Development of Wireless Real Time River Water Quality Management System with GPS and GIS (GIS와 GPS를 연계한 무선 실시간 하천수질관리시스템 개발)

  • Yi, Jae-Eung;Ha, Sang-Min;Lee, Jong-Kook
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.4 s.7
    • /
    • pp.69-75
    • /
    • 2002
  • In this paper the development of a real time river water quality management system is described. This system can manage a river water quality fluctuation by finding out abnormal conditions quickly and exactly. The GIS based monitoring system collects various properties of river water quality through the wireless real time network. Tanchun, the first branch of the Han River was selected as the target basin of the system development. This system is composed of three parts - wireless real time field measuring system with a GPS receiver, a server computer and a GIS platform. After the first field test in Tanchun basin, the result showed the many possibilities of measuring various water quality properties in real time and storing the data and analyzing them within the GIS environment in real time in very efficient manners. It is expected that the developed system will contribute to the efficient management of a river water quality control and water quality related disaster prevention purposes.

Velocity-based decision of water quality measurement locations for the identification of water quality problems in water supply systems (상수도시스템 수질사고 인지를 위한 유속기반 수질계측기 위치 결정)

  • Hong, Sungjin;Lee, Chanwook;Park, Jiseung;Yoo, Do Guen
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.11
    • /
    • pp.1015-1024
    • /
    • 2020
  • Recently, water pollution accidents have continued to occur in pipelines such as red water Incheon and Seoul. In order to recognize this water quality problem, it is necessary to install a water quality sensor in an appropriate location and measure it in advance to detect or block the water supply to the water faucet of the shelter. However, there are limitations, such as maintenance costs, to installing multiple water meters in all pipelines. Therefore, this study proposed a methodology for determining and prioritizing the installation location of flow-based water quality sensor for the recognition of water quality problems in pipelines. We applied the proposed procedure to the pipe break scenario. The results of the determination of the location of the water quality sensor were presented by applying it to the pipe network that actually operates the emergency pipe in Korea. The result of the decision showed that in the event of abnormal situation caused by the destruction of individual pipes, the flow rate of the pipes around the aqueduct and the tank may change rapidly, resulting in water quality accidents caused by turbidity. In the future, it is expected that the water quality monitoring point selection method, such as establishing an external pipe operation plan for pipe cleaning, will utilize the procedure for determining the location of the water quality sensor according to the velocity.

AI-based smart water environment management service platform development (AI기반 스마트 수질환경관리 서비스 플랫폼 개발)

  • Kim, NamHo
    • Smart Media Journal
    • /
    • v.11 no.9
    • /
    • pp.56-63
    • /
    • 2022
  • Recently, the frequency and range of algae occurrence in major rivers and lakes are increasing due to the increase in water temperature due to climate change, the inflow of excessive nutrients, and changes in the river environment. Abnormal algae include green algae and red algae. Green algae is a phenomenon in which blue-green algae such as chlorophyll (Chl-a) in the water grow excessively and the color of the water changes to dark green. In this study, a 3D virtual world of digital twin was built to monitor and control water quality information measured in ecological rivers and lakes in the living environment in real time from a remote location, and a sensor measuring device for water quality information based on the Internet of Things (IOT) sensor. We propose to build a smart water environment service platform that can provide algae warning and water quality forecasting by predicting the causes and spread patterns of water pollution such as algae based on AI machine learning-based collected data analysis.

Drought impact on water quality environment through linkage analysis with meteorological data in Gamcheon mid-basin (기상자료와의 연계분석을 통한 수질환경에 대한 가뭄영향 연구 - 감천중권역을 대상으로)

  • Jo, Bugeon;Lee, Sangung;Kim, Young Do;Lee, Joo-Heon
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.823-835
    • /
    • 2023
  • Recently, due to the increase in abnormal climate, rainfall intensity is increasing and drought periods are continuing. These environmental changes lead to prolonged drought conditions and difficulties in real-time recognition. In general, drought can be judged by the amount of precipitation and the number of days without rainfall. In determining the impact of drought, it is divided into meteorological drought, agricultural drought, and hydrological drought and evaluation is made using the drought index, but environmental drought evaluation is insufficient. The river water quality managed through the total water pollution cap system is vulnerable to the effects of such drought. In this study, we aim to determine the drought impact on river water quality and quantify the impact of prolonged drought on water quality. The impact of rain-free days and accumulated precipitation on river water quality was quantitatively evaluated. The Load Duration Curve (LDC), which is used to evaluate the water quality of rivers, was used to evaluate water pollution occurring at specific times. It has been observed that when the number of consecutive rainless days exceeds 14 days, the target water quality in the mid-basin is exceeded in over 60% of cases. The cumulative rainfall is set at 28 days as the criteria, with an annual average rainfall of 3%, which is 32.1 mm or less. It has been noted that changes in water quality in rivers occur when there are 14 or more rainless days and the cumulative rainfall over 28 days is 32.1 mm or less in the Gamcheon Mid-basin. Based on the results of this study, it aims to quantify the drought impact and contribute to the development of a drought water quality index for future environmental droughts.

A Study on the cleansing of water data using LSTM algorithm (LSTM 알고리즘을 이용한 수도데이터 정제기법)

  • Yoo, Gi Hyun;Kim, Jong Rib;Shin, Gang Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.501-503
    • /
    • 2017
  • In the water sector, various data such as flow rate, pressure, water quality and water level are collected during the whole process of water purification plant and piping system. The collected data is stored in each water treatment plant's DB, and the collected data are combined in the regional DB and finally stored in the database server of the head office of the Korea Water Resources Corporation. Various abnormal data can be generated when a measuring instrument measures data or data is communicated over various processes, and it can be classified into missing data and wrong data. The cause of each abnormal data is different. Therefore, there is a difference in the method of detecting the wrong side and the missing side data, but the method of cleansing the data is the same. In this study, a program that can automatically refine missing or wrong data by applying deep learning LSTM (Long Short Term Memory) algorithm will be studied.

  • PDF

A Study of Changes in the Water Quality of Agricultural Reservoirs due to Drought (가뭄으로 인한 농업용 저수지의 수질 변화 연구)

  • Cho, SungHyen;Hwang, Soonho;Lee, Dongguen;Lee, Guntaek;Choi, Jung-Hoon
    • Journal of the Korean earth science society
    • /
    • v.43 no.1
    • /
    • pp.110-118
    • /
    • 2022
  • Frequent drought damage has resulted in the polarization of water resources. In Korea, local periodic abnormal droughts continued to occur between 2011 and 2017, resulting in decreased water storage rates of small-scale reservoirs designed with a frequency of 10-year droughts. This decrease can degrade water quality and limit the use of already secured quantities. Therefore, to prepare for and overcome drought, quality management and recalculation of drought frequency are required. This study estimates the potential pollutants causing quality changes in the reservoir. In addition, it reviews the decrease in storage and consequent changes in the quality of a reservoir during drought.

Analysis of effects of drought on water quality using HSPF and QUAL-MEV (HSPF 및 QUAL-MEV를 이용한 가뭄이 수질에 미치는 영향 분석)

  • Lee, Sangung;Jo, Bugeon;Kim, Young Do;Lee, Joo-Heon
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.6
    • /
    • pp.393-402
    • /
    • 2023
  • Drought, which has been increasing in frequency and magnitude due to recent abnormal weather events, poses severe challenges in various sectors. To address this issue, it is important to develop technologies for drought monitoring, forecasting, and response in order to implement effective measures and safeguard the ecological health of aquatic systems during water scarcity caused by drought. This study aimed to predict water quality fluctuations during drought periods by integrating the watershed model HSPF and the water quality model QUAL-MEV. The researchers examined the SPI and RCP 4.5 scenarios, and analyzed water quality changes based on flow rates by simulating them using the HSPF and QUAL-MEV models. The study found a strong correlation between water flow and water quality during the low flow. However, the relationship between precipitation and water quality was deemed insignificant. Moreover, the flow rate and SPI6 exhibited different trends. It was observed that the relationship with the mid- to long-term drought index was not significant when predicting changes in water quality influenced by drought. Therefore, to accurately assess the impact of drought on water quality, it is necessary to employ a short-term drought index and develop an evaluation method that considers fluctuations in flow.

Development of Continuous Water Quality Monitoring System using the Daphnid Daphnia sp. (국내산 물벼룩 Daphnia sp.를 이용한 연속적인 수질모니터링 장치 개발)

  • Yoon, Sungjin;Lee, Sungkyu;Park, Hanoh
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.1
    • /
    • pp.36-43
    • /
    • 2008
  • To develop the continuous water quality monitoring system using the daphnid Daphnia sp., the growth of test animal, sensitivity, and behaviour response of toxicants were observed. Growth of test animal significantly increased with increasing the food density under the 90~105 mg/L ($CaCO_3$) hardness, except the concentration of food (Chrollela sp.) was exceeded than optimal food supply. Behaviour responses of test animals were continuously analyzed by changes of fractal dimension value (FDV). The FDV sharply decreased after exposure to the concentrations of 0.13 mg/L copper, 0.06 mg/L lead, and 0.38 mg/L cadmium. In these concentrations, mortality and abnormal behaviour of daphnids exhibited within ca. 1.0-h after exposure. Comparison of 24-h $LC_{50}$ values with other zooplankton species indicated that sensitivity of the Daphnia sp. was higher than most zooplankton for lead, and brain shrimp, rotifer, and water flea (Ceriodaphnia dubia, D. magna) for copper, and brain shrimp, water flea (D. lumholzi), and amphipod for cadmium. Based on the above experimental results, significant relationship between toxicity and behaviour response of Daphnia sp. was supported the high potential of water quality monitoring system. Consequently, behavioural monitoring method in this study suggests a good estimation tool for detection of the discharged toxicants in water body and for ecotoxicological assessment aquatic organisms.

Determination of Optimal Pressure Monitoring Locations of Water Distribution Systems Using Entropy Theory and Genetic Algorithm (엔트로피 이론과 유전자 알고리즘을 결합한 상수관망의 최적 압력 계측위치 결정)

  • Chang, Dong-Eil;Ha, Keum-Ryul;Jun, Hwan-Don;Kang, Ki-Hoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.1-12
    • /
    • 2012
  • The purpose of water distribution system is supplying water to users by maintaining appropriate pressure and water quality. For efficient monitoring of the water distribution system, determination of optimal locations for pressure monitoring is essential. In this study, entropy theory was applied to determine the optimal locations for pressure monitoring. The entropy which is defined as the amount of information was calculated from the pressure change due to the variation of demand reflected the abnormal conditions at nodes, and the emitter function (fire hydrant) was used to reproduce actual pressure change pattern in EPANET. The optimal combination of monitoring points for pressure detection was determined by selecting the nodes receiving maximum information from other nodes using genetic algorithm. The Ozger's and a real network were evaluated using the proposed model. From the results, it was found that the entropy theory can provide general guideline to select the locations of pressure sensors installation for optimal design and monitoring of the water distribution systems. During decision-making phase, optimal combination of monitoring points can be selected by comparing total amount of information at each point especially when there are some constraints of installation such as limitation of available budget.

A Study on the Implementation of Intelligent Diagnosis System for Motor Pump (모터펌프의 지능형 진단시스템 구현에 관한 연구)

  • Ahn, Jae Hyun;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.4
    • /
    • pp.87-91
    • /
    • 2019
  • The diagnosis of the failure for the existing electrical facilities was based on regular preventive maintenance, but this preventive maintenance was limited in preventing a lot of cost loss and sudden system failure. To overcome these shortcomings, fault prediction and diagnostic techniques are critical to increasing system reliability by monitoring electrical installations in real time and detecting abnormal conditions in the facility early. As the performance and quality deterioration problem occurs frequently due to the increase in the number of users of the motor pump, the purpose is to build an intelligent control system that can control the motor pump to maximize the performance and to improve the quality and reliability. To this end, a vibration sensor, temperature sensor, pressure sensor, and low water level sensor are used to detect vibrations, temperatures, pressures, and low water levels that can occur in the motor pump, and to build a system that can identify and diagnose information to users in real time.