• 제목/요약/키워드: Absolute Temperature

검색결과 482건 처리시간 0.034초

Absolute Dimensions of Fifteen High Mass Main Sequence Eclipsing Binaries

  • Surina, Farung;Kang, Young-Woon
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2008년도 한국우주과학회보 제17권2호
    • /
    • pp.23.2-23.2
    • /
    • 2008
  • We presented the accurate absolute dimensions and distances of fifteen main sequence eclipsing binaries. The photometric and spectroscopic solutions of the binary systems were determined by analyzing light curves and radial velocity curves collected from the literature using the Wilson-Devinney computer code. The fifteen double-line spectroscopic binaries consist of nine detached systems; QX Car, AH Cep, CW Cep, ZZ Cep, XY Cet, RX Her, V451 Oph, VV Pyx and V760 Sco, six semi-detached systems; LY Aur, IU Aur, AO Cas, DM Per, V Pup and HU Tau. The temperatures of the binary systems were determined from their colors using the color-temperature calibrations. Then the temperature of each component star were determined using the temperature ratio which was adjusted from the light curves. We estimated the possible Z values and ages for the detached systems by adopting the Y2 (Yonsei-Yale) stellar evolutionary tracks. The derived distances are in good agreement of the Hipparcos distances whose error of parallax is within 10 %. Finally these well-investigated systems will be used as the standard eclipsing binaries.

  • PDF

Excellent toluene removal via adsorption by honeycomb adsorbents under high temperature and humidity conditions

  • Cho, Min-Whee;Kim, Jongjin;Jeong, Jeong Min;Yim, Bongbeen;Lee, Hyun-Jae;Yoo, Yoonjong
    • Environmental Engineering Research
    • /
    • 제25권2호
    • /
    • pp.171-177
    • /
    • 2020
  • Removal through adsorption is the most widely used and effective treatment method for volatile organic compounds (VOCs) in exhaust gases. However, at high temperatures and humidity, adsorption is competitive due to the presence of moisture and unsmooth physical adsorption thereby deteriorating adsorption performance. Therefore, water adsorption honeycomb (WAH) and VOCs adsorption honeycomb (VAH) were prepared to improve VOCs adsorption at high temperatures and humidity. Adsorbed toluene amounts on single honeycomb (SH), containing only VAH, and combined honeycomb (CH), containing WAH and VAH, were determined. Further, the toluene adsorption rates of honeycomb adsorbents mounted on rotary systems, VAH-single rotor (SR) and WAH/VAH-dual rotor (DR) were determined. Toluene adsorption by WAH/VAH-CH (inlet temperature: 40-50℃; absolute humidity: 28-83 gH2O/kg-dry air) was 1.6 times that by VAH-SH, and the water adsorption efficiency of WAH/VAH-CH was 1.7 times that of VAH-SH. The adsorption/removal efficiency of the WAH/VAH-DR (inlet temperature: 45℃; absolute humidity: 37.5 gH2O/kg-dry air) was 3% higher than that of VAH-SR. This indicates that the WAH at the rotor inlet selectively removed water, thereby improving the adsorption efficiency of the VAH at the outlet.

운전조건에 따른 전열교환기의 성능특성 연구 (A Study on the Characteristics of Total Heat Exchanger under Various Conditions)

  • 배철호;임영헌;드래바굴노라;박지열;곽경민;주의성;김영생;김지용
    • 설비공학논문집
    • /
    • 제17권10호
    • /
    • pp.891-897
    • /
    • 2005
  • The characteristics of energy Performance for total heat exchanger have been investigated under various conditions. In cooling operation the latent and enthalpy efficiency are affected by the difference of absolute humidity ratio between indoor and outdoor air. In addition to this the characteristics of absorbing material in the element affects the energy performance. Low dry bulb temperature of indoor air or high absolute humidity ratio in outdoor air give high latent and enthalpy efficiency even with the same temperature difference of dry bulb temperate between indoor and outdoor air.

산(Acid)류의 자연발화온도와 방화지연시간의 관계 (Relationship between Autoigniton Temperature(AIT) and Ignition Delay Time for Acids)

  • 하동명
    • 한국화재소방학회논문지
    • /
    • 제18권2호
    • /
    • pp.27-33
    • /
    • 2004
  • 화학물질의 최소자연발화온도의 정확한 지식은 산업화재를 예방하고 제어하는데 중요하다. 최소자연발화온도(AIT)는 화염이나, 스파크 없이 주위로부터 충분한 에너지를 받아서 스스로 점화할 수 있는 최저온도를 말한다. AIT는 실험 개시온도, 압력, 농도, 용기의 크기, 양론혼합비, 촉매, 증기의 농도, 발화지연시간 등 많은 인자에 영향을 받는다. 본 연구에서는 1994년에 제작된 ASTM E659-78 장치를 이용하여 산류(Acids) 발화지연시간과 AIT관계를 측정하였고, 실험에서 얻은 자료는 본 연구에서 제시한 예측 모델과 적은 오차 범위에서 일치하였다.

An Analytical Investigation on the Build-up of the Temperature Field due to a Point Heat Source in Shallow Coastal Water with Oscillatory Alongshore-flow

  • Jung, Kyung-Tae;Kim, Chong-Hak;Jang, Chan-Joo;Lee, Ho-Jin;Kang, Sok-Kuh;Yjm, Ki-Dai
    • Ocean and Polar Research
    • /
    • 제25권1호
    • /
    • pp.63-74
    • /
    • 2003
  • The build-up of the heat field in shallow coastal water due to a point source has been investigated using an analytical solution of a time-integral form derived by extending the solutions by Holley(1969) and also presented in Harleman (1971). The uniform water depth is assumed with non-isotropic turbulent dispersion. The alongshore-flow is assumed to be uni-directional, spatially uniform and oscillatory. Due to the presence of the oscillatory alongshore-flow, the heat build-up occurs in an oscillatory manner, and the excess temperature thereby fluctuates in that course and even in the quasi-steady state. A series of calculations reveal that proper choices of the decay coefficient as well as dispersion coefficients are critical to the reliable prediction of the excess temperature field. The dispersion coefficients determine the absolute values of the excess temperature and characterize the shoreline profile, particularly within the tidal excursion distance, while the decay coefficient determines the absolute value of the excess temperature and the convergence rate to that of the quasi-steady state. Within the e-folding time scale $1/k_d$ (where $k_d$ is the heat decay coefficient), heat build-up occurs more than 90% of the quasi-steady state values in a region within a tidal excursion distance (L), while occurs increasingly less the farther we go to the downstream direction (about 80% at 1.25L, and 70% at 1.5L). Calculations with onshore and offshore discharges indicate that thermal spreading in the direction of the shoreline is reduced as the shoreline constraint which controls the lateral mixing is reduced. The importance of collecting long-term records of in situ meteorological conditions and clarifying the definition of the heat loss coefficient is addressed. Interactive use of analytical and numerical modeling is recommended as a desirable way to obtain a reliable estimate of the far-field excess temperature along with extensive field measurements.

소형 공동주택의 동계 실내온습도 조사를 통한 결로방지 설계 기준온습도 설정방안 (The Design Criteria of the Indoor Temperature and Humidity for the Prevent Condensation of Small Apartment Buildings)

  • 김길태;김종엽;황하진;김경식
    • 토지주택연구
    • /
    • 제5권4호
    • /
    • pp.291-296
    • /
    • 2014
  • 공동주택은 기밀성능 향상에 의해 수증기의 배출이 어려워 졌다. 본 연구에서는 최근에 건설된 소형 공동주택의 실내 온습도의 조건에 대해 현장조사를 수행하여 결로방지 설계 시 필요한 실내 온습도기준을 제시하고자 한다. 조사지역으로는 대전과 성남 지역 3개 공동주택을 대상으로 하였으며, 1월부터 3월 동절기를 대상으로 측정하였다. 실내 온도는 $20{\sim}24^{\circ}C$, 상대습도는 40~60%이며, 조성된 습도는 외부의 영향보다는 주민의 다양한 특성에 의해 발생되었다. 주간(6:00~22:00)과 야간(22:00~6:00)을 비교하면, 야간에는 온도는 낮고 절대습도는 높아 결로발생 가능성이 높을 것으로 판단되었다. 누적 상대빈도와 절대습도를 사용하여 소형 공동주택의 설계 기준(온도, 상대습도)을 설정할 수 있다.

최대 절대값 기반 시계열 데이터 예측 모델 평가 기법 (Estimation Method of Predicted Time Series Data Based on Absolute Maximum Value)

  • 신기훈;김철;남상훈;박성재;유성수
    • 에너지공학
    • /
    • 제27권4호
    • /
    • pp.103-110
    • /
    • 2018
  • 본 논문에서는 Mean Absolute Percentage Error (이하 MAPE)와 Symmetric Mean Absolute Percentage (이하 sMAPE)의 새로운 접근법을 이용한 시계열 예측 모델의 평가 방법을 소개한다. MAPE, sMAPE에는 다음과 같은 문제점이 있다. 데이터 집합에서 관측 값이 0일 경우 평가할 수 없고, 관측 값이 0에 매우 가깝다면 과도한 평가 값을 측정한다. 관측 값과 예측 값 간에 동일한 오차를 가지더라도 다른 값으로 평가하는 문제도 가지고 있다. 동일한 오류 값이 과대 예측되었는지 아니면 과소 예측되었는지에 따라 다른 평가 값을 측정하거나 관측 값의 부호와 예측 값의 부호가 서로 다르면 그 오차는 평가 값에 반영되지 않는다. 이러한 문제는 Maximum Mean Absolute Percentage Error (이하 mMAPE)에 의해 해결하였다. 우리는 MAPE 평가 방법의 분모에서 관측 값을 사용하는 대신 최대 절대 값을 사용했다. 최대 절대 값이 1보다 작으면 분모를 제거하여 0 값이 정의되지 않은 문제와 미세한 값일 경우 과대 측정되는 문제를 해결하였다. Beijing PM2.5의 온도 데이터와 시뮬레이션 데이터를 통해 mMAPE와 다른 평가 방법들의 결과 값을 비교하였으며, 위의 문제들을 해결할 수 있음을 검증하였다.

미소구조물의 표면온도 측정 및 제어를 위한 다이오드 온도 센서 어레이 설계 (Diode Temperature Sensor Array for Measuring and Controlling Micro Scale Surface Temperature)

  • 한일영;김성진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1231-1235
    • /
    • 2004
  • The needs of micro scale thermal detecting technique are increasing in biology and chemical industry. For example, Thermal finger print, Micro PCR(polymer chain reaction), ${\mu}TAS$ and so on. To satisfy these needs, we developed a DTSA(Diode Temperature Sensor Array) for detecting and controlling the temperature on small surface. The DTSA is fabricated by using VLSI technique. It consists of 32 ${\times}$ 32 array of diodes (1,024 diodes) for temperature detection and 8 heaters for temperature control on a 8mm ${\times}$ 8mm surface area. The working principle of temperature detection is that the forward voltage drop across a silicon diode is approximately proportional to the inverse of the absolute temperature of diode. And eight heaters ($1K{\Omega}$) made of poly-silicon are added onto a silicon wafer and controlled individually to maintain a uniform temperature distribution across the DTSA. Flip chip packaging used for easy connection of the DTSA. The circuitry for scanning and controlling DTSA are also developed

  • PDF

저전압 저전력 듀얼 모드 CMOS 전류원 (Dual-mode CMOS Current Reference for Low-Voltage Low-Power)

  • 이근호
    • 한국정보통신학회논문지
    • /
    • 제14권4호
    • /
    • pp.917-922
    • /
    • 2010
  • 본 논문에서는 혼성모드 집적회로에서 이용 가능한 저전력 듀얼모드 CMOS 전류원 회로를 제안한다. MOS 소자의 전자이동도가 온도변화에 반비례하는 음의 온도계수 생성회로와 비례하는 양의 온도계수 생성회로의 합을 통해 변화하는 외부 온도에 독립적인 특성을 갖는 방식을 이용하였다. 특히, 두 개 이상의 출력을 얻어낼 수 있는 듀얼 출력단을 통해 정전류원을 얻을 수 있었다. 전류 분배를 통해 얻을 수 있는 듀얼모드 출력 전류값을 통해 차동 입출력 구조의 소자 및 필터 설계 등 아날로그 회로 영역에서 응용가능하며, 더불어 다양한 서브 블록 시스템 동작에 활용할 수 있는 유용한 특성을 지니고 있다. 저전압 저전력 특성을 보유하고 있는 제안된 전류원 회로는 2V 공급 전압하에서 0.84mW의 전력 소모값을 나타내었으며, 최종 출력값은 각각 $0.38{\mu}A/^{\circ}C$$0.39{\mu}A/^{\circ}C$의 변화율을 보여주었다. 제안된 회로는 $0.18{\mu}m$ n-well CMOS 공정을 이용하여 hspice 시뮬레이션 하였다.

벌꿀의 전처리 공정 중 Nominal 및 Absolute Filter 적용을 통한 제균 효과에 관한 연구 (Sterilization Effectiveness by Nominal and Absolute Filter in Pre-treatments of Honey)

  • 권기현;차환수;김병삼;성정민
    • 한국식품저장유통학회지
    • /
    • 제15권5호
    • /
    • pp.731-735
    • /
    • 2008
  • 본 연구는 벌꿀의 내포되어 있을 수 있는 미생물의 포자의 제균에 관한 연구로 선행연구로 일반세균, 대장균군, 살모넬라균, 포도상구균을 분석하였으며, 벌꿀 음료 제조 후 유통 중에 문제시 되어지고 있는 내열호산성균의 제균에 관한 연구결과이다. 분석을 위한 내열호산성균 실험법은 진공감압기를 이용하여 $0.45\;{\mu}m$ micro filter를 이용한 막분리 배양법을 이용하였다. 미생물 실험 결과 일반세균, 대장균군, 살모넬라균, 포도상구균은 모두 음성으로 나타났으며, 내열호산성균 제균을 위하여 식품의 일반 살균법을 적용한 결과 농도별 전해수 살균, 오존수 살균, 자외선살균, 일반 마이크로 필터 처리, 고온 가열 살균, microwave 살균 등 모든 제균 방법에서 균이 제어 되지 않는 것으로나타났다. 또한 마이크로 필터를 이용한 제균 처리에서도 일반 (nominal type) 필터를 사용하였을 경우 $44.8{\sim}64.5%$ 제균 효과를 나타낸 반면 absolute type의 필터를 사용하였을 경우 0.45, $0.8\;{\mu}m$ 마이크로 필터의 사용 시 모든 처리구에서 음성으로 나타나 제균 효과가 다른 살균법에 비해우수한 것으로 나타났다.