• 제목/요약/키워드: AHU

검색결과 59건 처리시간 0.026초

에어핸들링 유닛의 공기정화용 전기집진기의 방전극 비교 (Comparison of discharging electrodes for the electrostatic precipitator as an air filtration system in air handling units)

  • 신동호;우창규;김학준;김용진;한방우
    • 한국입자에어로졸학회지
    • /
    • 제13권1호
    • /
    • pp.11-16
    • /
    • 2017
  • Indoor air quality is of increasing concern because it is closely related human health. An air handling unit (AHU) can be used to control the indoor air quality related to particulate matters and $CO_2$ as well as air conditioning such as temperature and humidity of indoor air. An electrostatic precipitator has a high collection efficiency and low pressure drop, however, ozone can possibly generate from its chargers, which is one of drawbacks to apply it for indoor air control. Here we compared four charging electrodes such as a $50{\mu}m$ tungsten wire, a $100{\mu}m$ tungsten wire, a $16{\mu}m$-thickness Al foil and a carbon fabric comprised of $5-10{\mu}m$ fibers. The carbon fabric electrode showed a superior particle collection efficiency and a lower ozone generation at a given power consumption compared to tungsten wires of 50, $100{\mu}m$ and an Al foil electrode. This low ozone generating, micro-sized electrode can be applied to the electrostatic precipitator in AHU for indoor air control.

공기조화기 장착용 축상유입식 싸이클론의 압력손실에 대한 수치해석 및 실험적 연구 (Numerical and experimental study on the pressure dorp of axial-flow cyclone in the air handling unit)

  • 권순박;박덕신;조영민;김세영;김명준;김호중;김태성
    • 한국입자에어로졸학회지
    • /
    • 제5권2호
    • /
    • pp.37-43
    • /
    • 2009
  • Particulate matter (PM) is one of the major indoor air pollutants especially in the subway station in Korea. In order to remove PM in the subway station, several kinds of PM removal system such as roll-filter, auto-washable air filter, demister, and electrostatic precipitator are used in the air handling unit (AHU) of subway stations. However, those systems are prone to operation and maintenance problems since the filter-regeneration unit consisting of electrical or water jet parts might malfunction due to the high load of particulates unless the filter medium is periodically replaced. In this study, the use of axial-flow cyclone was proposed for particulate filter unit in the AHU for its low operation and maintenance cost. Novel shape of axial-flow cyclone was designed by using computational fluid dynamics (CFD). The shape of vortex vane was optimized in terms of pressure drop and tangential velocity. In addition, CFD analysis was validated experimentally through the pressure drop measurement of mock-up model. We found that pressure drop and tangential velocity of fluid through the axia-flow cyclone was significantly affected by the rotating degree of vortex vane and the numerical prediction of pressure drop agreed well with experimental measurement.

  • PDF

인공토양기반 식생바이오필터의 AHU(Air Handling Unit) 연계를 통한 적용식물의 생육지표 분석 (Analysis of Growth Indicators of Applied Plants by AHU(Air Handling Unit)-linking with Artificial Soil-based Vegetation Bio-filters)

  • 김태한;이소담;안병렬
    • 한국환경복원기술학회지
    • /
    • 제21권3호
    • /
    • pp.99-110
    • /
    • 2018
  • Compared to yellow dust coming from China or particulate matter created naturally in spring due to Total Suspended Particulate(TSP), particulate matter in winter season have much more serious effect on human body as they penetrate cell membranes. Although such particulate matter are becoming a social issue, there are no concrete plans on how to reduce them. Air-purifying plants are limited in maintaining the indoor air quality of large area because it is usually difficult to quantify their performance. In order to improve this, a bio-filter that can be connected to air conditioner is suggested as an option. This study seeks to improve air conditioning model-based monitoring method for bio-filters from prior studies and objectify correlations between applied vegetation and growing environment into quantitative indicators. By doing so, this study seeks to provide criteria on plants applied to artificial soil-based vegetation bio-filters and basic information to set air-conditioning features. The study results confirmed significant tendency on the growing stability of each purifying plant in mechanical air-conditioning environment. Among three models selected for bio-filter vegetation models, epipremnum aureum showed high performance in quantitative indicators, including soil moisture, EC, and leaf temperature, etc., indicating that it would assure the highest growing stability in this test air-conditioning environment.

3-DCS를 이용한 자동차 공기 분배장치의 도아 구동 기구의 공차 적합성 분석에 대한 연구 (Study of Tolerance Suitability of Door Operation Mechanism on Mobile Air Handing Unit Using 3-DCS Analysis)

  • 김종수;이대웅
    • 한국자동차공학회논문집
    • /
    • 제24권5호
    • /
    • pp.527-537
    • /
    • 2016
  • Recent automakers are trying to be more precise with the dimension check and moving parts to guarantee high quality and satisfy customer requirements. The aim of this paper is to investigate the design tolerance suitability of door operating mechanism linked arms, lever, and cam-shaft in a mobile air handling unit. These parts are complicated because doors, arms, lever and cam-shaft are connected nonlinearly in 3D. The current tolerance analysis method poses problems in design analysis because the moving doors are reasonably suitable for the AHU function. The 3-DCS analysis method provided useful results not only in establishing the inspection criteria for the quality control of products but also in enabling economical production. As a result, the vent door had $1.62^{\circ}{\sim}1.72^{\circ}$ and the defrost door had $0.84^{\circ}{\sim}0.9^{\circ}$ for the directly connected arms operating-type. For the lever connected arm operating-type, the foot door had $2.0^{\circ}{\sim}2.24^{\circ}$ tolerance, while the tolerance values satisfied the air flow volume distribution rate criteria in the AHU. Finally, the results have confirmed the design's tolerance suitability by using 3-DCS analysis at the early design stages. Reliability can be achieved by analyzing accumulated tolerance during the sub-parts assembly process and the moving mechanism linked especially by arms, lever, and cam-shaft.

건물 냉방시스템의 예측제어를 위한 인공신경망 모델 개발 (Development of an Artificial Neural Network Model for a Predictive Control of Cooling Systems)

  • 강인성;양영권;이효은;박진철;문진우
    • KIEAE Journal
    • /
    • 제17권5호
    • /
    • pp.69-76
    • /
    • 2017
  • Purpose: This study aimed at developing an Artificial Neural Network (ANN) model for predicting the amount of cooling energy consumption of the variable refrigerant flow (VRF) cooling system by the different set-points of the control variables, such as supply air temperature of air handling unit (AHU), condenser fluid temperature, condenser fluid pressure, and refrigerant evaporation temperature. Applying the predicted results for the different set-points, the control algorithm, which embedded the ANN model, will determine the most energy efficient control strategy. Method: The ANN model was developed and tested its prediction accuracy by using matrix laboratory (MATLAB) and its neural network toolbox. The field data sets were collected for the model training and performance evaluation. For completing the prediction model, three major steps were conducted - i) initial model development including input variable selection, ii) model optimization, and iii) performance evaluation. Result: Eight meaningful input variables were selected in the initial model development such as outdoor temperature, outdoor humidity, indoor temperature, cooling load of the previous cycle, supply air temperature of AHU, condenser fluid temperature, condenser fluid pressure, and refrigerant evaporation temperature. The initial model was optimized to have 2 hidden layers with 15 hidden neurons each, 0.3 learning rate, and 0.3 momentum. The optimized model proved its prediction accuracy with stable prediction results.

점진적 샘플링과 정규 상호정보량을 이용한 온라인 기계학습 공조기 급기온도 예측 모델 개발 (Development of Online Machine Learning Model for AHU Supply Air Temperature Prediction using Progressive Sampling and Normalized Mutual Information)

  • 추한경;신한솔;안기언;라선중;박철수
    • 대한건축학회논문집:구조계
    • /
    • 제34권6호
    • /
    • pp.63-69
    • /
    • 2018
  • The machine learning model can capture the dynamics of building systems with less inputs than the first principle based simulation model. The training data for developing a machine learning model are usually selected in a heuristic manner. In this study, the authors developed a machine learning model which can describe supply air temperature from an AHU in a real office building. For rational reduction of the training data, the progressive sampling method was used. It is found that even though the progressive sampling requires far less training data (n=60) than the offline regular sampling (n=1,799), the MBEs of both models are similar (2.6% vs. 5.4%). In addition, for the update of the machine learning model, the normalized mutual information (NMI) was applied. If the NMI between the simulation output and the measured data is less than 0.2, the model has to be updated. By the use of the NMI, the model can perform better prediction ($5.4%{\rightarrow}1.3%$).

$L_{ON}W_{ORKS}$를 이용한 공기조화설비 제어네트워크 구축 (A Construction of AHU Control Network by $L_{ON}W_{ORKS}$)

  • 김명호;김유옥;이태봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 D
    • /
    • pp.2675-2677
    • /
    • 2005
  • 공기조화설비의 계장 및 유지관리시에 공사와 조정 등을 간편화하고 로컬 레벨의 표준화 및 시스템간의 상호운용성을 높이기 위하여 공기조화설비 제어 계통도를 지하층(8포인트)과 기준층(15포인트)으로 나누어 설계하고 이것을 개방형 프로토콜인 $L_{ON}W_{ORKS]$를 이용하여 제어네트워크를 구축하였다. 네트워크의 자 디바이스는 뉴런 C로 프로그램 하였으며, 네트워크의 통신은 통신전용 배선공사를 간소화하기 위하여 전력선 통신을 사용하였다. 연구 결과 $L_{ON}W_{ORKS]$ 프로토콜로 각 디바이스들의 자율분산제어가 가능하게 되었고 통신선의 길이와 회선수를 감소시킬 수 있었다.

  • PDF

냉난방 시스템의 이중선형 시스템에 관한 제어기 설계 (A Controller Design of the Bilinear System for HVAC(Heating, Ventilating and Air-conditioning) System)

  • 이정석;강민수;김명호;이기서
    • 한국철도학회논문집
    • /
    • 제3권4호
    • /
    • pp.177-184
    • /
    • 2000
  • In this paper, a HVAC controller which has a bilinear system is designed to control the air temperature in building room and a saving of energy on the HVAC system. For modeling of the HVAC bilinear system, AHU(Air Handling Unit) is modeled on the control of inside-outside air flow using three dampers in a duct. A heat exchanger and the single room are also modeled by the energy conservation law. Under the modeling of the HVAC bilinear system, the control's law of the bilinear HVAC system is derived by Lyapunov's non-linear theory and Deress's the linear feedback laws for bilinear system. In this paper it was proved that the controller of the HVAC bilinear system is able to control the air temperature with a disturbance in order to get a target of temperature in the building room by the computer simulation when the control inputs regulate the air flow rate and a capacity of the heat exchanger.

  • PDF

Kirchhoff-BEM 을 이용한 Plenum Fan 소음해석 (Acoustic Analysis of Plenum Fan using Kirchhoff-BEM)

  • 송우석;장근정;이승배
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.89-93
    • /
    • 2004
  • To numerically construct the sound fields by a plenum fan mostly found in Air-Handling Unit (AHU), the Kirchhoff-BEM approach was applied to the near-field data of a turbo fan. The scattering effects were found to be significant by the plenum box structure for high-frequency components of source. The directivity petterns and sound pressure levels were also dependent upon the helmholts number which must be considered of the design stage for sound reduction program.

  • PDF

HVAC 파라미터 모니터링 시스템에 대한 고찰 (Computer Validation 중심으로) (A Study on HVAC Parameter Monitoring System (Regarding Computer Validation))

  • 김종구
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.90-95
    • /
    • 2008
  • This article presents practical advice regarding the implementation and management of an impeccable Building Management System. The BMS was introduced to the series of computerized systems including manufacturing, storage, distribution, and quality control. Recently revised GMP regulation is requesting an improvement in drug product quality regulatory system by computer system validation. Quality is critical to guarantee the efficacy and the safety of drugs and is approved in the evaluation process after the audit trail application. HVAC parameter monitoring system will record the identity of operators entering or confirming critical data. Authority to amend entered data should be restricted to nominated persons. Any alteration to an entry of critical data should be authorized in advance and recorded with the reason for the change.

  • PDF