• Title/Summary/Keyword: ARGUS system

Search Result 14, Processing Time 0.03 seconds

Evaluation of Cardiac Function Analysis System Using Magnetic Resonance Images

  • Tae, Ki-Sik;Suh, Tae-Suk;Choe, Bo-Young;Lee, Hyoung-Koo;Shinn, Kyung-Sub;Jung, Seung-Eun;Lee, Jae-Moon
    • Progress in Medical Physics
    • /
    • v.10 no.3
    • /
    • pp.159-168
    • /
    • 1999
  • Cardiac disease is one of the leading causes of death in Korea. In quantitative analysis of cardiac function and morphological information by three-dimensional reconstruction of magnetic resonance images, left ventricle provides an important role functionally and physiologically. However, existing procedures mostly rely on the extensive human interaction and are seldom evaluated on clinical applications. In this study, we developed a system which could perform automatic extraction of enpicardial and endocardial contour and analysis of cardiac function to evaluate reliability and stability of each system comparing with the result of ARGUS system offered 1.5T Siemens MRI system and manual method performed by clinicians. For various aspects, we investigated reliability of each system by compared with left ventricular contour, end-diastolic volume (EDV), end-systolic volume (ESV), stock volume (SV), ejection fraction (EF), cardiac output (CO) and wall thickness (WT). When comparing with manual method, extracted results of developed process using minimum error threshold (MET) method that automatically extracts contour from cardiac MR images and ARGUS system were demonstrated as successful rate 90% of the contour extraction. When calculating cardiac function parameters using MET and comparing with using correlation coefficients analysis method, the process extracts endocardial and epicardial contour using MET, values from automatic and ARGUS method agreed with manual values within :t 3% average error. It was successfully demonstrated that automatic method using threshold technique could provide high potential for assessing of each parameters with relatively high reliability compared with manual method. In this study, the method developed in this study could reduce processing time compared with ARGUS and manual method due to a simple threshold technique. This method is useful for diagnosis of cardiac disease, simulating physiological function and amount of blood flow of left ventricle. In addition, this method could be valuable in developing automatic systems in order to apply to other deformable image models.

  • PDF

Development of an automated appendix generation system (ARGUS) for clinical study reports

  • Jang, Doo yeon;Han, Seunghoon;Yim, Dong-Seok
    • Proceeding of EDISON Challenge
    • /
    • 2017.03a
    • /
    • pp.672-676
    • /
    • 2017
  • 데이터 처리 및 도표화는 임상 연구 보고서에 부록을 작성할 때 시간 소모적인 작업이다. 저자는 SAS (버전 9.3) 및 R (버전 3.3.1: PK 플롯 생성 용)을 사용하여 CDISC/SDTM 표준에 부합하는 자동 부록 생성 시스템 (ARGUS)을 개발했다. 이 시스템은 하나의 주 프로그램과 세 개의 서브 프로그램으로 구성되어 있다. 일반적인 데스크탑 환경에서 제출 버튼을 누른 후 약 1 분 만에 데이터베이스 파일을 MS Word 형식의 부록 문서로 변환한다. ARGUS 시스템을 사용하여 약 8일간 팀을 구성한 부록을 작성하던 작업이 6~7 시간 내에 완료되었다.

  • PDF

Isolation of a Novel Neuropeptide with Contractile Activity on the Smooth Muscle from the Snakehead Channa argus (가물치(Channa argus)로부터 평활근 수축활성 펩타이드의 정제)

  • Go, Hye-Jin;Park, Nam-Gyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.45 no.2
    • /
    • pp.114-121
    • /
    • 2012
  • A novel neuropeptide was isolated from the skin of the snakehead Channa argus using the dorsal retractor muscle (DRM) of a starfish Asterina pectinifera as a bioassay system. The amino acid sequence of the purified peptide was analyzed using automated sequencing and MALDI-TOF mass spectrophotometry. The primary structure of the purified peptide was determined to be Pro-Ala-Leu-Ala-Leu. To investigate the complete primary structure of this peptide, Pro- Ala-Leu-Ala-Leu-OH and Pro-Ala-Leu-Ala-Leu-NH2 were synthesized. The chemical and pharmacological properties of the synthetic peptides were compared with those of the native peptide. Both the native peptide and synthetic Pro-Ala- Leu-Ala-Leu-OH had identical behaviors on the reverse-phase and cation-exchange HPLC chromatograms. Synthetic Pro-Ala-Leu-Ala-Leu-OH showed contractile activity on the DRM, and the threshold concentration of this peptide was approximately $10^{-8}$ M. The maximal contractile effect ($E_{max}$) of this peptide was $294{\pm}45.4$% at $10^{-5}$ M.

Development and Performance Evaluation of an Animal SPECT System Using Philips ARGUS Gamma Camera and Pinhole Collimator (Philips ARGUS 감마카메라와 바늘구멍조준기를 이용한 소동물 SPECT 시스템의 개발 및 성능 평가)

  • Kim, Joong-Hyun;Lee, Jae-Sung;Kim, Jin-Su;Lee, Byeong-Il;Kim, Soo-Mee;Choung, In-Soon;Kim, Yu-Kyeong;Lee, Won-Woo;Kim, Sang-Eun;Chung, June-Key;Lee, Myung-Chul;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.445-455
    • /
    • 2005
  • Purpose: We developed an animal SPECT system using clinical Philips ARGUS scintillation camera and pinhole collimator with specially manufactured small apertures. In this study, we evaluated the physical characteristics of this system and biological feasibility for animal experiments. Materials and Methods: Rotating station for small animals using a step motor and operating software were developed. Pinhole inserts with small apertures (diameter of 0.5, 1.0, and 2.0 mm) were manufactured and physical parameters including planar spatial resolution and sensitivity and reconstructed resolution were measured for some apertures. In order to measure the size of the usable field of view according to the distance from the focal point, manufactured multiple line sources separated with the same distance were scanned and numbers of lines within the field of view were counted. Using a Tc-99m line source with 0.5 mm diameter and 12 mm length placed in the exact center of field of view, planar spatial resolution according to the distance was measured. Calibration factor to obtain FWHM values in 'mm' unit was calculated from the planar image of two separated line sources. Te-99m point source with i mm diameter was used for the measurement of system sensitivity. In addition, SPECT data of micro phantom with cold and hot line inserts and rat brain after intravenous injection of [I-123]FP-CIT were acquired and reconstructed using filtered back protection reconstruction algorithm for pinhole collimator. Results: Size of usable field of view was proportional to the distance from the focal point and their relationship could be fitted into a linear equation (y=1.4x+0.5, x: distance). System sensitivity and planar spatial resolution at 3 cm measured using 1.0 mm aperture was 71 cps/MBq and 1.24 mm, respectively. In the SPECT image of rat brain with [I-123]FP-CIT acquired using 1.0 mm aperture, the distribution of dopamine transporter in the striatum was well identified in each hemisphere. Conclusion: We verified that this new animal SPECT system with the Phlilps ARGUS scanner and small apertures had sufficient performance for small animal imaging.

A Study on the classification scheme for the design of Directory Search Engine on the web (web 데이터베이스의 디렉토리 설계를 위한 분류체계 연구)

  • 이명희
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.10 no.1
    • /
    • pp.243-268
    • /
    • 1999
  • The purpose of this study is to develop the classification scheme in subject-based directory search engine for educational research information on the web. Five classification systems. Yahoo Korea, Argus Clearinghouse, DDC, ERIC thesaurus and KEDI thesaurus were measured in terms of coverage of subject fields, system logic, accuracy of terminology and efficiency of searching. For the design of Classification Scheme, this study considered the content of subject areas, features of information resources and efficiency based on users. Finally, the Classification Scheme was established in terms of 16 main divisions and 47 sub-divisions in educational research information.

  • PDF

Effect of the Piling Work Noise on the Behavior of Snakehead (Channa argus) in the Aquafarm (양식 가물치 (Channa argus)의 행동에 미치는 파일작업 소음의 영향에 관한 연구)

  • SHIN Hyeon Ok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.4
    • /
    • pp.492-502
    • /
    • 1995
  • This paper describes the relationship between the behavior of the snakehead ( Channa arps) of 44cm long and the environmental noise levels due to the piling work. The experiment is conducted in the aquafarm located near Asan lake, Pyongtaek in 1993. The fish trajectory is obtained by a biotelemetry system in which a pulsed ultrasonic pinger attached onto the dorsal is tracked three dimensionally, and the noise and the vibration levels both in air and in water are measured. The results of this study are as follows: 1) The noise levels in water and in air and the vibration level measured at a distance of 90m from the noise source, increased by 36.5dB $(re\;l{\mu}Pa)$, 2308$(re\;0.0002{\mu}bar)$ and $5.9{\mu}m$ repectively compared to the levers before piling. 2) The highest variation of the swimming speed was observed right after the piling works and the width of variation decreased with the elapsed time. The average speeds of the fish before and during the works were measured as 0.8 times and 1.1 times of the body length, respectively. 3) It is found that the fish escapes into the mud of the aquafarm when a heavy shock wave occurred. Consequently, the heavy shock by the piling works could produce a considerably unfavorable effect to the fish.

  • PDF

Compensation Design to Reduce Springback in Sheet Metal Forming of 1.2GPa Ultra High Strength Steel (1.2GPa급 강판 판재 성형에서 스프링백 감소를 위한 금형 보상 설계)

  • Kwon, S.H.;Lee, H.S.;Lee, Y.S.;Kim, S.W.;Jung, C.Y.;Hong, S.
    • Transactions of Materials Processing
    • /
    • v.25 no.5
    • /
    • pp.301-305
    • /
    • 2016
  • The manual modification of stamping die has widely been used in order to reduce springback after sheet metal forming. When UHSS (Ultra High Strength Steel) is used in sheet metal forming, the die design considering springback compensation is more difficult because higher strength sheet has more springback. In this study, the optimization method was used in order to design die geometry considering springback compensation after forming of 1.2GPa UHSS. Die geometries were defined as design variables and the springback distance from the die surface was conducted as object function in optimization process. The optimized die geometry considering springback compensation was performed using finite element and optimization analysis. The simulation results such as thickness distribution and springback amount were compared with measured data using 3D optical measurement system (GOM ARGUS, ATOS). And the prediction of springback amount showed a good agreement within test results.

Surface Quality of Products according to the Material and Coating Condition of the Forming Tool in Incremental Sheet Forming (점진성형공구 코팅처리 및 소재에 따른 성형품 표면품질 분석)

  • H. W. Youn;N. Park
    • Transactions of Materials Processing
    • /
    • v.32 no.6
    • /
    • pp.360-366
    • /
    • 2023
  • This study is concerned with the surface quality of products according to the material and coating condition of the forming tool in incremental sheet forming. Three forming tools, SKD11 with and without diamond-like-coating (DLC) and polymer tool tip, were used to form conical and pyramidal geometries to take into account the influence of friction between the forming tool and the sheet on the surface quality including geometric accuracy of deformed samples. Each test was performed using SUS304 with a thickness of 0.4 mm according to different incremental depths per lap of 0.5 mm, 1.0 mm, and 1.5 mm for the contour tool path, considering the increase in normal force which is associated with the frictional behavior during local deformation. The surface quality was then investigated through surface roughness measured with KEYENCE VR-6000 and relative strain distribution including deformed shape analyzed with ARGUS which is a non-contact optical strain measurement system. Differences between 3D CAD surfaces and captured geometry from experiments were evaluated to compare the effect of friction on geometric accuracy. From comparisons of experimental results, it was revealed that the polymer-based tool tip can improve surface quality and geometric accuracy by reducing the undesired material flow due to local friction in the increment sheet forming process.

Comparison for Glomerular Filtration Rate in Gamma Camera Systems Using Dynamic Renal Phantom System (동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교)

  • Kang, Chun Goo;Park, Hoon-Hee;Oh, Shin Hyun;Lee, Han Wool;Kim, Jung Yul;Oh, Joo Yung;Lee, Ju Young;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.3-9
    • /
    • 2013
  • Purpose: Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desire to evaluate the usefulness of nuclear medicine imaging. Materials and Methods: The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc-pertechnate$. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn ten times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Results: Under the same conditions infusion rate 40 mL/min fixed to adjust the pressure of the pump when the radiopharmaceuticals between 2-3 minutes in the most integrated in the kidney phantom was excreted inthe bladder. Glomerular filtration rate (GFR), respectively, by each device SYMBIA 1,091 mL/min, FORTE 1,232 mL/min, ARGUS 1,264 mL/min, INFINIA 1,302 mL/min in that there isno statistically significant difference was found, Tmax values and T1/2 values stars from all equipment with no statistically significant difference was found. CV values of the coefficient of variation less than 5% was found to be repeatable, and to 2.67% of the lowest SYMBIA appeared, INFINIA was the highest in the 4.86%. Conclusion: Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF