• Title/Summary/Keyword: Absolute phase

Search Result 252, Processing Time 0.028 seconds

Infrared Thermal Video Stabilization Performance Comparison (열화상 영상 안정화 성능 비교)

  • Park, Chan-hyeok;Kwon, Hyuk-shin;Kang, Seok-hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.101-104
    • /
    • 2015
  • Motion vector is that comparing a frame between previous frame and current one about how much moved. Using this motion vector, if move the image object of current frame to former frame, it could be corrected to shake from hand and camera shaking. On this thesis, compared efficiency of block matching using SAD(Sum of Absolute Difference) equation as picking out the motion vector, matching using phase correlation, matching using feature point, block matching using bitplane.

  • PDF

Theoretical Prediction of the Thermodynamic Properties of Liquid-Crystalline p-Azoxyanisole (액정 p-Azoxyanisole의 열역학적 성질에 대한 이론적인 예측)

  • Youngkyu Do;Mu Shik Jhon;Taikyue Ree
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.2
    • /
    • pp.118-128
    • /
    • 1976
  • The significant structure theory of liquids and the Bragg-Williams approximation of phase transition theory have been applied to the calculation of the thermodynamic properties of p-azoxyanisole which exhibits a liquid crystal phase of the nematic type. The isotropic phase was treated as a normal liquid; and for the nematic phase, in addition to its liquidity, the effect due to the arrangement of molecular-dipoles was considered. The liquidity of the p-azoxyanisole was described by the significant structure theory of liquids, and the Bragg-Williams approximation was used to consider the effect due to the arrangement of molecular-dipoles. The molar volume, vapor pressure, heat capacity at constant pressure, thermal expansion coefficient, compressibility, entropy and enthalpy change at the nematic-isotropic phase transition point, absolute entropy, and absolute Helmholtz free energy were calculated over the temperature range of the nematic and isotropic phases. The calculated results of the thermodynamic properties were compared with the experimental data.

  • PDF

Real-Time Relative Navigation with Integer Ambiguity

  • Shim, Sun-Hwa;Park, Sang-Young;Choi, Kyu-Hong
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.34.3-34.3
    • /
    • 2008
  • Relative navigation system is presented using measurements from a single-channel global positioning system (GPS) simulator. The objective of this study is to provide real-time relative navigation results as well as absolute navigation results for two formation flying satellites separated about 1km in low earth orbit. To improve the performance, more accurate dynamic model and modified relative measurement model are developed. This modified method prevents non-linearity of the measurement model from degrading precision by applying linearization about the states from absolute navigation algorithm not about a priori states. Furthermore, absolute states are obtained using ion-free GRAPHIC pseudo-ranges and precise relative states are provided using double differential carrier-phase data based on Extended Kalman Filter. The software-based simulation is performed and achieved meter-level precision for absolute navigation and millimeter-level precision for relative navigation. The absolute and relative accuracies at steady state are about 0.77m and 4mm respectively (3D, r.m.s.). In addition, Integer ambiguity algorithm (LAMBDA method) improves simulation performances.

  • PDF

Phase Shift Analysis and Phase Identification for Distribution System with 3-Phase Unbalanced Constant Current Loads

  • Byun, Hee-Jung;Shon, Sugoog
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.729-736
    • /
    • 2013
  • Power grids are large complicated networks in use around. An absolute phase value for a particular unknown-phase line at a local site should be identified for the operation and management of a 3-phase distribution network. The phase shift for a specific point in the line, as compared with a phase reference point at a substation, must be within a range of ${\pm}60^{\circ}$ for correct identification. However, the phase shift at a particular point can fluctuate depending on the line constants, transformer wiring method, line length, and line amperage, etc. Conducted in this study is a theoretical formulation for the determination of phase at a specific point in the line, Simulink modeling, and analysis for a distribution network. In particular, through evaluating the effects of unbalanced current loads, the limitations of the present phase identification methods are described.

Bubble Formation in Liquid Helium under Negative Pressure by Quantum Tunneling near Absolute Zero Temperature (절대 0도 부근에서 양자터널링에 의한 헬리움(He)액체의 부압하에서의 기포형성)

  • Kwak, H.;Jung, J.;Hong, J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.354-359
    • /
    • 2001
  • As the temperature of liquid under negative pressure approaches the absolute zero, the nucleation process due to thermal fluctuations hardly occurs. Instead of this mechanism, quantum fluctuations may lead the formation of nucleus for new phase in metastable state. In this study, the thermal as well as quantum nucleation bubble in liquid helium under negative pressure was investigated theoretically. The energy barrier against nucleation was estimated by molecular interaction due to the Londom dispersion force. It is shown that the phase transition from liquid to vapor in is possible due to the quantum tunneling below 0.2 K for Helium-4 and 0.1 K for Helium-3, at negative pressures close to the ideal tensile strength at which every liquid molecules become bubbles simultaneously.

  • PDF

Current Range Extension of Current Transformers by Using Absolute Evaluation Technique and Two Different Current Transformers (전류변성기 절대 평가 기술과 전류변성기 두 대를 이용한 전류 범위 확장)

  • Kim, Yoon-Hyoung;Han, Sang-Gil;Jung, Jae-Kap;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.69-71
    • /
    • 2008
  • We have developed a current range extension method to obtain the ratio error and phase displacement of a current transformer (CT) by using absolute evaluation method and two different CTs. The method was applied to CTs under test with the current ratios of the range of 5,000 A / 1 A - 20,000 A / 1 A. The ratio error and phase displacement of the CT under test obtained in this study are consistent with those measured at the national institute in Germany using the same CT under test within an expanded uncertainty (k = 2) in the overall current ratios.

  • PDF

A Design and Construction of Speed Encoder for High Performance Driving of SRM (SRM 고정도 구동을 위한 위치 및 속도엔코더의 설계 및 제작)

  • Kang, Yu-Jung;Oh, Seok-Kyu;Park, Sung-Jun;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1191-1193
    • /
    • 2001
  • In switched reluctance motor(SRM) drive, it is necessary to synchronize the stator phase excitation with the rotor position. Therefore, the rotor position information is essential. Usually, optical encoders or resolvers are used to provide the rotor position information. These sensors are expensive and are not suitable for high speed operation. This paper proposes a new encoder for high performance excitation control of SRM. The proposed encoder has complex structures of incremental and absolute encoder. An each phase inductance profile can be synchronized with 4-bit absolute position signal and incremental pulses are used for speed detection. Low cost and simple structure are possible.

  • PDF

Absolute Evaluation of Inductor Using Current Transformer Comparator (전류변성기 비교기를 이용한 인덕터의 절대 평가)

  • Kim, Yoon-Hyoung;Jung, Jae-Kap;Han, Sang-Gil;Kim, Han-Jun;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.279-284
    • /
    • 2008
  • We have developed two absolute evaluation technology of inductor using current transformer (CT) comparator. One is the method that the reactance of inductor is obtained by analysing the equivalent circuit of CT with inductor connected to series at secondary terminal of CT. The other is the method that the reactance of inductor is obtained by comparing phase displacement of current flowing on inductor by using CT comparator. These technologies have the advantage to apply up to rated current and voltage of inductor. The method was applied to inductors under test in the range of $100 {\mu}H{\sim}1\;H$. The inductance of the inductor under test obtained in this study are consistent with those measured by LCR meter using the same inductor within an expanded uncertainty (k = 2) in the overall range of inductance.

Driving Characteristics of Encoder for High Performance Excitation Control of SRM (SRM의 고정도 여자 제어를 위한 엔코더의 운전특성)

  • Kang Yu-Jung;Ahn Jin-Woo;Park Sung-Jun;Kim Cheul-U
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.1-4
    • /
    • 2001
  • SRM(Switched Reluctance Motor) uses reluctance torque by pulse excitation control. SRM drives are much studied in electrical vehicles and industrial application due to the simple, robust mechanical structure and high speed characteristics. For the high performance control of SRM, it is necessary to synchronize the stator phase excitation with the rotor position. This paper proposes a new encoder for high performance excitation control of SRM. The proposed encoder has complex structures of incremental and absolute encoder. An each phase inductance profile can be synchronized with 4-bit absolute position signal and incremental pulses are used for speed detection. Low cost and simple manufacturing of SRM encoder is possible.

  • PDF

Absolute Evaluation of Capacitor and Inductor Using Voltage Transformer Comparator (전압변성기 비교기를 이용한 커패시터와 인덕터의 절대 평가)

  • Han, Sang-Gil;Kim, Yoon-Hyoung;Jung, Jae-Kap;Kim, Han-Jun;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.285-290
    • /
    • 2008
  • We have developed the absolute evaluation technique of capacitor and inductor by measuring the phase displacement as a function of resistance of employed resistors in voltage transformer(VT) comparator. The methods were applied to the capacitor with the range of 100 nF - $5{\mu}F$ and the inductor with the range of $100{\mu}H{\sim}1\;H$. The capacitance values of capacitor obtained using our method are consistent within the expanded uncertainty those obtained using capacitor bridge. The inductance values of inductor obtained using our method are also consistent within the expanded uncertainty those obtained using LCR meter.