• Title/Summary/Keyword: Abnormal low temperature

Search Result 125, Processing Time 0.028 seconds

Abnormal Water Temperature Prediction Model Near the Korean Peninsula Using LSTM (LSTM을 이용한 한반도 근해 이상수온 예측모델)

  • Choi, Hey Min;Kim, Min-Kyu;Yang, Hyun
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.3
    • /
    • pp.265-282
    • /
    • 2022
  • Sea surface temperature (SST) is a factor that greatly influences ocean circulation and ecosystems in the Earth system. As global warming causes changes in the SST near the Korean Peninsula, abnormal water temperature phenomena (high water temperature, low water temperature) occurs, causing continuous damage to the marine ecosystem and the fishery industry. Therefore, this study proposes a methodology to predict the SST near the Korean Peninsula and prevent damage by predicting abnormal water temperature phenomena. The study area was set near the Korean Peninsula, and ERA5 data from the European Center for Medium-Range Weather Forecasts (ECMWF) was used to utilize SST data at the same time period. As a research method, Long Short-Term Memory (LSTM) algorithm specialized for time series data prediction among deep learning models was used in consideration of the time series characteristics of SST data. The prediction model predicts the SST near the Korean Peninsula after 1- to 7-days and predicts the high water temperature or low water temperature phenomenon. To evaluate the accuracy of SST prediction, Coefficient of determination (R2), Root Mean Squared Error (RMSE), and Mean Absolute Percentage Error (MAPE) indicators were used. The summer (JAS) 1-day prediction result of the prediction model, R2=0.996, RMSE=0.119℃, MAPE=0.352% and the winter (JFM) 1-day prediction result is R2=0.999, RMSE=0.063℃, MAPE=0.646%. Using the predicted SST, the accuracy of abnormal sea surface temperature prediction was evaluated with an F1 Score (F1 Score=0.98 for high water temperature prediction in summer (2021/08/05), F1 Score=1.0 for low water temperature prediction in winter (2021/02/19)). As the prediction period increased, the prediction model showed a tendency to underestimate the SST, which also reduced the accuracy of the abnormal water temperature prediction. Therefore, it is judged that it is necessary to analyze the cause of underestimation of the predictive model in the future and study to improve the prediction accuracy.

Effects of Microstructural Parameters on the Reduction of Area in Hyper-eutectoid Steel Wires (과공석 강선에서 미세조직 인자들이 단면감소율에 미치는 영향)

  • An, K.S.;Park, J.H.;Bae, H.J.;Nam, W.J.
    • Transactions of Materials Processing
    • /
    • v.25 no.5
    • /
    • pp.306-312
    • /
    • 2016
  • Effects of manufacturing conditions, such as austenitizing temperature, patenting temperature and carbon content in steels, on mechanical properties, especially on reduction of area (RA), of hyper-eutectoid steel wires were investigated. RA increased and then decreased with transformation temperature. This was attributed to the presence of abnormal structures in steels transformed at low transformation temperatures and the occurrence of shear cracking during tensile testing of steels transformed at high transformation temperatures. The increase of austenitizing temperature resulted in the increased austenite grain size and consequently the decrease of RA. The decrease of RA with increasing the carbon content in steels was attributed to the increased fraction of cleavage fracture in tensile fractured surfaces.

Hysteresis on Boiling Heat Transfer at Low Temperature on Enhanced Tubes in a Flooded Evaporator (만액식 증발기의 열전달 촉진관에서 저온 비등열전달의 이력현상 특성)

  • 윤현필;박종익;정진희;강용태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.254-260
    • /
    • 2003
  • The boiling characteristics for R134a are studied to clarify the hysteresis at low temperature on enhanced tubes of a flooded evaporator. Initial boiling conditions, refrigerant temperature, and inlet temperature of the chilled water are considered as the key parameters of the experiments. Unlike previous studies of the boiling heat transfer with uniform heat flux and uniform wall temperature, the wall temperature was varied along the tube. In, this study, it was found that the hysteresis of the temperature overshoot (705) at the onset of nucleate boiling initially at the inlet section of the tube. It is also concluded that the abnormal operation can be avoided during the low temperature boiling if the refrigeration system is started with LMTD larger than $3.4^{\circ}C$ at initial stage and larger than $1.0^{\circ}C$ at normal stage.

The effect of Far-infrared on survival rate and genetic mutation of Escherichia-coli (원적외선이 대장균의 생존율과 돌연변이에 미치는 영향)

  • Kim, Jae-Yoon;Park, Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.3
    • /
    • pp.637-642
    • /
    • 2001
  • Hershel found out Infrared for the first time, in the Industrial Revolution the Infrared and FlR had been begun to use making products. FIR with low temperature can deeply penetrate on the human body composed things without troublesome. since FIR has effectively operated on the human body at low temperature (35-40$^{\circ}$C). When FIR penetrated on the human body, it would inhibit the abnormal genes and cells expression, and then information of DNA and RNA would be reexpressed for arranging DNA and RNA abnormal state. As FIR's receptors in the body, it colud be presumed that N-glycosyl linkage of purine and deoxyribose, RNA splicing process. and Heat shock protein. To radiate optimized FIR, in this study, we made the FIR radiation compound and instrument for unharming biological things. According to the results, the FIR radiation to E. coli., it did not induce genetic mutations and change the survival rate of E.coli.

  • PDF

On the Abnormal Low Temperature Phenomenon of the Yellow Sea Bottom Cold Water in Summer, 1981 (1981年 夏季 黃海底層冷水의 理想底水溫現象)

  • Yang, Sung-Ki;Cho, Kyu-Dae;Hong, Chol-Hoon
    • 한국해양학회지
    • /
    • v.19 no.2
    • /
    • pp.125-132
    • /
    • 1984
  • The abnormal low water temperature phenomenon of the Yellow Sea Bottom Cold Water in summer, 1981 is studied on the basis of the oceanographical data collected by the National Fisheries University of Pusan in July, 1981 and Fisheries Research and Development Agency of Korea from 1960 to 1981 and meteorological data within the same 22 years. In winter, 1980 the northwesterly monsoon was vary predominant and the air temperature was lower than that of mean year by 1∼8$^{\circ}C$ and also the surface temperature was lower 1∼3$^{\circ}C$. And then the temperature of the Yellow Sea Bottom Cold Water in summer, 1981 became lower 2∼3$^{\circ}C$ than that of mean year and the influence of this cold water was extended to about 50 miles off the coast of Cheju Island. Comparing with mean year, the water temperature at 30m depth in February, 1981 was lower by 1∼2$^{\circ}C$ in entire regions except near sea of Sohuksando and at 50m depth in August, 1981, it was lower by about 3.5$^{\circ}C$. Particularly, the offshore of Hongdo shower value of 5$^{\circ}C$ than that of mean year. It was found that the abnormal low water temperature phenomenon of Yellow Sea Bottom Cold Water in summer, 1981 resulted from the sea surface cooling by the predominant northwestly monsoon and abnormally low air temperature in winter, 1980.

  • PDF

DEVELOPMENT OF AN AUTOMATIC ENVIRONMENTAL CONTROL SYSTEM FOR LOW TEMPERATURE STORAGE HOUSE USING INTERNET

  • Chung, H.;Yun, H.S.;Lee, W.O.;Lee, K.H.;Cho, Y.K.;Park, W.K.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.676-683
    • /
    • 2000
  • For high quality storage of agricultural products, temperature, humidity and gas conditions in a storage house should be controlled properly. But most of the low temperature storage house is depending on temperature control. This study aimed to develop an automatic control system for low temperature storage house that can control storage conditions such as temperature, humidity and $CO_2$ gas concentration. The developed system alarms the user, by telephone or beeper, when abnormal condition has occurred. The farmer can also monitor the inside condition of warehouse in his residence, by Internet. From the results of the performance test, the temperature and relative humidity in the warehouse is controlled within the range of ${\pm}0.5^{circ}C$ and ${\pm}2%$, respectively.

  • PDF

Characteristics and Synoptic Causes on the Abnormal Heat Occurred at Miryang in 2004 (2004년 밀양의 이상더위의 특징과 종관적 원인)

  • Byun, Hi Ryong;Hwang, Ho Seong;Go, Hye Young
    • Atmosphere
    • /
    • v.16 no.3
    • /
    • pp.187-201
    • /
    • 2006
  • During summer (JJA) of 2004, a record-high temperature in Korea appeared at Miryang ($38.5^{\circ}C$ on July 30). Moreover, Miryang showed the most frequent occurrence (25 days in JJA) of the daily highest temperature among observational sites in Korea. Based on meteorological analysis, it is found that this phenomenon is caused by neither the global warming effect nor the urban climate effect. It is caused by the mesoscale and synoptic and/or global scale atmospheric circulations, as evidenced by several factors described below. Firstly, the hottest areas have normally occurred not at a point but over an area, particularly along an axis connecting Sancheong and Daegu. But in 2004, this axis has moved southward and locates over Namhae-Miryang due to northerlies that were induced by the heating effect related to the low snow-cover on the Tibet Plateau. Secondly, although the maximum temperature was the highest among observational sites in Korea, the daily mean temperature and the number of nights with air temperature over $25^{\circ}C$ were not the highest at Miryang. Thirdly, the downdraft induced by the second circulation of typhoon and abnormal development of the North-Pacific High were found to have exerted an important role.

A Experimental Study on the Fire Safety of Drum-type Electric Washing Machine (드럼세탁기 화재안전성 확보를 위한 실험연구)

  • Hong, Sung-Ho;Lee, Sang-Hyun;Park, Sang-Tae;Yu, Hyun-Jong;Jeon, Woong-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.131-133
    • /
    • 2008
  • This study presents on the analysis fire hazards of drum type electric washing machine. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate under the normal condition and abnormal condition. The experiment under the abnormal condition is simulated in safety device failure, situation of accumulated dust and tracking phenomenon caused by humidity. The results show that fire hazard is high at the abnormal condition. In this paper, we suggest to use the safety device of low operating temperature in electric washing machine for reducing fire hazard.

  • PDF

A Experimental Study on the Fire Hazards in Drum-Type Electric Washing Machine (건조일체형 드럼세탁기의 화재위험성에 관한 실험연구)

  • Hong, Sung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.328-331
    • /
    • 2008
  • This study presents on the analysis fire hazards of drum type electric washing machine. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate under the normal condition and abnormal condition. The experiment under the abnormal condition is simulated in safety device failure, situation of accumulated dust and tracking phenomenon caused by humidity. The results show that fire hazard is high at the abnormal condition. In this paper, we suggest to use the safety device of low operating temperature in electric washing machine for reducing fire hazard.

Mechanism of Far-infrared how to affect the human body (원적외선의 인체작용메카니즘)

  • Kim, Jae-Yoon;Park, Young-Han;Park, Don-Mork;Park, Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.2
    • /
    • pp.477-482
    • /
    • 2001
  • Until now, it has not been well known for Far-infrared(FIR) how to affect to the human body. We introduced and presumed the mechanism of FIR based on molecular biology in this study, as below. The human body is composed of proteins which get easily changed by a thermal factor (about 42 $^{\circ}$C over). FIR with low temperature can deeply penetrate on the human body composed things without troublesome, since FIR has effectively operated on the human body at low temperature (35-40 $^{\circ}$C). When FIR penetrated on the human body, it would inhibit the abnormal genes and cells expression, and then information of DNA and RNA would be reexpressed for arranging DNA and RNA abnormal state. As FIR's receptors in the body, it colud be presumed that N-glycosyl linkage of purine and deoxyribose, RNA splicing process, and heat shock protein.

  • PDF