• 제목/요약/키워드: Absorption performance

검색결과 1,485건 처리시간 0.021초

낙하충격실험을 통한 고무의 충격흡수성능과 전단계수 평가 (Determination of Shock Absorption Performance and Shear Modulus of Rubbers by Drop Impact Test)

  • 강동환;서무열;김학인;김태원
    • 대한기계학회논문집A
    • /
    • 제33권4호
    • /
    • pp.321-328
    • /
    • 2009
  • Shock absorption performances of various rubbers were investigated by using drop impact test. Several types of rubber such as NR, NBR, EPDM, SR and PUR with three respective levels of shore hardness were used for the test. As in the cases, the absorbed impact energies in rubbers were measured under seven different loads against impact energy between 5-80J. The impact absorption efficiencies of the rubbers then were evaluated by means of both single impact energy condition and summation of all impact energy applied condition. As shown in the results, PUR and EPDM have better shock absorption performances than other rubbers. Further analysis was extended to determine a shear modulus of SR through the finite element implementation with Blatz-Ko model. As can be seen, relatively higher level of absorption energy results in a decreasing shear modulus.

수직형 흡수기 최적화에 따른 흡수 성능 예측에 관한 연구 (Study on the Prediction of Absorption Performance by the Optimization of a Vertical Absorber)

  • 김정국;조금남
    • 에너지공학
    • /
    • 제14권3호
    • /
    • pp.194-202
    • /
    • 2005
  • 본 연구는 다양한 수직 액막형 흡수기에서 열 및 물질전달 과정에 따른 흡수 특성 예측을 이론 및 실험적으로 수행하였다. 열 및 물질전달 향상은 해석적으로 조사되었으며, 흡수 성능에 대한 유동 형태, 삽입기구 및 주름에 의한 형상 변수의 영향 등을 조사하였다. 특히, 최대 흡수 성능에 대한 동적 변수(수용액 유량, 유동형태)와 흡수기 형상(ID=22.8mm, L=1150m)의 최적값을 수치 해석적으로 예측하였다 수치 해석 및 실험에서 최대 흡수 성능은 삽입기구(스프링)에 의한 파동 유동에서 나타났다.

흡수기 용액 재순환이 흡수식 냉동기 성능에 미치는 영향 (The Influences of LiBr Solution Recirculation in Absorber on the Absorption Chiller Performance)

  • 정종수;진성민;박찬우;최승학;정봉철
    • 대한기계학회논문집B
    • /
    • 제26권5호
    • /
    • pp.733-741
    • /
    • 2002
  • If a part of the poor solution from the absorber outlet is recirculated to the absorber inlet, the solution temperature at the solution spray pump can be reduced, and the solution flow rate in the absorber is increased. We have performed the experiments on the influences of the absorption chiller performance according to the ratio of the recirculation, defined as the ratio of the recirculation flow rate to the total solution flow rate at the absorber outlet. As increasing the ratio of the recirculation, the absorption capacity of the solution can be deteriorated. On the other hand, due to the increasing flow rate, the heat transfer rate can be enhanced. As a result, the performance of the absorber and the cooling capacity of the absorption chiller have nothing to do with the recirculation ratio, and the lifetime of the spray pump will be maintained.

다공패널형 공명기의 흡음성능에 관한 연구 (A Study on the Absorption Performance of a Perforated Panel type of Resonator)

  • 송화영;양윤상;이동훈
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.224-231
    • /
    • 2016
  • When aiming to reduce the low frequency noise of a subway guest room through sound absorbing treatment methods inside the wall of a tunnel the resonator is often more effective than a porous sound absorbing material. Therefore, the perforated panel type resonator embedded with a perforated panel is proposed. The perforated panel is installed in the neck, which is then extended into the resonator cavity so that it can ensure useful volume. The absorption performance of the perforated panel type of resonator is obtained by acoustic analysis and experiment. The analytical results are in good agreement with the experimental results. In the case of multiple perforated panel type resonators, as the number of perforated panels increase, the 1st resonance frequency is moved to a low frequency band and sound absorption bandwidth is extended on the whole. In order to obtain excellent absorption performance, the impedance matching between multi-panels should be considered. When the perforated panel in the resonator is combined with a porous material, the absorption performance is highly enhanced in the anti-resonance and high frequency range. In case of the resonator inserted with perforated panels of 2, the 2nd resonance frequency is shifted to a low frequency band in proportion to the distance between perforated panels.

A Review of Heat and Mass Transfer Analysis for Absorption Process

  • Kim, Jin-Kyeong;Kang, Yong-Tae
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권4호
    • /
    • pp.131-137
    • /
    • 2006
  • The absorber in which heat and mass transfer phenomena occur simultaneously is one of the most critical components in the absorption system. It has the most significant influence on the performance and the size of the absorption system. During the absorption process, heat and mass transfer resistances exist in both liquid and vapor regions, so that the heat transfer mode should be carefully selected to reduce them. The objective of this paper is to review the previous papers analysing mathematical models of simultaneous heat and mass transfer phenomena during the absorption process. The most conventional working fluids ($H_2O$LiBr and $NH_3/H_2O$) are considered and the most common absorption modes (falling film and bubble mode) are dealt with in this review.

공냉형 암모니아/물 GAX 흡수식 냉동 사이클의 수치 해석 (A Numerical Simulation of Air-Cooled Ammonia/Water GAX Absorption Cooling Cycle)

  • 정시영
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.488-500
    • /
    • 1995
  • An air-cooled ammonia/water GAX(Generator-Absorber heat eXchange) absorption cooling cycle is proposed and its performance is numerically evaluated. It is shown that the performance of the system is greatly dependent on the quality of the refrigerant leaving the evaporator. For any refrigerant concentration in the investigated range(99.1~99.9% ammonia), the cycle COP(coefficient of performance) reaches the highest value, when some amount(about 7%) of refrigerant evaporates in the refrigerant heat exchanger. Among temperature differences in various heat exchangers, the temperature difference between GAX-absorber and the GAX-generator shows the greatest effect on the system performance, whereas pressure losses cause no significant decrease in COP. The system COP increases almost linearly with increasing evaporator temperature, decreasing absorber temperature or decreasing condenser temperature. If both absorber and condenser temperature increase simultaneously, the decrease in the COP becomes larger.

  • PDF

흡수식 냉온수기의 부분부하에 따른 냉각수 변유량시 성능특성에 관한 연구 (A Study on the Performance Characteristics of an Absorption Chiller for Variable Cooling Water Flow Rate at Partial Load Conditions)

  • 박찬우;조현철;강용태
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.26-33
    • /
    • 2004
  • In general, an absorption chiller or heat pump is operated under the constant cooling water flow rate condition even though the system works with a partial load. The objective of this paper is to study the effect of the cooling water flow rates and the temperature of cooling water on the system performance to find the energy saving methode for the partial load operation of the double effect $H_2O$/LiBr absorption chiller. It is found that the performance of the system is sensitive to the temperature of cooling water than the cooling water flow rate, so the decrease of the performance due to reducing the cooling water flow rate can be overcome with the reduction of the cooling water temperature by 1$^{\circ}C$. The flow rate of the cooling water flow rate ranges from 50% to 100% of the flow rate at normal conditions with a partial load. It is also found that the operation cost of the cooling water pump and the cooling tower can be reduced by 23%.

이성분 나노유체($NH_3/H_2O$+나노입자)의 흡수성능 촉진실험 (Experimental of Absorption Performance Enhancement for Binary Nanofluids($NH_3/H_2O$ + Nano Particles))

  • 이진기;정청우;구준모;강용태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.124-129
    • /
    • 2008
  • The objectives of this paper are to examine the effect of nano-particles on the pool type absorption heat transfer enhancement and to find the optimal conditions to design a highly effective compact absorber for $NH_3/H_2O$ absorption system. The effect of $Al_2O_3$ and CNT particles on the absorption performance is studied experimentally. The experimental ranges of the key parameters are 20% of $NH_3$ concentration, $0{\sim}0.08%$ (volume fraction) of CNT particles, and $0{\sim}0.06%$ (volume fraction) of $Al_2O_3$ nano-particles. For the $NH_3/H_2O$ nanofluids, the heat transfer rate and absorption rate with 0.02 vol% $Al_2O_3$ nano-particles were found to be 28.9% and 17.8% higher than those without nano-particles, respectively. It is recommended that the concentration of 0.02 vol% of $Al_2O_3$ nano-particles be the best candidate for $NH_3/H_2O$ absorption performance enhancement.

  • PDF

기술혁신형 중소기업의 조직요인이 경영성과에 미치는 영향: 흡수역량의 매개효과를 중심으로 (Influence of Organizational Factors on Business Performance in INNOBIZ SMEs: Focusing on the Mediating Effects of Absorption Capacity)

  • 성기욱;엄기용
    • 한국산업정보학회논문지
    • /
    • 제27권3호
    • /
    • pp.59-88
    • /
    • 2022
  • 개방형 혁신이 확산되면서 외부의 새로운 지식을 탐색하고 이를 조직의 기존 지식과 결합하여 활용하는 흡수역량이 기업의 경영성과를 높이는 데 중요한 역할을 하는 것으로 평가되고 있다. 본 연구는 기술혁신형 중소기업에서 흡수역량을 매개로 조직 요인인 임파워링 리더십, 조직학습 문화 그리고 부서간 협력이 경영성과에 미치는 영향을 실증적으로 분석하였다. 이를 위해 이노비즈 협회 회원사 15,227개 기업을 대상으로 설문조사를 수행하였으며, 수집된 326건의 설문응답 내용을 구조방정식 모형을 이용하여 분석하였다. 설문 분석결과에 의하면 조직 요인인 임파워링 리더십, 조직학습 문화 및 부서간 협력은 경영성과에 직접적인 영향은 주지 않았지만, 흡수역량을 매개로 경영성과에 유의한 영향을 주는 것으로 나타났다. 이러한 결과는 임파워링 리더십, 조직학습 문화 및 부서간 협력이 흡수역량의 매개효과를 통해 경영성과에 간접적인 영향을 주고 있음을 의미하는 동시에, 기업의 조직 요인들이 흡수역량의 선행요인 중의 하나로 작용함을 입증해준다.

다양한 환경에 적용 가능한 충격흡수시설의 시뮬레이션 분석 및 실물충돌시험 결과 분석 (Analysis between Computer Simulation and Real-car Crash Test of Energy Absorption Facilities for Various Road Environments)

  • 노민형;박재홍;서창원;성정곤;윤덕근
    • 대한토목학회논문집
    • /
    • 제42권3호
    • /
    • pp.399-407
    • /
    • 2022
  • 도로안전시설 설치 및 관리 지침 차량방호 안전시설 편에서 충격흡수시설은 실물충돌시험을 통해 성능 기준을 만족하는 제품만을 현장에 설치하도록 하고 있다. 그러나 기존의 설치된 충격흡수시설의 경우 설치 환경에 따라 방호해야할 구조물과의 폭 차이로 인하여 방호성능을 발휘하지 못하는 문제점이 있다. 이에 본 연구에서는 다양한 환경에 적용하기 위하여 높이 150 mm의 W형 가드레일을 200 mm 간격으로 4단 배치하는 충격흡수시설을 LS-DYNA 컴퓨터 시뮬레이션을 이용하여 개발하고 실물충돌시험을 통하여 성능 기준을 검증하였다. 시뮬레이션을 통해 개발한 충격흡수시설이 CC2등급의 성능 기준을 만족한다는 것을 실물충돌시험으로 확인하였고 시뮬레이션 결과와 실물충돌시험 결과를 비교 분석하여 충돌 시뮬레이션의 결과가 유의미하다는 것을 확인하였다.