• Title/Summary/Keyword: Absolute phase

Search Result 253, Processing Time 0.026 seconds

High Precision Measurement for String Resonator used in FBG Strain Sensors (광섬유 브래그 격자 변형률 센서용 현공진기의 고정밀 측정)

  • 이영균;송인천;정성호;이병하;이선규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.135-139
    • /
    • 2001
  • This paper describes a string resonator that is used for the interrogation system of a Fiber Bragg Grating(FBG) strain sensor. The strain on the fiber piece is calculated from the measured frequency based on that the natural frequency of a string is a function of the applied absolute strain. Existing research considered a fiber as a string, but a fiber is not a string in the strict sense due to its bending stiffness, thus the fiber should be modeled as a beam accompanied with an axial force. In the vibration modeling, the relationship between the strain and the natural frequency is derived, and then the resonance condition is described in terms of both the phase and the mode shape for sustaining resonant motion. Several experiments verify the effectiveness of the proposed model of the fiber. The performance of the string resonator is analyzed by measuring the frequency change according to the applied strains in the dynamic range of 1100$\mu\varepsilon$ referred to the displacement from capacitance sensor. From the experimental results, the implemented string resonator provides the accuracy of $\pm$3$\mu\varepsilon$, the quasi-static resolution of ~0.1$\mu\varepsilon$(rms) which amount to be $\pm$0.17$\mu\textrm{m}$ and ~6nm respectively, in case of fiber length of 56mm. For a dynamic strain, it can provide the accuracy of ~3$\mu\varepsilon$ until the frequency comes to 8Hz. As a consequence, the string resonator proposed for FBG sensor provides the high accuracy and the high resolution in strain measurement, and also it is expecting to be used, for the application, to not only strain but also displacement measuring device.

  • PDF

Model for assessing the contamination of agricultural plants by accidentally released tritium (삼중수소 사고유출로 인한 농작물 오염 평가 모델)

  • Keum, Dong-Kwon;Lee, Han-Soo;Kang, Hee-Suk;Choi, Young-Ho;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.1
    • /
    • pp.45-54
    • /
    • 2005
  • A dynamic compartment model was developed to appraise the level of the contamination of agricultural plants by accidentally released tritium from nuclear facility. The model consists of a set of inter-connected compartments representing atmosphere, soil and plant. In the model three categories of plant are considered: leafy vegetables, grain plants and tuber plants, of which each is modeled separately to account for the different transport pathways of tritium. The predictive accuracy of the model was tested through the analysis of the tritium exposure experiments for rice-plants. The predicted TFWT(tissue free water tritium) concentration of the rice ear at harvest was greatly affected by the absolute humidity of air, the ratio of root uptake, and the rate of rainfall, while its OBT(organically bound tritium) concentration the stowing period of the ear, the absolute humidity of air and the content of hydrogen in the organic phase. There was a good agreement between the model prediction and the experimental results lot the OBT concentration of the ear.

Multiple-Point-Diffraction Interferometer : Error Analysis and Calibration (거친 표면 형상측정을 위한 점광원 절대간섭계의 오차해석과 시스템 변수의 보)

  • Kim, Byoung-Chang;Kim, Seung-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.361-365
    • /
    • 2005
  • An absolute interferometer system with multiple point-sources is devised for tile 3-D measurement of rough surface profiles. The positions of the point sources are determined to be the system parameters that influence the measurement accuracy, so they are calibrated precisely prior to performing actual measurements. For the calibration, a CCD camera composed of a two-dimensional array of photo-detectors was used. Performing optimization of the cost function constructed with phase values measured at each pixel on the CCD camera, the position coordinates of each point source is precisely determined. Measurement results after calibration performed for the warpage inspection of chip scale packages (CSPs) demonstrate that the maximum discrepancy is 9.8 mm with a standard deviation o( 1.5 mm in comparison with the test results obtained by using a Form Taly Surf instrument.

Three Phase Bone Scintigraphy in Active and Inactive Osteomyelitis (활동성 및 비활동성골수염에서의 삼상골신티그라피)

  • Yang, Woo-Jin;Chung, Soo-Kyo;Ha, Hyun-Kwon;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.22 no.2
    • /
    • pp.209-213
    • /
    • 1988
  • To Appreciate the value of bone scintigraphy in determination of the bony infection, we performed three phase bone scintigraphy in 34 cases of osteomyelitis of extremities prospectively. They were clinically inactive in 11 and active in 23 cases. We confirmed the active osteomyelitis by operation or aspiration within one week after scintigraphy. Perfusion, blood pool and delayed images were analyzed respectively and compared with the plain roentgenograms. All 23 active lesions showed diffusely increased perfusion in affected limbs. The areas of the increased activities on blood pool images were larger than or similar to those on delayed images in 17 cases (73.9%) with active osteomyelitis and smaller in 6 cases (26.1%). 5 of the latter 6 cases showed definite soft tissue activities on blood pool images. In inactive cases bone scintigrams were completely normal in 4 cases. Two of those were normal on plain films and remaining two showed mild focal bony sclerosis. Among 7 inactive lesions, perfusion was normal in 2 cases, diffusely increased in 4 cases and diffusely decreased in 1 case. 6 of these 7 cases showed increased activities both on blood pool and delayed images and the areas of increased activities on blood pool images didn't exceed those on delayed images. Bony sclerosis was noted on plain films in those 7 inactive lesions and the extent of the sclerosis correlated well to delayed images. Large blood pool activity was characteristics of active osteomyelitis. Normal three phase bone scintigram may indicate the time to terminate the treatment, but increased activity on perfusion and blood pool scans is not absolute indication of active lesion if the extent of the lesion on the blood pool image is smaller than that on delayed image and if no difinite soft tissue activity is noted on perfusion and blood pool images in clinically inactive patient.

  • PDF

Comparison and Estimation of Equilibrium Constants for Deoxyribonucleosides by Plate Theory and Moment Method (단이론과 모멘트방법을 이용한 데옥시리보뉴클레오사이드의 평형상수의 계산 및 비교)

  • Lee, Ju Weon;Row, Kyung Ho
    • Applied Chemistry for Engineering
    • /
    • v.8 no.3
    • /
    • pp.403-409
    • /
    • 1997
  • The equilibrium constants of five deoxyribonucleosides (dDyd, dUrd, dGuo, dThd, dAdo) were estimated by the plate theory and the moment method under isocratic conditions of the Reversed-Phase High Performance Liquid Chromatography (RP-HPLC). The mobile phase in this system was composed of water and organic modifiers(acetonitrile and methanol) The plate theory of linear adsorption isotherm was treated on the basis of continuous flow of eluent through the plates of the column. The moment method was utilized to find the equilibrium constant from the first absolute moment of experimental data. The equilibrium constants of five deoxyribonucleosides in the two methods were very close, and also the equilibrium constants calculated by capacity factor were similar to those by both the plate theory and the moment method. The equilibrium constant was expressed as a semi-log function of the quantity of organic modifier. Excellent agreements between the calculated elusion profile by the plate theory and the experimental data were observed.

  • PDF

A study on the establishment of pressure limit values of management monitoring in tunnel (터널 유지관리계측의 압력 관리기준치 설정에 관한 연구)

  • Woo, Jong-Tae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.1
    • /
    • pp.53-60
    • /
    • 2016
  • This study analyzed a monitoring data, based on the initial limit values of monitoring in subway, of earth pressure and pore water pressure. The data is obtained from 8 sections of the Seoul metropolitan subway line No 6, 7 and 9 in about 5 years. Also, a research is performed to set up the limit values of management monitoring, which will be applied to management monitoring in tunnel, through comparing the limit values of overseas management monitoring data and that of domestic management monitoring data. And the result obtained from comparison show that the safety phase is 60% of allowable pressure, the attention phase is 80% of allowable pressure and the precision analysis phase is 100% of allowable pressure. Also, we presented a method of management monitoring by the absolute value which can be easily applied easily in practical affairs.

A Study on the Establish Environmental Impact of Database of the Envelope System for Green Remodeling of Apartment Housing (공동주택의 그린 리모델링을 위한 외피시스템 환경영향 DB 구축에 관한 연구)

  • Lee, Jong Geon;Tae, Sung Ho;Chae, Chang-U;Kim, Rak Hyun
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.73-79
    • /
    • 2016
  • Purpose: In order to improve the energy performance of existing buildings, so actively promoted green remodeling business. Also, improvement of the performance of envelope system of apartment housing is an absolute. The purpose of implementation of the data base and application plan of the envelope system for green remodeling of apartment housing. Method: For this study, It proposed a classification system of green remodeling envelope system constructed actual to select the applicable representative method and input material of apartment housing for green remodeling. In this study, divided into construction waste processing stage and production phase of the material for the boundary of the system, and implementation the classification system of the envelope system for applicable green remodeling. For this, established 6 environmental impact categories database. Result: As a result of various suggestions were available for case study research, alternative combinations of existing combinations than six kinds of environmental impact insulation system with superior input materials combining 96 kinds, window system, 12 kinds for determining the applicability of the established database. Depending on the account for a large proportion if compared to the detailed analysis of the environmental impact resulting from the production phase and disposal phase was analyzed that the operating management of the necessary input materials. Is considered that the economic performance and integrated energy performance required by the applicable public housing green remodeling evaluation techniques considered for future improvements insulation sheath.

Icing Characteristics in Liquid-Phase Injection of LPG Fuel (액상분사식 LPG 인젝터의 아이싱 생성 특성 및 억제 방법)

  • Lee, Sun-Youp;Kim, Chang-Up;Choi, Kyo-Nam;Kang, Kern-Yong
    • Journal of ILASS-Korea
    • /
    • v.14 no.4
    • /
    • pp.147-152
    • /
    • 2009
  • Since a liquid-phase LPG injection system allows accurate control of fuel injection and increase in volumetric efficiency, it has advantages in achieving higher engine power and lower emissions compared to the mixer type LPG supplying system. However, this system also leads to an unexpected event called icing phenomenon which occurs when moisture in the air near the injector freezes and becomes frost around the nozzle hole due to extraction of heat from surrounding caused by instant fuel vaporization. As a result, it becomes difficult to control air/fuel ratio in engine operation, inducing exacerbation of engine performance and HC emission. One effort to mitigate icing phenomenon is to attach anti-icing injection tip in the end of nozzle. Therefore, in this study, the effect of engine operation parameters as well as surrounding conditions on icing phenomenon was investigated in a bench test rig with commercially-used anti-icing injection tips. The test results show that considerable ice was deposited on the surface near the nozzle hole of the anti-icing tip in low rpm and low load operating conditions in ambient air condition. This is because acceleration of detachment of deposited ice from the tip surface was induced in high load, high rpm conditions, resulting in decrease in frost accumulation. The results of the bench testing also demonstrate that little or no ice was formed at surrounding temperature below a freezing point since the absolute amount of moisture contained in the intake air is too small in such a low temperature.

  • PDF

A Literature Study of Gait (보행(步行)에 관(關)한 문헌적(文獻的) 고찰(考察))

  • Kim, Bum-Chol;Keum, Dong-Ho;Lee, Myeong-Jong
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.5
    • /
    • pp.79-95
    • /
    • 1996
  • When we see normal gait, gait cycle is seperated as stance phase and swing phase. It needs 6 determinant of gait of pelvic rotation, pelvic tilt, knee joint of stance phase, ankle and foot motion, ankle and knee motion, and pelvic movement to be accomplished. In addition, a joint and muscle action is accomplished biomechanically at the same time with its gait cycle. In oriental medicine, the relationships between chang-fu physiology and meridian physiology are summaried as follows ; ${\bullet}$ chang-fu physiology : Spleen manages the extremities. Liver manages soft tissues. Liver stores blood. Kidney stores essences. Kidney manages bones. ${\bullet}$ meridian physiology : The Leg Greater Yang Meridian and meridian soft tissues The Leg Yang-Myeong Meridian and meridian soft tissues The Leg Lesser Yang Meridian and meridian soft tissues The Leg Greater Yin Meridian and meridian soft tissues The Leg Lesser Yin Meridian and meridian soft tissues The Leg Absolute Yin Meridian and meridian soft tissues Especially, we can find out relations between in a "blood supplied feet can walk well" that explains "blood regulations and by liver nourishing effects"that is the closest concept of muscle. Abnormal gaits are due to three causes as following; first, physical defect secoud, pain third, nervous system or instability of muscle. In oriental medicine, we can know relationship in "atrophy, numbness, stroke, convulsion, muscular dystrophy of knee, rheumatoid arthritis, five causes of infantile growing defects, five causes of softening, sprain". Especially, atrophy is the most important symptom. Gait evaluation should be emphasized where a point can walk 8 feet to 10 feet considering stride width, stride length, the body weight center, stride number, flexion, extension, rotation of a joint as a standard factor. The point is we should find out something strange in a patient's side, front and back view. After that we should find out its cause as an index that we can observe abnormal findings in a joint and muscle.

  • PDF

Laboratory Markers Indicating Gastrointestinal Involvement of Henoch-Schönlein Purpura in Children

  • Hong, Jeana;Yang, Hye Ran
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.18 no.1
    • /
    • pp.39-47
    • /
    • 2015
  • Purpose: To determine clinically useful biochemical markers reflecting disease activity and/or gastrointestinal (GI) tract involvement in Henoch-$Sch{\ddot{o}}nlein$ purpura (HSP). Methods: A total of 185 children with HSP and 130 controls were included. Laboratory data indicating inflammation, standard coagulation, and activated coagulation were analyzed for the HSP patients, including measurements of the hemoglobin level, white blood cell (WBC) count, absolute neutrophil count (ANC), platelet count, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) level, prothrombin time, activated partial thromboplastin time, and fibrinogen, D-dimer, and fibrin degradation product (FDP) levels. The clinical scores of the skin, joints, abdomen, and kidneys were assessed during the acute and convalescence phases of HSP. Results: The WBC count, ANC, ESR, and CRP, fibrinogen, D-dimer, and FDP levels were significantly higher in the acute phase compared with the convalescent phase of HSP (p<0.05). The total clinical scores were more strongly correlated with the D-dimer (r=0.371, p<0.001) and FDP (r=0.369, p<0.001) levels than with inflammatory markers, such as the WBC count (r=0.241, p=0.001), ANC (r=0.261, p<0.001), and CRP (r=0.260, p<0.001) levels. The patients with GI symptoms had significantly higher ANC (median [interquartile range], 7,138.0 [4,446.4-9,470.0] vs. 5,534.1 [3,263.0-8,153.5], p<0.05) and CRP (0.49 [0.15-1.38] vs. 0.23 [0.01-0.67], p<0.05), D-dimer (2.63 [1.20-4.09] vs. 1.75 [0.62-3.39]), and FDP (7.10 [0.01-13.65] vs. 0.10 [0.01-7.90], p<0.05) levels than those without GI symptoms. Conclusion: D-dimer and FDPs are more strongly associated with disease activity and more consistently reflect GI involvement than inflammatory markers during the acute phase of HSP.