EVALUATION OF THE ACCURACY OF THE APEX FINDER A.F.A. (APEX FINDER A.F.A.의 정확성에 관한 연구)

  • Yang, Mi-Young;Yoo, Hyeon-Mee;Oh, Tae-Seok
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.670-675
    • /
    • 1998
  • Recently electronic apex locators have been used widely in root canal treatment, but, accuracy of electronic apex locators is controversial. The purpose of this study was to evaluate the accuracy of Apex Finder A.F.A(EIE Analytic Technology, U.S.A.) in vivo compared with Root-Zx and radiograph. The root canal lengths were determined with Root-Zx(32 tooth) in before pulp extirpation and after pulp extirpation. Then the radiographs were taken with a file in the canal. The root canal lengths were determined with Apex Finder A.F.A.(21 tooth) in before pulp extirpation and after pulp extirpation and under NaOCl. Then the radiographs were taken with a file in the canal. The results were as follows: 1. There was no significant statistical difference in Root-Zx between before pulp extirpation and after pulp extirpation(p > 0.05). 2. There was no significant statistical difference in Apex Finder A.F.A. between before pulp extirpation and after pulp extirpation(p > 0.05). But, there was significant statistical difference under NaOCl(p < 0.05). 3. There was no significant statistical difference in accuracy between Root-Zx and Apex Finder A.F.A.

  • PDF

EVALUATION OF THE ACCURACY OF THE ELECTRONIC APEX LOCATOR USING THE POLARIZING MICROSCOPE (편광현미경을 이용한 전자적근관장측정기의 정확성에 관한 연구)

  • Park, Han-Soo;Yoon, Soo-Han
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.1
    • /
    • pp.235-243
    • /
    • 1992
  • The purpose of this study was to evaluate the accuracy of an electronic apex locator, the Neosono - M, in determining the location of the cementodentinal junction. A total of 26 teeth with 46 canals were evaluated. The apex locator was used to locate the file and the teeth extracted. The specimen were prepared with highspeed burs and sandpaper discs to a thickness of $250{\sim}300{\mu}m$. Distances were measured from the cementodentinal junction with the use of polarizing microscope. Measurements made by the apex locator were also compared with those by the X - ray. The results were as follows. 1. The apex locator and X - ray were to measure a mean value of 0.17, 0.45mm coronal to the CDJ respectively. There was no significant difference between the accuracy of the apex locator and that of X - ray. 2. There was no significant difference between the accuracy of apex locator in vital and in nonvital teeth, and between in narrow and in wide canals. 3. The files in nonvital and narrow group were apical to the CDJ significantly than those of vital and narrow, vital and wide, and non vital and wide groups.

  • PDF

Development of QAPEX Module using Open Source GIS (오픈 소스 기반의 GIS 소프트웨어를 이용한 QAPEX 모듈 개발)

  • Koo, Ja Young;Lee, Seo Ro;Choi, Soon Kun;Lim, Kyoun Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.175-175
    • /
    • 2017
  • Agricultural Policy/Environmental eXtender Model(APEX)는 전 농장 또는 소규모 유역 관리에 활용하고자 개발된 모형이다. APEX는 사용자들을 고려하고 다양한 형태로 개발하였다. 사용자들이 사용하기 쉽도록 윈도우 인터페이스 형태의 WinAPEX 모듈을 개발하기도 하였으며, ArcGIS 프로그램과 연계하여 다양한 지리정보시스템을 사용할 수 있는 ArcAPEX 모듈을 개발하기도 하였다. 그러나 WinAPEX 모듈은 유역에 대한 정보를 시각적으로 확인할 수 없다는 단점을 가지고 있으며, ArcGIS 프로그램은 유료의 라이센스라는 단점을 보유하고 있다. 본 연구에서는 이러한 단점을 극복하기 위하여 APEX 모형을 GNU General Public License 기반의 Open Source Geographic Information System(GIS)인 Quantum GIS(QGIS)와 연계하여 QAPEX 모듈을 개발하고자 하였다. QAPEX 모듈은 오픈소스 기반의 QGIS 프로그램과 APEX 모형을 이용하여 무료로 사용할 수 있으며, 사용자의 편의를 위해 유역에 대한 정보를 시각적으로 확인할 수 있다. 뿐만아니라 QGIS는 사용자간의 정보 및 자료 공유에 용이한 장점을 보유하고 있어 QAPEX를 이용하는 사용자들 간의 정보 공유로 인해 원활하고 지속적인 개선이 이루어 질 것으로 기대된다.

  • PDF

SIMULATED AP1000 RESPONSE TO DESIGN BASIS SMALL-BREAK LOCA EVENTS IN APEX-1000 TEST FACILITY

  • Wright, R.F.
    • Nuclear Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.287-298
    • /
    • 2007
  • As part of the $AP1000^{TM}$ pressurized water reactor design certification program, a series of integral systems tests of the nuclear steam supply system was performed at the APEX-1000 test facility at Oregon State University. These tests provided data necessary to validate Westinghouse safety analysis computer codes for AP1000 applications. In addition, the tests provided the opportunity to investigate the thermal-hydraulic phenomena expected to be important in AP1000 small-break loss of coolant accidents (SBLOCAs). The APEX-1000 facility is a 1/4-scale pressure and 1/4-scale height simulation of the AP1000 nuclear steam supply system and passive safety features. A series of eleven tests was performed in the APEX-1000 facility as part of a U.S. Department of Energy contract. In all, four SBLOCA tests representing a spectrum of break sizes and locations were simulated along with tests to study specific phenomena of interest. The focus of this paper is the SBLOCA tests. The key thermal-hydraulic phenomena simulated in the APEX-1000 tests, and the performance and interactions of the passive safety-related systems that can be investigated through the APEX-1000 facility, are emphasized. The APEX-1000 tests demonstrate that the AP1000 passive safety-related systems successfully combine to provide a continuous removal of core decay heat and the reactor core remains covered with considerable margin for all small-break LOCA events.

Evaluation of Stream Water Quality by Using the SWAPP (SWAT-APEX Program) Model Including Yedang Reservoir Watershed (수질모델링을 위한 SWAPP (SWAT-APEX Program) 모형의 적용성 평가 -예당저수지 유역을 대상으로-)

  • Jung, Chung-Gill;Park, Jong-Yoon;Joh, Hyung-Kyung;Lee, Jun-Woo;Kwon, Hyung-Joong;Kim, Seong-Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.179-179
    • /
    • 2011
  • 근래 농촌지역에서의 하천 및 저수지의 수질오염에 관하여 관심이 고조됨에 따라 비오염원에 대한 파악과 대책을 세우기 위해 관련분야에서 많은 연구가 진행 되고 있다. 비점오염원은 주로 강우나 유출에 의해 배출되기 때문에 배출 장소와 경로가 불분명하고 다양하다. 비점오염의 관리를 위한 유역모델로 SWAT (Soil and Water Assessment Tool) 모델을 이용한 연구가 광범위하게 사용되고 있다. 그러나 SWAT 모델은 유역모델로써 농촌지역에 논, 밭에서의 비점오염원 기작을 표현하기에는 공간적 범위의 한계가 있다. 이에 본 연구에서는 예당저수지 유역(465.12 km2)을 대상으로 유역규모의 SWAT 모델과 유역-필드규모에 적용 가능한 SWAT-APEX (Agricultural Policy/Environmental eXtender) 모델의 수질(T-N, T-P) 모의결과를 비교하여 SWAT-APEX 모델의 적용성을 평가하고자 하였다. 모형의 적용을 위한 입력자료로 기상자료와 지형자료를 구축하였으며 기상자료로 예당저수지유역 3개의 강우관측소 자료를 수집하여 구축하였으며, 지형자료로 격자크기 30m의 DEM (Digital Elevation Model)과 농촌진흥청에서 제공하는 1:25,000 정밀토양도와 토지이용도는 환경부로부터 1:25,000 중분류 토지이용도를 이용하였다. 또한 환경부에서 제공하는 월단위 하천수질 자료(기간)를 구축하여 모형의 검증을 실시하였다. 분석과정으로 SWAT 모델에서의 유역차원 수문, 수질 모의를 한 후, APEX 모델을 이용하여 소유역별 논, 밭에 대한 필드단위에 오염물질 모의 후 각각 소유역 출구에서 APEX 모델에 결과를 반영한 SWAT-APEX 모의를 거쳐 최종 유역출구에서의 유출량과 수질항목을 분석하였다. 모의 결과 유출량에 대해 Nash와 Sutcliffe (1970)가 제안한 모델효율성계수 (Model Efficient, ME)는 0.67, 결정계수는 0.69 그리고 수질항목의 결정계수는 각각 0.77, 0.75으로 분석되었다. 또한, SWAT-APEX 모의 결과 수질항목의 결정계수는 각각 0.80, 0.72이었다. 따라서, 본 연구에서 농촌지역의 비점오염원 모의는 필드모의를 반영한 SWAT-APEX 모델 결과가 SWAT 모델만 적용한 결과보다 정확한 비점오염 모의가 이루어졌다고 판단 할 수 있다.

  • PDF

Construction of Database for Application of APEX Model in Korea and Evaluation of Applicability to Highland Field (APEX 모델의 국내 적용을 위한 데이터베이스 구축 및 고랭지 밭에 대한 적용성 평가)

  • Koo, Ja-Young;Kim, Jonggun;Choi, Soon-Kun;Kim, Min-Kyeong;Jeong, Jaehak;Lim, Kyoung Jae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.6
    • /
    • pp.89-100
    • /
    • 2017
  • The Agricultural Policy/Environmental eXtender (APEX) model was developed to extend EPIC's capabilities of simulating land management impacts for small-medium watershed and heterogeneous farms. APEX is a flexible and dynamic tool that is capable of simulating a wide array of management practices, cropping systems, and other land uses across a broad range of agricultural landscapes. APEX have its own agricultural environmental database including operation schedule, soil property, and weather data etc., by crops. However, agriculture environmental informations the APEX model has is all based on U.S. As this can cause malfunction or improper simulation while simulating highland field. In this study, database for APEX model to be utilized for South Korea established with 44,814 agriculture fields in Pyeongchang-gun, Korea from 2007 to 2016. And assessed domestic applicability by comparing T-P unit load criteria presented by National Institution of Environmental Research and result of APEX model. As a result of APEX model simulation, average T-P value for decade was 6.18. Average T-P of every year except 2011 was in range of 5.37~10.43 and this is being involved into criteria presented by National Institution of Environmental Research. It is analyzed that adjusting slope factor can make the model applicable for domestic agricultural environment.

Calibration of APEX-Paddy Model using Experimental Field Data

  • Mohammad, Kamruzzaman;Hwang, Syewoon;Cho, Jaepil;Choi, Soon-Kun;Park, Chanwoo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.155-155
    • /
    • 2019
  • The Agricultural Policy/Environmental eXtender (APEX) models have been developed for assessing agricultural management efforts and their effects on soil and water at the field scale as well as more complex multi-subarea landscapes, whole farms, and watersheds. National Academy of Agricultural Sciences, Wanju, Korea, has modified a key component of APEX application, named APEX-Paddy for simulating water quality with considering appropriate paddy management practices, such as puddling and flood irrigation management. Calibration and validation are an anticipated step before any model application. Simple techniques are essential to assess whether or not a parameter should be adjusted for calibration. However, very few study has been done to evaluate the ability of APEX-Paddy to simulate the impact of multiple management scenarios on nutrients loss. In this study, the observation data from experimental fields at Iksan in South Kora was used in calibration and evaluation process during 2013-2015. The APEX auto- calibration tool (APEX-CUTE) was used for model calibration and sensitivity analysis. Four quantitative statistics, the coefficient of determination ($R^2$),Nash-Sutcliffe(NSE),percentbias(PBIAS)androotmeansquareerror(RMSE)were used in model evaluation. In this study, the hydrological process of the modified model, APEX-Paddy, is being calibrated and tested in predicting runoff discharge rate and nutrient yield. Field-scale calibration and validation processes are described with an emphasis on essential calibration parameters and direction regarding logical sequences of calibration steps. This study helps to understand the calibration and validation way is further provided for applications of APEX-Paddy at the field scales.

  • PDF

Effects of Apex Removal on the Growth and Yield of Artichoke by Planting Times (정식시기별 생장점 제거가 아티초크(Cynara scolymus L.)의 생육 및 수량에 미치는 영향)

  • Seong, Ki-Cheol;Kim, Chun Hwan;Son, Danial;Lim, Chan Gyu;Cheon, Sung Jong
    • Journal of Bio-Environment Control
    • /
    • v.23 no.1
    • /
    • pp.56-59
    • /
    • 2014
  • Apex removal is a common practice in artichoke cultivation to harvest heads of lateral shoots. This experiment was carried out to investigate the effect of apex removal by different planting times on the growth and yield of Artichoke (Cynara scolymus L.) in open field. Two treatments (apex removal and no apex removal) at three different planting times ($1^{st}$: Sep. 27, 2011, $2^{nd}$: March 29, 2012, and $3^{rd}$: Sep. 21, 2012) were tested using 'Green Globe' variety. There was no difference in the head characteristics and the number of harvested head between the treatments. The head weight was heavier in no apex removal of 242.7 g than the apex removal of 170.8 g. The yield also increased in no apex removal by 25% (1,249 kg/10a) compared to the apex removal of 997 kg/10a at the first planting time. At the second planting time, there was no difference in the head weights between the treatments. But the number of the harvested head was higher in no apex removal with 10.8 than 8.2 of the apex removal. The yield of no apex removal was 2,660 kg/10a, which was higher than 1,848 kg/10a of apex removal. At the third planting time, the head weight increased in no apex removal with 253.5 g compared to the apex removal with 218.7 g. The yield of no apex removal was 1,405 kg/10a, which was higher than 1,148 kg/10a of the apex removal. All the tests at 3 different planting times showed that the artichoke yields were higher in no apex removal than in apex removal. Therefore, it is desirable to cultivate artichoke without removing the apex for the higher yield and labor saving in open-field cultivation in Jeju island.

In vivo evaluation of accuracy and consistency of two electronic apex locators (2종 전자근관장측정기의 정확도 및 일관성에 관한 in vivo 연구)

  • Pi, Chien-Yun;Kim, Eui-Seong;Jung, Il-Young;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.453-460
    • /
    • 2010
  • Objectives: To evaluate the accuracy and consistency of two different apex locators at both the Apex and 0.5 marks. Materials and Methods: Twenty-six root canals was scheduled for extraction for periodontal or prosthodontic reasons. Thirteen canals were measured using Root ZX and the rest by i-ROOT. The root canal length was measured both the at 0.5 mark and the Apex mark. The file was then fixed to the toot, and the distance from the file tip to the major foramen of each canal was measured after removing the root dentin under the microscope so that the major foramen and the file tip were seen. Results: 1. When the Apex mark was used, 100% of both the Root ZX and i-ROOT groups were within 0.5 mm of the major foramen. 2. When 0.5 mark was used, 100% of the Root ZX group and 77% of the i-ROOT group were within 0.5 mm of the major foramen. 3. In terms of standard deviation and quartile value, the Apex mark was more consistent than 0.5 mark in the Root ZX group, and 0.5 mark was more consistent in the i-ROOT group, but there was no statistically significant difference when compared with t-test. 4. The root canal length difference between the Apex mark and 0.5 mark was 0.22 mm and 0.46 mm in the Root ZX and i-ROOT groups, respectively. Conclusions: In this study, the Apex mark was the more consistent mark. Therefore, it is recommended to subtract 0.5 mm, which is the average length between the apex and apical constriction, from the root canal length at the Apex mark to obtain the working length clinically.

Positional relationship between the maxillary sinus floor and the apex of the maxillary first molar using cone beam computed tomograph (Cone beam형 전산화단층영상을 이용한 상악동저와 상악제1대구치 치근단괴의 위치관계)

  • Kim, Kyoung-A;Koh, Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.38 no.2
    • /
    • pp.95-101
    • /
    • 2008
  • Purpose: To assess the positional relationship between the maxillary sinus floor and the apex of the maxillary first molar using cone beam computed tomograph (CBCT). Materials and Methods: CBCTs from 127 subjects were analysed. A total of 134 maxillary first molars were classified according to their vertical and horizontal positional relationship to the maxillary sinus floor and measured according to the distance between the maxillary sinus floor and the maxillary first molar. Results: Type III (The root projected laterally on the sinus cavity but its apex is outside the sinus boundaries) was dominated between 10 and 19 years and type I (The root apex was not in contact with the cortical borders of the sinus) was dominated (P<0.05) between 20 and 72 years on the vertical relationship between the maxillary sinus floor and the apex of the maxillary first molar. The maxillary sinus floor was located more at the apex (78.2%) than at the furcation (21.3%) for the palatal root. The distance from the root apex to the maxillary sinus floor confined to type I was increased according to the ages (P<0.05). Type M (The maxillary sinus floor was located between the buccal and the palatal root) was most common (72.4%) on the horizontal relationship between the maxillary sinus floor and the apex of the maxillary first molar. Conclusion: CBCT can provide highly qualified images for the maxillary sinus floor and the root apex of the maxillary first molar.

  • PDF