가능성을 알기 위해서 흉부 단층 촬영과 내시경등 여러 방법을 사용하고 있지만 어떤 검사도 충분한 정보를 제공하지 못하고 있다. 이에 식도암 환자의 병기 결정에 있어서 양전자방출단층촬영의 역할을 알아보고자 연구를 실시하였다. 대상 및 방법: 1997년 1월부터 10월까지 내시경을 통한 조직 검사상 식도 편평 상피암으로 확진된 20명(남 19명, 여 1명, 평균연령 61세)의 환자에서 림프절절제를 포함한 근치적 절제를 시행한 후, 수술전 [F-18]FDG-PET 및 CT 소견과 수술 후 조직 병리 소견을 비교하였다. 결과: 원발 종양 진단에 대한 PET와 CT의 민감도는 90%로 동일하였다. PET와 CT 모두 1 cm 크기의 상피내암종 1예와 T1 병기의 종양 1예에 대하여 위음성을 보였다. 총193개의 절제된 림프절군에 대한 병리 조직 검사 결과를 바탕으로 PET와 CT의 민감도, 특이도, 정확도를 구하였으며 결과는 다음과 같았다.(*$\chi$2 p < 0.005) 민감도** 특이도 정확도* PET 55.6%(30/54) 97.1%(135/139) 85.5%(165/193) CT 13.0%(7/54) 98.6%(137/139) 74.6%(144/193) PET에서 위양성 림프절 전이를 보였던 4명중 1명의 환자는 활동성 폐결핵을 동반한 환자였으며, PET에서 위음성을 보였던 24개의 림프절군중 14개는 감쇠보정을 실시하지 않은 부위에, 5개는 원발 종양과 근접한 부위에 있었다. 결론: PET에서 위양성 림프절 전이를 보였던 4명중 1명의 환자는 활동성 폐결핵을 동반한 환자였으며, PET에서 위음성을 보였던 24개의 림프절군중 14개는 감쇠보정을 실시하지 않은 부위에, 5개는 원발 종양과 근접한 부위에 있었다. 결론: 이상과 같은 결과로부터 [F-18]FDG-PET는 식도암의 림프절 전이 및 병기를 결정하는데 있어서 CT의 결점을 보완할 수 있는 유용한 진단 방법임을 알 수 있었다.

  • PDF