• Title/Summary/Keyword: AIR VOLUME

Search Result 2,282, Processing Time 0.026 seconds

Numerical study on the flow characteristics in Air-conditioner duct of EMU (전동차 공조기 덕트 내의 유동특성에 관한 수치해석적 연구)

  • Kim Seung-Tech;Kim Sung-Jong;Park Geun-Soo;Park Hyung-Soon
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.345-350
    • /
    • 2003
  • The inside of EMU is supplied with the cooling air from air-conditioner and the fresh air from exterior through the air-conditioner duct which is one of the air conditioning system. The shape of air-conditioner duct is a major factor in determining the air-conditioning efficiency, thermal comfort and energy efficiency. Therefore, this study is to understand the flow characteristics in the air-conditioner duct by three dimensional numerical simulation. The air-conditioner duct was calculated for the design volume flow rate, $2,726\;m^3/h/unit$. From the result of calculation and measurement, the velocity at diffuser outlet presented good agreement in general. [n this present study, the calculation was also performed for three volume flow rate(1,800, 2,200, 3,000 $m^3/h/unit$) and total pressure characteristic curve with volume flow rate was presented.

  • PDF

서울시내 극장내 공기조사 성적 (제4보) (극장환기에 대한 고찰)

  • 권숙표
    • YAKHAK HOEJI
    • /
    • v.2 no.1_2
    • /
    • pp.33-41
    • /
    • 1953
  • According to the results of the investigation of air condition on a movie hause in Seoul city, for the period August 1948 to August 1949, the results were considerable condition contrary to the expection due to lack of Ventilation. By the above equation, the total air ventilation volume, the avarage air volume of natural ventilation, and the air volume of artifical ventilation to be required of the seven movie hause in Seoul city are discussed (See table in page in this Journal)

  • PDF

A study on the Behavior of Fine Particle used the HEPA Filer (HEPA Filter를 이용한 미세입자 거동에 관한 연구)

  • Kim, Won-Gang
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.3
    • /
    • pp.16-27
    • /
    • 2009
  • In this paper, I examined the level of fine dust in medical institutions, educational institutions and multi-purposed facilities to grasp the exact state of the present, and decided the level of air-borne particulate(KSM ISO Standard and ISO Standard 14644-1). We compared new proposed cleaner equipped with HEPA Filter with general cleaner and analyzed the rate of removal according to height, air volume and the equipment with the compulsive air intake. Through this comparison, I reached the conclusion as follows: 1. According to the examination, the fine dust of medical institutions, educational institutions and multi-purposed facilities in Kwang Ju is class 9. 2. The filter used in general cleaner on the market is that of HEPA-type, and its removal efficiency for fine particles($0.3{\sim}0.5{\mu}m$) is very low. 3. In the removal efficiency of new proposed cleaner equipped with HEPA Filter, the higher it is, the better, especially more than 180cm in height. 4. In case it is operated for 5 minutes under the condition of the space of $9.4m^{3}$ and the maximum air volume equipped with two induction pipes, we can keep the air cleanness level of 5 ~ 6. 5. To maintain the air cleanness for a long time, if we first operate for 5 minutes at maximum air volume and then operate at medium maximum air volume, we can keep the air cleanness with low energy.

Accuracy Evaluation of Open-air Compost Volume Calculation Using Unmanned Aerial Vehicle (무인항공기를 이용한 야적퇴비 적재량 산정 정확도 평가)

  • Kim, Heung-Min;Bak, Su-Ho;Yoon, Hong-Joo;Jang, Seon-Woong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.3
    • /
    • pp.541-550
    • /
    • 2021
  • While open-air compost has value as a source of nutrients for crops in agricultural land, it acts as a pollution that adversely affects the environment during rainfall, and management is required. In this study, it was intended to analyze the accuracy of calculating open-air compost volume using fixed-wing UAV (unmanned aerial vehicle) capable of acquiring a wide range of images and automatic path flights and to identify the possibility of utilization. In order to evaluate the accuracy of calculating the three open-air compost volume, ground LiDAR surveys and precision surveys using a rotary UAV were performed. and compared with the open-air compost volume acquired through a fixed-wing UAV. As a result of comparing the calculation of open-air compost volume based on the ground LiDAR, the error rate of the rotary-wing was estimated to be ±5%, and the error rate of fixed-wing was -15 ~ -4%. one of three open-air compost volume calculated by fixed-wing was underestimated as about -15 %, but the deviation of the open-air compost volume was 2.9 m3, which was not significant. In addition, as a result of periodic monitoring of open-air compost using fixed-wing UAV, changes in the volume of open-air compost with time could be confirmed. These results suggested that efficient open-air compost monitoring and non-point pollutants in agricultural for a wide range using fixed-wing UAV is possible.

Energy Saving Potential and Indoor Air Quality Benefits of Multiple Zone Dedicated Outdoor Air System

  • Lee, Soo-Jin;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.1
    • /
    • pp.71-82
    • /
    • 2019
  • The purpose of this study is to evaluate the indoor air quality (IAQ) and energy benefits of a dedicated outdoor air system (DOAS) and compare them with a conventional variable air volume (VAV) system. The DOAS is a decoupled system that supplies only outdoor air, while reducing its consumption using an enthalpy wheel. The VAV system supplies air that is mixed outdoor and transferred indoor. The VAV has the issue of unbalanced ventilation in each room in multiple zones because it supplies mixing air. The DOAS does not have this problem because it supplies only outdoor air. That is, the DOAS is a 100% outdoor air system and the VAV is an air conditioning system. The transient simulations of carbon dioxide concentration and energy consumption were performed using a MATLAB program based on the thermal loads from the model predicted by the TRNSYS 18 program. The results indicated that when the air volume is large, such as in summer, the distribution of air is not appropriate in the VAV system. The DOAS however, supplies the outdoor air stably. Moreover, in terms of annual primary energy consumption, the DOAS consumed approximately 40% less energy than the VAV system.

Consideration of Heat Recovery Ventilator from Ventilating Standpoint (환기관점에서 본 열교환 환기유니트)

  • Song, Jun-Won;Kang, Il-Kyung;Kim, Tae-Hee;Shin, Yong-Sup;Park, Jae-Sung;Choi, Won-Young
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.417-422
    • /
    • 2006
  • On trends of 'well-being', heat recovery ventilators(HRV) are recently installed in high rise buildings. HRV is not energy saving instrument but ventilating one. But many people have not been aware of the accurate fact. In this study, performances of HRV are tested under foreign and domestic standards. Especially air-tightness is measured three times by using gas concentration method and pressing equipment. Wet effective ventilating air volume is acquired by solving gas concentration equations. After research air-tightness and effective ventilating air volume must be more focused on than heat transfer efficiency to select the optimal HRV. Heat transfer efficiency must be adjusted by air-tightness results.

  • PDF

A Study on the Application of VAV/BPFS(Variable-Air-Volume/Bypass Filtration System) for Indoor Air Environment (VAV/BPFS(Variable-Air-Volume/Bypass Filtration System) 의 실내환경 적응에 관한 연구)

  • 최성우
    • Journal of Environmental Science International
    • /
    • v.12 no.12
    • /
    • pp.1235-1243
    • /
    • 2003
  • Under controlled conditions in an environmental chamber, 24 experiments were performed to compare the ability of a Variable-Air-Volume/Bypass Filtration System(VAV/BPFS) to remove indoor pollutants and to conserve energy with the ability of conventional Variable Air Volume(VAV) system. The specific conclusions of this paper were; first, the VAV/BPFS was more efficient than the VAV system in removing particulate matter, TVOC, and target VOCs. The total effective removal rate of PM for the VAV/BPFS was two times as high as that of the VAV system. The total effective removal rate of TVOC for the VAV/BPFS was 20 percent higher than that of the VAV system. Also each target VOC concentration was reduced by using the VAV/BPFS. Second, clean air delivery rate was increased by using VAV/BPFS due to additional filtration rate. Otherwise, the VAV/BPFS decreased outdoor supply air rate above 25 percent relative to the rate of VAV system. Third, total energy consumption by the VAV/BPFS was lower than that of the VAV system during the period with indoor thermal load, occupied time. The energy saving of the VAV/BPFS ranged from 11 to 16 percent. The VAV/BPFS improves indoor air quality more efficiently than the VAV system, and it reduced energy consumption. Retrofitting the VAV system with the VAV/BPFS was easy The use of VAV/BPFS is, therefore, recommended far buildings with VAV system as well as for buildings at designing stage.

Effective Volume of the Korea Research Institute of Standards and Science Free Air Chamber L1 for Low-Energy X-Ray Measurement

  • Chul-Young Yi;Yun Ho Kim;Don Yeong Jeong
    • Progress in Medical Physics
    • /
    • v.33 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • Purpose: To evaluate the effective volume of the Korea Research Institute of Standards and Science free air chamber (KRISS FAC) L1 used for the primary standard device of the low-energy X-ray air kerma. Methods: The mechanical dimensions were measured using a 3-dimensional coordinate measuring machine (3-d CMM, Model UMM 500, Carl Zeiss). The diameter of the diaphragm was measured by a ring gauge calibrator (Model KRISS-DM1, KRISS). The elongation of the collector length due to electric field distortion was determined from the capacitance measurement of the KRISS FAC considering the result of the finite element method (FEM) analysis using the code QuickField v6.4. Results: The measured length of the collector was 15.8003±0.0014 mm with a 68% confidence level (k=1). The aperture diameter of the diaphragm was 10.0021±0.0002 mm (k=1). The mechanical measurement volume of the KRISS FAC L1 was 1.2415±0.0006 cm3 (k=1). The elongated length of the collector due to the electric field distortion was 0.170±0.021 mm. Considering the elongated length, the effective measurement volume of the KRISS FAC L1 was 1.2548±0.0019 cm3(k=1). Conclusions: The effective volume of the KRISS FAC L1 was determined from the mechanically measured value by adding the elongated volume due to the electric field distortion in the FAC. The effective volume will replace the existing mechanically determined volume in establishing and maintaining the primary standard of the low-energy X-ray.

A Study on the Improvement of Accuracy in Mapping the Distribution of the Emission Volume of Air Pollution Using GIS (GIS를 이용한 대기오염 배출량 분포도의 정확도 향상에 관한 연구)

  • 최진무
    • Spatial Information Research
    • /
    • v.6 no.1
    • /
    • pp.65-76
    • /
    • 1998
  • Air contaminant density must be inferred exactly to manage air pollution. Each land use of air pollution source is duplicated in the existing air contaminant distribution because the resolution of the land use map is low. The purpose of this study is to understand how the land use map is used to determine effectively in the distribution calculation of the emission volume and the inference of air contaminant density, as it is made in a high resolution. The major findings are as follows : In this study, as to making a high resolution($28.5m{\times}28.5m$) map of land use with GIS, each air pollution source is not duplicated spatially and land use can be reflected effectively. In Seoul, each air contaminant density was inferred (using a TCM-2 model) with the existing distribution map of emission volume, whose resolution is $1km{\times}1km$, and the new distribution map of emission volume, whose resolution is $28.5km{\times}28.5km$. According to the result, the inference value of the new distribution map was more similar to the actual value of an automatic survey network.

  • PDF

A Study on the Factors Affecting Air Cargo Volume Using Time Series Data : Focusing on Incheon-Shanghai, Guangzhou, Tianjin, and Beijing (시계열 데이터를 활용한 항공 화물 물동량 영향 요인에 관한 연구 : 인천-상하이, 광저우, 톈진, 베이징을 중심으로)

  • Sin, Seung-Youn;Moon, Seung-Jin;Park, In-Mu;Ahn, Jeong-Min;Ha, Yong-Hee
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.43 no.4
    • /
    • pp.15-22
    • /
    • 2020
  • Economic indicators are a factor that affects air cargo volume. This study analyzes the different factors affecting air cargo volume by each Chinese cities according to the main characteristics. The purpose of this study is to help companies related to China, airlines, and other stakeholders predict and prepare for the fluctuations in air cargo volume and make optimal decisions. To this end, 20 economic data were used, and the entire data was reduced to 5 dimensions through factor analysis to build a dataset necessary and evaluated the influencing factors by multi regression. The result shows that Macro-Economic Indicators, Production/Service indicators are significant for every cities and Chinese manufacture/Customer indicators, Korean manufacture/Oil Price indicators, Trade/Current indicators are significant for each other city. All adjusted R2 values are high enough to explain our model and the result showed excellent performance in terms of analyzing the different factors which affects air cargo volume. If companies that are currently doing business with China can identify factors affecting China's cargo volume, they can be flexible in response to changes in plans such as plans to enter China, production plans and inventory management, and marketing strategies, which can be of great help in terms of corporate operations.