• 제목/요약/키워드: AT power simulation

검색결과 3,145건 처리시간 0.042초

고온초전도선을 이용한 초전도전력케이블의 실시간 시뮬레이션 알고리즘 개발 (Development of a Real-Time Simulation Algorithm of HTS Power Cable using HTS Wire)

  • 김재호;박민원;조전욱;심기덕;유인근
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권3호
    • /
    • pp.54-58
    • /
    • 2006
  • In this paper, authors developed a real-time simulation algorithm for the power device application of HTS(High Temperature Superconducting) wire by using Real Time Digital Simulator(RTDS). At present, in order to extend the power capacity of some area where has a serious problem of power quality. especially metropolitan complex city, there are so many problems such as right of way for power line routes. space for downtown substations. and the environmental protection, etc. HTS technology can be useful to overcome this problem. Recently, according to the advanced HTS technology, the power application is being researched well. Simulation is required for safety before installation of HTS power cable, a fabrication model used at the power system simulation. This paper describes a real time digital simulation method for the application of HTS wire to power device. For the simulation analysis, test sample of HTS wire was actually manufactured. And the transient phenomenon of the HTS wire was analysed in the simulated utility power grid. This simulation method is the world first trial in order to obtain much better information for installation of HTS power device into a utility network.

발전소 시뮬레이터 기술동향 및 국내 기술자립 계획 (The Status of Power Plant Simulation Technology and KEPCO's Plan for Self-Reliance of the Technology)

  • 신영철;이용관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.525-528
    • /
    • 1993
  • KEPCO Research Center is carrying out a simulator(full scope replica type) development project for two nuclear power plants(Kori-2, Younggwang-3,4) and one fossil power plant(Poryong-3,4). In this project, we aim not only the installation of high performance simulators at the power plant sites but also the realization of self reliance of power plant simulation technology in Korea. In the course of preparing procurement specification for the 3 simulators, the present status of power plant simulation technology has been surveyed and is presented in this paper. The fidelity of simulation and the automation of simulation model production has been greatly improved due to the ever increasing computing power of today's workstations. The need and importance of the application of high fidelity simulators to the operator training is refocused since the accident at TMI Nuclear Power Plant, U.S.A.

  • PDF

AlGaN/GaN HEMT 전력소자 시뮬레이션에 관한 연구 (A Study on the Simulation of AlGaN/GaN HEMT Power Devices)

  • 손명식
    • 반도체디스플레이기술학회지
    • /
    • 제13권4호
    • /
    • pp.55-58
    • /
    • 2014
  • The next-generation AlGaN/GaN HEMT power devices need higher power at higher frequencies. To know the device characteristics, the simulation of those devices are made. This paper presents a simulation study on the DC and RF characteristics of AlGaN/GaN HEMT power devices. According to the reduction of gate length from $2.0{\mu}m$ to $0.1{\mu}m$, the simulation results show that the drain current at zero gate voltage increases, the gate capacitance decreases, and the maximum transconductance increases, and thus the cutoff frequency and the maximum oscillation frequency increase. The maximum oscillation frequency maintains higher than the cutoff frequency, which means that the devices are useful for power devices at very high frequencies.

동적 핸드오프와 전력제어를 고려한 적응배열 시스템의 네트워크 시뮬레이션 (System Level Network Simulation of Adaptive Array with Dynamic Handoff and Power Control)

  • Yeong-Jee Chung;Jeffrey H. Reed
    • 한국시뮬레이션학회논문지
    • /
    • 제8권4호
    • /
    • pp.33-51
    • /
    • 1999
  • In this study, the system level network simulation is considered with adaptive array antenna in CDMA mobile communication system. A network simulation framework is implemented based on IS-95A/B system to consider dynamic handoff, system level network behavior, and deploying strategy into the overall CDMA mobile communication network under adaptive array algorithm. Its simulation model, such as vector channel model, adaptive beam forming antenna model, handoff model, and power control model, are described in detail with simulation block. In order to maximize SINR of received signal at antenna, Maximin algorithm is particularly considered, and it is computed at each simulation snap shot with SINR based power control and handoff algorithm. Graphic user interface in this system level network simulator is also implemented to define the simulation environments and to represent simulation results on real mapping system. This paper also shows some features of simulation framework and simulation results.

  • PDF

The Influence of Forest Fire Simulation on the Properties of Polymer Insulators

  • Lee, Won-Kyo;Choi, In-Hyuk;Lee, Dong-Il;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권5호
    • /
    • pp.161-164
    • /
    • 2009
  • Forest fire simulation tests were performed with polymer and porcelain insulators at GOCHANG Power Testing Center. These tests consisted of open flames causing a temperature rise of up to $600{\sim}800^{\circ}C$ measured at the insulator surfaces. Mechanical and electrical characteristics such as the specific mechanical load, the low frequency dry flashover voltage and the impulse flashover voltage were analyzed for the polymer insulators before, during and after the simulation tests and then compared to the porcelain insulators. At the end of the fire simulation tests, there was no detrimental deterioration of any of the insulators. All the insulators passed the KEPCO specification criteria. This study showed that the forest fire simulation had no impact on the polymer insulators.

폴리머 애자의 산불 신뢰성 평가 연구 (A Study on the reliability analysis of Forest Fire on Polymer Insulators)

  • 이원교;최인혁;황갑철;최한열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.460-461
    • /
    • 2008
  • The forest fire simulation tests were performed with polymer and porcelain insulators at Gochang testing center. These tests consisted of energizing 90 kV at line-to-ground voltage of 154 kV lines and open flame rising up to $600-630^{\circ}C$ as being measured at insulator surface. Mechanical and electrical characteristics such as specific mechanical load, leakage current, low frequency dry flashover voltage and impulse flashover voltage were analyzed for the polymer insulators before, during and after simulation tests compared with porcelain insulators. At the end of fire simulation tests, there was no detrimental deterioration of any insulators. All insulators passed the criteria of KEPCO specification. This study showed that forest fire simulation had no impact on polymer insulators.

  • PDF

정전력모델을 이용한 전기철도 시스템의 회로 모델링 및 해석기법 (A Modeling and Analysis of Electric Railway System Using Constant Power Model)

  • 홍재승;김주락;오광해;창상훈;김정훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 춘계학술대회 논문집
    • /
    • pp.116-122
    • /
    • 2000
  • This paper presents a simulation method with constant power model for the train load. In power system simulation loads could be modeled as a constant power, constant current, constant Impedance or a function of voltage and frequency. At this time, however, representing a train load as the function is difficult because of the lack of data. Therefore as a first step, simulation method with a constant power model fer a train is studied, and the test result is compared with the simulation result using the constant Impedance model.

  • PDF

Numerical simulation of slit wall effect on the Taylor vortex flow with radial temperature gradient

  • Liu, Dong;Chao, Chang-qing;Zhu, Fang-neng;Han, Xi-qiang;Tang, Cheng
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권4호
    • /
    • pp.304-310
    • /
    • 2015
  • Numerical simulation was applied to investigate the Taylor vortex flow inside the concentric cylinders with a constant radial temperature gradient. The reliability of numerical simulation method was verified by the experimental results of PIV. The radial velocity and temperature distribution in plain and 12-slit model at different axial locations were compared, and the heat flux distributions along the inner cylinder wall at different work conditions were obtained. In the plain model, the average surface heat flux of inner cylinder increased with the inner cylinder rotation speed. In slit model, the slit wall significantly changed the distribution of flow field and temperature in the annulus gap, and the radial flow was strengthen obviously, which promoted the heat transfer process at the same working condition.

바닥재 냉각기 기포유동층의 기체-고체 연전달 분석 (Gas-Solid Heat Transfer Analysis of Bubbling Fluidized Bed at Bottom Ash Cooler)

  • 이규화;김동원;이종민;박경일;박병철
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.97-101
    • /
    • 2022
  • In this study we investigated the gas to solid heat transfer of bubbling fluidized bed bottom ash cooler installed at the Donghae power plant in South Korea. Several different analyses are done through 1-D calculations and 3-D CFD simulation to predict the bottom ash exit temperatures when it exits the ash cooler. Three different cases are set up to have consideration of unburnt carbon in the bottom ash. Sensible heat comparison and heat transfer calculation between the fluidization air and the bottom ash are conducted and 3-D CFD analysis is done on three cases. We have obtained the results that the bottom ash with unburnt carbon is exiting the ash cooler, exceeding the targeted temperature from both 1-D calculation and 3-D CFD simulation.

고온초전도 선의 전력 응용을 위한 실시간 시뮬레이션 알고리즘 개발 (Development of a real-time simulation algorithm for the application of the HTS tape)

  • 강진주;김재호;제항호;조전욱;심기덕;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.260-261
    • /
    • 2006
  • This paper describes a real time digital simulation method for the application of HTS tape to power devices. At present, in order to extend the power capacity of some area which has a serious problem of power quality, especially metropolitan complex city. there are so many problems such as ROW for cable line routes, space for downtown substations, and the environmental protection, etc. HTS technology is one of the best solutions. Simulation is required for safety before install of HTS power cable, a fabrication model used at the power system simulation. Here, in this paper, authors developed an algorithm connected with HTS by using Real-Time Digital Simulator(RTDS).

  • PDF