• Title/Summary/Keyword: AIR 모델

Search Result 2,267, Processing Time 0.035 seconds

A Study on Flame Dynamics and Combustion Instability Stabilized with a V-gutter Type Flameholder in a model ramjet combustor (V-gutter 형 보염기를 장착한 모델 램제트 연소기의 화염 특성 및 연소 불안정 연구)

  • Song, Jin-Kwan;Hwang, Jeong-Jae;Song, Jae-Cheon;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.447-448
    • /
    • 2008
  • The goal of this study is to find flame dynamic behavior using a transverse fuel injection in a model combustor, and is to investigate main causes of unstable combustion in a liquid-fueled combustor. For transverse fuel injection into air cross flow, spray result shows similar tendency with Wu et al.[1998] until spray arrives at flame-holder. However, passing through flame-holder, fuel inflow into recirculation region of flameholder is not sufficient so it makes large difference between shear flame and recirculation flame behind flameholder. In combustion tests, the stable flame shows a kind of shear flames and low peaks of dynamic pressure frequencies. On the other hand, unstable flame shows periodic detached flame in recirculation zone and a strong peak of dynamic pressure frequency. The instability frequency is highly affected by influx air velocity, air temperature, equivalence ratio and wake or vortex shedding frequency behind the flameholder.

  • PDF

A Study on an Operation Mode of a Rotary-type Small-scaled LIM for Railway Transit (철도차량용 회전형 축소모델 선형유도전동기의 운전모드 연구)

  • Park, Chan-Bae;Lee, Byung-Song;Lee, Hyung-Woo;Kwon, Sam-Young;Park, Hyun-June;Han, Kyung-Hee
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.310-315
    • /
    • 2008
  • Authors design a rotary-type small-scaled linear induction motor(LIM) and a performance test machine before manufacturing a real-scaled LIM for a railway transit. The designed LIM is a single-sided, short primary type and its primary has 4 poles. The rated power is 10(kW). In order to analyze characteristics of the LIM, authors use a mixed 2D-3D FEM analysis. 3-D FEM analysis is used for calculating a distribution of eddy-current on the semi-caped AL-sheet of the secondary reaction. Authors calculate a correction factor of conductivity and an equivalent conductivity on the secondary AL-sheet using a normalized eddy-current. The equivalent conductivity which is calculated in this way includes a transverse edge-effect of the LIM. Authors apply the equivalent conductivity on the secondary AL-sheet of 2D-FEM model and get performance characteristics of the LIM. Basic characteristics such as thrust and normal force, input current, efficiency and power factor of the LIM have been analyzed with the variation of frequency and speed. In order to apply an air-gap control system, the variation of the basic characteristics have been analyzed with the air-gap length variation of the LIM. Finally, authors introduce an operation mode using the air-gap control system and conduct a research on feasibility of the system.

  • PDF

A Study on the Numerical Analysis of VOCs Emission from Plywood Floor Material (수치해석을 활용한 합판마루 바닥재의 VOCs 방출에 관한 연구)

  • Kim Ji-Hye;Kang Dong-Hwa;Choi Dong-Hee;Kim Sun-Sook;Yeo Myoung-Souk;Kim Kwang-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1123-1131
    • /
    • 2005
  • The floor material is known as the most influential emission source of the residential building, because most floor material is made of wood compound and adhesive like a plywood flooring. Moreover, floor heating system keeps the inside temperature of the material high. As the emission of hazardous chemical compound from the construction material is influenced by many factors, it is necessary to analyze the emission characteristics of the floor material to improve IAQ. In this study, numerical analysis is performed to investigate the emission characteristics of the floor material affected by several factors such as temperature, air exchange rate, initial concentration, and internal diffusion coefficient. A simulation program is also written based on the mass transfer theory. The simulation results show that there is some level of difference on the TVOC concentration when each of the factors is variable.

A Prediction of Pollutant Emission Rate using Numerical Analysis and CFD in Double-Layered Building Materials (수치해석 및 CFD를 이용한 소형챔버내 복합건축자재의 오염물질 방출량 예측)

  • Kim, Chang-Nam;Leigh, Seung-Bok;Kim, Tae-Yeon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.277-282
    • /
    • 2006
  • In order to predict the indoor air pollutant, the VOCs emission rate is used through small chamber in the design process. However, the small chamber method has limitations as the convective mass transfer coefficient, the most important factor when predicting VOCs contamination of indoor air, is different between the small chamber result and the measured data in the actual building. Furthermore, the existing studies which analyzed mass transfer coefficient in the small chamber were directed on the small chambers developed at the time and FLEC(Field and Laboratory Emission Cell), thus, are different from the current small chamber which has been changed with improvements. The purpose of this study is to determine the emission rate of pollutant in double-layered building materials through the CFD(Computational of Fluid Dynamics) and Numerical analysis based on the mass transfer coefficient on singled-layered building material by using the current small chamber widely used in Korea. Futhermore, this study used the new convective mass transfer coefficient($h_m'$) which indicates the existing convective mass transfer coefficient($h_m$) including VOC partition coefficient(k). Also, formaldehyde was selected as target pollutant.

  • PDF

Multi-functional Fighter Radar Scheduling Method for Interleaved Mode Operation of Airborne and Ground Target (전투기탑재 다기능 레이다의 공대공 및 공대지 동시 운용 모드를 위한 스케줄링 기법)

  • Kim, Do-Un;Lee, Woo-Cheol;Choi, Han-Lim;Park, Joontae;Park, Junehyune;Seo, JeongJik
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.7
    • /
    • pp.581-588
    • /
    • 2021
  • This paper deals with a beam scheduling method in fighter interleaving mode. Not only the priority of tasks but also operational requirements that air-to-ground and air-to-air search tasks should be executed alternatively are established to maximize high-quality of situational awareness. We propose a real-time heuristic beam scheduling method that is advanced from WMDD to satisfies the requirements. The proposed scheduling method is implemented in a simulation environment resembling the task processing mechanism and measurement model of a radar. Performance improvement in terms of task delay time is observed.

Power consumption prediction model based on artificial neural networks for seawater source heat pump system in recirculating aquaculture system fish farm (순환여과식 양식장 해수 열원 히트펌프 시스템의 전력 소비량 예측을 위한 인공 신경망 모델)

  • Hyeon-Seok JEONG;Jong-Hyeok RYU;Seok-Kwon JEONG
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.60 no.1
    • /
    • pp.87-99
    • /
    • 2024
  • This study deals with the application of an artificial neural network (ANN) model to predict power consumption for utilizing seawater source heat pumps of recirculating aquaculture system. An integrated dynamic simulation model was constructed using the TRNSYS program to obtain input and output data for the ANN model to predict the power consumption of the recirculating aquaculture system with a heat pump system. Data obtained from the TRNSYS program were analyzed using linear regression, and converted into optimal data necessary for the ANN model through normalization. To optimize the ANN-based power consumption prediction model, the hyper parameters of ANN were determined using the Bayesian optimization. ANN simulation results showed that ANN models with optimized hyper parameters exhibited acceptably high predictive accuracy conforming to ASHRAE standards.

Natural Convection in a Rectangular Enclosure with Localized Heating from Below (사각공간내에서의 부분바닥가열에 의한 자연대류에 관한 연구)

  • Han, H.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.287-297
    • /
    • 1995
  • In this study, the geometry consists of a two-dimensional rectangular enclosure with localized heating from below. The size and the location of the heater on the floor has been varied, and one of the vertical walls remains at a low temperature simulating a cold window. The governing equations for momentum, energy and continuity, which are coupled with turbulent equations have been solved using a finite volume method. A low Reynolds number $k-{\varepsilon}$ model has been incorporated to solve the turbulent kinetic energy and the dissipation rate. The heat transfer characteristics and the thermal environmental characteristics of the room have been obtained for various system parameters in a room with a partially heated floor.

  • PDF

Frost Formation in a Straight Duct under Turbulent Flow (난류 유동 하에서 덕트 내의 착상)

  • Yang, Dong-Keun;Lee, Kwan-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1114-1121
    • /
    • 2003
  • A mathematical model considering the air side and the frost layer is presented to predict the frost layer growth. The standard k-$\varepsilon$ model for the air flow and the diffusion and energy equations for the frost layer are employed. The numerical results are compared with experimental data to validate the present model, and agree well with experimental data within a maximum error of 10%. The present model predicts well the frost properties and heat and mass transfer with respect to the frosting time. The variation of total heat transfer strongly depends on the operating condition, and has a similar trend to that of the sensible heat transfer. The frost properties along the flow direction are also investigated.

Numerical Analysis of Ignition and Flame Propagation in the Air/Fuel Spray Mixture (공기/연료분무 혼합기의 점화 및 화염전파 해석)

  • ;;Kim, Sung-Jun
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.12
    • /
    • pp.3352-3359
    • /
    • 1995
  • An Eulerian-Lagrangian method is employed to simulate the ignition process and the flame propagation through the air/fuel spray mixture in a closed constant-volume combustor. The spray mixture is ignited by providing a hot wall at the end of the combustor or by firing the electric spark. The investigated parameters involve the initial droplet size, overall equivalence ratio, initial fuel vapor concentration, distance between the hot wall and the nearest droplet, and the ignition energy. Numerical results clearly show the existence of the optimum spray condition for minimizing the ignition energy and the ignition delay time as well as the critical dependence of ignition upon the distance of the heat source to the nearest droplet.

The application of passive sampler for the evaluation of air quality in a metropolitan city (대도시 대기질 공간분포 해석을 위한 Passive sampler의 활용)

  • 박민수;김선태;인치경;이범진;손찬웅;정재호
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.337-338
    • /
    • 2003
  • 대도시의 대기질은 1960년대 이후 지속되어온 국토개발과 성장위주의 경제모델이 각 도시 지형적 특성을 고려하지 못한 채 일률적으로 적용되면서 점차 심화되어 가고 있는 실정이다. 특히 1990년대 이후 연료정책 등 가시적인 효과를 거두고 있는 황산화물(SOx)도 도시권의 일부 지역에서는 인구유입에 따른 주택건설, 산업시설과 교통시설의 확충 등으로 절대량에 있어서 점차 증가추세를 나타내고 있다. 이러한 대도시에서의 대기질 현상을 규명할 수 있는 가장 객관적인 방법은 자동측정망의 활용이라 할 수 있으나, 수도권을 제외한 대도시에서의 대기측정망 수는 운영비용, 지역면적 및 인구밀도 등을 고려 할 때 현실적으로 부족한 실정이다. (중략)

  • PDF