• Title/Summary/Keyword: ANSI Phantom

Search Result 15, Processing Time 0.025 seconds

A Theoretical Calculation of Photon Dose Equivalent Conversion Factor For Extremity Dosimeter (말단선량계의 광자선량당량환산인자에 대한 이론적 계산)

  • Kim, Kwang-Pyo;Lee, Won-Keun;Kim, Jong-Su;Yoon, Yeo-Chang;Yoon, Suk-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.1
    • /
    • pp.41-50
    • /
    • 1996
  • In this study, the theoretical calculation of the air kerma-to-dose equivalent conversion factors was performed with a Monte Carlo N-Particle transport code for the two types of extremity phantom of the ANSI and the KAERI, respectively. Considering the distribution of absorbed dose due to the interaction of homogeneous Parallel broad beam of monoenergetic primary photons in the range between 15keV and 1.5MeV, the air kerma-to-dose equivalent conversion factors based on the kerma approximation were calculated. It is showed that all the theoretical conversion factors of the two types of the extremity phantom for the ANSI and the KAERI agree well with the experimental values of the ANSI N13.32 draft(1995) for each energy within 5.7%, maximum difference ratio, except for 13.6%, difference ratio in the case for the energy of less than 40keV. It is due to uncertainties of experiment occurred in the low X-ray energy range and geometry considered in the MCNP code.

  • PDF

A Theoretical Calculation for Angular Dependence of X-ray Beams on Extremity Phantom (말단팬텀에서 X-선 빔의 방향의존성에 관한 이론적 계산)

  • Kim, Jong-Soo;Yoon, Suk-Chul;Kim, Jang-Lyul;Kim, Kwang-Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.263-271
    • /
    • 1996
  • The ANSI N13.32 recommends that a study of the angular response of a dosimeter be carried out once, although no pass/fail criterion is given for angular response. Gamma dose equivalent conversion and angular dependence factors were calculated by using MCNP code for the case of ANSI N13.32 extremity phantoms(finger and arm) at the depth of $7mg/cm^2$. Those extremity dosimeters were assumed to be irradiated from both monoenergitic photons and ISO X-ray narrow beams. These calculated gamma dose equivalent conversion and angular dependence factors were compared to B. Grosswendt's result calculated by using X-ray beams. The result showed that the dose equivalent conversion factors of this study agreed well with that of B. Grosswendt for all energies within 2% except 7% in the case of the low energies. In the case of angular dependence factors comparison, they agreed within 3%. It was shown that angular dependence factors of the finger phantom decreased as the horizontal angle of the phantom increased for the ISO X-ray beams less than 60keV. For the higher energy X-ray beams range they decreased slightly around 40 degree, but then increased from this energy to 90 degree.

  • PDF

A New Approach for the Calculation of Neutron Dose Equivalent Conversion Coefficients for PMMA Slab Phantom (PMMA 평판형 팬텀에서의 중성자 선량당량 환산계수의 새로운 계산법)

  • Kim, Jong-Kyung;Kim, Jong-Oh
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.297-311
    • /
    • 1996
  • ANSI decided PMMA slab phantom as a calibration phantom and introduced a conversion coefficient calculation method for it. For photon, the conversion coefficient can be obtained by using backscatter factor and conversion coefficient of the ICRU tissue cube and backscatter factor of the PMMA slab. For neutron, however, the ANSI has not introduced any conversion coefficient calculation method for the PMMA slab. In this work, the ANSI method for the photon conversion coefficient calculation was applied to the neutron conversion coefficient calculation of the PMMA slab. Quality weighted tissue kerma of neutron was applied to calculate the backscatter factors on the ICRU cube and the PMMA slab. The dose conversion coefficient of the ICRU cube was also calculated by using MCNP code. Then, the dose conversion coefficient of the PMMA slab was calculated from two backscatter factors and the dose conversion coefficient of the ICRU cube. The discrepancies of the dose conversion coefficients of the PMMA slab and the ICRU cube were less than 10% except 1eV(20%), 1keV(17%), and 4 MeV(16%).

  • PDF

An Experimental Study on the Speeds of Various Screen-Film Systems (증감지(增感紙)-Film계(系)의 감도측정(感度測定)에 관(關)한 실험(實驗))

  • Kang, Hong-Seok;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.11 no.1
    • /
    • pp.3-16
    • /
    • 1988
  • Author has made an experiment on absolute speeds of 18 screenfilm combinations that have been on sale in Korea, with various beam qualities. At this time, the beam qualities were 60kVp with the ANSI extremity phantom, 80kVp with the ANSI chest phantom and 85kVp with 20 mm aluminium filter under scatter free condition. The obtained results were as follows; 1. When three independent measurements were performed, the percent standard deviations of mAs quantities of 1.0 + fog were decreased by the hardening of the beam quality, and the decreasing tendency was somewhat great in the blue systems. 2. Generally, the increasing tendency of absolute speeds was distinct by the hardening of the beam quality in the green systems. Conclusively, the green systems were more strongly dependent upon the beam quality rather than the blue systems. Therefore, the relative speed of green systems to blue systems were great under the same condition. 3. Differences in the green systems were kept almost constant even though the beam qualities were changed. 4. They were shown the mutual relationship of absolute speed and relative speed rather than independent.

  • PDF

A Study for Effects of Image Quality due to Scatter Ray produced by Increasing of Tube Voltage (관전압 증가에 기인한 산란선 발생의 화질 영향 연구)

  • Park, Ji-Koon;Jun, Je-Hoon;Yang, Sung-Woo;Kim, Kyo-Tae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.663-669
    • /
    • 2017
  • In diagnostic medical imaging, it is essential to reduce the scattered radiation for the high medical image quality and low patient dose. Therefore, in this study, the influence of the scattered radiation on medical images was analyzed as the tube voltage increases. For this purpose, ANSI chest phantom was used to measure the scattering ratio, and the scattering effect on the image quality was investigated by RMS evaluation, RSD and NPS analysis. It was found that the scattering ratio with increasing x-ray tube voltage gradually increased to 48.8% at 73 kV tube voltage and to 80.1% at 93 kV tube voltage. As a result of RMS analysis for evaluating the image quality, RMS value according to increase of tube voltage was increased, resulting in low image quality. Also, the NPS value at 2.5 lp/mm spatial frequency was increased by 20% when the tube voltage was increased by 93 kV compared to the tube voltage of 73 kV. From this study, it can be seen that the scattering radiation have a significant effect on the image quality according to the increase of x-ray tube voltage. The results of this study can be used as basic data for the improvement of medical imaging quality.

Calculation of Neutron and Gamma-Ray Flux-to-Dose-Rate Conversion Factors

  • Kwon, Seog-Guen;Kim, Kyung-Eung;Ha, Chung-Woo;Moon, Philip S.;Yook, Chong-Chul
    • Nuclear Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.171-179
    • /
    • 1980
  • This paper presentss flux-to-dose conversion factors for neutrons and gamma-rays based on the concept of the maximum absorbed dose. Neutron flux-to-does-rate conversion factors for energies from 2.5$\times$10$^{-8}$ to 20 MeV are presented while the conversion factors for gamma-rays are given in the energy range of 0.01 to 15MeV. Flux-to-does-rate conversion factors, which were calculated under the assumption that the radiation energy distribution has nonlinearity in phantom, are different from those values obtained by monoenergetic radiation. Especially, these values obtained here were determined for the cross section libray such as DLC-23, DLC-27, and DLC-31. The flux-to-dose-rate conversion factors obtained in this work are in a good agreement with the values presented by American National Standard Institute (ANSI) N666. These results are used to calculate the dose rate distribution of neutron and gamma-ray in any radiation fields, and will be useful for the radiation shielding analysis, radiation protection and radiation dosimetry concerned with problems of continuous energy distribution.

  • PDF

Calculation of Neutron and Gamma-Ray Flux-to-Dose-Rate Conversion Factors (중성자(中性子) 및 감마선(線)에 대한 선량율(線量率) 환산인자(換算因子) 계산(計算))

  • Kwon, Seog-Guen;Lee, Soo-Yong;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.6 no.1
    • /
    • pp.8-24
    • /
    • 1981
  • This paper presents flux-to-dose-rate conversion factors for neutrons and gamma rays based on the American National Standard Institute(ANSI) N666. These data are used to calculated the dose rate distribution of neutron and gamma ray in radiation fields. Neutron flux-to-dose-rate conversion factors for energies from $2.5{\times}10^{-8}$ to 20 MeV are presented; the corresponding energy range for gamma rays is 0.01 to 15 MeV. Flux-to-dose-rate conversion factors were calculated, under the assumption that radiation energy distribution has nonlinearity in the phantom, have different meaning from those values obtained by monoetiergetic radiation. Especially, these values were determined with the cross section library. The flux-to-dose-rate conversion factors obtained in this work were in a good agreement to the values presented by ANSI. Those data will be a useful for the radiation shielding analysis and the radiation dosimetry in the case of continuous energy distributions.

  • PDF

The Study on the Reduction of Patient Surface Dose Through the use of Copper Filter in a Digital Chest Radiography (디지털 흉부 촬영에서 구리필터사용에 따른 환자 표면선량 감소효과에 관한 연구)

  • Shin, Soo-In;Kim, Chong-Yeal;Kim, Sung-Chul
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.223-228
    • /
    • 2008
  • The most critical point in the medical use of radiation is to minimize the patient's entrance dose while maintaining the diagnostic function. Low-energy photons (long wave X-ray) among diagnostic X-rays are unnecessary because they are mostly absorbed and contribute the increase of patient's entrance dose. The most effective method to eliminate the low-energy photons is to use the filtering plate. The experiments were performed by observing the image quality. The skin entrance dose was 0.3 mmCu (copper) filter. A total of 80 images were prepared as two sets of 40 cuts. In the first set (of 40 cuts), 20 cuts were prepared for the non-filter set and another 20 cuts for the Cu filter of signal + noise image set. In the second set of 40 cuts, 20 cuts were prepared for the non-filter set and another 20 cuts for the Cu filter of non-signal image (noisy image) with random location of diameter 4 mm and 3 mm thickness of acryl disc for ROC signal at the chest phantom. P(S/s) and P(S/n) were calculated and the ROC curve was described in terms of sensitivity and specificity. Accuracy were evaluated after reading by five radiologists. The number of optically observable lesions was counted through ANSI chest phantom and contrast-detail phantom by recommendation of AAPM when non-filter or Cu filter was used, and the skin entrance dose was also measured for both conditions. As the result of the study, when the Cu filter was applied, favorable outcomes were observed on, the ROC Curve was located on the upper left area, sensitivity, accuracy and the number of CD phantom lesions were reasonable. Furthermore, if skin entrance dose was reduced, the use of additional filtration may be required to be considered in many other cases.

  • PDF

The Effects of Image Quality due to Scattering X-ray according to increasing Patient Thickness (피사체 두께에 따른 산란선 발생이 화질에 미치는 영향)

  • Park, Ji-Koon;Yang, Sung-Woo;Jun, Jae-Hoon;Cho, Su-Yeon;Kim, Kyo-Tae;Heo, Ye-Ji;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.671-677
    • /
    • 2017
  • In this study, scattering factors affecting the quality of medical images were quantitatively analyzed and investigated. MCNPX simulation was conducted by using ANSI phantom, made of tissue equivalent materials, to calculate the scattering ratio occurred by the increase of the object thickness. Then, the result of the simulation was compared with the result of actual radiation measurement. In addition, we evaluated the image quality by the RMS evaluation, RSD and NPS analysis using X-ray images acquired with increasing object thickness. Furthermore, the scattering ratio was analyzed by increasing the thickness of acrylic phantom on chest phantom. The result showed that the scattering ratio was increased to 57.2%, 62.4%, and 66.8% from 48.9%, respectively, when the acrylic phantom thickness was increased by 1 inch from 6.1 inches. The results of MCNPX simulation and the actual measured scattering dose showed similar results. Also, as a result of RMS measurement from acquired x-ray images, the standard deviation decreased as the object thickness increased. However, in the RSD analysis considering the average incident dose, the results were increased from 0.028 to 0.039, 0.051, 0.062 as the acrylic phantom thickness was increased from 6.1 inches to 7.1 inch, 8.1 inch, and 9.1 inch, respectively. It can be seen that the increase of the scattering effect due to the increase of the object thickness reduces the SNR. Also, the NPS results obtained by measuring scattered radiation incident on the detector resulted in the increase of the noise as the object thickness increased.

The Relative and Absolute Speed of Radiographic Screen-Film Systems (증감지(增感紙)-필름계(系)의 상대감도(相對感度)와 절대감도(絶對感度)에 관한 실험(實驗))

  • Huh, Joon;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.16 no.1
    • /
    • pp.67-80
    • /
    • 1993
  • Recently, a large number of new screen-film systems have become available for use in diagnostic radiology. These new screens are made of materials generally known as rare-earth phosphors which have high x-ray absorption and high x-ray to light conversion efficiency compared to calcium tungstate phosphors. The major advantage of these new systesms is reduction of patient exposure due to their high speed or high sensitivity. However, a system with excessively high speed can result in a significant degradation of radiographic image quality. Therefore, th speed is important parameters for users of these system. Our aim of in this was to determine accurately and precisely the absolute speed and relative speeds of both new and conventional screen-film system. We determined the absolute speed in condition of BRH phantom beam qulity and the relative speed were measured by a split-screen technique in condition of BRH and ANSI phantom beam qulity. The absolute and the relative speed were determined for 8 kinds of screen-4 kinds of film in regular system and 7 kinds of screen-7 kinds of film in ortho system. In this study we could know the New Rx, T-MAT G has the highest film speed, also know Green system's stndard deviation of relative speed larger than blue system. It was realized that there were no relationship between the absolute speed and the blue system. It was realized that there were no relationship between the absolute speed and the relative speed in ortho or regular system.

  • PDF