• Title/Summary/Keyword: Abnormal cooling

Search Result 39, Processing Time 0.025 seconds

Noise Reduction of Traction Motor for High Speed Train (고속전철용 견인전동기 소음개선)

  • Kim, Jung-Chul;Kim, Dea-Kwang;Kim, Bong-Chul;Park, Yeong-Ho;Choi, Jong-Mook
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.95-100
    • /
    • 2007
  • The traction motor for High Speed Train is being required reliability and stability for high-speed operation. And also required low noise level, high performance, compact size owing to the space and weight limitation for attaching to train, etc. As a result of requiring the low noise level and high power capacity, it is adopted forced-air-ventilation insead of self-ventilation that is generally used on electric multiple unit. Traction motor is cooled by cooling air through the air-ventilation hole. When the traction motor is operated with forced-air-ventilation, there is some abnormal noise in the specific RPM. This paper is dealing with the method to reduce the resonance phenomena by adopting the rotor blade.

  • PDF

An Operation Status Analysis of Library Building using BEMS Data; Energy Performance Evaluation on Initial Stage of Completion (BEMS 데이터를 활용한 도서관 건물의 운전현황 분석 -준공 초기단계의 건물 에너지 성능 평가)

  • Park, Seong-cheol;Ha, Ju-wan;Kim, Hwan-yong;Song, Young-hak
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.669-679
    • /
    • 2018
  • Energy consumption savings in buildings should be reviewed in diverse areas such as air conditioning system and lighting responsible for cooling and heating, and energy management systems such as BAS (Building Automation System) and BEMS (Building Energy Management System) are introduced to improve energy consumption efficiency and to promote economic control of related facilities by integrated management of energy generated and consumption in buildings. The measured building of this study uses regenerative geothermal system. Measured values of heat pump and system COP were 4.7 and 4.2 respectively, and they were found to be higher 11.9% and 23.5% than rated values. As a result of analyzing the air conditioning and lighting energy from the first floor to the fourth floor performing the air conditioning, the second and third floors, which have a high frequency of use, are compared with the first and fourth floors 50% higher energy consumption ratio. On the other hand, the general heat storage system uses the nighttime power of the previous day to store heat and use it the next day. The total number of days of abnormal operation during the summer season is 61 days. The electricity cost corresponding to the abnormal operation is 1,840,641 KRW, and the normal operation using the nighttime power is 1,363,561 KRW, which is difference of 477,080 KRW, 35% increase in cost. We will utilize it as the main data of BEMS through analysis of winter operation characteristics as well as summer operation characteristics.

On the Abnormal Low Temperature Phenomenon of the Yellow Sea Bottom Cold Water in Summer, 1981 (1981年 夏季 黃海底層冷水의 理想底水溫現象)

  • Yang, Sung-Ki;Cho, Kyu-Dae;Hong, Chol-Hoon
    • 한국해양학회지
    • /
    • v.19 no.2
    • /
    • pp.125-132
    • /
    • 1984
  • The abnormal low water temperature phenomenon of the Yellow Sea Bottom Cold Water in summer, 1981 is studied on the basis of the oceanographical data collected by the National Fisheries University of Pusan in July, 1981 and Fisheries Research and Development Agency of Korea from 1960 to 1981 and meteorological data within the same 22 years. In winter, 1980 the northwesterly monsoon was vary predominant and the air temperature was lower than that of mean year by 1∼8$^{\circ}C$ and also the surface temperature was lower 1∼3$^{\circ}C$. And then the temperature of the Yellow Sea Bottom Cold Water in summer, 1981 became lower 2∼3$^{\circ}C$ than that of mean year and the influence of this cold water was extended to about 50 miles off the coast of Cheju Island. Comparing with mean year, the water temperature at 30m depth in February, 1981 was lower by 1∼2$^{\circ}C$ in entire regions except near sea of Sohuksando and at 50m depth in August, 1981, it was lower by about 3.5$^{\circ}C$. Particularly, the offshore of Hongdo shower value of 5$^{\circ}C$ than that of mean year. It was found that the abnormal low water temperature phenomenon of Yellow Sea Bottom Cold Water in summer, 1981 resulted from the sea surface cooling by the predominant northwestly monsoon and abnormally low air temperature in winter, 1980.

  • PDF

Studies on the Effect of Low Temperature Treatment at Meiotic, Heading and Seedling Stage in Paddy Rice (수도의 장해형 냉해에 관한 연구)

  • Hong-Suk Lee;Hyung-Yull Cho;Pyeong-Ki Yim;Hoon Heu
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.15
    • /
    • pp.85-97
    • /
    • 1974
  • In order to clarify the inducing conditions and cause of sterility in rice plants, 4 varieties were cooled at 3 different levels of temperature combined with 3 different levels of treatment period. And 19 varieties were tested to examine the varietal difference of cold resistance. The results obtained were summarized as follows; 1. There were significant varietal differences in the effect of cooling treatment at meiotic stage. Suwon 213-1 was induced heavy sterility by 3 day cooling treatment at 17.5$^{\circ}C$ whereas Hayayuki, Nongpaik and Jinheung were induced a little sterility by 3 day cooling treatment at 15$^{\circ}C$ and 5 day treatment at 17.5$^{\circ}C$. The per cent of grain fertility was correlated significantly with the delayed days to heading, the degree of panicle extraction (Suwon 213-1, Nongpaik, Jinheung), culm length (Nongpaik, Suwon 213-1), and Auricle distance (Suwon 213-1). The degree of sterility was able to be estimated from the linear regression equation between the degree of panicle extraction (distance from panicle neck to flag leaf) and fertility percentage. In the case of heavy cold damage by the treatment of low temperature at meiotic stage, the rice plant had somewhat lower pollen density per anther, small and ununiform anther and pollen in size, and more sterile pollen grains. Suwon 213-1 showed anthesis in almost all spikelets, while Nongpaik, Jinheung and Hayayuki indicated considerable number of indehisced anther at 5 days after heading. 2. The fertility were not generally higher in cooling treatment at heading stage than at meiotic stage treatment. And significant correlation was found between the percentage of grain fertility treated at above two stages. Nongpaik and Jinheung were not affected in percentage of fertility by 5 day treatment at 15$^{\circ}C$ when these were treated at heading stage. Indehisced anthers were not found in Suwon 213-1 and Hayayuki, but Nongpaik and Jinheung showed more anthers which did not show anthesis 3. There was different varietal response to low temperature which was indicated by the decrease of grain fertility resulted from cooling treatment at meiotic stage. Jaekeun and Jinheung did not show low fertility but Milseong, Suwon 210, Satominoli and Suwon 213-1 showed outstanding decrease in fertility percentage by the cooling treatment at meiotic stage. The varieties which had low fertility were likely to have low pollen density per anther, abnormal anthers, small size po]]en grains and many sterile pollens. 4. Remarkable varietal difference of cold resistance was found in heading stage cooling treatment. Nongpaik, Jinheung, Jaekeun, Paltal, Akibare, Milseung and Palkeong were not affected in grain fertility by cooling treatments but Nonglimna No. 1, Suseong, Hayayuki, Suwon 213-1 and Suwon 210 showed significantly high sterility as treated by cool temperature. Most of the varieties showed higher fertility by cooling treatment at heading stage than meiotic stage but Hayayuki, Suseong and Nonglimna No.1 showed lower fertility when these were treated at heading stage than meiotic stage. There were two grops of varieties in the response to cooling treatment, one was somewhat non-anthesised and the other showed full anthesis. 5. In cold injury test of young seedlings, the result of observation was not accorded with the degree of growth inhibition. As a general, Palkeum and Suseong were highly torelant to cool temperature but Suwon 213-1, Jaekeun, Paltal, Shirogane, Palkeong, Mankyung were highly susceptible. 6. There is no significant correlation between the degree of young seedling cold damage and or the degree of growth retardation at seedling stage and grain fertility resulted from coding treatment both heading and meiotic stage.

  • PDF

Studies on the Performance Variation of a Variable Speed Vapor Compression System under Fault and Its Detection and Diagnosis (가변속 증기압축 냉동시스템에서 고장시의 성능변화와 고장 감지 및 진단에 관한 연구)

  • Kim Minsung;Kim Min Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.47-55
    • /
    • 2005
  • An experimental study has been peformed to develop a scheme for fault detection and diagnosis(FDD) in a vapor compression refrigeration system. This study is to analyze fault effect on the system performance and to find efficient diagnosis rules for easy determination of abnormal system operation. The refrigeration system was operated with a variable speed compressor to modulate cooling capacity. The FDD system was designed to consider transient load conditions. Four major faults were considered, and each fault was detected over wide operating load range by separating the system response to the load change. Rule-based method was used to diagnose and classify the system faults. From the experimental results, COP degradation due to the faults in a variable speed system is severer than that in a constant speed system. The method developed in this study can be used in the fault detection of refrigeration systems with a variable speed compressor.

Nuclear reactor vessel water level prediction during severe accidents using deep neural networks

  • Koo, Young Do;An, Ye Ji;Kim, Chang-Hwoi;Na, Man Gyun
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.723-730
    • /
    • 2019
  • Acquiring instrumentation signals generated from nuclear power plants (NPPs) is essential to maintain nuclear reactor integrity or to mitigate an abnormal state under normal operating conditions or severe accident circumstances. However, various safety-critical instrumentation signals from NPPs cannot be accurately measured on account of instrument degradation or failure under severe accident circumstances. Reactor vessel (RV) water level, which is an accident monitoring variable directly related to reactor cooling and prevention of core exposure, was predicted by applying a few signals to deep neural networks (DNNs) during severe accidents in NPPs. Signal data were obtained by simulating the postulated loss-of-coolant accidents at hot- and cold-legs, and steam generator tube rupture using modular accident analysis program code as actual NPP accidents rarely happen. To optimize the DNN model for RV water level prediction, a genetic algorithm was used to select the numbers of hidden layers and nodes. The proposed DNN model had a small root mean square error for RV water level prediction, and performed better than the cascaded fuzzy neural network model of the previous study. Consequently, the DNN model is considered to perform well enough to provide supporting information on the RV water level to operators.

The Clinical Summary of the Coronary Bypass Surgery (심장 관상동맥 외과)

  • 정황규
    • Journal of Chest Surgery
    • /
    • v.13 no.3
    • /
    • pp.174-185
    • /
    • 1980
  • It was my great nohour that I can be exposed to such plenty materials of the coronary bypass surgery. Here, I am summarizing the xoronary bypass surgery, clinically. The material is serial 101 patients who underwent coronary bypass surgery between July 17, 1979 to November 30, 1979 in Shadyside Hospital, University of Pittsburgh. 1. Incidence of the Atherosclerosis is frequent in white, male, fiftieth who are living in industrialized country. It has been told the etiologic factor of the atherosclerosis is hereditary, hyperlipidemia, hypertension, smoking, drinking, diabetes, obesity, stress, etc. 2. The main and most frequent complication of the coronary atherosclerosis is angina pectoris. Angina pectoris is the chief cause of coronary bypass surgery and the other causes of coronary bypass surgery are obstruction of the left main coronary artery, unstable angina, papillary muscle disruption or malfunction and ventricular aneurysm complicated by coronary artery disease. 3. The preoperative clinical laboratory examination shows abnormal elevation of plasma lipid in 82 patint, plasma glucose in 40 patient, total CPK-MB in 24 patient stotal LDH in 22 patient out of 101 patient. 4. Abnormal ECG findings in preoperative examine were 29.1% myocardial infarction, 25.8% ischemia and injury, 14.6T conduction defect. 5. Also we had done Echocardiography, Tread Mill Test, Myocardial Scanning, Vectorcardiography and Lung function test to get adjunctive benefit in prediction of prognosis and accurate diagnosis. 6. The frequency of coronary atherosclerosis in main coronary arteries were LAD, RCA and Circumflex in that order. 7. The patients' main complaints which were became as etiologic factor undergoing coronary bypass surgery were angina, dyspnea, diaphoresis, dizziness, nausea and etc. 8. For the coronary bypass surgery, we used cardiopulmonary bypass machine, non-blood, diluting prime, cold cardioplegic solution and moderate cooling for the myocardial protection. 9. We got the grafted veins from Saphenous and Cephalic vein. Reversed and anastomosed between aorta and distal coronary A. using 5-0 and 7-0 prolene continuous suture. Occasionally we used internal mammary A. as an arterial blood source and anastomosed to the distal coronary A. and to side fashion. 10. The average cardiopulmonary bypass time for every graft was 43.9 min. and aortic clamp time was 23 minute. We could Rt. coronary A. bypass surgery only by stand by the cardiopulmonary machine and in the state of pumping heart. 11. Rates by the noumbers of graft were as follow : 21.8% single, 33.7% double, 26.7% triple, 13.9% quadruple, 3% quintuple and 1% was sixtuple graft. 12. combined procedures with coronary bypass surgery were 6% aneurysmectomy, 3% AVR, 1% MVR, 13% pacer implantation and 1% intraaortic ballon setting. 13. We could see the complete abolition of anginal pain after operation in 68% of patient, improvement 25.8%, no change in 3.1%, and there was unknown in 3%. 14. There were 4% immediate postoperative deaths, 13.5% some kinds of heart complication, 51.3% lung complications 33.3% pleural complications as prognosis.

  • PDF

Clinical Study on 1 Case of Soyangyin Patient Diagnosed as Crohn's Disease (크론씨병으로 진단된 소양인 환자 치험 1 례)

  • Lee, Seung-Hyun;Park, Darn-Seo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.5
    • /
    • pp.1346-1351
    • /
    • 2007
  • Crohn' disease is an auto-immune disease characterized by intermittent chronic diarrhea, high fever, weight loss, abdominal spastic pain or abdominal discomfort which is followed by granulomatous necrosis and cicatrical inflammation. It is also called segmental enteritis or granulomatous enteritis. In western medicine the exact cause is undefined, however it is presumed as an immunological unbalance in alimentary tract commoonly occured in ileum portion of small intestitine or ascending colon and therefore immuno suppressive agents(usually steroids) and anti-inflammatory drugs are prescribed. In case of emergency such as ileus, perforation of intestinal wall surgical methods are considered. In oriental medicine this falls under the category of diarrhea(泄瀉), dysentery(痢疾), splenic diarrhea(脾泄). As to the pathological mechanism the abnormal ascending and descending circulation of stomach and splenic energy(脾不升淸, 胃不下降) the hepatic stagnation(肝鬱氣滯) and dysfunction of small intestine in expelling urine and feces(小陽淸獨不利) all together causes such condition. Main treatments are inducing diuresis(利小便), warming kindey to reinforce yang(溫賢助陽), nourishing the middle energy to invigorate spleen(補中健脾), elimination of the dampness by cooling(淸熱燥濕). In this case the patient was diagnosed as soyangyin(少陽人) constitution and herb medicine soyangyin Hyongbangjihwan-tang(少陽人 荊防地黃湯), Sa-am acupuncture Sojangjeonggyeok(小腸政格) was applied. There was an significant improve in chief complaints and general conditions.

Numerical Study on the Thermal Environment of a Natural Light Based Multi-layered Plant Factory (자연광 기반 적층형 식물공장의 열환경에 대한 수치해석 연구)

  • Park, Dong Yoon;Jang, Seong-Teak;Chang, Seong-Ju
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.43-50
    • /
    • 2013
  • Recent researches on plant factory system deal with the convergence of lighting technology, agricultural technology inclusive to the high-tech industries worldwide in order to respond to the decreasing crop harvest due to global warming and abnormal weather phenomena. However, the fundamental performance standard is not currently being introduced in the case of plants factory and its commercialization is not activated because of high initial investment and operating cost. Large portion of the initial investment and operating cost of a plant factory is ascribed to artificial light sources and thermal control facilities, therefore, innovation should be provided in order to improve the economics of the plant factory. As an alternative, new plant factory could harness solar thermal and geothermal systems for heating, cooling and ventilation. In this study, a natural light dependent multi-layer plant factory's thermal environment was analyzed with two-dimensional numerical methods to elicit efficient operation conditions for optimized internal physical environment. Depending on the supply air temperature and airflow rate introduced in the facility, the temperature changes around the crops was interpreted. Since the air supplied into the plant factory does not stay long enough, the ambient temperature predicted around the plating trays was not significantly different from that of the supplied air. However, the changes of airflow rate and air flow pattern could cause difference to the temperature around the planting trays. Increasing the amount of time of air staying around the planting trays could improve energy performance in case the thermal environment of a natural light based multi-layer plant factory is considered.

The Criticality Analysis of Spent Fuel Pool with Consolidated Fuel in KNU 9 & 10 (조밀화 집합체로 중간저장하는 경우 원자력 발전소 9, 10호기의 사용 후 핵연료 저장조의 임계분석)

  • Jae, Moo-Sung;Park, Goon-Cherl;Chung, Chang-Hyun;Jang, Jong-Hwa
    • Nuclear Engineering and Technology
    • /
    • v.20 no.1
    • /
    • pp.27-34
    • /
    • 1988
  • Since the lack of the spent fuel storage capcity has been expected for all Korean nuclear power plants in the mid-1990s, the maximum density rack (MDR) with consolidated fuels can be proposed to overcome the shortage of the storage capacity in KNU 9 & 10 which have most limited capacities. To ensure the safety when the alternatives are applied in the KNU 9 & 10, the multiplication factor are calculated with varying the rack pitch and the thickness of consolidated storage box by the AMPX-KENO IV codes. The computing system is verified by the benchmark calculation with criticality experiments for arrays of consolidated fuel modules, which was reported by B & W in 1981. Also an abnormal condition, i.e. malposition accident, is simulated. The results indicate that the KNU 9 & 10 storage pools with consolidated fuel are safe in the view of the criticality. Thus the storage capacity can be expanded from 9/3 cores into 27/3 cores even with considering equipments and cooling spaces.

  • PDF