• 제목/요약/키워드: APEX1

검색결과 758건 처리시간 0.019초

전자제어 엔진의 공기유량센서 유동구조 연구 (Flow Mechanism around Air Flow Sensor of Electronic Control Engine)

  • 이종춘;황성만;부정숙
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권4호
    • /
    • pp.486-493
    • /
    • 2000
  • Flow mechanism around air flow sensor of electronic control engine, especially Karman vortex type, was investigated experimentally. The two-dimensional flow characteristics in the intermediate wake region behind a triangular vortex-generator respectively apex forward facing, apex backward facing and vertical flat plates following after apex forward facing(i.e vortex-flowmeter) were investigated at Reynolods number of $ReH=1.4\times10^4$; H is the width of a triangular vortex-generator. The vortex shedding frequency for wide Reynolds number from $7\times10^3$ to $2.1\times10^4$ was also surveyed. The velocity component was measured by X-type hot wire anemometer at 8H downstream from the bluff body. The coherent structure of the intermediate wake behind a bluff body was obtained by conditional phase average technique. As a result, it was verified that the vertical flat plates following after apex forward triangular vortex-generator make not only more linear relation between free stream velocity and vortex shedding frequency but also more periodic vortex in the vicinity of the center of wake.

  • PDF

Validity of the vertical tube-shift method in determining the relationship between the mandibular third molar roots and the inferior alveolar nerve canal

  • Arora, Anjana;Patil, Bharati A.;Sodhi, Amandeep
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제41권2호
    • /
    • pp.66-73
    • /
    • 2015
  • Objectives: To assess the validity of the vertical tube-shift method using intraoral periapical radiography (IOPAR) for determining the relationship between the mandibular third molar roots and the inferior alveolar nerve (IAN) canal in comparison with cone-beam computed tomography (CBCT). Materials and Methods: Fifty impacted mandibular third molars were analyzed using the IOPAR vertical tube-shift method and CBCT. The relationship of the IAN canal to the impacted mandibular third molar was recorded as buccal, lingual or in line with the apex and was compared with CBCT findings. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the vertical tube-shift method in depicting the relationship (buccal/lingual/in line with the apex) of the IAN canal to the third molar root apex was calculated. Results: The sensitivity and specificity PPV and NPV of the IOPAR vertical tube-shift technique was found to be highest for a lingual relationship (100%) followed by buccal (94.4%, 92.3%, 97.1%, and 85.7%) and in line with the apex relationship (88.9%, 95.0%, 80.0%, and 97.4%) of the IAN canal with the third molar root apex, respectively. A statistically significant association was observed between the IOPAR vertical tube-shift method and the CBCT with a P-value <0.01. Conclusion: The vertical tube-shift method can be used as an effective diagnostic tool in assessing the relationship of the IAN canal to the third molar root apex with high sensitivity, specificity, PPV, and NPV.

이공의 위치에 관한 X-선학적 연구 (ROENTGEN-ANATOMIC STUDIES ON THE MENTAL FORAMEN)

  • 이순표
    • 치과방사선
    • /
    • 제2권1호
    • /
    • pp.47-51
    • /
    • 1972
  • The author measured the distance from mental foramen to the occusal plane and classified the positional frequency of mental foramen to the tooth site using topography. The results were obtained as follow; 1. Of 964 mental foramen taken, the common site was in 2nd premolar region showing 64.08 per cent in right and 57.17 per cent in left site. 2. The average distance from occlusal plane to the upper border of premolar region was 23.20㎜. and lower border was 25.07㎜. 3. The positional variation of mental foramen was 4.77 per cent were located above the apex of the nearest tooth, and 50.42 per cent were located at the apex of the nearest tooth and 44.81 per cent were located below the apex of the nearest tooth.

  • PDF

The Low Resistivity Gate Metals Formation of Thin Film Transistors by Selective CVD

  • Park, S.J.;Bae, N.J.;Kim, S.H.;Shin, H.K.;Choi, J.S.;Yee, J.G.;Choi, S.Y.
    • 한국진공학회지
    • /
    • 제4권S1호
    • /
    • pp.108-112
    • /
    • 1995
  • Copper and aluminum selective deposition using (hfac)Cu(VTMS) and DMEAA precursors were performed in a warm-wall low pressure chemical vapour deposition reactor. The films of Cu and AI deposited on Corning 7059 glass and quartz with pattern of Cr seed metal. Selective deposition can be achieved at a pressure range of from 10-1 to 10 torr and substrate temperature range of 150-25$0^{\circ}C$. Selective deposition of Cu and AI by CVD is one of candidate for gate material formation fo larger area and high resolution plat panel displays.

  • PDF

APEX 기반 침입 탐지 시스템 개발에 관한 연구 : (주)제이드 솔류션과 공동 연구 (A Study on Developing Intrusion Detection System Using APEX : A Collaborative Research Project with Jade Solution Company)

  • 김병주
    • 한국정보전자통신기술학회논문지
    • /
    • 제10권1호
    • /
    • pp.38-45
    • /
    • 2017
  • 정보 처리 기술의 컴퓨터 및 네트워크 의존도가 심화됨에 따라 컴퓨터 및 네트워크에 대한 침입 사례가 갈수록 증가하고 있다. 시스템 및 네트워크의 침입을 방지하기 위하여 호스트와 네트워크 기반 침입차단시스템(방화벽 등)이 개발되었지만 기존의 규칙 기반의 침입차단시스템만으로는 보안 관리에 많은 어려움이 있다. 이러한 이유로 인해 시스템 및 네트워크 자원에 대한 침입을 실시간으로 탐지하고 이에 대처하는 침입탐지시스템 개발에 대한 요구가 증가하고 있다. 본 논문에서는 비선형 자료에도 적용 가능하며 수렴성이 보장된 실시간 특징 추출 방법으로 APEX 알고리즘과 점증적 LS-SVM 분류기를 결합한 실시간 침입탐지 시스템을 개발하였다. 일반적으로 실시간 처리 방식은 메모리의 효율성이 좋고 학습 자료의 추가를 허용하는 장점이 있지만 일괄처리 방식에 비해 정확도가 떨어지는 단점이 있다. 따라서 제안한 시스템은 정확도 면에서도 일괄 처리 방식과 비슷한 성능을 나타내고 있어 상용화가 가능한 시스템이다.

Pentacam을 이용한 한국 청소년 집단에서 각막의 중심두께와 전방깊이 분석 (Analysis of the Central Corneal Thickness and Anterior Chamber Depth of Eyes in Korean Young Population using the Pentacam)

  • 김덕훈;배한용
    • 한국임상보건과학회지
    • /
    • 제1권2호
    • /
    • pp.31-37
    • /
    • 2013
  • Purpose. This study was to investigate the analysis of the central corneal thickness and anterior chamber depth of eyes in Korean Young Population using the Pentacam topography. Methods. The subjects consisted of 126 eyes from normal cornea of Korean aged 7-12($8.857{\pm}1.501$) years during 2009. The thinnest location, pachy apex, and pupil central region of the cornea thickness was measured using the Pentacam pachymetry. The anterior chamber depth of normal corneas was measured with Pentacam. Results. The thinnest location of corneal thickness was $547.413{\pm}37.893$um. The pachy apex of cornea thickness was $552.103{\pm}36.016$um. Also, the pupil center of corneal thickness was measured $552.143{\pm}36.418$um. On the other hand, the mean thickness in the central cornea was a statically significant relationship(t-test, p=0.0002) between pachy apex and thinnest zone. Also the mean thickness of the central cornea was a statically significant correlation(pearson p=0.0001) among the pupil center, pachy apex and thinnest zone. The anterior chamber depth was $3.137{\pm}0.308$mm. The mean depth in the anterior chamber of cornea was a statically relationship(t-test, p>0.05) between OD and OS. Conclusions. The results of this clinical study suggested that the analysis of the central corneal thickness and anterior chamber depth using Pentacam in Korean young population can provide the useful morphological information in diagnosis of cornea for the contact lens fitting and corneal refraction surgery.

  • PDF

APEX 모형을 이용한 밭작물(콩, 배추) 물발자국 영향 평가 (Assessment & Estimation of Water Footprint on Soybean and Chinese Cabbage by APEX Model)

  • 허승오;최순군;홍성창
    • 한국환경농학회지
    • /
    • 제38권3호
    • /
    • pp.159-165
    • /
    • 2019
  • BACKGROUND: The water footprint (WF) is an indicator of freshwater use that appears not only at direct water use of a consumer or producer, but also at the indirect water use. As an indicator of 'water use', the water footprint includes the green, blue, and grey WF, and differs from the classical measure of 'water withdrawal' because of green and grey WF. This study was conducted to assess and estimate the water footprint of the soybean and Chinese cabbage. METHODS AND RESULTS: APEX model with weather data, soil and water quality data from NAS (National Institute of Agricultural Sciences), and farming data from RDA (Rural Development Administration) was operated for analyzing the WF of the crops. As the result of comparing the yield estimated from APEX with the yield extracted from statistic data of each county, the coefficients of determination were 0.83 for soybean and 0.97 for Chinese cabbage and p-value was statistically significant. The WFs of the soybean and Chinese cabbage at production procedure were 1,985 L/Kg and 58 L/Kg, respectively. This difference may have originated from the cultivation duration. The WF ratios of soybean were 91.1% for green WF and 8.9% for grey WF, but the WF ratios of Chinese cabbage were 41.5% for green WF and 58.5% for grey WF. CONCLUSION: These results mean that the efficiency of water use for soybean is better than that for Chinese cabbage. The results could also be useful as an information to assess environmental impact of water use and agricultural farming on soybean and Chinese cabbage.

구강스캐너를 이용하여 제작된 CT 가이드 임플란트 수술용 형판의 무치악 거리에 따른 정확도 분석 (Accuracy of the CT guided implant template by using an intraoral scanner according to the edentulous distance)

  • 강병길;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제55권1호
    • /
    • pp.1-8
    • /
    • 2017
  • 목적: 이 연구의 목적은 구강스캐너를 이용하여 제작된 임플란트 수술용 형판의 무치악 거리에 따른 정확성을 비교하는 것이다. 재료 및 방법: 방사선불투과성 아크릴 레진을 이용하여 상악 좌우 제2소구치, 제1대구치, 제2대구치 부위를 치아상실 상태로 5개의 상악 모형을 제작하고 각각의 모형을 구강스캐너를 이용하여 가상 모형을 획득하였다. 모형의 술전 CT DICOM file과 가상의 모형을 중첩 후 치아 상실 부위에 임플란트 식립을 계획하였고 제작된 수술용 형판을 이용하여 임플란트 식립 후 술후 CT 촬영을 시행하였다. 술전 CT와 술후 CT를 software상에서 중첩 후 X, Y, Z축을 이용하여 임플란트의 platform과 apex 부위에서, 계획된 임플란트와 실제 식립된 임플란트의 거리 및 각 오차를 측정하고 Kruskall-Wallis test와 Mann-Whitney test를 사용하여 통계분석을 시행하였다. 결과: 임플란트 식립 각도 오차는 제2소구치에서 제2대구치로 갈수록 커졌으나 통계적 차이를 보이지 않았고 platform 부위와 apex부위에서의 식립 거리 오차 또한 제2소구치에서 제2대구치로 갈수록 커지나 제2대구치에서는 통계적으로 유의성 있는 큰 오차를 보였다. 결론: 임플란트 식립 각도에서는 계획된 임플란트와 식립된 임플란트간 통계적 차이는 없었으나 platform과 apex 부위에서의 식립 거리는 제2대구치 부위의 임플란트에서 더 큰 오차를 보였으며 통계적으로 유의할 만한 차이를 보였다.

하악 대구치 근심근관에 대한 전자근관장 측정기의 정확도 (AN ACCURACY OF THE SEVERAL ELECTRONIC APEX LOCATORS ON THE MESIAL ROOT CANAL OF THE MANDIBULAR MOLAR)

  • 조영린;손욱희;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제30권6호
    • /
    • pp.477-485
    • /
    • 2005
  • 근단부위 형성이 완료되고 우식이 없는 하악 대구치 근심치근 50개를 대상으로 주파수 의존형 전자근관장 측정기를 이용하여 측정한 근관장의 정확도를 평가하기 위해 치수강 개방 후 동일한 치아에서 방사선 사진으로 확인한 실측 근관장을 대조군, 각종 전자근관장 측정기로 측정한 근관장을 실험군 ( I군: Root-ZX, II군: Bingo, III군: Propex, IV군: Diagnostic)으로 분류하여 근심협측과 설측의 근관장을 근관의 입구 측으로부터 치근단 1/3까지 확대여부 및 서로 다른 측정시기에 측정하여 비교 평가한 결과 다음과 같은 결론을 얻었다. 하악대구치 근심치근의 협측과 설측 전자근관장은 측정기의 종류, 근관의 입구 측으로부터 치근단 1/3까지의 확대여부 및 측정시기에 상관없이 0.5mm이내의 오차범위를 나타내었으며, 근관치료시 오차한계인 ${\pm}1mm$에서 정확성은 근관의 입구 측으로부터 치근단 1/3까지 미리 확대한 후에 근관장을 측정할 경우와 측정시기가 반복될 경우에 증가되는 경향을 보여 임상에 유용하게 활용할 수 있을 것으로 사료된다.

Analysis on the corneal thickness and anterior chamber depth of the Keratoconus using Pentacam

  • Kim, Douk-Hoon;Sapkota, Kishor
    • 한국임상보건과학회지
    • /
    • 제6권1호
    • /
    • pp.1089-1096
    • /
    • 2018
  • Purpose: To investigate the corneal thickness and anterior chamber depth (ACD) of eyes with Keratoconus in the Korean population with the Pentacam. Methods: The subjects consisted of 84 eyes from Keratoconic adults aged 7-59 years during 2010. The thinnest area, apex zone, and pupil centre of the corneal thickness were measured using the Pentacam pachymetry. ACD value was also measured with Pentacam. Results: There was a statistically significant relationship between thickness of the cornea at the apex area and the pupil centre (p=0.0001). However, there was no statistical difference (p>0.5) in the mean thickness of thinnest area, apex zone, pupil centre of cornea between right eye and left eye. Also, correlation between ACD and corneal thickness in all subjects had no statistical differences (p>0.05) in all subjects. Conclusion: These results suggested that the regional thickness of cornea and ACD with Pentacam can provide correct and useful diagnostic information of the morphology of Keratoconus for the RGP contact lens and diagnosis of abnormal corneal refraction surgery.