• Title/Summary/Keyword: AVR

Search Result 407, Processing Time 0.029 seconds

Incidence of and Risk Factors for the Development of Significant Tricuspid Regurgitation after Isolated Aortic Valve Replacement

  • Minsang Kang;Jae Woong Choi;Suk Ho Sohn;Ho Young Hwang;Kyung Hwan Kim
    • Journal of Chest Surgery
    • /
    • v.56 no.5
    • /
    • pp.304-310
    • /
    • 2023
  • Background: The late progression of tricuspid regurgitation (TR) after mitral valve surgery is well known. However, few reports have described the progression of TR after aortic valve surgery. We investigated the incidence of and risk factors for the development of significant TR after isolated aortic valve replacement (AVR). Methods: This study analyzed patients with less than moderate TR who underwent isolated AVR at Seoul National University Hospital from January 1990 to December 2018. Significant TR was defined as moderate or higher. Echocardiographic follow-up was performed in all patients. The Fine-Gray model was used to identify clinical risk factors for the development of significant TR. Results: In total, 583 patients (61.7±14.2 years old) were included. Operative mortality occurred in 9 patients (1.5%), and the overall survival rates at 10, 20, and 25 years were 91.1%, 83.2%, and 78.9%, respectively. Sixteen patients (2.7%) developed significant TR during the follow-up period (13 moderate; 3 severe). The cumulative incidence of significant TR at 10, 20, and 25 years was 0.77%, 3.83%, and 6.42%, respectively. No patients underwent reoperation or reintervention of the tricuspid valve. Hemodialysis or peritoneal dialysis for chronic kidney disease (hazard ratio [HR], 5.188; 95% confidence interval [CI], 1.154-23.322) and preoperative mild TR (HR, 5.919; 95% CI, 2.059-17.017) were associated with the development of significant TR in the multivariable analysis. Conclusion: TR progression after isolated AVR in patients with less than moderate TR is rare. Preoperative mild TR and hemodialysis or peritoneal dialysis for chronic kidney disease were significant risk factors for the development of TR.

Clinical Midterm Results of Surgical Aortic Valve Replacement with Sutureless Valves

  • Soonchang Hong;Jung-Woo Son;Yungjin Yoon
    • Journal of Chest Surgery
    • /
    • v.57 no.3
    • /
    • pp.255-262
    • /
    • 2024
  • Background: Sutureless aortic valves may enable shorter procedure times, which benefits patients with elevated surgical risk. We describe the outcomes of patients with aortic stenosis who underwent aortic valve replacement (AVR) using the sutureless Perceval aortic bioprosthesis. Methods: Data from a retrospective cohort were obtained from a clinical database. The study enrolled patients with symptomatic severe aortic stenosis who underwent surgical AVR with a sutureless bioprosthesis between August 2015 and December 2020. In total, 113 patients were included (mean age, 75.3±8.4 years; 57.5% women; median Society of Thoracic Surgeons score, 9.7%; mean follow-up period, 51.19±20.6 months). Of these patients, 41 were octogenarians (36.2%) and 3 were nonagenarians (2.6%). Transthoracic echocardiography was employed to assess changes in ejection fraction (EF), left ventricular mass index (LVMI), and mean pressure gradient (MPG). Results: The in-hospital mortality rate was 2.6%, and 13 patients developed new-onset atrial fibrillation. A permanent pacemaker was implanted in 3 patients (2.6%). The median intensive care unit stay was 1 day (interquartile range [IQR], 1-2 days), and the median hospital stay was 12 days (IQR, 9.5-15 days). The overall survival rate at 5 years was 95.9%. LVMI and MPG were reduced postoperatively, while EF increased over the follow-up period. No structural valve deterioration was observed, and no meaningful paravalvular leakage developed during follow-up. Conclusion: The use of a sutureless valve in the aortic position is safe and feasible, even for high-risk elderly patients requiring surgical AVR. LVMI and MPG decreased postoperatively, while EF increased over the follow-up period.

Homograft Aortic Root Replacement (동종이식편을 이용한 대동맥 근부 치환술)

  • Kim Jae Hyun;Oh Sam Sae;Lee Chang-Ha;Baek Man Jong;Kim Chong Whan;Na Chan-Young
    • Journal of Chest Surgery
    • /
    • v.38 no.3 s.248
    • /
    • pp.197-203
    • /
    • 2005
  • Homograft aortic valve replacement (AVR) has many advantages such as excellent hemodynamic performance, faster left ventricular hypertrophy regression, resistance to infection and excellent freedom of thromboembolism. To find out the results of homograft AVR, we reviewed our surgical experiences. Material and Method: Eighteen patients (male female=16 : 2, mean age=39.3$\pm$16.2 years, range: 14$\~$68 years) who underwent homo-graft aortic valve replacement between May 1995 and May 2004 were reviewed. The number of homografts was 20 (17 aortic and 3 pulmonic homografts) including two re-operations. Ten patients had a history of previous aortic valve surgery. Indications for the use of a homograft were native valve endocarditis (n=7), prosthetic valve endocarditis (n=5), or Behcet's disease (n=8). The homograft had been implanted predominantly as a full root except in one patient in the subcoronary position. Result: Mean follow-up was 41.3 $\pm$ 26.2 months. There was one operative mortality. Postoperative complications included postoperative bleeding in 3 patients, and wound infection in 1. There was no late death. Three patients underwent redo-AVR. The etiology of the three reoperated patients was Behcet's disease (p=0.025). Freedom from reoperation was $87.5\pm8.3\%$, $78.8\pm11.2\%$ at 1, 5 years respectively, In patients with infective endocarditis, there was no recurrence of endocarditis. There was no thromboembolic complication. Conclusion: Although longer term follow-up with larger numbers of patients is necessary, the operative and mid-term results for homograft AVR was good when we took into account the operative risks of Behcet's disease or infective endocarditis. Behest's disease was a risk factor for reoperation after the homograft AVR. We think homograft AVR is the procedure of choice, particularly in patients with infective endocarditis.

Small Aortic Annulus in Aortic Valve Replacement; Comparison between Aortic Annular Enlargement Group and Patient-prosthesis Mismatch Group (협소한 대동맥판륜 환자에서의 대동맥판막 치환술; 대동맥판륜 확장술군과 환자-인공판막 부조화군의 비교)

  • Kim, Jae-Hyun;Oh, Sam-Sae;Yie, Kil-Soo;Shin, Sung-Ho;Baek, Man-Jong;Na, Chan-Young
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.200-208
    • /
    • 2007
  • Background: The effect of patient-prosthesis mismatch (PPM) on the clinical outcome following aortic valve replacement (AVR) remains controversial. This study compared the surgical outcomes of AVR between patients with a patient-prosthesis mismatch and those having undergone an aortic annular enlargement. Material and Method: Six hundred and twenty seven adult patients, who underwent AVR with stented bioprosthetic or mechanical valves, between January 1996 and February 2006, were evaluated. PPM was defined as an indexed effective orifice area (iEOA) ${\leq}0.85cm^2/m^2$, and Severe if the iEOA${\leq}0.65cm^2/m^2$ PPM was present in 103 (16.4%, PPM group) patients, and severe in 11 (1.8%, SPPM group). During the period of the study, 21 patients underwent an AVR with annular enlargement (AE group). Result: The mean iEOA of the AE group was larger than that of the PPM group ($0.95\;vs.\;0.76cm^2/m^2,\;p=0.00$). The AE group had longer CPB, ACC and operation times than the PPM group, and showed a tendency toward higher operative mortality (14.3% vs. 2.9%, p=0.06). The SPPM group had higher AV pressure gradients (peak/mean) than the AE group (72/45 mmHg vs. 38/25 mmHg, p=0.02/0.06) and suffered more AV related events (AV reoperation or severe aortic stenosis)(45.5% vs. 9.5%, p=0.03). LV masses were not regressed in the patients who experienced an AV related event. Conclusion: During AVR in patients with a small aortic annulus, annular enlargement should be carefully applied taking into account the high risk of operative mortality due to annular enlargement and co-morbidities of patients. Aortic annular enlargement; however, should be considered as an alternative method in patients expected to have a severe PPM after an AVR.

Gymnosporangium asiaticum and G. yamadae: Morphological Characteristics, Pathogenicity and Epidemics by Rainfall (Gymnosporangium asiaticum과 G. yamadae의 형태학적 특징 및 병원성과 강우량에 의한 병발생 차이)

  • Ryu, Jong-Suk;Lee, Soon-Gu
    • Research in Plant Disease
    • /
    • v.10 no.3
    • /
    • pp.175-182
    • /
    • 2004
  • Teliospores of two species of Gymnosporangium asiaticum and G.yamadae collected and identified from Juniperus chinensis, J.chinensis L.var.kaizuka. G.asiaticum was identified as the thick membraned (cell-walled) teliospores (avr 2.5 ${\mu}{\textrm}{m}$) and thin membraned teliospores (avr 1.2 ${\mu}{\textrm}{m}$), and the telia of G.asiaticum was bluntly conical shaped and occured on the leaves and branches of Chinese junipers. G.yamadae was identified as the thick membraned (cell-walled) teliospores (avr 2.5 ${\mu}{\textrm}{m}$) and thin membraned teliospores (avr 1.2 ${\mu}{\textrm}{m}$), and the telia of G. yamadae was gall or floral shaped and occured on the leaves and branches of Chinese junipers. Both of the telia of the two species of Gymnosporangium were occurred in a same tree of Juniperus chinensis L. var. kaizuka at the same time. But the dominant species is G. asiaticum. The more rainfall in the late of April (the season of forming basidiospore), the more rust diseases in Chaenomeles sinensis. C. sinensis, and Pyrus pyrifolia var. culta were infected by G. asiaticum (basidiospores) but Malus siebodii was not infected by G.asiaticum.

Simple Interrupted Suturing for Aortic Valve Replacement in Patients with Severe Aortic Stenosis

  • Lee, Jun Oh;Lee, Chee-hoon;Kim, Ho Jin;Kim, Joon Bum;Jung, Sung-Ho;Joo, Suk Jung;Chung, Cheol Hyun;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • v.53 no.6
    • /
    • pp.332-338
    • /
    • 2020
  • Background: Attaining an adequate effective orifice area (EOA) is definitive goal in aortic valve replacement (AVR). The simple interrupted suture (SIS) technique could be a solution to achieve this goal, but limited data are available in the literature. This study aimed to compare hemodynamic differences between the SIS and non-everting mattress suture (NMS) techniques. Methods: From our database, 215 patients who underwent AVR for severe aortic stenosis were extracted to form the overall cohort. From March 2015 to November 2016, the SIS technique was used in 79 patients, while the NMS technique was used in 136 patients. Hemodynamic outcomes were evaluated, as detected by transthoracic echocardiography and computed tomography. Results: There were no significant differences in baseline characteristics between the 2 groups. On immediate postoperative echocardiography, the SIS group showed a significantly wider EOA (1.6±0.4 vs. 1.4±0.5 ㎠, p=0.007) and a lower mean pressure gradient (PG) (13.3±5.4 vs. 17.0±6.0 mm Hg, p<0.001) than the NMS group. On follow-up echocardiography, the SIS group continued to have a wider EOA (1.6±0.4 vs. 1.4±0.3 ㎠, p<0.001) and a lower mean PG (11.0±5.1 vs. 14.1±5.5 mm Hg, p<0.001). There was no significant difference in paravalvular leakage. Conclusion: The SIS technique for AVR was associated with a wider EOA and a lower mean PG. The SIS technique could be a reasonable option for AVR.

Hybrid Intelligent System Using PSO/Bacterial Foraging and PID Controller Tuning

  • Kim Dong-Hwa
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2006.05a
    • /
    • pp.22-34
    • /
    • 2006
  • o GA-BF approach for improvement of learning and optimization in GA o GA-BF has better response on various test functions o Satisfactory PID controller tuning in AVR, motor vector control systems o Potentially useful in many practically important engineering optimization problems

  • PDF

A study on Parallel running Hydroelectric power Generation breakdown through Reactive Current (무효횡류에 의한 병렬 운전 수력발전소 고장에 관한 연구)

  • Ha, Sung-Jong;Kim, Ji-Chan;Ahn, Jae-Hu;Byeon, Gyu-Yong;Pi, In-Seop;Ye, Cheol-Hae;Jeong, Ho-Un
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.214-215
    • /
    • 2011
  • 2대의 교류발전기 G1과 G2가 병렬운전 중 일 때 내부 기전력 E1, E2는 같은 위상이지만, 크기가 E1>E2로 될 때 두 발전기 사이에는 전위차가 있으므로 횡류 Ic가 흐르게 된다. 남강수력발전소는 주변압기(15MVA, 3.45/66kV) 한대에 수차발전기(7MVA) 2대가 병렬로 운전 중인데, 남강수력 제1호 수차발전기 AVR 시스템의 고장(RS 1기판)으로 G1 발전기의 내부 유기전압과 G2 발전기의 내부 유기전압에 차가 생기고, 이 양자의 차 전압을 전원으로 하여 발전기 G1과 G2를 환류하는 전류가 발생하여 발전 기동 중 비상정지 하였다. 본 논문에서는 고장원인 분석과정 및 AVR 시스템 보수 전 후 파형 비교 및 사고원인을 논하고자 한다.

  • PDF