• Title/Summary/Keyword: ASES

Search Result 165, Processing Time 0.024 seconds

Clinical outcomes of bending versus non-bending of the plate hook in acromioclavicular joint dislocation

  • Joo, Min Su;Kwon, Hoi Young;Kim, Jeong Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.4
    • /
    • pp.202-208
    • /
    • 2021
  • Background: We aimed to assess the effect of plate hook bending in treatment of acromioclavicular (AC) dislocation by analyzing clinical and radiological results according to the angle of the plate hook (APH). Methods: This was a retrospective, observational, case-control study including 76 patients with acute AC joint dislocation that were divided into two groups according to treatment with bent or unbent plate hook. The visual analog scale (VAS), the American Shoulder and Elbow Surgeons (ASES) shoulder score, and range of motion (ROM) were evaluated as clinical outcomes. Comparative coracoclavicular distance (CCD) was measured to evaluate radiological outcomes. Results: While the VAS and ASES of the bending group at 4 months after surgery were significantly higher (p=0.021 and p=0.019), the VAS and ASES of the bending group at other periods and ROM of the bending group showed no significant difference. The initial CCD decreased from 183.2%±25.4% to 114.3%±18.9% at the final follow-up in the bending group and decreased from 188.2%±34.4% to 119.1%±16.7% in the non-bending group, with no statistical difference (p=0.613). The changes between the initial and post-metal removal CCD were 60.2%±11.2% and 57.3%±10.4%, respectively, with no statistical difference (p=0.241). The non-bending group showed greater subacromial osteolysis (odds ratio, 3.87). Pearson's coefficients for the correlation between APH and VAS at 4 months after surgery and for that between APH and ASES at 4 months after surgery were 0.74 and -0.63 (p=0.027 and p=0.032), respectively. Conclusions: The APH was associated with improved postoperative pain and clinical outcomes before implant removal and with reduced complications; therefore, plate hook bending is more useful clinically during plate implantation.

Percutaneous Pinning in Unstable Two-parts Fracture of Surgical Neck in Humerus (상완골 불안정성 외과적 경부 이분 골절의 경피적 핀 삽입 고정술)

  • Park Jin-Young;Rho Han-Jin;Kim Myung-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.3 no.1
    • /
    • pp.26-32
    • /
    • 2000
  • Purpose : The aim of this study is the assessment of the clinical outcomes after percutanous pinning of unstable two-parts fracture of surgical neck in humerus. Materials and Methods: This study was based on thirteen cases of non-comminuted unstable surgical neck fracture of humerus among 19 cases, which followed-up more than one year. Follow-up averaged 29 months. We treated with percutaneous pinning techniques and assessed clinical outcomes. Functional evaluation was performed using the standard method of research committee of American Shoulder and Elbow Surgeons(ASES). Results: Last follow-up ROM of shoulder joint were 142 degrees of forward elevation, 57 degrees of external rotation, 72 degrees of external rotation in 90 degrees abduction, and T8 of internal rotation. Pain scale was l(range : 0∼3). ASES scores was 86.2(range : 63.3~98.3). Patient satisfaction based on ASES were excellent in 6 cases, good in 5 cases, fair in 1 case, poor in 1 case. A case of fair result was caused by limitation of motion in shoulder joint and poor case was paraplegia patient after traffic accident. Conclusion : Percutaneous pinning is recommended for non-comminuted unstable fracture of surgical neck in humerus.

  • PDF

Significant radiologic factors related to clinical outcomes after arthroscopic rotator cuff retear repair

  • Joo, Min-Su;Kim, Jeong-Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.3
    • /
    • pp.173-181
    • /
    • 2022
  • Background: Healing of the tendon itself is not always related to successful clinical outcomes after rotator cuff repair. It was hypothesized that certain radiologic factors affecting clinical outcomes could exist in case of the retear after arthroscopic rotator cuff repair (ARCR) and the radiologic factors could help predict clinical process. The purpose of this study was to identify the radiologic factors associated with clinical outcomes of the retear after ARCR. Methods: Between January 2012 and December 2019, among patients with sufficient footprint coverage for ARCR, 96 patients with Sugaya classification 4 or higher retear on follow-up magnetic resonance imaging were included. The association between clinical outcomes such as American Shoulder and Elbow Surgeons (ASES) score, Constant score and range of motion and radiologic variables such as initial tear dimension, retear dimension, variance of tear dimension, critical shoulder angle, acromial index, and acromiohumeral distance was analyzed. Results: Preoperatively, the ASES and Constant scores were 59.81±17.02 and 64.30±15.27, respectively. And at the last follow-up, they improved to 81.56±16.29 and 78.62±14.16, respectively (p<0.01 and p<0.01). In multiple linear regression analysis, the variance of the mediolateral dimension of tear had statistically significant association with the ASES and Constant scores (p<0.01 and p=0.01). Conclusions: In patients with the retear after ARCR, the variance in the mediolateral dimension of tear had significantly negative association with the clinical outcomes. This could be considered to be reference as relative criteria and needed more sample and mechanical study.

Outcomes after Arthroscopic Repair of Anterior Shoulder Instability after Metal Anchor to Biodegradable Anchor Fixation (견관절 전방 불안정성에 대한 관절경 치료 결과: 금속 나사못 및 흡수성 나사못 고정의 결과 비교)

  • Choi, Chang-Hyuk;Kim, Shin-Kun;Han, Bo-Ram
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.158-164
    • /
    • 2008
  • Purpose: We compared the results of arthroscopic Bankart repair using metal and biodegradable anchor fixation. Materials & Methods: We reviewed 26 patients with anterior shoulder instability treated by arthroscopic Bankart repair from October, 2006, to March, 2007, 15 patients with metal anchors and 11 patients with biodegradable anchors. The average age was 27.4 years old (range: 17~55) and mean follow-up was 14 months (range: 12~17 months). Functional outcome was evaluated using the Korean Shoulder Score for Instability (KSSI), Rowe's Bankart Grading scale (RBGS), ASES score, and UCLA scores. Results: In the metal-anchor group, the improvements of mean KSSI, ASES, UCLA score, and RBGS were 20.6, 24.0, 4.0, and 45.5, respectively. In the biodegradable anchor group, improvements of mean KSSI, ASES, UCLA score, and RBGS were 21.0, 23.6, 4.6, and 48.9. The improvements in final outcomes were not significantly different (p>.05). One metal problem and one traumatic redislocation occurred in the metal group. Conclusion: Both techniques produced satisfactory outcomes in the treatment of traumatic anterior instability. The biodegradable anchor group could also avoid problems with metal anchors.

Tenodesis of Long Head of the Biceps Brachii Tendon with Bioabsorbable Interference Screw (체내 흡수성 간섭 나사를 이용한 상완 이두건 장두건 고정술의 임상적 결과)

  • Yum, Jae-Kwang;Sin, Yong-Woon;Lee, Sang-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.78-83
    • /
    • 2007
  • Purpose: This study reports the clinical results of the tenodesis of long head of the Biceps brachii tendon with bioabsorbable interference screw by minimal open procedure. Materials and Methods: Ten cases of 10 patients (7 male, 3 female) were included in this study. The average age was 45.8 years old and the average period from the symptom onset to operation was 13.7 months. Average preoperative ASES score was 38.5. The causes of injury was; sports activities in 4 patients, unknown in 4 patients, industrial accident in 1 patient and traffic accident in 1 patient. The average follow up period was 12.1 months. Tenodesis with bioabsorbable interference screw by minimal open precedure was performed in all cases. Results: The ASES score improved to 87.5 at last follow up period and 6 cases had full range of motion of the shoulder. 4 cases had mild limited range of motion of the shoulder without any problem in normal daily activity. Conclusion: It was assumed that tenodesis of long head of the biceps brachii tendon with bioabsorbable interference screw by minimal open precedure was one of the good methods with good clinical results.

Outcome in Impingement Syndrome of the Shoulder According to Presence of Stiffness (견관절 충돌 증후군 환자에서 강직 여부에 따른 치료 결과)

  • Moon, Gi-Hyuk;Lee, Jae-Wook;Yoo, Moon-Jib;Park, Jin-Young
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.1
    • /
    • pp.45-50
    • /
    • 2004
  • Purpose: The purpose of this study is to compare the outcome of operative results in the impingement syndrome of the shoulder with and without the stiffness. Material and Method: Seventy-six patients who had the impingement syndrome without stiffness were evaluated, and treated with the subacromial decompression and 24 patients who had the impingement syndrome with stiffness, were treated with the subacromial decompression and the manipulation. The average follow-up period was 32 months. Result: The impingement syndrome of the shoulder with stiffness was more severe in the preoperative pain and worse in ASES score than without stiffness. The postoperative pain and ASES score improved in the both group. The satisfactory groups were 67% in the group with stiffness and 80% without stiffness. The satisfactory rate was 83% in the group with stiffness and 93% without stiffness. The satisfactory groups with diabetes were 47% in the group with stiffness and 81% without stiffness. Forward elevation, exeternal rotation at the side and internal rotation improved in both groups postoperatively and there were no statistically significant differences postoperatively External rotation was restricted statistically in the group with stiffness. Conclusion: Although patients may not regain the full range of motion, the technique of manipulation followed by arthroscopic subacromial decompression offers good pain relief and satisfactory functional recovery for the impingement syndrome with stiffness. However preoperative counseling is necessary for the impingement syndrome combined with diabetes and stiffness due to poor out come.

  • PDF

Clinical results of arthroscopic tenodesis of the proximal biceps tendon using by interference screw (관절경적 상완 이두근 건고정술의 임상적결과)

  • Kweon, Seok-Hyun;Chun, Churl Hong;Choi, Yoon Hong;Han, Sang Su;Kim, Jeong Woo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.1
    • /
    • pp.24-29
    • /
    • 2012
  • Purpose: To evaluate follow-up after the clinical results of arthroscopic assisted tenodesis of the proximal biceps tendon using an interference screw. Materials and Methods: We reviewed 30 cases of patients receiving tenodesis of the proximal biceps tendon between January, 2008 and January, 2010 who treated with arthroscope. The results were judged by VAS, ASES, tenderness in the biceps groove, fixation failure and the degree of deformity. Results: VAS, ASES scores increased by a statistically significant during the final observation in all patients than before surgery (p<0.05). For those with rotator cuff tear had low ASES results (p<0.05), respectively. But, tenderness in the biceps groove was 17% (5 cases), pepeye deformity and incresead BAD (biceps apex distance) were 10% (3 cases). Conclusion: Arthroscopic tenodesis of the proximal biceps tendon using an interference screw to patients with proximal lesion in their biceps tendon, can achieve good results, but it is possible to groove tenderness and popeye deformity.

  • PDF

Ultrasound-guided Extracorporeal Shock Wave Therapy Combined with Multiple Needling for Calcific Tendinitis in Shoulder (견관절의 석회화 건염에 대한 초음파 유도하 다발성 천공술 및 고에너지 체외 충격파 병합치료)

  • Jung, Tae Wan;Song, Dong Ik;Lee, Soon Hyuck;Jeoung, Woong Kyo
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: To evaluate the effectiveness of ultrasonography-guided combined multiple needling and high-energy extracorporeal shock wave therapy (ESWT) for calcific tendinitis of the shoulder. Materials and Methods: We included 42 calcific tendinitis patients who underwent ultrasonograpy-guided multiple needling followed by high-energy ESWT who visited the clinic from January 2010 to June 2013. The average follow up period was 45 weeks. Clinical evaluation was done before and after 12 weeks from treatment, in clinical terms using pain visual analogue scale (P-VAS), ASES, UCLA scores reflecting performance and symptom improvement, and in sonographic terms by studying the changes in size of the calcific nodules. Results: A statistically significant improvement was seen in P-VAS, ASES, UCLA scores and decreased calcification size on sonographic evaluation. Conclusion: Ultrasonography-guided combined multiple needling and high-energy ESWT is considered as a useful method which could provide clinical function improvement and reduction of calcification deposit.

  • PDF

Clinical Results after Repair of Rotator Cuff Tear in Patients with Accompanying AC Joint Pathology: Clinical Comparison of Non-operative Treatment (회전근개 파열과 동반된 견봉 쇄골 관절 병변이 회전근개 봉합술 후 결과에 미치는 영향: 비수술적 치료를 통한 임상적 비교)

  • Yoo, Moon-Jib;Seo, Joong-Bae;Lee, Dae-Hee;Kim, Sung-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.2
    • /
    • pp.86-90
    • /
    • 2012
  • Purpose: We studied the need for distal clavicle resection by comparing rotator cuff tear patients who underwent non-surgical treatment with and without acromioclavicular joint pathology. Materials and Methods: 45 cases that had been under follow up care for at least 9 months after receiving rotator cuff repair in our hospital between Jan. 2005 and Jun. 2011 had been studied. Acromioclavicular joint pathology group and control group were classified by physical examination and MRI findings. The temporal changes in shoulder joint abduction, internal and external rotation strength, ASES and KSS score of the two groups were measured and analyzed. Results: The acromioclavicular joint pathology complicated rotator cuff injury group's strength measurements for abduction, internal rotation, external rotation were each 8.05 (${\pm}4.54$), 11.33 (${\pm}6.05$), 10.24 (${\pm}5.27$) preoperatively and improved to 13.26 (${\pm}5.50$), 17.51 (${\pm}6.80$), 15.60 (${\pm}5.37$) post operatively while the KSS score and ASES score were each 49.07 (${\pm}15.28$) and 48.65 (${\pm}13.27$) preoperatively, improving to 84.48 (${\pm}10.96$) and 84.65. (${\pm}9.86$). The measurements for the group without complicating acromioclavicular pathology are as follows. The strength for abduction, internal rotation, external rotation was each 6.42 (${\pm}3.11$), 7.59 (${\pm}4.81$) and 7.93 (${\pm}4.49$) preoperatively, improving to 15.85 (${\pm}7.35$), 19.18 (${\pm}9.14$), 16.95 (${\pm}5.70$) post operatively, while the KSS score and ASES score each went from 42.12 (${\pm}6.43$) and 41.37 (${\pm}7.42$) to 83.44 (${\pm}6.30$) and 83.17 (${\pm}7.01$) respectively. The measurements for the two groups, however, did not show a statistically significant difference (p>0.05). Conclusion: Analysis of the rotator cuff injury groups with and without AC joint pathology showed that both groups had improved strength, ASES and KSS scores with no statistical difference difference among the groups. As such, it thought that conservative treatment is an acceptable alternative to distal clavicle resection.

Preparation of Zein Microparticles Using Supercritical Carbon Dioxide (초임계 이산화탄소를 이용한 Zein 미립자 제조)

  • Ryu, Jong-Hoon;Lim, Gio-Bin
    • KSBB Journal
    • /
    • v.27 no.4
    • /
    • pp.237-242
    • /
    • 2012
  • In this study, zein microparticles and drug-loaded zein microparticles were prepared using supercritical ASES technique. The effects of operating parameters on particle size and morphology were investigated. ASES-processed zein microparticles consisted of agglomerates of very fine unit particles. As temperature increased, the size of unit particles increased and their morphology became more spherical. The addition of water to the solvents for zein resulted in the formation of more spherical microparticles. The release characteristics of drug-loaded zein microparticles were also studied.