• Title/Summary/Keyword: Abdomen CT

Search Result 201, Processing Time 0.024 seconds

Assessment of DRL for Computed Tomography in Local Hospital (지역병원에서의 전산화단층촬영 검사에 대한 DRL 평가)

  • Choi, Seok-Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.619-625
    • /
    • 2022
  • In the field of imaging medicine, computed tomography is one of the most common test methods and one of the most frequently used test methods in hospitals. However, it is accompanied by a very high radiation exposure compared to other test methods. In order to reduce exposure, CT scans should be performed only when absolutely necessary, and even if the tests are performed because they are absolutely necessary, a protocol that serves the purpose of the test and allows the test to be performed in a small dose should be used. In this study, we wanted to learn about the most up-to-date radiation dose usage information used by the region's leading general hospitals and develop a diagnostic reference level (DRL). In the experimental results, the Head CT and Abdomen CT tests showed that DLP was higher than the NRPB (U.K) and Korean DRL. The DLP values used by Chest CT were low for all 3 types of CT devices. The hospital found that efforts to reduce exposure should be made during CT examinations, and in particular, Head CT and Abdomen CT determined that efforts to reduce exposure were necessary.

Radiation dose and Lifetime Attributable Risk of Cancer Estimates in 64-slice Multidetector Computed Tomography (64-절편 다행검출 CT 검사에서의 환자선량과 암 발생의 Lifetime Attributable Risk(LAR) 평가)

  • Kang, Yeong-Han;Park, Jong-Sam
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.244-252
    • /
    • 2011
  • This study was to estimate the radiation dose associated with 64-slice multidetector CT(MDCT) in clinical practice and quantify the potential cancer risk associated with these examinations. Lifetime attributable risks(LAR) were estimated with models developed in the national Academies' Biological Effects of Ionizing Radiation VII report. Mean effective dose were 1.48mSv in Brain axial scan, 7.66mSv in chest routine contrast, 12.17mSv in coronary angiogram, 24.52mSv in Dynamic abdomen scan. LAR estimates for brain routine varied from 1 in 7463 for man to 1 in 4926 for women. In chest routine with contrast, LAR varied from 1 in 1449 for men to 1 in 952. LAR of Abdomen dynamic CT varied from 1 in 453 for men to 1 in 298 for women. So, 64-slice MDCT scan is associated with non-negligible LAR of cancer. Doses can be reduced by careful attention to scanning protocol.

A Study on the Status and Utilization of Computed Tomography Units in Pusan Area (전산화(電算化) 단층촬영기(斷層撮影機)의 보유현황(保有現況) 및 이용실태(利用實態) (부산시내(釜山市內) 병원(病院)을 중심(中心)으로))

  • Oh, Moon-Young
    • Journal of radiological science and technology
    • /
    • v.14 no.1
    • /
    • pp.29-44
    • /
    • 1991
  • A Study on the distribution and types of the total 40 CT units, as of 1st October 1990, in Pusan area(29 for whole body CT units, 11 for brain CT units) were carried out during the period from January 1989 to December 1989 to find out the status of operation and utilization of whole body CT units. The results were as following ; 1. As of 1st October 1990 in Pusan area, a total of 40 CT units(29 for whole body CT units, 11 for brain CT units) were set up and operated. The number of cases of CT examination performed per day per unit were appeared to be less than 5 cases among 59.5% of CT units, and 2.7% of the total units has peformed more than 16 examinations. 2. The CT units under operation occupied 93.5% of the total and 2.6% of the total units was not properly been operated due to mechanical breakdown. This results is appeared to be better than other reports. 3. The average number of scanning per week for each CT were 35 cases and the average days under operation of the unit per week were 6.7 days. Consequently, the average days under operation of units was higher than that of the other reports, but the average number of scanning was lower. 4. The cases referred from other institutes to hospitals were 6.4% of total cases. 5. As a site of scanning, the brain appeared most frequently with 71.2% of the total cases and followed by spine 12.4%, abdomen 8.5%, and thorax 3.6%, respectively. 6. Positive rate by scanning was 70.8% of total cases, and it was 98.9% with thorax, abdomen 96.3%, spine 93.1%, and brain 38.4%, respectively. According to the results of this study, it is highly recommended that the regulations and the guidelines for setting-up of such high cost medical equipments as CT units be provided in order to ensure the cost-effectiveness of the system.

  • PDF

A Study on the Indirect Radiation Exposure of the Medical Personnel Who is Responsible for Patient Safety in CT Examination (전산화단층촬영검사 시 검사실 내에 위치할 수 있는 의료인의 간접 피폭선량에 대한 연구)

  • Choi, Min-Hyeok;Jang, Ji-Sung;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.42 no.2
    • /
    • pp.105-111
    • /
    • 2019
  • A medical personnel could be placed beside a patient together in CT room to do Ambu-bag for a seriously ill patients or emergency patient. At this time, the medical personnel can be exposed indirect radiation unnecessarily. In this case, it is necessary to recognize indirect radiation dose levels and methods to reduce them using actual clinical CT protocols such as Chest, Abdomen, and Brain CT. We researched surface radiation dose with or without radiation protectors such as apron and goggles according to different distances far from gantry using two different CT scanners (Fixed MDCT and mobile CT). As a result, for Chest, Abdomen, and Brain CT with Fixed MDCT, indirect radiation dose on thorax portion were 0.047, 0.089, 0.034 mSv without apron. Also, those with apron were 0.007, 0.012, 0.006 mSv. In case of mobile CT, it was 0.014 mSv without apron and 0.005 mSv with apron. By using protectors and increasing the distance, we could reduce it to 97%. Systematic management is necessary based on the measured data in order to minimize radiation damage due to indirect exposure dose.

Organ dose conversion coefficients in CT scans for Korean adult males and females

  • Lee, Choonsik;Won, Tristan;Yeom, Yeon Soo;Griffin, Keith;Lee, Choonik;Kim, Kwang Pyo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.681-688
    • /
    • 2022
  • Dose monitoring in CT patients requires accurate dose estimation but most of the CT dose calculation tools are based on Caucasian computational phantoms. We established a library of organ dose conversion coefficients for Korean adults by using four Korean adult male and two female voxel phantoms combined with Monte Carlo simulation techniques. We calculated organ dose conversion coefficients for head, chest, abdomen and pelvis, and chest-abdomen-pelvis scans, and compared the results with the existing data calculated from Caucasian phantoms. We derived representative organ doses for Korean adults using Korean CT dose surveys combined with the dose conversion coefficients. The organ dose conversion coefficients from the Korean adult phantoms were slightly greater than those of the ICRP reference phantoms: up to 13% for the brain doses in head scans and up to 10% for the dose to the small intestine wall in abdominal scans. We derived Korean representative doses to major organs in head, chest, and AP scans using mean CTDIvol values extracted from the Korean nationwide surveys conducted in 2008 and 2017. The Korean-specific organ dose conversion coefficients should be useful to readily estimate organ absorbed doses for Korean adult male and female patients undergoing CT scans.

Medical Radiation Exposure in Children CT and Dose Reduction (소아 CT 촬영시 방사선 피폭과 저감화 방법)

  • Lee, Jeong-Keun;Jang, Seong-Joo;Jang, Young-Ill
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.1
    • /
    • pp.356-363
    • /
    • 2014
  • Recently pediatric CT has been performed by reduced dose according to tube current modulation이라고, this fact has a possibility more reduce a dose because of strong affect depend on tube current modulation. Almost all MDCT snow show and allow storage of the volume CT dose index (CTDIvol), dose length product (DLP), and effective dose estimations on dose reports, which are essential to assess patient radiation exposure and risks. To decrease these radiation exposure risks, the principles of justification and optimization should be followed. justification means that the examination must be medically indicated and useful. Results is using tube current modulation이라고 tend to the lower kV, the lower effective dose. In case of use a low dose CT protocol, we found a relatively lower effective dose than using tube current modulation. Average effective dose of our studies(brain, chest, abdomen-pelvis) less than 47%, 13.8%, 25.7% of germany reference dose, and 55.7%, 10.2%, 43.6% of UK(United Kingdom) reference dose respectively. when performed examination for reduced dose, we must use tube current modulation and low dose CT protocol including body-weight based tube current adaption.

Needling Depth of Cheonchu(ST25) with Computed Tomography: a Retrospective Study (Computed Tomography를 통한 천추(ST25)의 자침 깊이에 대한 후향적 연구)

  • Park, Hae In;Yang, Hyun Jung;Park, Sang Kyun;Lee, Kwang Ho
    • Journal of Acupuncture Research
    • /
    • v.32 no.3
    • /
    • pp.61-67
    • /
    • 2015
  • Objectives : The aim of this study is to investigate the safe needling depth of Cheonchu($ST_{25}$) retrospectively by using an abdomen abdomen computed tomography(CT), and to analyze the correlation between needling depth and the characteristics of the subjects. Methods : We marked spots 50 mm away from both sides of the umbilicus in the abdomen CT and measured the vertical distance to the parietal peritoneum from the skin surface as well as waist circumference. Correlations between measured depth of Cheonchu($ST_{25}$) and variables such as age, gender and waist circumference were analyzed. Results : Average depth of the Cheonchu(n = 90) was $3.21{\pm}0.87cm$, the minimum was 1.31 cm and the maximum was 5.63 cm. A definite positive correlation was noted between needling depth and waist circumference and a significant difference was observed in needling depth according to waist circumference groups. Conclusions : Needling depth of Cheonchu($ST_{25}$) varied depending on the patient's waist circumference; safe needling depth of Cheonchu($ST_{25}$) measured by abdomen CT is 1.31~5.63 cm.

A Case Report on Extranodal Marginal Zone B Cell of Mucosa-associated Lymphoid Tissue (MALT) Type Lymphoma Treated with Hangam-dan (항암단을 투여 받은 림프절 외 변연부 B세포 림프종 환자에 대한 증례보고)

  • Han, Sung-Soo;Cho, Chong-Kwan;Lee, Yeon-Weol;Yoo, Hwa-Seung
    • The Journal of Internal Korean Medicine
    • /
    • v.29 no.3
    • /
    • pp.810-818
    • /
    • 2008
  • Objective : The aim of this case report is to drive further studies evaluating the effectiveness of Korean oriental medicine on extranodal marginal zone B cells of MALT (mucosa-associated lymphoid tissue) type lymphoma. Methods : This case report is about a patient who was diagnosed with extranodal marginal zone B cell of MALT type lymphoma, who refused chemotherapy and preferred to be treated with Korean oriental medicine. Neck, chest abdomen & pelvis with enhanced computed tomography (CT) and positron emission tomography computed tomography (PET-CT) were performed to evaluate the anticancer effect of Hangam-dan (HAD). Results : The patient diagnosed with MALT showed partial response after receiving 17 months of Korean oriental medical treatment. Neck, chest, abdomen & pelvic CT and PET-CT show decrease in size. Conclusion : This case report shows a possibility that Korean oriental treatment could offer potential benefits for patients with extranodal marginal zone B cell of MALT type lymphoma.

  • PDF

F-18 FDG Uptake in Respiratory Muscle Mimicking Metastasis in Patients with Gastric Cancer (위암 환자에서 전이로 오인된 호흡근의 F-18 FDG 섭취)

  • Choi, Seung-Jin;Kim, Jeong-Ho;Hyun, In-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.4
    • /
    • pp.233-236
    • /
    • 2006
  • A 67-year-old man with a history of chronic obstructive pulmonary disease (COPD) underwent F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for staging of gastric cancer. The projection images of F-18 FDG PET/CT showed intensely increased F-18 FDG uptake in the anterior neck, chest wall, and upper abdomen. We suspected distant metastases of cervical lymph nodes, ribs, and peritoneum in gastric canter. However, the transaxial images of F-18 FDG PET/CT showed abnormal F-18 FDG uptake in scalene muscles of anterior neck, intercostal muscles of chest wall, and diaphragm of upper abdomen. Patients with COPD use respiratory muscles extensively on the resting condition. These excessive physiologic use of respiratory muscles causes increased F-18 FDG uptake as a result of increased glucose metabolism. The F-18 FDG uptake in respiratory muscles of gastric cancer patient with COPD mimicked distant metastases in cervical lymph nodes, ribs, and peritoneum.

Utility of Spinal Injury Diagnosis Using C-Spine Lateral X-Ray and Chest, Abdomen and Pelvis Computed Tomography in Major Trauma Patients with Impaired Consciousness

  • Jang, Yoon Soo;So, Byung Hak;Jeong, Won Jung;Cha, Kyung Man;Kim, Hyung Min
    • Journal of Trauma and Injury
    • /
    • v.31 no.3
    • /
    • pp.151-158
    • /
    • 2018
  • Purpose: The regional emergency medical centers manage the patients with major blunt trauma according to the process appropriate to each hospital rather than standardized protocol of the major trauma centers. The primary purpose of this study is to evaluate the effectiveness and influence on prognosis of additional cervical-thoracic-lumbar-spine computed tomography (CTL-spine CT) scan in diagnosis of spinal injury from the victim of major blunt trauma with impaired consciousness. Methods: The study included patients visited the urban emergency medical center with major blunt trauma who were over 18 years of age from January 2013 to December 2016. Data were collected from retrospective review of medical records. Sensitivity, specificity, positive predictive value, and negative predictive value were measured for evaluation of the performance of diagnostic methods. Results: One hundred patients with Glasgow coma scale ${\leq}13$ underwent additional CTL-spine CT scan. Mechanism of injury was in the following order: driver, pedestrian traffic accident, fall and passenger accident. Thirty-one patients were diagnosed of spinal injury, six of them underwent surgical management. The sensitivity of chest, abdomen and pelvis CT (CAP CT) was 72%, specificity 97%, false positive rate 3%, false negative rate 28% and diagnostic accuracy 87%. Eleven patients were not diagnosed of spinal injury with CAP CT and C-spine lateral view, but all of them were diagnosed of stable fractures. Conclusions: C-spine CT scan be actively considered in the initial examination process. When CAP CT scan is performed in major blunt trauma patients with impaired consciousness, CTL-spine CT scan or simple spinal radiography has no significant effect on the prognosis of the patient and can be performed if necessary.