Optimum Design of Braced Three Dimensional Square Steel Frame Structures Considering Arrangement of Major-minor axis of Column (기둥의 강·연성축을 고려한 브레이싱된 정방형 3차원 강골조 구조물의 최적설계)

  • Kim, Ki-Wook;Park, Moon-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.2
    • /
    • pp.259-267
    • /
    • 2004
  • Most steel frame structures are constructed to one side without considering the arrangement of major-minor axis of column and bracing. This research presents more safety and economic efficiency can be obtained by just rearrangement of major-minor axis. Because most of steel-frame structures are excessively designed with Allowable Stress Design, and it needs to be changed to other specifications. The arrangement of major-minor axis of column is partly referred in AISC-LRFD, but still insufficient. This study compared with the each result from rearrangement of major-minor axis of column, arrangement of bracing, the connecting method of bracing, and consequence with different specifications. Moreover it demonstrated the direction of more economically optimized design.

Open Heart Surgeries in Septuagenarians. (70세이상 환자에서의 개심술)

  • 김형수;이원용;지현근;김응중;홍기우
    • Journal of Chest Surgery
    • /
    • v.32 no.11
    • /
    • pp.1017-1022
    • /
    • 1999
  • Background: An increasing number of elderly are referred for open heart surgeries(OHS). These patients are assumed to have significantly increased morbidity and mortality because of compromised functional reserves in their vital organs. We reviewed the results of OHS patients who were 70 years old or older. Material and Method: Thirty six consecutive septuagenarians underwent OHS from 1995 to 1997. Operations were coronary artery bypass grafting(CABG) in 26 including 3 left main surgical angioplasty, valve replacement in 7, MVR+CABG in 2, and ASD closure+TAP in 1. Statistical tests were carried out to compare survivor group with nonsurvivor group in respect to risk factors including NYHA functional class, LVEF, emergent operation, IABP support, CPB/ACC time, ventilator time cardiac index, ICU stay and hospital stay for operative mortality. Result: Operative mortality rate and postoperative complication were 16%(6/36) and 50%(18/36). One-year and 3-year actuarial survival rates were 76%. Nine patients(25%) had major complications including third-degree A-V block(2), respiratory failure(1), stroke(3), renal failure requiring dialysis(3) and postoperative hemorrhage(2). The causes of death were pneumonia(1), bleeding(1), acute renal failure(1), low cardiac output(1), third-degree A-V block(1), and ventricular tachycardia(1). The univariate analysis of mortality shows that NYHA class IV, LVEF<40%, lesser values for C.I, and longer time for ventilatory support were associated with the risk factors(p value=0.03, 0.001, 0.007, and 0.014). The emergent operation, CPB/ACC time, IABP support, ICU stay and hospital stay were not significant. Conclusion: We conclude that cardiac operation can be performed in septuagenarians with acceptable outcomes when done in patients with normal to moderately depressed left ventricular function and adequate functional reserves in their vital organs.

  • PDF

Predicting Organic Matter content in Korean Soils Using Regression rules on Visible-Near Infrared Diffuse Reflectance Spectra

  • Chun, Hyen-Chung;Hong, Suk-Young;Song, Kwan-Cheol;Kim, Yi-Hyun;Hyun, Byung-Keun;Minasny, Budiman
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.4
    • /
    • pp.497-502
    • /
    • 2012
  • This study investigates the prediction of soil OM on Korean soils using the Visible-Near Infrared (Vis-NIR) spectroscopy. The ASD Field Spec Pro was used to acquire the reflectance of soil samples to visible to near-infrared radiation (350 to 2500 nm). A total of 503 soil samples from 61 Korean soil series were scanned using the instrument and OM was measured using the Walkley and Black method. For data analysis, the spectra were resampled from 500-2450 nm with 4 nm spacing and converted to the $1^{st}$ derivative of absorbance (log (1/R)). Partial least squares regression (PLSR) and regression rules model (Cubist) were applied to predict soil OM. Regression rules model estimates the target value by building conditional rules, and each rule contains a linear expression predicting OM from selected absorbance values. The regression rules model was shown to give a better prediction compared to PLSR. Although the prediction for Andisols had a larger error, soil order was not found to be useful in stratifying the prediction model. The stratification used by Cubist was mainly based on absorbance at wavelengths of 850 and 2320 nm, which corresponds to the organic absorption bands. These results showed that there could be more information on soil properties useful to classify or group OM data from Korean soils. In conclusion, this study shows it is possible to develop good prediction model of OM from Korean soils and provide data to reexamine the existing prediction models for more accurate prediction.

Unidirectional Valve Patch Closure for Ventricular Septal Defect with Severe Pulmonary Hypertension -A case Report - (심한 폐동맥고혈압을 동반한 심실중격결손 환자에서 일방성 판막 팻취를 이용한 교정술 -1례 보고-)

  • 문석환;조건현;장윤희;박성룡;왕영필;김세화;곽문섭;강재걸
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.718-721
    • /
    • 1998
  • The surgical closure of VSD in patient with severe pulmonary hypertension has been considered a difficult problem for surgeons, because sudden hemodynamic change after closure of the defect could bring on high perioperative mortality. Recently, it was reported that UVP(unidirectional valve patch), which allows some blood to flow from right to left in case of acute right heart failure, is effective in improving the postoperative hemodynamics after closing septal defects. This 42-year old woman had suffered from VSD for 20 years and recently complained of worsening exertional dyspnea for three months, and was diagnosed of a large VSD(2.0 cm in diameter) with severe pulmonary hypertension(116/38 mm Hg), equal to systemic arterial pressure. We could successfully close VSD with severe pulmonary hypertension using one UVP and the other UVP for the creative ASD to be prepared against possible acute right heart failure. She was discharged on the fourteenth postoperative day and has been well for twelve months with spontanenous closure of UVP patch at the ninth postopeative month.

  • PDF

Surgical Management for Chronic Atrial Fibrillation (만성 심방세동에 대한 외과적 치험 4례)

  • 강경훈;김철환;김병열
    • Journal of Chest Surgery
    • /
    • v.31 no.1
    • /
    • pp.59-65
    • /
    • 1998
  • Atrial fibrillation is the most common of all cardiac arrhythmias. It is associated with significant morbidity and mortality and is frequently resistant to medical therapy. On the experimental and clinical study, the presence of macroreentrant circuits and the absence of either microreentrant circuits or evidence of atrial automaticity suggests that atrial fibrillation should be amenable to surgical ablation. The results of the maze III procedure are associated with a higher incidence of postoperative sinus rhythm, improved long-term sinus node function, fewer pacemaker requirements, less arrhythmia recurrence, and improved long-term atrial transport function. We had experienced 4 patients with chronic atrial fibrillation. For the first time, Hioki procedure had been performed in the first patient with ASD and atrial fibrillation, regular sinus rhythm showed on postoperative EKG, but junctional rhythm and bradycardia developed postoperative 3 years. The maze III procedure for the rest with mitral valvular disease and atrial fibrillation had been done, followed by regular sinus rhythm for 2 patients and atrial fibrillation for 1 patient, managed with amiodarone, on immediate postoperative state. Echocardiogram documented good contraction of right atrium and hardly contraction of left atrium for 2 patients with regular sinus rhythm postoperative 3 months.

  • PDF

Optimum design of steel space truss towers under seismic effect using Jaya algorithm

  • Artar, Musa;Daloglu, Ayse T.
    • Structural Engineering and Mechanics
    • /
    • v.71 no.1
    • /
    • pp.1-12
    • /
    • 2019
  • This study investigates optimum designs of steel space truss towers under seismic loading by using Jaya optimization algorithm. Turkish Earthquake Code (2007) specifications are applied on optimum designs of steel space truss towers under the seismic loading for different local site classes depending on different soil groups. The proposed novel algorithm does not have any algorithm-specific control parameters and depends only a simple revision equation. Therefore, it provides a practical solution for structural optimization problems. Optimum solutions of the different steel truss examples are carried out by selecting suitable W sections taken from American Institute of Steel Construction (AISC). In order to obtain optimum solutions, a computer program is coded in MATLAB in corporated with SAP2000-OAPI (Open Application Programming Interface). The stress and displacement constraints are applied on the design problems according to AISC-ASD (Allowable Stress Design) specifications. Firstly, a benchmark truss problem is examined to see the efficiency of Jaya optimization algorithm. Then, two different multi-element truss towers previously solved with other methods without seismic loading in literature are designed by the proposed algorithm. The first space tower is a 582-member space truss with the height of 80 m and the second space tower is a 942-member space truss of about 95 m height. The minimum optimum designs obtained with this novel algorithm for the case without seismic loading are lighter than the ones previously attained in the literature studies. The results obtained in the study show that Jaya algorithm is a practical and robust optimization method for structural optimization problems. Moreover, incorporation of the seismic loading causes significant increase in the minimum design weight.

Physical protection system vulnerability assessment of a small nuclear research reactor due to TNT-shaped charge impact on its reinforced concrete wall

  • Moo, Jee Hoon;Chirayath, Sunil S.;Cho, Sung Gook
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2135-2146
    • /
    • 2022
  • A nuclear energy facility is one of the most critical facilities to be safely protected during and after operation because the physical destruction of its barriers by an external attack could release radioactivity into the environment and can cause harmful effects. The barrier walls of nuclear energy facilities should be sufficiently robust to protect essential facilities from external attack or sabotage. Physical protection system (PPS) vulnerability assessment of a typical small nuclear research reactor was carried out by simulating an external attack with a tri-nitro toluene (TNT) shaped charge and results are presented. The reinforced concrete (RC) barrier wall of the research reactor located at a distance of 50 m from a TNT-shaped charge was the target of external attack. For the purpose of the impact assessment of the RC barrier wall, a finite element method (FEM) is utilized to simulate the destruction condition. The study results showed that a hole-size of diameter 342 mm at the front side and 364 mm at the back side was created on the RC barrier wall as a result of a 143.35 kg TNT-shaped charge. This aperture would be large enough to let at least one person can pass through at a time. For the purpose of the PPS vulnerability assessment, an Estimate of Adversary Sequence Interruption (EASI) model was used, which enabled the determination of most vulnerable path to the target with a probability of interruption equal to 0.43. The study showed that the RC barrier wall is vulnerable to a TNT-shaped charge impact, which could in turn reduce the effectiveness of the PPS.

Vibration Analysis of Film Winding Core Automatic Supply System Using US Military Standards (미 군사규격을 적용한 권취 코어 자동공급장치의 진동해석)

  • Go, Jeong-Il;Park, Soo-Hyun;Hur, Jang-Wook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.4
    • /
    • pp.91-99
    • /
    • 2022
  • By applying METHOD 514.8 of the US military standard MIL-STD-810H, vibration analysis of the winding core automatic feeding device was performed during vehicle transportation. The contact point between the LM guide and main support frame was weak in the vertical axis, transverse axis, and longitudinal axis during the transportation of the automatic winding core feeder vehicle, and the maximum equivalent stress was 236.31 MPa in the longitudinal axis. When random vibration was applied, the safety margin in the longitudinal direction was 0.26, indicating low safety. The safety margin was changed by increasing the damage factor to 0.1. Finally, the safety margin was improved to 3.48 to secure safety. Resonance occurred with a Q factor of 9.34 in the harmonic response to which the RMS value of the ASD data was input, and the vertical axis safety margin was derived as 0.16. When the damping factor was 0.15, the Q factor was 3.37, and resonance was avoided with a safety margin of 6.62.

Simultaneous Determination of Five Porphyrins in Human Urine and Plasma Using High Performance Liquid Chromatography-Tandem Mass Spectrometry

  • Hur, Yeoun;Tae, Sookil;Koh, Yun-Joo;Hong, Sung-Hyun;Yoon, Young Ho;Jang, Haejong;Kim, Sooji;Kim, Kyeong Ho;Kang, Seung Woo;Lee, Youngshin;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • v.5 no.2
    • /
    • pp.42-48
    • /
    • 2014
  • A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESI-MS/MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column ($150mm{\times}2.0mm$, $4{\mu}m$) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/v) at a flow rate of $450{\mu}L$/min. Porphyrins and the internal standard (IS), coproporphyrin I-$^{15}N_4$, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.

A Prospective Clinical Trial of Histidine-Tryptophan Ketoglutarate Solution in Congenital Heart Surgery (히스티딘을 함유한 결정성 심정지액(Histidine-Tryptophan Ketoglutarate solution)과 혈성 심정지액을 사용한 선천성 심기형 환자에서의 심근보호 효과에 대한 전향적 비교연구)

  • Lee, Cheul;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.36 no.7
    • /
    • pp.483-488
    • /
    • 2003
  • There are still debates in the literature on the relative benefits of blood cardioplegia and crystalloid cardioplegia in pediatric cardiac surgery. We performed a clinical trial to compare the myocardial protective effect between HTK solution and blood cardioplegic solution in congenital heart surgery. Material and Method: 15 patients who underwent HTK solution cardioplegia (group 1) and 15 patients who underwent blood cardioplegia(group 2) were included in this study. Preoperative and postoperative serial serum cardiac enzyme levels (troponin I, CK-MB, LDH) were measured in all patients. Clinical data were analyzed and compared between the two groups. Result: There were no differences in age and body weight between the two groups. Operative diagnosis included ventricular septal defect (VSD, n=4), atrial septal defect (ASD, n=1), tetralogy of Fallot (TOF, n=4), and other complex heart diseases (n=6) in group 1, VSD (n=7), ASD (n=5), and TOF (n=3) in group 2. Cardiopulmonary bypass times were 99.1$\pm$48.1 minutes in group 1, and 69.3$\pm$27.3 minutes in group 2 (p=0,02). Aortic clamping times were 52.1$\pm$23.6 minutes in group 1, and 37.9$\pm$20.5 minutes in group 2 (p=0.07). There was no mortality and spontaneous defibrillation was possible in all patients. No differences were observed in the serial enzyme levels between the two groups. There were no differences in the duration of inotropic support and ventilator time between the two groups. Conclusion: HTK solution provided comparable myocardial protection compared with blood cardioplegic solution. A single high dose of HTK solution may be safely and conveniently used for an extended periods as well in congenital heart surgery.