• Title/Summary/Keyword: Abnormal cooling

Search Result 39, Processing Time 0.028 seconds

Abnormal Cooling before and after the 1982-1983 and 1997-1998 ENSO Events in the Korean East Sea Water (1982-1983년.1997-1998년 엘니뇨현상 전후 한국동해역에서의 이상 저수온 현상)

  • Hong, Chul-Hoon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.41 no.4
    • /
    • pp.294-300
    • /
    • 2008
  • Abnormal cooling of the Korean East Sea Water(KESW) in the East Sea before and after the 1982-1983 and 1997-1998 ENSO events is examined using bimonthly routine observation data from the National Fisheries Research and Development Institute of Korea for the period 1965 to 2002. The KESW, which occupies roughly a region between the Korean Peninsula and west of approximately $131^{\circ}E$, showed extreme cold-state years(1981 and 1996) prior to the two strongest ENSO events of the last half-century. Inter-annual bimonthly mean anomalies at 100 m in the KESW region were $-3.10^{\circ}C\;and\;-3.41^{\circ}C(SD=1.4^{\circ}C)$ in 1981 and 1996, respectively. These results suggest that extreme cooling of the KESW may be a prelude to very strong ENSO events through large-scale teleconnections.

Predictive factors of death in neonates with hypoxic-ischemic encephalopathy receiving selective head cooling

  • Basiri, Behnaz;Sabzehei, Mohammadkazem;Sabahi, Mohammadmahdi
    • Clinical and Experimental Pediatrics
    • /
    • v.64 no.4
    • /
    • pp.180-187
    • /
    • 2021
  • Background: Severe perinatal asphyxia results in multiple organ involvement, neonate hospitalization, and eventual death. Purpose: This study aimed to investigate the predictive factors of death in newborns with hypoxic-ischemic encephalopathy (HIE) receiving selective head cooling. Methods: This cross-sectional descriptive-retrospective study was conducted from 2013 to 2018 in Fatemieh Hospital of Hamadan and included 51 newborns who were admitted to the neonatal intensive care unit with a diagnosis of HIE. Selective head cooling for patients with moderate to severe HIE began within 6 hours of birth and continued for 72 hours. The required data for the predictive factors of death were extracted from the patients' medical files, recorded on a premade form, and analyzed using SPSS ver. 16. Results: Of the 51 neonates with moderate to severe HIE who were treated with selective head cooling, 16 (31%) died. There were significant relationships between death and the need for advanced neonatal resuscitation (P=0.002), need for mechanical ventilation (P=0.016), 1-minute Apgar score (P=0.040), and severely abnormal amplitude-integrated electroencephalography (a-EEG) (P=0.047). Multiple regression of variables or data showed that the need for advanced neonatal resuscitation was an independent predictive factor of death (P=0.0075) and severely abnormal a-EEG was an independent predictive factor of asphyxia severity (P=0.0001). Conclusion: All cases of neonatal death in our study were severe HIE (stage 3). Advanced neonatal resuscitation was an independent predictor of death, while a severely abnormal a-EEG was an independent predictor of asphyxia severity in infants with HIE.

On the Abnormal Cooling Phenomenon in the Coastal Areas of East Sea of Korea in Summer,1981 (1981年 夏季 東海沿岸域의 異常底水溫現象)

  • Hong, Chol-Hoon;Cho, Kyu-Dae;Yang, Sung-Ki
    • 한국해양학회지
    • /
    • v.19 no.1
    • /
    • pp.11-17
    • /
    • 1984
  • The abnormal cooling phenomenon occurred in the coastal areas of East Sea of Korea in summer, 1981 is studied on the basis of the oceanographical data obtained by the National Fisheries University of Pusan, in July, 1981 and by Fisheries Research and Development Agency of Korea during 1961 to 1981 and by Japan Meteorological Agency in 1975 and 1981. Th vertical section of temperature along 130 E showed that the warmer waters more than 10 C occupied at upper layer of about 75m depth in south of 35 30'N the layer changed rapidly thinner as 20m th 30m depth. In the areas of East Sea during 1966 to 1981, the temperature fluctuations at 100m depth ranged greatly in standard deviation from 2 C to 4 C. The temperature anomaly in 1981 was about 1.5 times of the standard deviation and at the upper layer of 150m depth the temperatures became colder by 5 -10 C than average values in August, 1961-1975. The 10 C isotherm at 100m depth in 1981 appeared between 35 and 36 N, shifting southward 20 to 120 miles than mean year. These results showed that the abnormal cooling phenomenon in the areas of East Sea of Korea in summer occurred mose predominantly in 1981 in period from 1966 to 1981

  • PDF

5% Rule Disclosure and Stock Trading Volume : Evidence from Korea

  • KIM, Eung-Gil;KIM, Sook-Min
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.6 no.4
    • /
    • pp.297-307
    • /
    • 2019
  • Despite the fact that the implementation of 5% rule is widely recognized to enhance the transparency of capital market and fairness of corporate governance market, a few evidences present information effect of 5% rule. Using 7,088 non-financial firm-year observations listed on the Korea Stock Exchange from 2006 to 2012, we analyze the relation between trading volume and 5% rule disclosure. The results show that the daily and abnormal trading volume is increased when 5% rule disclosure is released. Moreover, the trading volume is significantly increased during cooling period. Specifically, trading volume is significantly greater when one day before cooling period or the expiration day of cooling period. We also find the information effect of firms with stable ownership structure before 5% rule disclosure is relatively smaller than the firms with unstable ownership structure with unstable ownership structure. These results imply that capital market participants use the information from 5% rule disclosure and reflect in their real economic decision.

Containment Closure Time Following Loss of Cooling Under Shutdown Conditions of YGN Units 3&4

  • Seul, Kwang-Won;Bang, Toung-Seok;Kim, Se-Won;Kim, Hho-Jung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.647-652
    • /
    • 1998
  • The YGN Units 3&4 plant conditions during shutdown operation were reviewed to identified the possible even scenarios following the loss of shutdown cooling. The Thermal hydraulic analyses were performed for the five cases of RCS configurations under the worst event scenario, unavailable secondary cooling and no RCS inventory makeup, using the RELAP5/MOD3.2 code to investigate the plant behavior, From the analyses results, times to boil, times to core uncovery and times to core heat up were estimated to determined the containment closure time to prevent the uncontrolled released of fission products to atmosphere, These data provide useful information to the abnormal procedure to cope with event.

  • PDF

A Study on Economic Analysis of Natural Gas Cooling (천연가스냉방의 경제성 분석 연구)

  • Kim, Ki-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.1
    • /
    • pp.42-48
    • /
    • 2013
  • The global warming of the Korean Peninsula proceeds most rapidly in the world and its abnormal climate is more deepening. In the result of the surged electricity consumption by intense heat of summer and severe cold of winter, electricity supply and demand status is in hard situation. Currently, the supply of natural gas is increased because natural gas has the lowest greenhouse-gas emissions among the existed fossil fuel. Natural gas cooling has a lot of advantage such as decreasing electricity peak, reducing construction expenses in additional power plant, operating natural gas storage facilities efficiently, and playing a role as distributed generations. Therefore, this study analyzes the economic feasibilities of gas cooling as an alternative for electric power load management.

Dependence of Microstructure of Sintered $Y_3$Fe$_5$O$_{12}$ in Addition of CuO (CuO 첨가에 따른 $Y_3$Fe$_5$O$_{12}$ 소결체의 미세구조 변화)

  • 이재동;김광석;김성재;김태옥
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.10
    • /
    • pp.1014-1019
    • /
    • 1998
  • As results of the study on the sinterbility of YIG at the low temperature using CuO as additive CuO com-pound which contain {{{{ { {Fe }_{2 }O }_{3 } }} was shown liquid in sintering process. YIG crystal dissolved into CuO compound liquid phase and then Y element which is considered no solubility in solid CuO compound moved to the grain during cooling. The abnormal grain growth up to 150${\mu}{\textrm}{m}$ at CuO 8.6mole% was shown due to shape accomdation reaction and local liquid distribution. The apparent density of YIG shows minimum at CuO 8.6 mole% due to abnormal grain growth and the saturation magnetization decrease dramatically at 32.5mole% due to orthoferrite formation.

  • PDF

An Optimal Design of a Vertical Guide Bearing for Vibration Reduction (축계 진동 저감을 위한 수직형 안내 베어링의 최적 설계)

  • Ha, Hyun-Cheon;Park, Chul-Hyun;Kim, Hyung-Ja
    • Journal of Power System Engineering
    • /
    • v.5 no.3
    • /
    • pp.64-72
    • /
    • 2001
  • This paper describes an optimal design technology in a segment type vertical guide bearing for vertical rotating machinery. Segment type vertical guide bearings have widely used for vertical rotating machinery, however bearing problems, such as excessive vibration and temperature rise, frequently take place in the actual machine. Such excessive vibration magnitude and/or abnormal bearing metal temperature rise result in serious damage and economic losses. Thus the segment type vertical guide bearing should be designed to get optimal characteristics in order to maintain stable operation without bearing failure due to abnormal vibration and/or abnormal bearing metal temperature. The preload ratio is the most important parameter in designing the segment type vertical guide bearing. Because adjustment of the bearing preload by changing the bearing clearance could easily control both the bearing stiffness and the cooling effect. In the paper, the influence of the preload effects on the bearing metal temperature and the bearing stiffness has been investigated both theoretically and experimentally in order to find out an optimum preload ratio. Results show that the segment type vertical guide bearing has an optimum preload ratio at which the bearing stiffness reaches a masimum value while the bearing metal temperature is minimized.

  • PDF

Abnormal Oceanic Conditions Caused by Typhoons Around the Korean Peninsula (태풍에 의해 발생하는 한국근해 해황이상변동)

  • SUH Young-Sang;GU Ji-Young;HWANG Jae-Dong;LEE Na-Kyung;KIM Bok-Kee;JANG Lee-Hyun;KANG Yong-Q;LEE Dong-In
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.4
    • /
    • pp.417-429
    • /
    • 2003
  • Abnormal oceanic conditions associated with the passage of typhoons are examined using hydrographic and satellite data 1990-2002. During the passage period of typhoons in the Korean waters, an abrupt decrease of sea surface temperature (SST) in range of 5 to $8^{\circ}C$ was observed. The areas of SST decrease were an order of 100-200 km, and the low SST lasted about 15-25 days after passage of typhoon. After passage of typhoon, the water temperatures in the surface mixed layer of 30 m show negative anomalies for quite a long period. In addition, stratification parameters were substantially decreased and chlorophyll a density was rapidly increased.