• Title/Summary/Keyword: Abnormal Behavior

Search Result 554, Processing Time 0.034 seconds

A Study on the High School Teachers' Sexual Knowledge, Attitude and Their Need of Sex Education for the Students (서울시내(市內) 고등학교(高等學校) 교사의 성지식(性知識), 태도(態度) 및 학생에 대한 성교육(性敎育) 요구(要求) 조사(調査))

  • Kim, Cha Young
    • Journal of the Korean Society of School Health
    • /
    • v.3 no.1
    • /
    • pp.19-47
    • /
    • 1990
  • The purpose of this study was to investigate the high school teachers' sexual knowledge, attitude and their need of sex education for the students in Seoul. These data were collected by questionnaire in Oct. 1989. The result was compared by the type of teacher (school health nurse and high school teacher), involving in sex education or not, age, marital status and religion. The major findings of this study were as follows: 1. The mean score of sexual knowledge of the school health nurses was higher than the high school teachers. (P<0.05) (the average correct answer rate:the school health nurses=80.85%, the high school teachers=62.65%)Female teachers who were involved in sex education got higher score than the male high school teachers and female teachers who were not. (P<0.05) The married female high school teachers got higher score than never-married. (p<0.05) 2. About the sexual attitudes, the respondents were asked in the Likert's four-point scale with 3 groups of questions that were anatomical and physiological terminology about sex, normal sexual life and immoral sexual life. About anatomical and physiological terminology about sex, they had a little positive feeling. (mean score= 2.62) The school health nurses and the male high school teachers had more positive feeling than the female. (P< 0.05) Also the aged and married male high school teachers had more positive feeling than others. (P<0.05) About normal sexual life, they had a little positive feeling and moderately permissive attitude. (feeling mean score=2.96, attitude mean score=3.23) The school health nurses and the male high school teachers had more positive feeling than the female. (P<0.05) And the male high school teachers had more permissive attitude than the female. (P<0.05) About immoral sexual life, they had strongly negative feeling and conservative attitude. (feeling mean score =3.49, attitude mean score=3.35) The school health nurses the female high school teachers had more negative feeling and conservative attitude than the male. (P<0.05) And the male protestant high school teachers had more conservative attitude than no-religion group. (P<0.05) 3. There was a weak correlation between sexual knowledge and attitude. 4. There was no significant difference about starting of sex education between the school health nurses and the high school teachers. (P>0.05) Generally, they answered that the starting of sex education about physical growth and development could bp given with the students' physical growth and development. But for the sex education about emotional and social development, they answered that the education should be given later than the emotional and social development of students. 62.1% of the school health nurses did sex education and 36.5% of the high school teachers did. The common contents of sex education were intersexual-fellowship(date), venereal disease and marriage. And the education about abnormal sex-behavior. divorce and sexual intercourse was given rarely.

  • PDF

Design of a Voltage Protection Circuit for DC-DC Converter of the Potable Device Application (소형 휴대기기용 DC-DC 변환기를 위한 전압 보호회로 설계)

  • Park, Ho-Jong;Heo, Yun-Seok;Park, Yong-Su;Kim, Nam-Tae;Song, Han-Jung
    • 전자공학회논문지 IE
    • /
    • v.49 no.1
    • /
    • pp.18-23
    • /
    • 2012
  • In this paper, a potable device application for DC-DC converter was designed for voltage protection circuit. Voltage protection circuit to offer the under voltage lock out and over voltage protection consists of a comparator and bais circuits were implemented using. XFAB 1um CMOS process, SPICE simulations was confirmed through the characteristics. Simulation results, under voltage lock out input voltage is 4.8 V higher when the turn-on and, 4.2 V less when turn-off. When the input voltage is low voltage is applied can be used to prevent malfunction of the circuit. Over voltage protection is 3.8 V reference voltage when the output voltage caused by blocking circuit prevents device destruction can be used to improve the stability and reliability. The virtual control circuits of the DC-DC converter connected. According to the results of the abnormal voltage, voltage protection circuit behavior was confirmed. The proposed voltage protection circuit of the DC-DC converter cell is useful are considered.

Design of Network Attack Detection and Response Scheme based on Artificial Immune System in WDM Networks (WDM 망에서 인공면역체계 기반의 네트워크 공격 탐지 제어 모델 및 대응 기법 설계)

  • Yoo, Kyung-Min;Yang, Won-Hyuk;Kim, Young-Chon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.4B
    • /
    • pp.566-575
    • /
    • 2010
  • In recent, artificial immune system has become an important research direction in the anomaly detection of networks. The conventional artificial immune systems are usually based on the negative selection that is one of the computational models of self/nonself discrimination. A main problem with self and non-self discrimination is the determination of the frontier between self and non-self. It causes false positive and false negative which are wrong detections. Therefore, additional functions are needed in order to detect potential anomaly while identifying abnormal behavior from analogous symptoms. In this paper, we design novel network attack detection and response schemes based on artificial immune system, and evaluate the performance of the proposed schemes. We firstly generate detector set and design detection and response modules through adopting the interaction between dendritic cells and T-cells. With the sequence of buffer occupancy, a set of detectors is generated by negative selection. The detection module detects the network anomaly with a set of detectors and generates alarm signal to the response module. In order to reduce wrong detections, we also utilize the fuzzy number theory that infers the degree of threat. The degree of threat is calculated by monitoring the number of alarm signals and the intensity of alarm occurrence. The response module sends the control signal to attackers to limit the attack traffic.

Optical Fiber-Based Hybrid Nerve Measurement System for Static and Dynamic Behavior of Structures (구조물의 정적 및 동적 거동 모니터링을 위한 광섬유 기반 하이브리드 신경망 계측 시스템)

  • Park, Young-Soo;Song, Kwang-Yong;Jin, Seung-Seop;Park, Young-Hwan;Kim, Sung-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.33-40
    • /
    • 2020
  • Various studies have been conducted on the structural health monitoring using optical fiber. Optical fibers can be used to measure multiple and distributed strain. Among the optical fiber sensors, FBG sensor has advantages of dynamic response measurement and high precision, but the number of measurement points is limited. Distributed fiber sensors, represented by distributed Brillouin sensors, usually have more than 1000 measurement points, but the low sampling rate makes dynamic measurements impossible. In this study, a hybrid nerve sensor system using only the advantages of the FBG sensor and the distributed Brillouin sensor has been proposed. Laboratory experiments were performed to verify the proposed system, and the accuracy and reproducibility were verified by comparing with commercial sensors. Applying the proposed system, dynamic response ambient measurements are used to evaluate the global state of the structure. When an abnormal condition is detected, the local condition of the structure is evaluated by static response measurement using the distributed measurement system. The proposed system can be used for efficient structural health monitoring.

Brain wave results in children with attention deficit hyperactivity disorder and treatment result with central nervous system stimulants (주의력결핍 과잉행동장애 환아에서 시행한 뇌파 결과 및 중추신경자극제 치료에 따른 결과)

  • Lim, Young Su;Sim, Ji Yun;Son, Jung-Woo;Kim, Won Seop
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.12
    • /
    • pp.1324-1328
    • /
    • 2008
  • Purpose : Attention deficit hyperactivity disorder (ADHD) is a syndrome characterized by inattention, impulsive disruptive behavior, impaired concentration, and motor restlessness. This study examined the relationships among electroencephalographic (EEG) findings, stimulant use, and seizure occurrence in children with ADHD. Methods : We retrospectively studied 308 children with ADHD who visited the neuropsychiatric clinic of our hospital from January 2001 to December 2005. We retrospectively analyzed age distribution, etiology, abnormal EEG findings, and use of CNS stimulants. Among these children, brain waves was recorded in 84 patients. Results : Eighty-four children (72 males, 85.7%, 9.3 years mean age; 12 females, 14.3%, 8.0 years mean age) with ADHD had electroencephalograms (EEGs) performed at our institute. Nineteen patients (22.6%) demonstrated epileptiform abnormalities, and 65 (77.4%) demonstrated normal EEGs. Stimulant therapy was applied to 59 of 84 patients (70.2%). Seizures occurred in 1 of 65 patients with a normal EEG (incidence, 1.5%) and 3 of 19 treated patients with epileptiform EEGs (incidence, 15.7%). Conclusion : These data suggest that patients with normal EEGs have minor risk for seizure. In contrast, patients with epileptiform EEGs have higher risk for seizure than patients with normal EEGs.

The Study of Permeation Characteristics for Pure Carbon Dioxide and Methane, and Gas Mixture in Cellulosic Membrane (셀룰로오스 분리막을 통한 순수 이산화탄소 메탄 및 혼합기체의 투과 특성 연구)

  • Kim, Hyun Joon;Kim, Hong Il;Kang, Yong Soo;Hong, Suk In
    • Applied Chemistry for Engineering
    • /
    • v.7 no.4
    • /
    • pp.605-613
    • /
    • 1996
  • The permeation characteristics were investigated for pure carbon dioxide and methane through asymmetric cellulose acetate(CA) membrane, composite cellulose acetate membrane and asymmetric cellulose triacetate(CTA) membrane. In particular, the effect of operating pressure on the permeation performance was examined. And the permeation behavior for a mixture of carbon dioxide and methane ($CO_2/CH_4=57.6/42.4$) was also investigated and compared to the characteristics obtained from pure gases. The experiments were run at the range of partial pressure from 25 to 125 psig, and room temperature. The permeation behaviors of the CA composite and CTA membrane were similiar to those of the CA membrane. The permeation rates of pure carbon dioxide for CA, CA composite and CTA membrane were increased slightly with an increase in upstream partial pressure, while in the case of pure methane they were independent of upstream partial pressure. For a binary mixture of carbon dioxide and methane, abnormal permeation behaviors were observed due to the plasticization of carbon dioxide and the competition effect of each gas. The separation factor and permeation rate for CTA membrane were found to be higher than those for CA membrane, but the mechanical strength of CTA membrane was very poor. And the permeation rate for CA composite membrane was higher than that for CA membrane. Consequently, it can be said that the CA composite membrane is a strong candidate for the separation of $CH_4$ and $CO_2$.

  • PDF

A Comparative Effect of Meperidine between Intravenous and Epidural Patient-Controlled Analgesia for the Postoperative Pain Relief after Cesarean Section (제왕절개 수술후 통증조절을 위해 PCA를 이용한 정맥과 경막외 Meperidine 투여효과의 비교)

  • Lee, Byung-Ho;Chea, Jun-Seuk;Chung, Mee-Young;Byun, Hyung-Jin
    • The Korean Journal of Pain
    • /
    • v.8 no.2
    • /
    • pp.257-265
    • /
    • 1995
  • Patient-Controlled Analgesia (PCA) has been widely used for postoperative pain relief. Meperidine is useful for PCA and has efficient analgesia, rapid onset, and low incidence of adverse effect. To compare the analgesic effect, total dose and hourly dose, side effect and neonatal status of breast feeding with meperidine via intravenous or epidural PCA for 48 hours after Cesarean Section, 40 parturient women undergoing elective Cesarean Section were randomly divided into two groups. Each respective group of 20 parturient women received meperidine via one of the intravenous PCA after general anesthesia with enflurane (IVPCA group) and the epidural PCA after general anesthesia with enflurane (IVPCA group) and the epidural PCA after epidural block with 2% lidocaine 20ml combined with general anesthesia with only $N_2O$ and $O_2$ (EpiPCA group) when they first complained of pain in recovery room. Following the administration of analgesic initial dose, parturient women of IVPCA group were allowed intravenous meperidine 10 mg every 8 minutes when they felt pain. The EpiPCA group received additional bolus dose of meperidine 2 mg and bupivacaine 0.7 mg were administered every 8 minutes as requested the patients with hourly continuous infusion of meperidine 4 mg and bupivacaine 1.4 mg. Data was collected during the 48 hours observation period including visual analog scale (VAS) pain scores, total meperidine dose, hourly dose during 48 hours and each time interval, incidence of adverse effect, satisfaction, and neonatal status with breast feeding. VAS pain scores of analgesic effect in EpiPCA group was significantly lower than in IVPCA group at 2 hours after the initial pain after Cesarean Section. Total dose and hourly dose of meperidine significantly reduced in EpiPCA group. Hourly dose of meperidine at each time interval significantly reduced during first 6 hours and from 12 hours to 24 hours in EpiPCA group. The side effects in IVPCA group were mainly sedation, nausea, and local irritation of skin. And EpiPCA group experienced numbness and itching. The degree of satisfaction of parturient women was 88.2 % in IVPCA group and 85.7 % in EpiPCA group. We did not observe any sedation, abnormal behavior, or seizure like activity in any neonates of breast feeding. From the above results we conclude that epidural PCA was more efficiently analgesic, less sedative, and consumptional, and safer for neonate than intravenous PCA, and could be an alternative method to intravenous PCA.

  • PDF

A Study on the Phobia Treatment Using 3D Virtual Reality System (3D 가상환경시스템 이용한 공포증 치료에 대한 연구)

  • Paek Seung-Eun
    • The Journal of Information Technology
    • /
    • v.5 no.4
    • /
    • pp.45-55
    • /
    • 2002
  • Virtual Reality(VR) is a new technology which makes humans communicate with computer. It allows the user to see, hear, feel and interact in a three-dimensional virtual world created graphically. In this paper, we introduced VR into psychotherapy area and developed VR system for the exposure therapy of acrophobia. Acrophobia is an abnormal fear of heights. Medications or cognitive-behavior methods have been mainly used as a treatment. Lately the virtual reality technology has been applied to that kind of anxiety disorders. A virtual environment provides patient with stimuli which arouses phobia, and exposing to that environment makes him having ability to over come the fear. In this study, the elevator stimulator that composed with a position sensor, head mount display, and audio system, is suggested. To illustrate the physiological difference between a person who has a feel of phobia and without phobia, heart rate was measured during experiment. And also measured a person's HR after the virtual reality training. In this study, we demonstrated the subjective effectiveness of virtual reality psychotherapy through the clinical experiment.

  • PDF

Behavioral Contextualization for Extracting Occupant's ADL Patterns in Smart-home Environment (스마트 홈 환경에서의 재실자 일상생활 활동 패턴 추출을 위한 행동 컨텍스트화 프로세스에 관한 연구)

  • Lee, Bogyeong;Lee, Hyun-Soo;Park, Moonseo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.1
    • /
    • pp.21-31
    • /
    • 2018
  • The rapid increase of the elderly living alone is a critical issue in worldwide as it leads to a rapid increase of a social support costs (e.g., medical expenses) for the elderly. In early stages of dementia, the activities of daily living (ADL) including self-care tasks can be affected by abnormal patterns or behaviors and used as an evidence for the early diagnosis. However, extracting activities using non-intrusive approach is still quite challenging and the existing methods are not fully visualized to understand the behavior pattern or routine. To address these issues, this research suggests a model to extract the activities from coarse-grained data (spatio-temporal data log) and visualize the behavioral context information. Our approach shows the process of extracting and visualizing the subject's spaceactivity map presenting the context of each activity (time, room, duration, sequence, frequency). This research contributes to show a possibility of detecting subject's activities and behavioral patterns using coarse-grained data (limited to spatio-temporal information) with little infringement of personal privacy.

Electrochemical Behavior of Dissolved Hydrogen and Hydrogen Peroxide in Boric Acid Solution at the Elevated Temperature (붕산수용액 매질에서 용존수소와 과산화수소의 고온 전기화학 거동연구)

  • Yeon Jei-Won;Woo Seung-Kyun;Choi Young-Ku;Jung Yongju;Kim Won-Ho
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.1
    • /
    • pp.21-25
    • /
    • 2004
  • The electrochemical behaviors of dissolved hydrogen and hydrogen peroxide at a platinum disk electrode were investigated in boric acid solution by potentiostatic polarization method at the temperature of 25 and $200^{\circ}C$. The oxidation of dissolved hydrogen at $25^{\circ}C$ was kinetically controlled reaction, the rate of which depends upon the electron transfer on the electrode surface. As temperature was raised, however, the electrochemical characteristics of dissolved hydrogen were changed from a kinetically controlled reaction to a diffusion controlled one. One notable feature, with dissolved hydrogen at high temperature, is that an abnormal potential range was observed, where the oxidation rate of dissolved hydrogen rapidly decreased just before starting potential of water oxidation. We think it is caused by the deactivation of the electrode that results from the adsorption of hydroxyl ion on the surface of the platinum disk. On the contrary, a definite change with temperature was not identified in the case of the hydrogen peroxide except for the increase in current density that was due to the increasing diffusion coefcient with an increase of temperature.