• 제목/요약/키워드: Absorbed dose

검색결과 562건 처리시간 0.024초

유방암 근접치료 시 나노입자의 밀도에 따른 흡수선량 평가 (Evaluation of Absorbed Dose According to Nanoparticle Density During the Breast Cancer Brachytherapy)

  • 이득희;남지희;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권2호
    • /
    • pp.131-135
    • /
    • 2019
  • The purpose of this study was to evaluate the efficacy of brachytherapy of breast cancer by dose assessment which a steady increased in Korea women. The dose assessment was performed using the MCNPX program, a MonteCarlo simulation technique. The sources used for brachytherapy was 192Ir. And nanoparticle which used for dose enhancement was gold. The density of nanoparticle was 7, 18 and 30 mg. Evaluation of absorbed dose according to distance is measured at a distance of 30, 50, 100 and 200 cm from the patient. As a result, The breast absorbed dose results increased in proportion to the density of nanoparticle. And the surrounding organs were not significantly different according to the density. But, in some organs, the absorbed dose decreased as the density of nanoparticles increased. Absorbed dose according to the distance was in inverse proportion to distance.

직.간접디지털 파노라마 방사선촬영시 흡수선량과 유효선량 (Absorbed and effective dose in direct and indirect digital panoramic radiography)

  • 이근선;김진수;김재덕
    • Imaging Science in Dentistry
    • /
    • 제40권1호
    • /
    • pp.9-14
    • /
    • 2010
  • Purpose : We evaluated the absorbed doses to the organs and calculated the effective doses when using the digital panoramic radiography. Materials and Methods : The absorbed dose averages in major organs of oral and maxillofacial region were measured using the Dental head phantom (CIRS Co., USA), $^nLi_2B_4O_7$ TLD chip and UD-716AGL dosimeter (Matsushita Electric Industrial Co., JPN) when performing indirect and direct digital panoramic radiography. Effective doses were calculated from correspond to ICRP 2007 recommendations for two panoramic radiography. Results : The absorbed dose average on indirect and direct digital panoramic radiography was highest in parotid glands as measured 1259.6 mGy and 680.7 mGy respectively. Absorbed dose average in another organs were high in order of esophagus, submandibular gland, tongue and thyroid gland on both types of digital panoramic radiography. The absorbed dose average was higher on indirect type than direct one (p<0.05). The effective dose was higher on indirect type than direct one as measured 13.28 mSv and 8.70 mSv respectively. Conclusion : The absorbed doses in salivary gland and oral mucosa were high. However, thyroid gland also demands the attention on radiography due to high tissue weighting factor in spite of the low absorbed dose.

Absorbed Dose from Large Balloon Filled with Liquid Ho-166

  • Joh, Chul-Woo;Park, Chan H.;Lee, Myoung-Hoon;Yoon, Seok-Nam;Kim, Mi-Hwa;Jang, Ji-Sun;Park, Kyung-Bae
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.328-330
    • /
    • 2002
  • Large balloon angio catheter is used for Percutaneous Transluminal Angioplsty(TPA) of the iliac, femoral and renal arteries as well as after Transjugular Intrahepatic portosystemic shunt(TIPS). The use of angioplasty balloon filled with liquid form of radioisotope reduces the rate of restenosis after PTA. The purpose of this study was to evaluate the absorbed dose to the target vessels from various sized large balloon filled with liquid form of Ho-166-DTPA. Four balloons of balloon dilatation catheters evaluated were 5, 6, 8 and 10 mm in diameter. GafChromic film was used for the estimation of the absorbed dose near the surface of the balloon catheters. Absorbed dose rates are plotted in units of Gy/min/GBq/ml as a function of radial distance in mm from the surface of balloon. The absorbed dose rate was 1.1, 1.6, 2.2 and 2.3 Gy/min/GBq/ml at a balloon surface, 0.3, 0.4, 0.5 and 0.6 Gy/min/GBq/ml at 1 mm depth for various balloon diameter 5, 6, 8 and 10 mm in diameter respectively. The study was conducted to estimate the absorbed doses to the vessels from various sized large balloons filled with liquid form of Ho-166-DTPA for clinical trial of radiation therapy after the PTA. The absorbed dose distribution of Ho-166 appeared to be nearly ideal for vascular irradiation since beta range is very short avoiding unnecessary radiation to surrounding normal tissues.

  • PDF

The role of natural rock filler in optimizing the radiation protection capacity of the intermediate-level radioactive waste containers

  • Tashlykov, O.L.;Alqahtani, M.S.;Mahmoud, K.A.
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3849-3854
    • /
    • 2022
  • The present work aims to optimize the radiation protection efficiency for ion-selective containers used in the liquid treatment for the nuclear power plant (NPP) cooling cycle. Some naturally occurring rocks were examined as filler materials to reduce absorbed dose and equivalent dos received from the radioactive waste container. Thus, the absorbed dose and equivalent dose were simulated at a distance of 1 m from the surface of the radioactive waste container using the Monte Carlo simulation. Both absorbed dose and equivalent dose rate are reduced by raising the filler thickness. The total absorbed dose is reduced from 7.66E-20 to 1.03E-20 Gy, and the equivalent dose is rate reduced from 183.81 to 24.63 µSv/h, raising the filler thickness between 0 and 17 cm, respectively. Also, the filler type significantly affects the equivalent dose rate, where the redorded equivalent dose rates are 24.63, 24.08, 27.63, 33.80, and 36.08 µSv/h for natural rocks basalt-1, basalt-2, basalt-sill, limestone, and rhyolite, respectively. The mentioned results show that the natural rocks, especially a thicker thickness (i.e., 17 cm thickness) of natural rocks basalt-1 and basalt-2, significantly reduce the gamma emissions from the radioactive wastes inside the modified container. Moreover, using an outer cementation concrete wall of 15 cm causes an additional decrease in the equivalent dose rate received from the container where the equivalent dose rate dropped to 6.63 µSv/h.

177Lu-EDTMP radiation absorbed dose evaluation in man based on biodistribution data in Wistar rats

  • Reza Bagheri
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.254-260
    • /
    • 2023
  • Skeletal metastases are common in patients suffering from various primary cancers. Radiopharmaceuticals are an effective option for bone pain palliation. In this work, the radiation absorbed dose of 177Lu-EDTMP radiopharmaceutical was estimated for adult man based on biodistribution data in Wistar rats. The MIRD dose calculation method and the Sparks and Aydogan methodology were applied. The results shows that about 46% of injected activity is cumulated on the surface of the trabecular and cortical bones. Radiation absorbed doses of red bone marrow and osteogenic cells were estimated to about 1.1 and 6.2 mGy/MBq, respectively. The maximum administrated activity was obtained 27 MBq/kg of body weight with an effective dose of 0.23 mSv/MBq. The results were compared with other available data from literature. This study indicated that 177Lu-EDTMP provides therapeutic efficacy for achieving bone pain palliation with low undesired dose to other normal organs.

치과방사선 검사에서 두부(brain)의 흡수선량 평가 (Evaluation the absorbed dose in brain of dental radiography)

  • 전운선;한동균
    • 한국방사선학회논문지
    • /
    • 제5권6호
    • /
    • pp.343-349
    • /
    • 2011
  • 치과 방사선검사에 있어 두부 내의 흡수선량에 관한 평가를 하고자 인체모형팬텀 내부의 뇌하수체와 안구, 상악동, 악하선, 갑상선, 식도에 유리형광소자를 삽입하고 X-선을 조사하였다. 사용된 장치로는 Kodak 2200, Kodak 8000C dental radiographic systems과 computed tomography(Lightspeed VCT)이고 촬영조건은 임상에서 사용하는 인자와 동일하게 설정하였다. 이때 구내 X-선 검사의 경우 흡수선량은 0.02~2.47cGy로 가장 높게 측정된 곳은 상악 대구치 촬영 시 2.47cGy인 갑상선이었고 가장 낮은 곳은 하악 전치부 촬영에서 0.02cGy인 악하선이었다. 그리고 구외 X-선 검사의 경우 흡수선량은 세파로에서 0.36~3.44cGy, 파노라마에서 0.14~12.82cGy, 전산화단층촬영에서 8.17~253.63cGy 가장 높게 측정된 곳은 상악 CT 촬영 시 253.63cGy인 악하선이었고 가장 낮은 곳은 파노라마 촬영에서 0.14cGy인 안구이었다. 구외 X-선 검사가 구내 X-선 검사 보다 많은 흡수선량이 측정되었다. 특히 CT를 이용한 검사에서는 구내 촬영보다 100배 이상 높게 측정되었다. 따라서 구외 X-선 검사에 있어서 가이드라인을 제시하여야 하며 방사선에 의한 흡수선량을 줄이기 위한 노력이 요구된다.

영상유도 방사선 치료(IGRT)에 따른 정상 조직의 추가 피폭에 대한 연구 (A Study on the Additional Absorbed Dose of Normal Tissues by Image Guided Radiation Therapy(IGRT))

  • 김가중;류준민;최준구;홍동희
    • 한국콘텐츠학회논문지
    • /
    • 제16권1호
    • /
    • pp.75-81
    • /
    • 2016
  • 최근 방사선 치료 분야에서는 다양한 영상유도 방사선 치료(IGRT) 장치들을 이용한 환자 셋업으로 고도의 정밀성이 보장된 치료가 가능해 졌다. 그러나 환자의 정상 조직에 받는 추가 선량 또한 더불어 증가되고 있다. 이에 본 연구에서는 영상유도 방사선 치료 장치 중 OBI, CBCT, ExacTrac를 이용한 환자 셋업에 주변 정상 조직에 받는 피폭선량을 측정하였다. 결과 팬텀 중심부의 선량이 CBCT의 경우 두부 12.57 mGy, 흉부 20.82 mGy, 복부 82.93 mGy, 골반부위 52.70 mGy로 측정되었으며 OBI는 0.76 ~ 8.58 mGy, ExacTrac의 경우 0.14 ~ 0.63 mGy로 CBCT의 피폭선량이 다른 장비에 비해 월등히 높게 나타나는 것을 알 수 있었다. 표면 선량의 경우에서도 CBCT가 다른 장비에 비해 높게 나타났으나 입사 피부표면 선량(Enterance skin dose)의 경우 OBI도 CBCT의 피폭선량과 거의 비슷한 흡수선량이 측정 되었다.

방사선치료 시 처방선량과 치료기법에 따른 흡수선량 평가 (Evaluated Absorbed Dose According to Prescribed Dose and Therapeutic Technique in Radiation Therapy)

  • 이득희;박은태;김정훈;임인철
    • 한국방사선학회논문지
    • /
    • 제10권6호
    • /
    • pp.469-476
    • /
    • 2016
  • 본 논문에서는 움직이는 타깃을 대상으로 처방선량과 치료기법에 따른 흡수선량을 유리선량계를 이용하여 평가하였다. 타깃의 움직임에 따라 조사야에서 벗어나는 정도에 따른 선량을 MCNPX를 이용하여 모의모사하였으며 그 결과 조사야에서 이격하는 거리에 비례하여 감소하는 것으로 나타났다. 처방선량에 따른 흡수선량의 결과는 3D CRT의 경우 저선량에서 IMRT보다 흡수선량이 높은 것으로 나타났으며, 대선량에서는 IMRT가 더 높은 비율을 보였다. 치료기법에 따른 결과는 3D CRT가 가장 우수한 것으로 나타났으며, IMRT의 sliding window방식이 가장 낮은 것으로 나타났다. 본 연구를 통하여 3D CRT가 움직이는 타깃에 가장 높은 선량을 조사할 수 있는 기법으로 평가되었다. 하지만 정상조직의 보호효과와 환자의 상태 등을 고려한 적절한 치료기법의 선택으로 치료효과를 높일 수 있는 노력이 필요할 것이다.

고 에너지 전자선에 대한 공기커마와 물 흡수선량에 기반한 프로토콜간의 비교 (Comparison of Air Kerma­based and Absorbed Dose to Water­based Protocols in the Dosimetry of High Energy Electron Beams)

  • 박창현;신동오;박성용
    • 한국의학물리학회지:의학물리
    • /
    • 제14권4호
    • /
    • pp.249-258
    • /
    • 2003
  • 흡수선량 측정의 정확성을 향상시키기 위하여 기존의 공기커마 혹은 조사선량 표준에서 물 흡수선량 표준으로 선량측정의 패러다임이 변화하고 있다. 본 연구는 기존의 프로토콜에서 물 흡수선량 기반의 프로토콜로의 전환을 모색하는 입장에서 현재 임상에서 널리 사용하고 있는 IAEA TRS­277과 물 흡수선량 표준에 토대를 두고 있는 IAEA TRS­398 및 AAPM TG­51 프로토콜에 대하여 동일한 기준깊이에서 물 흡수선량을 측정하여 상호 비교하였다. Varian 2100 C/D 선형가속기로부터의 세 종류의 전자선 에너지에 대해 PTW 30002 원통형 이온함과 Markus 및 Roos 평행평판형 이온함을 사용하여 측정하였고 $^{60}$Co에서의 공기커마 및 물 흡수선량 교정정수는 식품의약품안전청으로부터 받아 사용하였다. 공기커마 표준에 기반한 프로토콜과 물 흡수선량 표준에 기반한 프로토콜간에는 2% 이내의 차이를 보임으로써 사용자 기관에서는 자체적인 확인을 거쳐 공기커마 기반의 프로토콜에서 물 흡수전량 기반 프로토콜로의 전환을 적극 검토해 볼 필요가 있다. 물 흡수선량 기반의 프로토콜간에는 원통형 이온함의 경우 0.5% 이내에서 잘 일치하였고 평행평판형 이온함의 경우에도 고 에너지 전자선을 이용한 교차 교정을 하면 0.7% 이내에서 잘 일치하였다. 사용한 모든 프로토콜과 전자선 에너지에 대해 원통형 이온함과 평행평판형 이온함간에는 2% 이내의 차이를 보였으나 선량측정의 정확성을 향상시키기 위해 물 흡수선량 표준에 기반한 프로토콜의 권고에 따라서 하한에너지 이하의 전자선의 경우는 원통형 이온함 대신에 평행평판형 이온함을 사용함이 타당하다고 사료된다.

  • PDF

A SOLUTION TO THE PROBLEM WITH ABSORBED DOSE

  • Braby, Leslie A.
    • Nuclear Engineering and Technology
    • /
    • 제40권7호
    • /
    • pp.533-538
    • /
    • 2008
  • In some situations, for example at very low doses, in microbeam irradiation experiments, or around high energy heavy ion tracks, use of the absorbed dose to describe the energy transferred to the irradiated target can be misleading. Since absorbed dose is the expected value of energy per mass it takes into account all of the targets which do not have any energy deposition. In many situations that results in numerical values, in Joules per kg, which are much less than the energy deposited in targets that have been crossed by a charged particle track. This can lead to confusion about the biochemical processes that lead to the consequences of irradiation. There are a few alternative approaches to describing radiation that avoid this potential confusion. Examples of specific situations that can lead to confusion are given. It is concluded that using the particle radiance spectrum and the exposure time, instead of absorbed dose, to describe these irradiations minimizes the potential for confusion about the actual nature of the energy deposition.