• Title/Summary/Keyword: ARRAY

Search Result 9,377, Processing Time 0.034 seconds

The Crosshole Resistivity Method Using the Mixed Array (혼합배열을 사용하는 시추공간 전기비저항 탐사)

  • Cho In-Ky;Han Sung-Hoon;Kim Ki-Ju
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.250-256
    • /
    • 2002
  • Resistivity tomography has become an important tool to image underground resistivity distribution. This method has been widely applied to site investigation for engineering and environmental purpose. In resistivity tomography, various electrode arrays can be used and each array has both merits and demerits. For example, the pole-pole array has high signal to noise ratio (S/N ratio), but its resolution is too low. The dipole-dipole array has low S/N ratio, but its resolution is very high. The Pole-dipole may has intermediate Snf ratio and resolution. The modified Pole-dipole array, recently proposed, shows reasonable S/N ratio and resolution, which are comparable to the pole-dipole array. These electrode arrays except the pole-pole array, however, have the problem that the apparent resistivity can diverge at some special electrode Positions. Also, the Pole-Pole array may not reflect the doe resistivity of an anomalous body. In this study, we propose a new electrode array, mixed array, where pole-dipole and modified pole-dipole ways are selectively used with the relative positions of current and potential electrodes. The mixed array has the same level of S/N ratio and resolution as the pole-dipole array and the apparent resistivity does not diverge in the receiver hole. Furthermore, the apparent resistivity using the array can reflect the true resistivity of the anomalous body.

Effect of the Patch Width on the Radiation Characteristics of a Pin Array Patch Antenna (패치의 폭이 핀 배열 패치 안테나의 방사 특성에 미치는 효과)

  • Yoon, Young-Min;Kim, Tae-Young;Cho, Myung-Ki;Kim, Boo-Gyoun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.1
    • /
    • pp.77-83
    • /
    • 2010
  • Radiation characteristics of $5{\times}4$ pin array patch antennas are compared to those of $5{\times}2$ pin array patch antennas for several substrate thicknesses using the computer simulation. Since the number of unit cells of a $5{\times}2$ pin array patch antenna is half of that of a $5{\times}4$ pin array patch antenna, the number of pins used in a $5{\times}2$ pin array patch antenna is half of that in a $5{\times}4$ pin array patch antenna and the patch width of a $5{\times}2$ pin array patch antenna is very small compared to that of a $5{\times}4$ pin array patch antenna. However, the radiation characteristics of a $5{\times}2$ pin array patch antenna are almost similar to those of a $5{\times}4$ pin array patch antenna.

Source Localization Based on Independent Doublet Array (독립적인 센서쌍 배열에 기반한 음원 위치추정 기법)

  • Choi, Young Doo;Lee, Ho Jin;Yoon, Kyung Sik;Lee, Kyun Kyung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.164-170
    • /
    • 2014
  • A single near-field sounde source bearing and ranging method based on a independent doublet array is proposed. In the common case of bearing estimation method, unform linear array or uniform circular array are used. It is constrained retaining aperture because of array structure to estimate the distance of the sound source. Recent using independent doublet array sound source's bearing and distance esmtimation method is proposed by wide aperture. It is limited to the case doublets are located on a straight line. In this paper, we generalize the case and estimate the localization of a sound source in the various array structure. The proposed algorithm was verified performance through simulation.

The Study on Reliability Improvement in Eddy Current Inspection by Signal Characteristic Optimization of Multi-coil Array Probe (다중센서 신호특성 최적화를 통한 와전류검사 신뢰성 개선연구)

  • Ahn, Y.S.;Gil, D.S.;Park, S.G.
    • Journal of Power System Engineering
    • /
    • v.14 no.2
    • /
    • pp.60-64
    • /
    • 2010
  • This paper introduces reliability improvement and time saving in eddy current inspection by signal characteristic optimization of multi-coil eddy current array probe. In the past, Multi-coil array probe and single probe were used for the gas turbine rotor surface inspection & defect evaluation. The multi-coil array probe was used for the broad area inspection. But the signal deviations among multi-coil array probe are maximum 28% in commercial probe. This differences were considered to impedance differences among coils, so it is very difficult to evaluate exact defect size. The signal deviations among multi-coil array probe are maximum 28% in commercial probe. So, single coil inspection was used for exact defect sizing. The purpose of this study is to improve signal deviations of multi-coil array probe. The introduced new technology can improves this deviation by adjusting input voltage in each coil. At first, apply same voltage in each coil and collect signal amplitude of each coil. And calculate new input voltage based on signal amplitude of each coil. If the signal amplitude deviation is within 5% among multi-coil array probe, the signal amplitude of multi-coil array probe is reliable. The proposed technology gives 2% signal deviation among multi-coil array probe. The proposed new technology gives reliability improvement and inspection time saving in eddy current inspection.

All Flash Array Storage Virtualisation using SCST (SCST를 이용한 All Flash Array 스토리지 가상화)

  • Heo, Huiseong;Pirahandeh, Mehdi;Lee, Kwangsoo;Kim, Deokhwan
    • KIISE Transactions on Computing Practices
    • /
    • v.20 no.10
    • /
    • pp.525-533
    • /
    • 2014
  • SCST(The generic SCSI target subsystem for Linux) enables developers to make SCSI target storage and supports various SCSI network protocol such as iSCSI, FC, SRP. In this paper, we propose storage virtualization method using SCST and virtualize all flash array as high performance storage through 4Gb Fiber Channel, 10Gb Ethernet and 40Gb Infiniband and evaluate their performance, respectively. Experimental result shows that 40Gb infiniband network appliance have better performance than others. In case of sequential/random read, 40Gb infiniband network appliance shows 78% and 79% of local all flash array performance attached to SCSI target system. In case of sequential/random write, it shows 83% and 88% of local flash array performance attached to SCSI target system.

Investigations of Faults using array CSAMT Method (단층조사를 위한 array CSAMT 적용사례)

  • Lee Sang Kyu;Hwang Se Ho;Lee Dong Young;Lee Jin-Soo;Hwang Hak Soo;Park In Hwa
    • Geophysics and Geophysical Exploration
    • /
    • v.1 no.2
    • /
    • pp.92-100
    • /
    • 1998
  • Array CSAMT surveys were conducted in two areas where it was not easy to identify the presence of faults only with geological survey because of thick overburden. The purpose of these surveys were to locate the faults and to delineate the deep resistivity structures around the faults. The steep dip lineaments having high contrast in resistivity laterally and the low resistive zones having some width in the resistivity sections were interpreted as faults and fracture zones associated with faults, respectively, The good applicability of array CSAMT to the investigation of fault was recognized owing to the agreement between the interpretation results of array CSAMT and the conclusive evidences collected by the following geological survey. The evidences includes the recent exposure of fault and the trajectory of fault evidences of the survey line. A comparison of the applicabilities of array CSAMT method and the resistivity method using dipole-dipole array was presented with the results of both methods along a same traverse line.

  • PDF

A Quarter-Wavelength Open Circuited Microstripline Slot Array ($\lambda$g/4 개방 마이크로스트립 선로 스로트의 배열)

  • 배정이
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.19 no.6
    • /
    • pp.80-83
    • /
    • 1982
  • A quarter-wavelength open circuited microstripline slot array is realized at X-band froquency. The optimal feeding point is experimentally determined. The input impedance of the slot array for various frequencies and its radiation pattern are measured. The bandwidth of the slot array is increased by using the 4$\times$4 elements which are slightly different in length and feeding network which is suggested in this papers.

  • PDF

Local Heat Transfer Characteristics of Array Impinging Jets with Channel flow on the Concave Surface (채널유동성분이 존재하는 오목 충돌면에서 배열충돌제트에 의한 국소 열전달 특성 고찰)

  • Lee, Won-Hee;Hwang, Sang-Dong;Cho, Hyung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1098-1103
    • /
    • 2004
  • In this study, the effect of channel flow in the concave surface on local heat transfer characteristics of array jets was investigated experimentally. A TLC method is employed to determine local heat transfer coefficients on the target plate and also flow visualization has been conducted to investigate the behavior of a row of impinging jets and array of impinging jets. Two different array patterns of impinging array jets devices are tested for Reynolds number(Re=10,000). In a row of impinging jets, secondary vortex is strongly maintained by main vortex at nozzle-to-plate distance of H/d=2. Therefore, the Nusselt number slowly decreased at the mid-way region between adjacent jets. In array jets, the local maximum Nusselt number region move further in the downstream direction due to the increase of channel flow velocity.

  • PDF

FLUID-ELASTIC INSTABILITY OF ROTATED SQUARE TUBE ARRAY IN AN AIR-WATER TWO-PHASE CROSSFLOW

  • CHUNG HEUNG JUNE;CHU IN-CHEOL
    • Nuclear Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.69-80
    • /
    • 2006
  • Fluid-elastic instability in an air-water two-phase cross-flow has been experimentally investigated using two different arrays of straight tube bundles: normal square (NS) array and rotated square (RS) array tube bundles with the same pitch-to-diameter ratio of 1.633. Experiments have been performed over wide ranges of mass flux and void fraction. The quantitative tube vibration displacement was measured using a pair of strain gages and the detailed orbit of the tube motion was analyzed from high-speed video recordings. The present study provides the flow pattern, detailed tube vibration response, damping ratio, hydrodynamic mass, and the fluid-elastic instability for each tube bundle. Tube vibration characteristics of the RS array tube bundle in the two-phase flow condition were quite different from those of the NS array tube bundle with respect to the vortex shedding induced vibration and the shape of the oval orbit of the tube motion at the fluid-elastic instability as well as the fluid-elastic instability constant.

Implementation of systolic array for 2-D IIR digital filters (2-D IIR digital filter에 대한 systolic array구현)

  • 김수현
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1992.06a
    • /
    • pp.29-32
    • /
    • 1992
  • In this paper, a systolic array structure is derived from the realization of 2-D IIR digital filters directed from the SFG(signal flow graph). After realized the 1-D formed partial systolic array, we implemented the complete systolic array to be cascaded 1-D form. The cascading of partial systolic arrays reduce the storage element which sued to delay input signal. 1-D systolic array is derived from that DG is designed through local communication approach and then it mapping to SFG. The derived structure is very simple and has high throughput because during new imput sample is supplied, new output is obtained every sampling period. And broadcast input signal is eliminated. Since the systolic array has property of regularity, modularity, local interconnection and highly synchronized multiprocessing, thus is very suitable for VLSI implementation.

  • PDF