• Title/Summary/Keyword: Abutment teeth

Search Result 181, Processing Time 0.024 seconds

Roentgenologic Studies on the Periodontal Ligaments and Alveolar Bone Changes in Various Prosthesis (보철물(補綴物) 장착시(裝着時) 치근막(齒根膜)과 치조골(齒槽骨)의 변화(變化)에 관(關)한 X선학적(線學的) 연구(硏究))

  • Lee, Jae-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.9 no.1
    • /
    • pp.17-22
    • /
    • 1969
  • Intra-oral films of 155 patients were taken on the areas of Gold Crown-Bridges, S. P. Bridges and Partial Dentures. And the author observed periodontal ligaments widening rates, the presence of periapical lesions and the alveolar bone patterns on the Partial Denture Saddle portions. The results were as follows : 1. Periodontal ligaments a) Periodontal ligaments widening rate increased obviously with the duration of wearing those prosthetic appliances. b) Periodontal ligaments widening rate was the highest in partial denture wearing patients, and then that of S. P. Crown Bridge patients, Gold Crown Bridge wearing females, Gold Crown Bridge males were the sequences. 2. Periapical lesions a) Periapical lesions increased with the wearing duration of those prosthetic appliances. But they did not increase in proportion to the duration. Periapical lesions were about the same in the teeth with those appliances showing relatively higher rate in Partial Denture abutment teeth and the lowest in Gold-Bridge abutment teeth. 3. Alveolar bone of Partial Denture saddle portion One third of all(32%) were normal with their smooth and compact bone pattern so that they were considered to perform normal function.

  • PDF

A Comparative Study of Periodontal Conditions Following insertion of Distally Extending Cantilever Bridges or Removable Partial Dentures (후방연장 계속가공의치와 가철성 국소의치 지대치의 치주조직 상태에 관한 비교)

  • Kim, Chung-Chan;Choi, Kwang-Choon;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.2
    • /
    • pp.352-357
    • /
    • 1993
  • The purpose of the present study was to evaluate and compare the periodontal conditions of distally extending cantilever bridges(CB) and removable patial dentures(RPD). 78 patients treated with removable partial dentures were divided into 2 groups; bilateral free-ending (type 1) and unilateral free-ending(type 2). 43 patients treated with distally extending cantilever bridges were divided into 4 groups according to position of missing molars and number of including abutment tooth (or teeth) (type 1-4). Prosthodontic status of the abutment teeth were assessed; overcontoured crown, overhanged margin, embrasure closure, and others. Their Periodonted status were assessed with Plaque Index Gingial Index(GI) Sulcus bleedy Index (SBI), Tooth mobility(TM) & Posher depth(PPD). 35.9% of RPD group and 38.1 of CB grouphad disconfort on mastication with prosthetics. 16.7% of RPD group and 6.1% of CB group showed on opposing sites. Overhanged margins were 58.3% for RPD group and 86.6% for GB group. 45.5% of RPD group and 72% of CB group had embrasure closure on the abutment teeth. 30.5% of GB group had oversized pontic. Gb group showed much higher clinical parameters than RPD groups, but statistically not significant. Type 2 of RPD group showed lower GI and SBI, but statistically not significant. Type 3 of CB group showed the highest GI and SBI and type 2 showed the highest tooth mobility, but there is no differences between the same type of groups. In conclusion, only minor differences in periodontal conditions were recorded in RPD and CB group.

  • PDF

Evaluation of internal adaptation of PMMA 3-unit bridge manufactured by 5-axis milling machine (5축 밀링으로 가공한 PMMA 3본 브릿지의 내면 적합도 평가)

  • Kim, Chong-Myeong;Kim, Jae-Hong;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.38 no.2
    • /
    • pp.63-68
    • /
    • 2016
  • Purpose: The purpose of this study was to assess the internal fitness of the PMMA 3-unit bridge that was fabricated with 5-axis milling machine and to verify the clinically allowable values. Methods: For fabrication of the crown bridge in this study, 25-27 abutment teeth were used. The prepare abutment teeth were scanned with a scanner and 3-unit bridge was designed by using design software. Upon the completion of the design, the 3-unit bridge was fabricated by using a PMMA block with 5-axis milling machine. The internal surface of the fabricated 3-unit bridge was scanned by using a scanner and the difference between the 3-unit bridge and the abutment teeth was assessed by merging them together. Results: $RMS{\pm}SD$ values for PRE group, MOL group, and BRI group were $51.2{\pm}18.2$, $44.8{\pm}10.0$, and $52.1{\pm}8.3{\mu}m$, respectively. The mean of the PRE group was bigger than that of the MOL and BRI group; however, statistically significant difference was not found (p>0.05). Conclusion: The PMMA 3-unit bridge that was fabricated with 5-axis milling machine presented stable internal values for each crown and overall internal values were within the range of clinically allowable values.

DESIGN AND FABRICATION OF INNER KONUS CROWN USING THREE DIMENSIONAL COMPUTER GRAPHICS (3차원 컴퓨터 그래픽 기술을 이용한 KONUS 내관의 설계와 제작)

  • Kim, In-Sup;Kim, Byung-Oh;Yoo, Kwan-Hee;Kang, Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.4
    • /
    • pp.544-551
    • /
    • 2000
  • A fabrication method of inner and outer crown using CAD/CAM is presented. The information of abutment teeth is transferred to a computer through a 3-dimensional scanner. A Konus inner and outer crown is designed on a computer and a real crown is machined based on this design using CAM. This method can save laboratory time and reduce inaccuracies compare to conventional casting procedure. A stone model with six prepared abutment teeth from a patient was used in this study. Three dimensional information from the model was transferred to a computer using a contact type 3-dimensional scanner with a $25{\mu}m$ accuracy. All margins were identified on a computer image where there is a change in surface taper of a model. To provide a cement space, the image of a inner sur face of a Konus inner crown was duplicated $25{\mu}m$ apart from the surface of a prepared abutment teeth image. The cement space was $20{\mu}m$ at the cervical margin. All Konus crowns were machined with a $10{\mu}m$ accuracy. It was concluded that this method can reduce working-time for the laboratory process and increase accuracy. A further research is required to make a simplified process for a more complex prosthesis.

  • PDF

Fabrication of implant-associated obturator after extraction of abutment teeth: a case report (지대치 발거 후 임플란트 연관 상악 폐색장치 제작 증례보고)

  • Ki-Yeol Jang;Gyeong-Je Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.229-236
    • /
    • 2023
  • Maxillary bone defects may follow surgical treatment of benign and malignant tumors, trauma, and infection. Palatal defects often lead to problems with swallowing and pronunciation from the leakage of air into the nasal cavity and sinus. Obturators have been commonly used to solve these problems, but long-term use of the device may cause irritation of the oral mucosa or damage to the abutment teeth. Utilizing implants in the edentulous area for the fabrication of the obturators has gained attention. This case report describes a patient, who had undergone partial resection of the maxilla due to adenocarcinoma, in need of a new obturator after losing abutment teeth after long-term use of the previous obturator. Implants were placed in strategic locations, and an implant-retained maxillary obturator was fabricated, showing satisfactory results in the rehabilitation of multiple aspects, including palatal defect, masticatory function, swallowing, pronunciation, and aesthetics.

Food impaction related with trauma from occlusion (임플란트 보철물의 식편압입: 교합적 원인분석과 대처)

  • Cho, Lee-Ra
    • The Journal of the Korean dental association
    • /
    • v.52 no.8
    • /
    • pp.491-505
    • /
    • 2014
  • Food impaction between the implant prostheses and adjacent teeth is the most frequently observed problem. It may be caused by the migration of the adjacent teeth. This symptom may be observed at the mesial aspect of implant prostheses especially, and related with the multiple contributing factors including teeth vitality and antagonist. Idal proximal contact with optimal strength and shape should be made for preventing the food impaction. Shape of customized abutment and prosthesis should have optimal emergence profile. Long duration from the extraction to the delivery of implant prostheses, the adjacent teeth and antagonist teeth may have possibility of occlusal interferences. Remained teeth mobility can induce the food impaction regardless of interproximal contact strength. Occlusal adjustment to remove occlusal interferences can be a method for enhancing the stability of interproximal contact.

Marginal Adaptation of Zirconium Dioxide Core according to the Abutment Teeth (지대치 형태에 따른 지르코니아 코어의 변연 적합도)

  • Kim, Ki-Baek;Kim, Seok-Hwan;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.15 no.1
    • /
    • pp.54-59
    • /
    • 2015
  • The present study investigated the influences of various abutment teeth shapes (maxillary right canine, pre-molar, molar) on the marginal adaptation of computer aided design/computer aided manufacturing-fabricated zirconia core. In vitro adaptation of zirconia cores manufactured by three different abutments were evaluated. Thirty zirconia cores were made per each models and the adaptation was evaluated through a silicone replica technique. The measurement of the adaptation was carried out using digital microscope. The mean and standard deviation of each reference point were analyzed using the one-way (ANOVA) and Tukey's honestly significant difference tests (${\alpha}=0.05$). The overall marginal fits of the zirconia cores were as follows: canine: $47.59{\mu}m$, pre-molar: $43.74{\mu}m$, molar: $40.36{\mu}m$. They were no statistically significant differences between groups for adaptation (p>0.05). This confirmed that the type of abutment teeth used does not determine the precision of fit of zirconia core.

FINITE ELEMENT ANALYSIS OF STRESS PATTERNS ON PERIODONTIUM OF SPLINTED ABUTMENTSFOR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE (후방연장 국소의치에서 지대치의 splinting에 따른 치주조직의 응력 변화에 관한 유한요소법적 연구)

  • Hwang, Jae-Woong;Chang, Ik-Tae;Kim, Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.241-268
    • /
    • 1995
  • Splint therapy, the immobilization of teeth, has been done for patient's masticatory comforts and an adjunctive aid in periodontal therapy. Mandibular premolars are frequently splinted in many distal extension removable partial denture cases. But splinting is an extensive restoration that may not be conservative of tooth structure and may prove to be quite costly to the patient. The two dimensional finite element analysis method was used to determine the magnitude and mode of distribution of the stresses of the periodontal ligament and supporting alveolar bone when abutments with different periodontal supports were splinted and distal-extension removable partial denture was subjected to different loading schemes. The results were as follows : 1. When abutments were splinted, stresses moved from apico-distal to apico-mesial of terminal abutment on a vertical force and from disto-alveolar crest to apex on a distally directed force. But stresses were generally diminished on a mesially directed force. 2. As vertical bone loss was proceeding, most of stresses were transmitted to residual ridge and the rest of stresses were concentrated on apex of distal abutment. But these apical stresses were minimized when abutments were splinted. 3. As mesially inclined bone loss was proceeding, it seemed to be dangerous that many stresses were concentrated on the distal alveolar crest, especially in the distally directed load case. Abutments splinting decreased the alveolar crestal stresses but not enough. 4. For all vertical stresses were effectively decreased on splinting, stresses were concentrated as highly on apico-mesial area of distal abutment in distally directed load cases as the distal inclination of bone level was severe. 5. The directions and magnitudes of abutment movements were decreased with teeth splinting.

  • PDF