• Title/Summary/Keyword: Abnormal voltage

Search Result 192, Processing Time 0.023 seconds

Optimization of DC Operating Voltage for GDT-Adopted SPD (가스방전관(GDT)을 적용한 서지보호장치 회로의 DC 동작전압 최적조건 고찰)

  • Choi, Jong-Min;Jeon, Tae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.92-98
    • /
    • 2012
  • It is made compulsory to install SPD for the purpose of protecting electric and electronic devices when an abnormal voltage such as lightning occurs to power line using power frequency of 60Hz. Recently, the high speed communication technology utilizing power line is receiving attention again as a communication technology for smart grid. The SPD influences the performances of power line communication when using SPD and power line communication system together. In order to improve the performance of power line communication, a proposed scheme for series connection of gas discharge tube to ZnO varistor was presented. This paper measured the impacts of series connection of GDT to SPD using ZnO varistor on the limit voltage of Class III SPD. This paper also presented the DC operating voltage of GDT which satisfies the limit voltage of power line communication system and SPD simultaneously.

Preparation of Low Voltage ZnO Varistor Using Seed Grain Method and Its Electrical Properties (종결정법을 이용한 저전압 ZnO 배리스터의 제조 및 전기적 특성)

  • 강승구;오재희
    • Journal of the Korean Ceramic Society
    • /
    • v.25 no.5
    • /
    • pp.552-560
    • /
    • 1988
  • ZnO low voltage varistor was obtained by varying a) the amount of seed grains, b) the size of seed grains, and c) sintering temperature. Also, the optimum condition for fabricating the ZnO seed grains was studied. Large ZnO seed grains were obtained by washing a ZnO sintered body containing 1m/of BaCO3 in boiling water. When the seed grains were added, abnormal grain growth occurred, and the varistor voltage sharply decreased. However, when more than 5w/o of seed grain content was added, the varistor voltage gradually increased. When 10w/o seed grains of 75~106${\mu}{\textrm}{m}$ were added and sintered for 2 hours at 1200 to 125$0^{\circ}C$, low voltage varistor properties with V1mA/mm of 19V/mm and nonlinear exponent ($\alpha$) of 12 occurred.

  • PDF

Coordinated Voltage-Reactive Power Control Schemes Based on PMU Measurement at Automated Substations

  • Choi, Yun-Hyuk;Kang, Sang-Gyun;Lee, Byongjun
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1400-1407
    • /
    • 2015
  • This paper deals with methodology to control an automatic substation system. The control system can predict the power system condition by a voltage stability index (VSI). The strategies in this paper is called as Voltage-Reactive Power Control (VRPC), which regulates an abnormal voltage of a target substation by using coordination between tap changers and shunt capacitor/reactor. This method is efficient for better voltage profile. The monitoring substation includes whole of substations around the contingency event. The control quantities of the monitoring substations are decided by the calculation of the VSI, called as a Z-index. Case studies with BC Hydro-Quebec system are presented to illustrate this approach using real-time simulator.

A novel PLL control method for robust three-phase thyristor converter under sag and notch conditions

  • Lee, Changhee;Yoo, Hyoyol
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.87-88
    • /
    • 2014
  • The paper presents a novel phase locked loop(PLL) control method for robust three-phase thyristor dual converters under sag, notch, and phase loss conditions. This method is applied to three line to line voltages of grid to derive three phase angle errors from three separated single-phase PLLs. They can substitute for abnormal phase to guarantee the synchronization in the various grid fault conditions. The performance of novel PLL with moving average method is verified through simulations.

  • PDF

Laterally Encapsulated Cathode Structure for DC Plasma Display Panels

  • Esfahani, M.Mokhlespour;Mohajerzadeh, S.;Goodarzi, A.;Rouhi, N.;Tarighat, R.S.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1233-1236
    • /
    • 2005
  • We report a novel approach for encapsulating of cathode electrodes in DC plasma pixels. Anode and cathode electrodes are laterally placed on a single substrate. The encapsulated electrode minimizes the sputtering of the cathode without significantly altering the turn-on voltage-pressure characteristics. An abnormal glow in current-voltage characteristics is also observed.

  • PDF

Bending Analysis of PVDF Piezoelectric Film (PVDF 압전필름의 굽힘에 대한 해석)

  • 이용국;소형종;유영한;안형근;한득영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.339-342
    • /
    • 1999
  • The equation of output voltage from the PVDF was derived. When impact force applied to the PVDF films of cantilever beam and one-end fixed, other-end supported beam structure, output voltage equation induced. Experimental output voltages by falling ball agreed quite well with induced theoretical data. This PVDF film showers to be in high possibility in a warning system of abnormal pulse rate and breathing, and in detecting impact force and/or mechanical energy.

  • PDF

Improved Phase and Harmonic Detection Scheme using Fast Fourier Transform with Minimum Sampling Data under Distorted Grid Voltage (최소 샘플링의 고속푸리에 변환을 이용한 비정상 계통의 향상된 위상추종 및 고조파 검출 기법)

  • Kim, Hyun-Sou;Kim, Kyeong-Hwa
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.1
    • /
    • pp.72-80
    • /
    • 2015
  • In distributed generation systems, a grid-connected inverter should operate with synchronization to grid voltage. Considering that synchronization requires the phase angle of grid voltage, a phase locked loop (PLL) scheme is often used. The synchronous reference frame phase locked loop (SRF-PLL) is generally known to provide reasonable performance under ideal grid voltage. However, this scheme indicates performance degradation under the harmonic distorted or unbalanced grid voltage condition. To overcome this limitation, this paper proposes a phase and harmonic detection method of grid voltage using fast Fourier transform (FFT). To reduce the calculation time of FFT algorithm, minimum sampling data is taken from the voltage measurement to determine the phase angle and the magnitude of harmonic components. An experimental test setup for a grid-connected inverter system has been constructed. By comparative simulations and experiments under various abnormal grid voltage conditions, the proposed scheme has been proven to effectively track the phase angle of the grid voltage.

Detection of abnormal conditions and monitoring of surface ginding characteristics by acoustic emission (AE에 의한 평면연삭의 가공특성 감시 및 이상진단)

  • Lim, Y.H.;Kwon, D.H.;Choi, M.Y.;Lim, S.J.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.4
    • /
    • pp.100-110
    • /
    • 1995
  • This paper aims at reviewing the possibility of application over normal or abnormal, detection used by AE, and the characteristics of grinding processes. In this study, when WA-vitri-fied ' resinoid bond grinding wheels:36 kinds of grinding wheel and grinding depth were tuned at the surface grinding, the zone of AE signal generation is theoretically modelled and reviewed by grinding processes. The variation of grinding resistance( F$n^{9}$ $F_{t}$) and AE signal is detected in-process by the use of AE measuring system. The tests are carried out in accordance with grain size and grade of grinding wheels, and work-pieces-STD11 and STD61. According to the experiment's results, the following can be expected;as grinding time passes by, the relation of grinding depth and quantity of AE signal, observing on AE signal and grinding burn suggest the characteristics of grinding processes and evalution on the possibility of control of grinding machine, and monitoring abnormal conditions.e, and monitoring abnormal conditions.

  • PDF

The Influence of Inductive Loads on Power System Voltage Stabilization (유도부하가 전력 계통의 전압안정화에 미치는 영향)

  • Chung, Jai-Kil;Park, Sung-Dae;Cho, Yang-Haeng;Oh, Chang-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.35-37
    • /
    • 1993
  • This paper shows that the presence of constant impedance loads and induction motors in power system's loading contents can lead to transient voltage instabilities during normal system manipulations such as switchings. The abnormal induction motor characteristics during system transients which initiate the voltage instabilities are illustrated. The influence of motor and network parameters, such as motor inertia mechanical load quantity and nature on the severity of the voltage instability are studied.

  • PDF

On-Line Assessment of High Voltage Motor Condition using the Motor Performance Monitor (MPM을 이용한 고압전동기 운전중 상태 평가)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1589-1593
    • /
    • 2008
  • The condition of a high voltage motor was monitored with the motor performance monitor (MPM) at the motor control center. The MPM detected defects in the rotor bar and end ring and input power according to motor and load conditions. The assessment of the condition of a coal pulverizer motor indicated it was clearly in good condition in terms of the rotor bars, over voltage, and motor performance. However, the side bands at frequency, 56.48 Hz indicated existence of rotor end-ring fault. The large torque ripple indicated abnormal operating conditions. After visual inspection, it has been observed that an impeller blade of the circulating water pump was broken off causing the irregular torque pattern.