• Title/Summary/Keyword: AP position

Search Result 188, Processing Time 0.025 seconds

Design and Implementation of Outdoor Positioning System Using MSS Mechanism & Wireless AP characteristic (MSS 기법과 무선 AP 특징을 활용 실외 측위 시스템 설계 및 구현)

  • Lee, Hyoun-Sup;Kim, Jin-Deog
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.3
    • /
    • pp.433-439
    • /
    • 2011
  • The positioning system based on wireless AP collects AP information distributed in the real world, stores it into database, and measures the position objects by comparing with searched AP information. The existing fingerprinting method is a probabilistic modeling method that acquires much of the data collected from one location upon database composition, and stores the average of the data for the sake of use it in positioning objects. Using the average value, however, may cause the probability of errors Such errors are fatal weaknesses for services based on the accurate position. This paper described the characteristics and problems of the previously used wireless AP positioning system, and proposed a method of using the AP DB and an MSS mechanism for outdoor positioning in order to solve the aforementioned problems. And the results obtained from experimental tests showed that the proposed method achieved very low error rate(27%) compared with the existing method.

A Comparative Study on the Changes of Pelvic Alignment between AP View of the Pelvis in Standing and Supine Position (Pelvic AP X-ray 촬영 자세에 따른 골반변위 변화의 비교 연구)

  • Lee, Kyung-Moo;Park, Dong-Su;Kim, Soon-Joong;Jeong, Su-Hyeon
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.18 no.4
    • /
    • pp.161-169
    • /
    • 2008
  • Objectives : This study was carried out to investigate the relationship of pelvic alignment between AP view of the pelvis in standing and supine position. Methods : Sixteen healthy peoples who get $51.59{\pm}4.14$ as average in SF-36 were evaluated by X-ray findings. After measuring innomiate measurement, off centering measurement, sacral ala measurement, illium shadow measurement, the area of obturator foramen, those were analyzed statistically. Results : It was not all to be corresponded to distort pelvic alignment of AP view of the pelvis in standing and in supine. Sometimes it was the opposite result. Conclusions : These results suggest that the diagnosis of pelvic alignment to go through on each position is brought about disagreement with each other.

Patient Radiation Exposure Dose Evaluation of Whole Spine Scanography Due to Exposure Direction (Whole Spine Scanography의 검사방향에 따른 환자 선량 평가)

  • Kim, Jung-Su;Seo, Deok-Nam;Kwon, Soon-Mu;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Whole spine scanography (WSS) is a radiological examination that exposes the whole body of the individual being examined to x-ray radiation. WSS is often repeated during the treatment period, which results in a much greater radiation exposure than that in routine x-ray examinations. The aims of the current study were to evaluate the patient dose of WSS using computer simulation, image magnification and angulation of phantom image using different patient position. We evaluated the effective dose(ED) of 23 consecutive patients (M : F = 13:10) who underwent WSS, based on the automatic image pasting method for multiple exposure digital radiography. The Anterior-Posterior position(AP) and Posterior-Anterior position( PA) projection EDs were evaluated based on the PC based Monte Carlo simulation. We measured spine transverse process distance and angulation using DICOM measurement. For all patient, the average ED was 0.069 mSv for AP position and 0.0361 mSv for PA position. AP position calculated double exposure then PA position. For male patient, the average ED was 0.089 mSv(AP) and 0.050 mSv(PA). For female patient, the average ED was 0.0431 mSv(AP) and 0.026 mSv(PA). The transverse process of PA spine image measured 5% higher than AP but angulation of transverse process was no significant differences. In clinical practice, just by change the patient position was conformed to reduce the ED of patient. Therefor we need to redefine of protocol for digital radiography such as WSS. whole spine scanography, effective dose, patient exposure dose, exposure direction. protocol optimization.

Performance Analysis of Multi-Gigabit Wireless Transmission at THz WLAN-Type Applications

  • Choi, Yonghoon
    • Journal of Communications and Networks
    • /
    • v.16 no.3
    • /
    • pp.305-310
    • /
    • 2014
  • Optimal position of access point (AP) is important for multi-gigabit wireless transmission in terahertz (THz) wireless local area network (WLAN)-type applications, where there exist the THz characteristic multiple clusters in channel propagation. By considering the multiple clusters in THz indoor communications, this paper investigates the optimal AP position when two APs are issued for increasing the system capacity. Numerical results reveal that the central position of each AP within each half service region, which offers the shortest cumulated path length for line-of-sight paths, is optimal to achieve the maximal system capacity.

System Design for Location Determination Inside the Ship (선박 내부 위치 측위를 위한 시스템 설계)

  • Park, Jin-Gwan;Jung, Min A;Yoon, Seokho;Lee, Seong Ro
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.2
    • /
    • pp.181-188
    • /
    • 2013
  • In this paper, we present a system design for location determination inside the ship. Since the GPS signal can not be received in the interior of the large vessel, we use the vessel wireless AP (Access Point) RSSI (received signal strength indication) to accurately measure the position. We convert the RSSI for the 3 AP's into distance through the Friis formula and get the location through triangulation. The signal strength varies irregularly due to noise making it difficult to obtain the exact location. Thus Kalman filter is used to real-time position correction, that is store in a server database.

A Study on Efficient Access Point Installation Based on Fixed Radio Wave Radius for WSN Configuration at Subway Station (지하철 역사 내 WSN 환경구축을 위한 고정 전파범위 기반의 효율적인 AP설치에 관한 연구)

  • An, Taeki;Ahn, Chihyung;Lee, Youngseok;Nam, Myungwoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.740-748
    • /
    • 2016
  • IT and communication technologies has contributed significantly to the convenience of passengers and the financial management of stations in accordance with the task automation in the field of the urban railway system. The foundation of the above development is based on the large amounts of data from various sensors installed in railways, trains, and stations. In particular, the sensor network that is installed in the station and train has played an important role in the railway information system. The performance of AP is affected by the number of APs and their locations installed in the station. In the installation of APs in stations, the intensity of the radio wave of the AP on its underlying position is considered to determine the number and position of APs. This paper proposes a method to estimate the number of APs and their position based on the structure of the underlying station and implemented a simulator to simulate the performance of the proposed method. The implemented simulator was applied to the decision of AP installation at Busan Seomyeon station to evaluate its performance.

WiFi Wireless Network based Control System (WiFi 무선 네트워크 기반의 제어 시스템)

  • Jeong, Eui-Hoon;Lim, Jung-Gwon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.575-577
    • /
    • 2013
  • Recently most of the hand-held smart devices have WiFi communication facility. This makes WiFi AP(access point) popular and cheaper than before. These circumstance launches some services with AP providing location based services and device control services. In this paper, we propose a AP based control system. The control system consists of AP's, AP controller and Android application program. The AP can collect MAC address information of the associated smart devices and control connected devices. The AP controller maintains DB for smart device position information and device control information. Finally Android application program provides users location based service and device control service.

  • PDF

The Image Distortion Analysis of Levin-tube tip by Patient position and Incidence Angle when taking Mobile Chest AP Projection (Mobile Chest AP 검사 시 환자자세와 입사각도에 따른 Levin-tube tip의 영상왜곡 분석)

  • Lee, Jinsoo;Park, Hyonghu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.467-471
    • /
    • 2015
  • This study's purpose is improve image quality to keep accurate tube angle in order to recognize distortion degree conditions by patient's position or tube angle and to provide exact clinical informations when taking chest AP projection for patient which have L-tube in stomach. The experimental equipment was ELMO-T6S by SHIMADZU corporation, then we put L-tube which attached 1 mm gap scales ruler on chest phantom surface. The experiment set by 90 kVp, 4 mAs, 120 cm distance. Each phantom position which changed supine, 30degree, 45degree, 60degree on the table exposured direct, ${\pm}5degree$, ${\pm}10degree$, ${\pm}15degree$ to head and feet directions. As a result, L-tube tip's position was changed by patient's position and tube angle. When patient's position is supine, tip's position change was lower than 30degree, 45degree, 60degree. We have to adjust patient's position or tube angle in order to occur image distortion by fault tube angle when confirming correct position L-tube tip through chest x-ray. Also, Radiological technologist try to make accurate evaluation index for satisfied L-tube insertion.

Radiographic Evaluation of Condyle Position at Maximum Intercuspal Position Using Cone-beam CT (Cone-beam CT를 이용한 최대교두간접촉위(MIP)에서 과두 위치에 대한 방사선적 평가)

  • Oh, Sang-Chun;Chee, Young-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.111-120
    • /
    • 2010
  • Purpose: This investigation was designed to evaluate the condyle position and the symmetry of the both condyle heads at the maximum intercuspal position on the sagittal CT image of the temporomandibular joint. Materials and Methods: Cone-beam CT was used to assess 400 joints in 100 symptom and 100 symtom-free subject(100 male, 100 female). Three independent observers(dentists) determined the positions classified with Anterior Position(AP), Middle Position(MP), and Posterior Position(PP), and the symmetry of the both condyle. Results: According to gender, the mean percentages of AP, MP, and PP were 48.5, 28.5, and 23 in male group, and 34, 38, and 28 in female group. The symmetry of condylar heads was more common than asymmetry in the both of groups. In the respect of symptom or symptom-free, the mean percentages of AP, MP, and PP were 44.5, 34, and 21.5 in the symptom-free group, and 37, 33.5, and 29.5 in the symptom group. The symmetry of condylar heads was more common in the symptom-free group, but the asymmetry of condylar heads was more common in the symptom group. Conclusions: These data might serve as useful criteria for the clinical assessment of condyle position at the maximum intercuspal position optained by Cone-beam CT.

The Usefulness of Magnification of the Heart Shadow in Chest Radiography (흉부 촬영시 심음영 확대에 따른 유용성에 관한 연구)

  • Park, Eun-Gyung;Lee, Kun-Young;Jung, Young-Tae;Dong, Kyung-Rae;Ji, Youn-Sang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.119-125
    • /
    • 2010
  • In order to demonstrate the value of long-distance radiography, we have studied how distance affects images in chest frontal radiography and compared short-distance and long-distance images in chest lateral radiography. Cardiothoracic ratio(CTR %) of 50 patients with no disease in the chest(10 each at the age of 20~60) were evaluated in Supine AP(100 cm), Sitting AP(100 cm), Sitting AP(180 cm), and Erect PA(180 cm). In lateral radiography, we evaluated and compared left lateral radiography(100 cm and 180 cm) of the patients based on the horizontal maximum of the heart. The average value of CTR(%) were 0.48 in Erect PA(180 cm), 0.52 in Supine AP(100 cm), 0.50 in Sitting AP(100 cm), 0.49 in Sitting AP(180 cm), which were Supine AP(100 cm) > Sitting AP(100 cm) > Sitting AP(180 cm) > Erect PA(180 cm). The average value of Maximum transverse diameter of left of the cardiac(MLD), which showed how much axis of spine was slanted to the left, was 90.67 mm in Erect PA(180 cm), 103.92 mm in Supine AP(100 cm), 93.54 mm in Sitting(100 cm), 89.84 mm in Sitting AP(180 cm), 58.11 mm in the minimum value and 118.79 mm in the maximum value. The average value of Maximum transverse diameter of right side of the cardiac(MRD), which suggested how much axis of spine was slanted to the right, was 47.18 mm in Erect PA(180 cm), 48.12 mm in Supine AP(100 cm), 44.98 mm in Sitting AP(180 cm), and the minimum value 26.84 mm and the maximum value 65.30 mm. There was no standard method to calculate; therefore, the horizontal maximum of the heart was used for lateral radiography. The average value was 121.07 mm in 100 cm and 109.76 mm in 180 cm. Sitting AP(180 cm) among the types was closest to C-PA(180 cm). As a result, during C-AP radiography, long-distance radiography lessened shadow of the heart more than that of short distance, Sitting position more than Supine position.

  • PDF