• 제목/요약/키워드: AT Feeding system

검색결과 639건 처리시간 0.023초

단선 AT 급전계통의 전차선-레일 단락 고장전류 분석 (The Analysis of Trolley-Rail Short Circuit Current in a Single Track AT Feeding System)

  • 조규정;류규상;이훈도;허승훈;김철환;권성일;김철환
    • 전기학회논문지
    • /
    • 제64권12호
    • /
    • pp.1659-1665
    • /
    • 2015
  • In general, AT(Auto-transformer) is used to improve voltage sag and inductive interference in power lines and communication lines in AC electrical railway feeding system. Especially, Korean AT feeding system has different composition compared to other countries like Japan or France, so that it has some special characteristics. However, relays imported from other countries have been used in Korea, and settings of these relays should be modified and reflect distinct characteristics of Korean AT feeding system. Therefore, study about fault analysis based on modeled AT feeding system is important. In this paper, we modeled a single track AT feeding system by using PSCAD and analyzed fault current flow in case of trolley-rail short circuit fault. Finally, we presented current magnitude of each branch expressed by boosting current of AT.

전기철도 AT급전방식 보호시스템 최적구성 방안 연구 (A Study on the Protection System for AT Feeding on the Electric Railway)

  • 창상훈;이형수;홍재승;김정훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.344-351
    • /
    • 1999
  • The safe operation of electro railways is greatly dependant on its protective systems. The system so-called Fault Protection Wire(FW) is now widely adapted to protect in AT feeding systems. It is connected between the feeder and trolley circuit to return the fault current to autotransfonmers at substation. This paper computed the distribution of fault currents at FW in the system and also evaluated the safety from electric shock when ground fault or flashover occur in the feeding system. The results show FW is useful to protect power supply network from fault in electric railways

  • PDF

교류 AT 급전계통에서의 단권변압기 설치위치의 최적화 (Location of Auto Transformer in AC AT Feeding System)

  • 한문섭;이장무
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1248-1250
    • /
    • 2002
  • AC AT feeding system is possible to do the long distance feeding due to compensate the voltage drop. Nowaday this is a typical and efficient type all over the world in high speed train and heavy transport capacity. Normally a Auto-transformer is installed at regular internal (5 to 10km) between Substation and Sectioning post, this study is reviewed the voltage drop according to train movement and the optimal location of auto transformer, and provided the efficient feeding configuration.

  • PDF

Cases of Eco-Friendly Pigsty and Hog Feeding and Management Based on u-IT Information Systems

  • Jang, Ik Hun;Park, Seong Hee;Choi, Young Chan;Kim, Young Hwa
    • Agribusiness and Information Management
    • /
    • 제4권2호
    • /
    • pp.42-49
    • /
    • 2012
  • This study introduces cases of individual feeding systems for sow and the sow sorters which are the subparts of an eco-friendly feeding and management system based on a u-IT program using the hog feeding and management information system. The purpose of this study is to conduct an analysis of economic feasibility on cases of the improvement of the system using the u-IT and to provide information on the positive effects of an introduction of an eco-friendly pigsty and hog feeding and management system to hog raisers and government officials. The literature review and background section examine the effects of the introduction of u-IT technology into the field of livestock raising, hog feeding and management information system, and the eco-friendly feeding and management system based on the u-IT. This paper will present the results of the analysis on the effects and the economic feasibility of the individual feeding system for sow and the sow sorter utilizing the u-IT technology and information systems. The results of this study will contribute to the sustainable development of the hog raising industry by showing that the new feeding and management system utilizing the u-IT can not only increase the efficiency and productivity of farm management but also contribute to efficient, eco-friendly hog feeding and management.

  • PDF

A Study on a Catenary Impedance Estimation Technique using Boosting Current Compensation Based on Current Division Characteristics of an AT Feeding System

  • Jung, Hosung;Kim, Hyungchul;Chang, Sang-Hoon;Kim, Joorak;Min, Myung-Hwan;An, Tae-Pung;Kwon, Sung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1370-1376
    • /
    • 2015
  • Generally, an autotransformer(AT) feeding system consists of double tracks, up and down, with the trolley wire and feeder wire of the up and down tracks connected in the sectioning post(SP). Consequently, load current or fault current flows on two tracks based on catenary impedance characteristics, making it difficult to estimate catenary impedance accurately. This paper presents a technique for the estimation of catenary impedance using boosting current compensation based on the current division characteristics of an AT feeding system to improve the operation performance of impedance relay. To verify the technique, we model an AT feeding system through a power analysis program (PSCAD/EMTDC) and simulate various operation and fault conditions. Through the simulation, we confirmed that the proposed technique has estimated catenary impedance with a similar degree of accuracy to the actual catenary impedance

국내 교류 전기철도 급전계통 보호용 과전류 계전기 모델링 및 과부하 보호 협조에 관한 연구 (A Study on the Overcurrent Relay Modeling and Protective Coordination for Overload in Domestic AC Electrical Railway System)

  • 김현동;조규정;허승훈;김철환
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1121-1127
    • /
    • 2016
  • In this paper, modeling of overcurrent relay(OCR) to protect domestic AC electric railway Auto Transformer(AT) feeding system and operation characteristic analysis on overload condition are described. The target system of this paper is actual site where overload trip of circuit breaker occurs frequently. Because this AT feeding system is made of parallel single track which had a load(electric train) respectively, and is connected with only T phase of Scott Transformer. In addition, this system has been feeding 66kV voltage by KEPCO, not 154kV. We focus on protective coordination of Scott Transformer primary side and secondary side OCR for Korea single track AC electrical railway system in operation currently. We modeled single track AT feeding system and OCR. Also we performed faults and overload analysis for verification of OCR's setting values and system modeling. To analyze above mentioned research, we used PSCAD/EMTDC software tool.

박피 마늘의 품위판정 기술개발에 관한 기초연구(I) -영상식 마늘 선별기용 반전장치 개발- (Basic Study on Quality Evaluation Technique for Peeled Garlics(I) -Rotation sytem for vision-based garlic sorter-)

  • 이종환;이성범;안청운
    • Journal of Biosystems Engineering
    • /
    • 제26권3호
    • /
    • pp.271-278
    • /
    • 2001
  • Many workers in the garlic peeling factory are separating the sound peeled garlics from the unpeeled and defective ones in a manual way. In order to reduce the seasonal labor requirement and operating cost, the mechanized garlic sorting system such as the vision-based garlic sorter should be developed. This study was conducted as one of basic studies on developing quality evaluation technique for peeled garlics, especially to developed the system for acquiring the whole surface images of garlics with a CCD camera. The following results were obtained from this study. 1. The belt-type garlic rotation system was devised to apply for the vision-based garlic sorter and was tested to decide the criteria of design and optimum conveying speed. 2. To evaluate the performance of the developed garlic rotation system, feeding rate and rotating rate were measured under the conditions of four experimental factors such as the inclined angle of rotating belt, the inclined angle of feeding belt, the height of plate arrays on feeding belt and the conveying speed of belts. And the capacity of the system according to mixture ratios of peeled garlics and unpeeled garlics was analyzed as a feasibility test. 3. For the inclined angle of rotating belt 20°and height of plate array on feeding belt 22㎜, the maximum rotating rate for garlic samples including unpeeled ones was 81.1% at the conveying speed of 4.2 garlic/sec. And under these condition, the maximum feeding rate was 85% at the inclined angle of feeding belt 6.5°. 4. The capacity of the developed garlic rotation system was almost constant regardless of mixture ratio of peeled garlics and unpeeled garlics and its range was 2.95∼3.92 garlic/sec. At the conveying speed of 4.2 garlic/sec, the capacity of the garlic rotation system was calculated ad 58∼64 kg/hr. 5. To improve performance of the garlic rotation system, it is recommended to develop a device to slide garlics into feeding belt.

  • PDF

AT급전방식에서 AT간격에 따른 전압강하 및 대지누설전류에 대한 연구 (A Study on the Voltage Drop and Earth Leakage Current according to Interval of AT in the AT Feeding Method)

  • 김민석;최승혁;이종우
    • 전기학회논문지
    • /
    • 제60권9호
    • /
    • pp.1708-1714
    • /
    • 2011
  • AT feeding system of the electric railway system is installed every about 10km at between the feeder and catenary in parallel and the mid-point of the transformer is connected to the rail The supply voltage of this system is doubled than rolling stock voltage. So the voltage drop is smaller than usual. And the other merit of this system is the decreasing inductive disturbance to the communication line because of the reduced current in rail which runs reversed in a point of view of rolling stock. Also, ATP(Auto Transformer Post) is installed to reduce the voltage drop and to mitigate the inductive disturbance, but still now the proper distance between the ATP and AT feeding system is not established which ranges from 2 to 10[km]. The stable result of simulation(which is set that the end of the line AT is installed) to the voltage drop and inductive disturbance can not analyzes the effect to the supply system due to the ATP. This paper analyzes the effect to the system depending on the location of ATP by forecasting the voltage drop and inductive disturbance.

아크 용접 와이어의 장거리 송급을 위한 Push-pull 방식의 와이어 송급장치 개발 (Development of Push-pull Type Arc Welding Wire Feeder)

  • 윤현준;황인성;김동철;강문진;최기갑
    • Journal of Welding and Joining
    • /
    • 제31권3호
    • /
    • pp.39-43
    • /
    • 2013
  • It is difficult to feed welding wire stably, when the distance between welding wire feeder and welding torch is far enough. In order to solve this problem, arranging a extension wire feeder between them could be one of useful methods. However, the welding wire could be twisted up in the extension cable between extension and terminal wire feeders in the case that RPM of extension wire feeding motor is higher than that of terminal motor. In this study, feeding problem of normal push-pull wire feeding system occurred at low welding current range less than 250A. In order to solve the problem, two new wire feeding systems of push-pull type were introduced. Welding wire feeding tests were preformed in the range of 150A to 400A with the developed push-pull feeding system. In addition, weldability test was performed at the welding current of 200A, 300A, and 400A. The welding wire twisting problem that was observed in the normal feeding system did not occur in the new push-pull wire feeding system.

액체추진기관 추진제 공급계 시험설비 (The test facility for propellant feeding system of liquid propulsion system)

  • 권오성;나한비;이중엽;정용갑;조남경;길경섭
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제23회 추계학술대회 논문집
    • /
    • pp.79-82
    • /
    • 2004
  • 추진제 공급계는 발사체에 탑재될 엔진에 추진제를 요구조건 (유량, 온도, 압력 등)에 맞게 공급하는 시스템을 말한다. 본 시험 설비는 추진제 공급 시스템 개발시 주요 구성기술인 가압 시스템 개발, 탱크 내 프로세스 개발, 추진제 배관 시스템 개발을 위해 구축되고 있다. 본 논문에서는 현재 항 우연 내에 구축중인 추진제 공급 시험 설비를 소개한다.

  • PDF