• 제목/요약/키워드: ARRHYTHMIA

Search Result 608, Processing Time 0.025 seconds

Relation between Ablation Execution Time and Radiation Exposure Effect in the Treatment of Atrial-fibrillation using Cryo-balloon and 3D Radio-frequency Ablation (냉각 풍선 절제술과 3D 고주파 절제술을 이용한 심방세동 치료 시 절제술 시행 시간과 방사선 피폭 영향과의 연관성)

  • Seo, Young-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.427-434
    • /
    • 2022
  • Atrial fibrillation treatment includes 3D RFCA and Cryo-balloon ablation. Both procedures have in common that they enter after understanding the structure of the heart using angiography equipment. Therefore, there is a disadvantage that the effect of exposure according to the procedure time can be a threat to both the patient and the operator, so this study aims to confirm the relationship between the total ablation time and the effect of radiation exposure. We used follow-up data (retrospective) from 41 patients who underwent coronary angiography and arrhythmia at the same time from March 2019 to July 2022. The range for total ablation time was based on the recorded data from the start to the end of the total ablation. The end point of 3D RFCA was when the ablation was completed for 4 pulmonary veins, and in the case of Cryo-balloon ablation, the data that succeeded in electrical insulation were included. As a result of analyzing the total ablation time, the time taken for Cryo-balloon ablation was 1037.29±103.66 s, which was 2448.61 s faster than 3D RFCA using 3485.9±405.71 s, and was statistically significant. (p<0.05) As a result of analyzing the total fluoroscopy time, the exposure time for 3D RFCA was 2573.75±239.08 s, which was less by 1717.15 s than the exposure time for Cryo-balloon ablation, 4290.9±420.42 s, and was statistically significant. In the case of total area dose product, 3D RFCA was 59.04±13.1 uGy/m2, which was lower than Cryo-balloon ablation 980.6±658.07 uGy/m2 by 921.56 uGy/m2, which was statistically significant. As the insulation time of the Cryo-balloon ablation is shorter than that of the 3D RFCA, the method using the Cryo-balloon ablation is considered to be effective when the patient's condition is not good and a quick procedure is required. However, in patients with permanent Atrial fibrillation, there is a high probability of structural changes in the heart, so it is considered that 3D RFCA is better than Cryo-balloon ablation, which is difficult to manipulate.

Initial Experience of the Emergency Bypass System ($EBS^{(R)}$) for the Patients with Cardiogenic Shock due to an Acute Myocardial Infarction (급성 심근경색으로 인한 심인성 쇼크 환자에 대한 경피적 순환 보조장치($EBS^{(R)}$) 적용의 초기경험)

  • Ryu, Kyoung-Min;Kim, Sam-Hyun;Seo, Pil-Won;Ryu, Jae-Wook;Kim, Seok-Kon;Kim, Young-Hwa;Park, Seong-Sik
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.329-334
    • /
    • 2008
  • Background: Percutaneous cardiopulmonary support. (PCPS) has the potential to rescue patients in cardiogenic shock who might otherwise die. PCPS has been a therapeutic option in a variety of the clinical settings such as for patients with myocardial Infarction, high-risk coronary intervention and postcardiotomy cardiogenic shock, and the PCPS device is easy to install. We report our early experience with PCPS as a life saving procedure in cardiogenic shock patients due to acute myocardial infarction. Material and Method: From January 2005 to December 2006, eight patients in cardiogenic shock with acute myocardial infarction underwent PCPS using the CAPIOX emergency bypass system($EBS^{(R)}$, Terumo, Tokyo, Japan). Uptake cannulae were inserted deep into the femoral vein up to the right atrium and return cannulae were inserted into the femoral artery with Seldinger techniques using 20 and 16-French cannulae, respectively. Simultaneously, autopriming was performed at the $EBS^{(R)}$ circuit. The $EBS^{(R)}$ flow rate was maintained between $2.5{\sim}3.0L/min/m^2$ and anticoagulation was performed using intravenous heparin with an ACT level above 200 seconds. Result: The mean age of patients was $61.1{\pm}14.2$ years (range, 39 to 77 years). Three patients were under control of the $EBS^{(R)}$ before percutaneous coronary intervention (PCI), three patients were under control of the $EBS^{(R)}$ during PCI, one patient was under control of the $EBS^{(R)}$ after PCI, and one patient was under control of the $EBS^{(R)}$ after coronary bypass surgery. The mean support time was $47.5{\pm}27.9$ hours (range, 8 to 76 hours). Five patients (62.5%) could be weaned from the $EBS^{(R)}$ after $53.6{\pm}27.2$ hours. (range, 12 to 68 hours) of support. All of the patients who could successfully be weaned from support were discharged from the hospital. There were three complications: one case of gastrointestinal bleeding and two cases of acute renal failure. Two of the three mortality cases were under cardiac arrest before $EBS^{(R)}$ support, and one patient had an intractable ventricular arrhythmia during the support. All of the discharged patients are still surviving at $16.8{\pm}3.1$ months (range, 12 to 20 months) of follow-up. Conclusion: The use of $EBS^{(R)}$ for cardiogenic shock caused by an acute myocardial infarction could rescue patients who might otherwise have died. Successfully recovered patients after $EBS^{(R)}$ treatment have survived without severe complications. More experience and additional clinical investigations are necessary to elucidate the proper installation timing and management protocol of the $EBS^{(R)}$ in the future.

The Cox-Maze Procedure for Atrial Fibrillation Concomitant with Mitral Valve Disease (승모판막질환에 동반된 심방세동에서 Cox-Maze 술식)

  • Kim, Ki-Bong;Cho, Kwang-Ree;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.31 no.10
    • /
    • pp.939-944
    • /
    • 1998
  • Background: The sugical results of the Cox-Maze procedure (CMP) for lone atrial fibrillation(AF) have proven to be exellent. However, those for AF associated with mitral valve(MV) disease have been reported to be a little inferior. Materials and methods: To assess the efficacy and safety of the CMP as a combined procedure with MV operation, we studied retrospectively our experiences. Between April 1994 and October 1997, we experienced 70 (23 males, 47 females) cases of CMP concomitantly with MV operation. Results: The etiologies of MV disease were rheumatic in 67 and degenerative in 3 cases. The mean duration of AF before sugery was 66$\pm$70 months. Fifteen patients had the past medical history of thromboembolic complications, and left atrial thrombi were identified at operation in 24 patients. Twelve cases were reoperations. Aortic cross clamp (ACC) time was mean 151$\pm$44 minutes, and cardiopulmonary bypass (CPB) time was mean 246$\pm$65 minutes. Concomitant procedures were mitral valve replacement (MVR) in 19, MVR and aortic valve replacement (AVR) in 14, MVR and tricupid annuloplasty (TAP) in 8, MVR with AV repair in 3, MV repair in 11, MVR and coronary artery bypass grafting (CABG) in 2, MVR and AVR and CABG in 1, redo-MVR in 10, redo-MVR and redo-AVR in 2 patients. The rate of hospital mortality was 1.4%(1/70). Perioperative recurrence of AF was seen in 44(62.9%), and atrial tachyarrhythmias in 10(14.3%), low cardiac output syndrome in 4(5.7%), postoperative bleeding that required mediastinal exploration in 4(5.7%) patients. Other complications were acute renal failure in 2, aggravation of preoperative hemiplegia in 1, and transient delirium in 1 patient. We followed up all the survivors for 16.4 months(3-44months) on an average. Sinus rhythm has been restored in 65(94.2%) patients. AF has been controlled by operation alone in 73.9% and operation plus medication in 20.3%. Two patients needed permanent pacemaker implantation; one with sick sinus syndrome, and the other with tachycardia- bradycardia syndrome. Only two patients remained in AF. We followed up our patients with transthoracic echocardiography to assess the atrial contractilities and other cardiac functions. Right atrial contractility could be demonstrated in 92% and left atrial contractility in 53%.We compared our non-redo cases with redo cases. Although the duration of AF was significantly longer in redo cases, there was no differences in ACC time, CPB time, postoperative bleeding amount and sinus conversion rate. Conclusions: In conclusion, the CMP concomitant with MV operation demonstrated a high sinus conversion rate under the acceptable operative risk even in case of reoperation.

  • PDF

A Study on Risk Factors for Early Major Morbidity and Mortality in Multiple-valve Operations (중복판막수술후 조기성적에 영향을 미치는 인자에 관한 연구)

  • 한일용;조용길;황윤호;조광현
    • Journal of Chest Surgery
    • /
    • v.31 no.3
    • /
    • pp.233-241
    • /
    • 1998
  • To define the risk factors affecting the early major morbidity and mortality after multiple- valve operations, the preoperative, intraoperative and postoperative informations were retrospectively collected on 124 consecutive patients undergoing a multiple-valve operation between October 1985 and July 1996 at the department of Thoracic and Cardiovascular Surgery of Pusan Paik Hospital. The study population consists of 53 men and 71 women whose mean age was 37.9$\pm$11.5(mean$\pm$SD) years. Using the New York Heart Association(NYHA) classification, 41 patients(33.1%) were in functional class II, 60(48.4%) in class III, and 20(16.1%) in class IV preoperatively. Seven patients(5.6%) had undergone previous cardiac operations. Atrial fibrillations were present in 76 patients(61.3%), a history of cerebral embolism in 5(4.0%), and left atrial thrombus in 13(10.5%). The overall early mortality rate and postoperative morbidity was 8.1% and 21.8% respectively. Among the 124 cases of multiple-valve operation, there were 57(46.0%) of combined mitral valve replacement(MVR) and aortic valve replacement(AVR), 48(38.7%) of combined MVR and tricuspid annuloplasty(TVA), 12(9.7%) of combined MVR, AVR and TVA, 3(2.4%) of combined MVR and aortic valvuloplasty, 2(1.6%) of combined MVR and tricuspid valve replacement, and others. The patients were classified according to the postoperative outcomes; Group A(27 cases) included the patients who had early death or major morbidity such as low cardiac output syndrome, mediastinitis, cardiac rupture, ventricular arrhythmia, sepsis, and others; Group B(97 cases) included the patients who had the good postoperative outcomes. The patients were also classified into group of early death and survivor. In comparison of group A and group B, there were significant differences in aortic cross-clamping time(ACT, group A:153.4$\pm$42.4 minutes, group B:134.0$\pm$43.7 minutes, p=0.042), total bypass time(TBT, group A:187.4$\pm$65.5 minutes, group B:158.1$\pm$50.6 minutes, p=0.038), and NYHA functional class(I:33.3%, II:9.7%, III:20%, IV:50%, p=0.004). In comparison of early death(n=10) and survivor(n=114), there were significant differences in age(early death:45.2$\pm$8.7 years, survivor:37.2$\pm$11.6 years, p=0.036), sex(female:12.7%, male:1.9%, p=0.043), ACT(early death:167.1$\pm$38.4 minutes, survivor:135.7$\pm$43.7 minutes, p=0.030), and NYHA functional class(I:0%, II:4.9%, III:1.7%, IV:35%, p=0.001). In conclusion, the early major morbidity and mortality were influenced by the preoperative clinical status and therefore the earlier surgical intervention should be recommended whenever possible. Also, improved methods of myocardial protection and operative techniques may reduce the risk in patients with multiple-valve operation.

  • PDF

The Comparative Study of on Pump CABG during Pulsatile $(T-PLS^{TM})$ and Nonpulsatile $(Bio-pump^{TM})$ Perfusion (관상동맥우회술 시 사용된 박동성펌프$(T-PLS^{TM})$와 비박동성펌프$(Bio-pump^{TM})$의 비교연구)

  • Park Young-Woo;Her Keun;Lim Jae-Ung;Shin Hwa-Kyun;Won Yong-Soon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.354-358
    • /
    • 2006
  • Background: Pulsatile pumps for extracorporeal circulation have been known to be better for tissue perfusion than non-pulsatile pumps but be detrimental to blood corpuscles. This study is intended to examine the risks and benefits of $T-PLS^{TM}$ through the comparison of clinical effects of $T-PLS^{TM}$ (pulsatile pump) and $Bio-pump^{TM}$ (non-pulsatile pump) used for coronary bypass surgery. Material and Method: The comparison was made on 40 patients who had coronary bypass using $T-PLS^{TM}\;and\;Bio-pump^{TM}$ (20 patients for each) from April 2003 to June 2005. All of the surgeries were operated on pump beating coronary artery bypass graft using cardiopulmonary extra-corporeal circulation. Risk factors before surgery and the condition during surgery and the results were compared. Result: There was no significant difference in age, gender ratio, and risk factors before surgery such as history of diabetes, hypertension, smoking, obstructive pulmonary disease, coronary infarction, and renal failure between the two groups. Surgery duration, hours of heart-lung machine operation, used shunt and grafted coronary branch were little different between the two groups. The two groups had a similar level of systolic arterial pressure, diastolic arterial pressure and mean arterial pressure, but pulse pressure was measured higher in the group with $T-PLS^{TM}\;(46{\pm}15\;mmHg\;in\;T-PLS^{TM}\;vs\;35{\pm}13\;mmHg\;in\;Bio-pump^{TM},\;p<0.05)$. The $T-PLS^{TM}$-operated patients tended to produce more urine volume during surgery, but the difference was not statistically significant $(9.7{\pm}3.9\;cc/min\;in\;T-PLS^{TM}\;vs\;8.9{\pm}3.6\;cc/min\;in\;Bio-pump^{TM},\;p=0.20)$. There was no significant difference in mean duration of respirator usage and 24-hour blood loss after surgery between the two groups. Plasma free Hb was measured lower in the group with $T-PLS^{TM}\;(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;versus\;46.8{\pm}23.0mg/dL\;in\;Bio-pump^{TM},\;p<0.05)$. There was no significant difference in coronary infarction, arrhythmia, renal failure and morbidity rate of cerebrovascular disease. There was a case of death after surgery (death rate of 5%) in the group tested with $T-PLS^{TM}$, but the death rate was not statistically significant. Conclusion: Coronary bypass was operated with $T-PLS^{TM}$ (Pulsatile flow pump) using a heart-lung machine. There was no unexpected event caused by mechanical error during surgery, and the clinical process of the surgery was the same as the surgery for which $Bio-pump^{TM}$ was used. In addition, $T-PLS^{TM}$ used surgery was found to be less detrimental to blood corpuscles than the pulsatile flow has been known to be. Authors of this study could confirm the safety of $T-PLS^{TM}$.

Mid-Term Results of 292 cases of Coronary Artery Bypass Grafting (관상동맥 우회술 292례의 중기 성적)

  • 김태윤;김응중;이원용;지현근;신윤철;김건일
    • Journal of Chest Surgery
    • /
    • v.35 no.9
    • /
    • pp.643-652
    • /
    • 2002
  • As the prevalence of coronay artery disease is increasing, the surgical treatment has been universalized and operative outcome has been improved. We analyzed the short and mid-term results of 292 CABGs performed in Kangdong Sacred Heart Hospital. Material and Method: From June 1994 to December 2001, 292 patients underwent coronary artery bypass grafting. There were 173 men and 119 women and their ages ranged from 39 to 84 years with a mean of $61.8{\pm}9.1$ years. We analyzed the preoperative risk factors, operative procedures and operative outcome. In addition, we analyzed the recurrence of symptoms, long-term mortality and complications via out-patient follow-up for discharged patients. Result: Preoperative clinical diagnoses were unstable angina in 137(46.9%), stable angina in 34(11.6%), acute myocardial infarction in 40(13.7%), non-Q myocardial infarction in 25(8.6%), postinfarction angina in 22(7.5%), cardiogenic shock in 30(10.3%) and PTCA failure in 4(1.4%) patients. Preoperative angiographic diagnoses were three-vessel disease in 157(53.8%), two-vessel disease in 35 (12.0%), one-vessel disease in 11(3.8%) and left main disease in 89(30.5%) patients. We used saphenous veins in 630, internal thoracic arteries in 257, radial arteries in 50, and right gastoepiploic arteries in 2 distal anastomoses. The mean number of distal anastomoses per patient was $3.2{\pm}1.0$ There were 18 concomitant procedures ; valve replacement in 8(2.7%), left main coronary artery angioplasty in 6(2.1%), patch closure of postinfarction ventricular septal defect(PMI-VSD) in 2(0.7%), replacement of ascending aorta in 1(0.3%) and coronary endarterectomy in 1(0.3%) patient. The mean ACC time was $96.6{\pm}35.3 $ minutes and the mean CPB time was $179.2{\pm}94.6$ minutes. Total early mortality was 8.6%, but it was 3.1% in elective operations. The most common cause of early mortality was low cardiac output syndrome in 6(2.1%) patients. The stastistically significant risk factors for early mortality were hypertension, old age($\geq$ 70 years), poor LV function(EF<40%), congestive heart failure, preoperative intraaortic balloon pump, emergency operation and chronic renal failure. The most common complication was arrhythmia in 52(17.8%) patients. The mean follow-up period was $39.0{\pm}27.0$ months. Most patients were free of symptoms during follow-up. Fourteen patients(5.8 %) had recurrent symptoms and 7 patients(2.9%) died during follow-up period. Follow-up coronary angiography was performed in 13 patients with recurrent symptoms and they were managed by surgical and medical treatment according to the coronary angiographic result. Conclusion: The operative and late results of CABG in our hospital, was acceptable. However, There should be more refinement in operative technique and postoperative management to improve the results.

Effect of Bronchial Artery Embolization(BAE) in Management of Massive Hemoptysis (대량 객혈환자에서 기관지 동맥색전술의 효과)

  • Yeo, Dong-Seung;Lee, Suk-Young;Hyun, Dae-Seong;Lee, Sang-Haak;Kim, Seok-Chan;Choi, Young-Mee;Suh, Ji-Won;Ahn, Joong-Hyun;Song, So-Hyang;Kim, Chi-Hong;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak;Kim, Ki-Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.1
    • /
    • pp.53-64
    • /
    • 1999
  • Background : Massive and untreated hemoptysis is associated with a mortality of greater than 50 percent. Since the bleeding is from a bronchial arterial source in the vast majority of patients, embolization of the bronchial arteries(BAE) has become an accepted treatment in the management of massive hemoptysis because it achieves immediate control of bleeding in 75 to 90 percent of the patients. Methods: Between 1990 and 1996, we treated 146 patients with hemoptysis by bronchial artery embolization. Catheters(4, 5, or 7F) and gelfoam, ivalon, and/or microcoil were used for embolization. Results: Pulmonary tuberculosis and related disorders were the most common underlying disease of hemoptysis(72.6%). Immediate success rate to control bleeding within 24hours was 95%, and recurrence rate was 24.7%. The recurrence rate occured within 6 months after embolization was 63.9%. Initial angiographic findings such as bilaterality, systemic-pulmonary artery shunt, neovascularity, aneurysm were not statistically correlated with rebleeding tendency(P>0.05). Among Initial radiographic findings, only pleural lesions were significantly correlated with rebleeding tendency(P<0.05). At additional bronchial artery angiograpy done due to rebleeding, recanalization of previous embolized arteries were 63.9%, and the presence of new feeding arteries were 16.7%, and 19.4% of patients with rebleeding showed both The complications such as fever, chest pain, headache, nausea and vomiting, arrhythmia, paralylytic ileus, transient sensory loss (lower extremities), hypotension, urination difficulty were noticed at 40 patients(27.4%). Conclusion: We conclude that bronchial artery embolization is relatively safe method achieving immediate control of massive hemoptysis. At initial angiographic findings, we could not find any predictive factors for subsequent rebleeding. It may warrant further study whether patients with pleural disease have definetely increased rebleeding tendency.

  • PDF

The Influence of Obstructive Sleep Apnea on Systemic Blood Pressure, Cardiac Rhythm and the Changes of Urinary (폐쇄성 수면 무호흡이 전신성 혈압, 심조율 및 요 Catecholamines 농도 변화에 미치는 영향)

  • Lo, Dae-Keun;Choi, Young-Mee;Song, Jeong-Sup;Park, Sung-Hak;Moon, Hwa-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.153-168
    • /
    • 1998
  • Background: The existing data indicate that obstructive sleep apnea syndrome contributes to the development of cardiovascular dysfunction such as systemic hypertension and cardiac arrhythmias, and the cardiovascular dysfunction has a major effect on high long-term mortality rate in obstructive sleep apnea syndrome patients. To a large extent the various studies have helped to clarify the pathophysiology of obstructive sleep apnea, but many basic questions still remain unanswered. Methods: In this study, the influence of obstructive sleep apnea on systemic blood pressure, cardiac rhythm and urinary catecholamines concentration was evaluated. Over-night polysomnography, 24-hour ambulatory blood pressure and ECG monitoring, and measurement of urinary catecholamines, norepinephrine (UNE) and epinephrine (UEP), during waking and sleep were undertaken in obstructive sleep apnea syndrome patients group (OSAS, n=29) and control group (Control, n=25). Results: 1) In OSAS and Control, UNE and UEP concentrations during sleep were significantly lower than during waking (P<0.01). In UNE concentrations during sleep, OSAS showed higher levels compare to Control (P<0.05). 2) In OSAS, there was a increasing tendency of the number of non-dipper of nocturnal blood pressure compare to Control (P=0.089). 3) In both group (n=54), mean systolic blood pressure during waking and sleep showed significant correlation with polysomnographic data including apnea index (AI), apnea-hypopnea index (AHI), arterial oxygen saturation nadir ($SaO_2$ nadir) and degree of oxygen desaturation (DOD). And UNE concentrations during sleep were correlated with AI, AHI, $SaO_2$ nadir, DOD and mean diastolic blood pressure during sleep. 4) In OSAS with AI>20 (n==14), there was a significant difference of heart rates before, during and after apneic events (P<0.01), and these changes of heart rates were correlated with the duration of apnea (P<0.01). The difference of heart rates between apneic and postapneic period (${\Delta}HR$) was significantly correlated with the difference of arterial oxygen saturation between before and after apneic event (${\Delta}SaO_2$) (r=0.223, P<0.001). 5) There was no significant difference in the incidence of cardiac arrhythmias between OSAS and Control In Control, the incidence of ventricular ectopy during sleep was significantly lower than during waking. But in OSAS, there was no difference between during waking and sleep. Conclusion : These results suggested that recurrent hypoxia and arousals from sleep in patients with obstructive sleep apnea syndrome may increase sympathetic nervous system activity, and recurrent hypoxia and increased sympathetic nervous system activity could contribute to the development of cardiovascular dysfunction including the changes of systemic blood pressure and cardiac function.

  • PDF