• Title/Summary/Keyword: Absorbed dose

Search Result 557, Processing Time 0.033 seconds

A absorbed and effective dose from the full-mouth periapical radiography using portable dental x-ray machine and panoramic radiography (ORIGINAL ARTICLE - 이동형 구내방사선촬영기로 촬영한 치근단 방사선촬영과 파노라마방사선촬영의 흡수선량과 유효선량 평가)

  • Han, Won-Jeong
    • The Journal of the Korean dental association
    • /
    • v.50 no.7
    • /
    • pp.420-430
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for full-mouth periapical radiography using the portable dental x-ray machine and panoramic radiography Material and Method: Thermoluminescent chips were placed at 25sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable dental x-ray machine and panoramic unit. During full-mouth periapical radiography the exposure setting was 60 kVp, 2 mA and 0.15 ~ 0.25 seconds, while during panoramic radiography the selected exposure setting was 72 kVp, 8 mA and 18 seconds. Absorbed dose measurements were obtained and equivalent doses to individual organs were summed using ICRP 103 to calculate of effective dose. Result: In the full-mouth periapical radiography, the highest absorbed dose was recorded at the mandible body follow with submandibular glands and cheek. Using panoramic unit, the highest absorbed dose was parotid glands and the following was back of neck and submandibular glands. The effective dose in full-mouth periapical radiography using portable dental x-ray machine was 46 ${\mu}Sv$. In panoramic radiography, the effective dose was 38 ${\mu}pSv$. Conclusion: It was recommended to panoramic radiography for general check in the head and neck area because that the effect dose in the panoramic radiography was lower than the dose in the full-mouth periapical radiography using portable dental x-ray machine.

Evaluation of effective dose in panorama, cone beam CT and the usefulness of x-ray protective (치과방사선검사에서 방사선방어용구 사용 전, 후의 유효선량에 대한 평가)

  • Kim, Jae In;Choi, Won Keun;Lee, So La;Lee, Jung Hwa;Lee, Kwan Sub
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.15-22
    • /
    • 2012
  • The purpose of this study was to measure the absorbed dose and calculate the effective dose for cone beam computed tomography (CBCT) and panorama units and to estimate usefulness of x-ray protective. Rando phantom and glass dosimeters were used for dosimetry. The absorbed doses were measured at 15 organs and 14 remainder from correspond to ICRP 2007 recommendations. The absorbed dose was highest in salivary glands as measured CBCT 2.420mGy, panorama 0.307mGy. Absorbed dose in another organs were high in order of thyroid, brain, skin, esophagus. The effective dose was CBCT 0.100mSv, panorama 0.011mSv and effective dose of panorama was higher than that of CBCT by 10 times. In case of wearing x-ray protective, reducing effective dose of CBCT by 0.066mSv (66%) and panorama by 0.008mSv (72%). Effective dose were reduced by radiological shielding but it needs further optimization studies, where dosimetric data are analyzed in combination with image quality with keep the patients' exposure as low as possible.

  • PDF

Comparison of Air Kerma and Absorbed Dose to Water Based Protocols for High Energy Photon Beams: Theoretical and Experimental Study

  • Shin, Dong-Oh;Kim, Seong-Hoon;Seo, Won-Seop;Park, Sung-Yong;Park, Jin-Ho;Kang, Jin-Oh;Hong, Seong-Eon;Ahn, Hee-Kyung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.241-243
    • /
    • 2002
  • New types of protocols have been recently in development, all based on an absorbed dose-to-water with the aim of improving the accuracy of measurements of absorbed dose to water. IAEA TRS-277, the air-kerma standard-based present protocol, and IAEA TRS-398 and AAPM TG-51, the absorbed dose-to-water standard-based new one, were studied and compared theoretically and experimentally for photon beams of 6, 10, and 15 MV. NE 2571 and 3 Farmer types of ionization chambers in widely commercial use were used to determine an absorbed dose to water at the reference depth in water. Two different kinds of calibration factors were given respectively for every chamber calibrated in $\^$60/CO gamma ray beams from a Korean Secondary Standard Dosimetry Laboratory (KFDA). This work shows that there is around 1 % of difference of absorbed doses measured between two different types of calibration systems owing to different physical parameters and reference conditions used. We hope this work to help form the basis on development of new type of protocol in Korea.

  • PDF

Evaluation of Photoneutron Dose in Radiotherapy Room Using MCNPX (MCNPX를 이용한 방사선 치료실의 광중성자 선량 평가)

  • Park, Eun-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.6
    • /
    • pp.283-289
    • /
    • 2015
  • Recently, high energy photon radiotherapy is a growing trend for increasing therapy results. Commonly, if you use high energy photons above 6~8 MeV nominal accelerator voltage, It lead the photo-nuclear reaction and the generation of photo-neutron are accompanied and these problematic factors are issued in the view of radiation protection. Therefore, in this study analyzed for dose distribution of photo-neutron in radiotherapy room based on MCNPX. As a result, absorbed dose is increased sharply from 10 MV to 12 MV. It was founded that the rapid increasement of photoneutron fluence was related to the absorbed dose at above 10 MV. Also, in case of the recommendation of ICRP 103, the outcome of an exchanged equivalent dose which based on calculated an absorbed dose, showed lower equivalent dose than ICRP 60 by reflecting the contribution of secondary photon for absorbed dose of human body in the low energy band.

Evaluation Absorbed Dose During the Breast Cancer Brachytherapy in Canine Phantom (반려견 팬텀에서 유방암 근접방사선치료 시 흡수선량 평가)

  • Kim, Jung-Hoon;Lee, Deuk-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.523-528
    • /
    • 2020
  • The application of breast cancer, which has the highest incidence in females among cancer that is the number one cause of death for dogs, was to be evaluated the absorbed dose during brachytherapy using simulation. MCNPX program was used for simulation, and a small size canine phantom was produced to measure absorbed dose. The results of the absorbed dose was the highest at 192Ir to 1.02E-12 Gy/# for tumors, and the same tendency was shown for internal and external absorbed dose. Therefore, the selection of appropriate sources for dog breast cancer should be considered in brachytherapy, taking into account dog breeds and exposures.

Estimation of Absorbed Dose for Anterior and Posterior Organs with Body Mass Index in Standing Whole Spine Examination (Standing Whole Spine 검사 시 체질량지수 (BMI)에 따른 전방 및 후방장기의 흡수선량 평가)

  • Shim, Ji Na;Lee, Yong-Gu;Lee, Youngjin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.147-151
    • /
    • 2016
  • Automatic exposure control (AEC) is frequently used in many hospitals for Standing Whole Spine examination which is able to control radiation dose with respect to the body type such as body mass index (BMI) and we can measure dose area product (DAP) based on respective patient information. However, few studies have been conducted organ absorbed dose evaluation based on location of patient organ. The purpose of this study was to evaluate the relationships between BMI and organ absorbed dose along with location of patient organ. For that purpose, we calculated absorbed dose with selected 5 patient organ (thyroid, breast, heart, kidney, and pancreas) using a PCXMC simulation tool with measured DAP. According to the results, measured DAP increases with BMI and organ absorbed dose decreases with BMI in anterior organs such as thyroid, breast, and heart. On the other hand, there is no correlation between organ absorbed dose and BMI in posterior organs such as kidney and pancreas. In conclusion, our results demonstrated that the radiation effects are different with respect to BMI and location of patient organ in Standing Whole Spine examination.

Bias-corrected Hp(10)-to-Organ-Absorbed Dose Conversion Coefficients for the Epidemiological Study of Korean Radiation Workers

  • Jeong, Areum;Kwon, Tae-Eun;Lee, Wonho;Park, Sunhoo
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.3
    • /
    • pp.158-166
    • /
    • 2022
  • Background: The effects of radiation on the health of radiation workers who are constantly susceptible to occupational exposure must be assessed based on an accurate and reliable reconstruction of organ-absorbed doses that can be calculated using personal dosimeter readings measured as Hp(10) and dose conversion coefficients. However, the data used in the dose reconstruction contain significant biases arising from the lack of reality and could result in an inaccurate measure of organ-absorbed doses. Therefore, this study quantified the biases involved in organ dose reconstruction and calculated the bias-corrected Hp(10)-to-organ-absorbed dose coefficients for the use in epidemiological studies of Korean radiation workers. Materials and Methods: Two major biases were considered: (a) the bias in Hp(10) arising from the difference between the dosimeter calibration geometry and the actual exposure geometry, and (b) the bias in air kerma-to-Hp(10) conversion coefficients resulting from geometric differences between the human body and slab phantom. The biases were quantified by implementing personal dosimeters on the slab and human phantoms coupled with a Monte Carlo method and considered to calculate the bias-corrected Hp(10)-to-organ-absorbed dose conversion coefficients. Results and Discussion: The bias in Hp(10) was significant for large incident angles and low energies (e.g., 0.32 for right lateral at 218 keV), whereas the bias in dose coefficients was significant for the posteroanterior (PA) geometry only (e.g., 0.79 at 218 keV). The bias-corrected Hp(10)-to-organ-absorbed dose conversion coefficients derived in this study were up to 3.09- fold greater than those from the International Commission on Radiological Protection publications without considering the biases. Conclusion: The obtained results will aid future studies in assessing the health effects of occupational exposure of Korean radiation workers. The bias-corrected dose coefficients of this study can be used to calculate organ doses for Korean radiation workers based on personal dose records.

COMPARISON OF ABSORBED DOSES RESULTING FROM VARIOUS INTRAORAL PERIAPICAL RADIOGRAPHY (전악 치근단 방사선사진 촬영시 촬영조건에 따른 흡수선량 변화에 대한 연구)

  • Kang Mi-Ae;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.297-308
    • /
    • 1995
  • This study was designed to measure the absorbed dose to organs of special interest from full mouth with intraoral film(l4 films) and to compare the five periapical techniques. Thermoluminescent crystals(TLD-100 chip) were located in brain, orbit, bone marrow of mandibular ramus, bone marrow of mandibular body, bone marrow of 4th cervical spine, parotid gland, submandibular gland and thyroid gland. X -ray machine was operated at 70kVp and round collimating film holding device(XCP) and rectangular collimating film holding device(Precision Instrument) were used. The distance from the X-ray focus to the open end of the collimator was 8 inch, 12 inch and 16 inch. The results were as follows : 1. The absorbed dose was the highest in bone marrow of mandibular body(5.656mGy) and the lowest in brain (0.050mGy). 2. Generally, the lowest absorbed dose was measured from 16 inch cylinder, rectangular collimating film holding device with paralleling technique. But, in bone marrow of mandibular body and the floor of mouth, the highest absorbed dose was measured from 12 inch cylinder, rectangular collimating film holding device with paralleling techniques. 3. Comparing of five intraoral radiographic techniques, it was appeared statistically significant reduction of the absorbed doses measured with rectangular collimating film holding device compared to XCP film holding device (P<0.05). 4. No statistically significant reduction in the absorbed dose was found as cylinder length was changed(P>0.05).

  • PDF

A formalism for the absorbed dose evaluation of the glass dosimeter

  • Ka-Young Park;Hyun-Chul Kim;Byoung-Chul Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2283-2287
    • /
    • 2023
  • We propose in the present work how the reference glass dosimeters can be introduced, which reflects the user irradiation condition. The reference glass dosimeters are used for correcting the reader fluctuation by reading it with sample glass dosimeters at the same time. Since they can be used without annealing after irradiation for long periods, one should consider both the fading effect and the natural background dose accumulation quantitatively. We construct an empirical but practical formalism of evaluating the absorbed dose on the glass dosimeter with the fading effect and the natural background dose accumulation considered.