• 제목/요약/키워드: AFM tip

검색결과 164건 처리시간 0.024초

탐침형 정보저장 기술을 위한 실리콘 탐침의 나노 마멸 특성에 관한 연구 (Nano-wear Characteristics of Silicon Probe Tip for Probe Based Data Storage Technology)

  • 이용하;정구현;김대은;유진규;홍승범
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.552-555
    • /
    • 2004
  • The reliability issue of the probe tip/recording media interface is one of the most crucial concerns in the Atomic Force Microscope (AFM)-based recording technology. In this work, the tribological characteristics of the probe/media interface were investigated by performing wear tests using an AFM. The ranges of applied normal load and sliding velocity for the wear test were 10 to 50nN and 2 to 20$\mu$m/s respectively. The damage of the probe tip was quantitatively as well as qualitatively characterized by Field Emission Scanning Probe Microscope (FESEM) analysis and calculated based on Archard s wear equation. It was shown that the wear coefficient of the probe tip was in the order of 10$^{-4}$ ~ 10$^{-3}$ , and significant contamination at the end of the probe tip was observed. Thus in order to implement the AFM-based recording technology, tribological optimization of the probe/media interface must be achieved.

  • PDF

AFM Scratching 기법을 이용한 4H-SiC기판상의 Al 박막 초미세 패턴 형성 연구 (Nano-scale Patterning of Al thin film on 4H-SiC using AFM tip Scratching)

  • 안정준;김재형;박예슬;구상모
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.351-351
    • /
    • 2010
  • Nanoscale patterning using an atomic force microscope tip induced scratching was systematically investigated in AI thin film on 4H-SiC. To identify the effects of the scratch parameters, including the tip loading force, scratch speed, and number of scratches, we varied each parameters and evaluated the major parameter which has intimate relationship with the scale of patterns. In this work, we present the successful demonstration of nano patterning of Al thin film on a 4H-SiC substrate using an AFM scratching and evaluated the scratch parameters on Al/4H-SiC.

  • PDF

AFM팁/강유전박막/전극 시스템에서의 스위칭 영역의 형성 (Formation of Switching Zones in an AFM Tip/Ferroelectric Thin Film/BE System)

  • 김상주;신준호;김윤재
    • 대한기계학회논문집A
    • /
    • 제27권6호
    • /
    • pp.849-856
    • /
    • 2003
  • A three-dimensional constitutive model for polarization switching in ferroelectric materials is used to predict the formation of switching zones in an atomic force microscopy(AFM) tip/ferroelectric thin film/bottom electrode system via finite element simulation. Initially the ferrolectric film is poled upward and the bottom electrode is grounded. A strong dc field is imposed on a fixed point of the top surface of the film through the AFM tip. A small switching zone with downward polarization is nucleated and grows with time. It is found that initially the shape of the switched zone is that of a bulgy dagger, but later turn to the shape of a reversed cup with the lower part wider than the upper part. It can also be concluded that the size of switching zones increases with the period of applied electric potential. The present results are qualitatively consistent with experimental observations.

등가강성요소 모델을 이용한 AFM 마이크로캔틸레버의 진동해석 (Vibration Analysis of AFM Microcantilevers Using an Equivalent Stiffness Element Model)

  • 한동희;김일광;이수일
    • 대한기계학회논문집A
    • /
    • 제39권5호
    • /
    • pp.461-466
    • /
    • 2015
  • 원자현미경(AFM)은 마이크로캔틸레버 끝단의 팁이 시료에 다가갈 때 발생하는 팁과 시료 표면 사이의 상호작용을 이용하여 시료의 다양한 특성들을 찾아내는 매우 유용한 도구이다. 본 논문에서는 이러한 AFM 마이크로캔틸레버의 팁과 시료 사이의 상호작용력을 비선형 스프링을 이용하여 동일한 강성을 갖는 요소로 모델링 하였고 유한요소법을 이용하여 시뮬레이션을 수행하였다. 또한 시뮬레이션 결과를 적합직교분해법을 이용하여 분석함으로써 AFM 마이크로캔틸레버의 복잡한 동적 특성을 파악하였으며 이를 같은 방법으로 분석한 실험 결과와 비교하였다. 그 결과 팁과 시료 사이의 상호작용력을 효과적으로 모델링 할 수 있는 방법을 제시하였으며 이러한 상호작용력으로 인해 고차모드의 영향이 증가함을 확인하였다.

접촉모드 AFM의 시스템 분석 및 제어 (Analysis and Control f Contact Mode AFM)

  • 정회원;심종엽;권대갑
    • 한국정밀공학회지
    • /
    • 제15권3호
    • /
    • pp.99-106
    • /
    • 1998
  • Recently, scientists introduced a new type of microscope capable of investigating nonconducting surfaces in an atomic scale, which is called AFM (Atomic Force Microscope). It was an innovative attempt to overcome the limitation of STM (Scanning Tunnelling Microscope) which has been able to obtain the image of conducting surfaces. Surfaces of samples are imaged with atomic resolution. The AFM is an imaging tool or a profiler with unprecedented 3-D resolution for various surface types. The AFM technology, however, leaves a lot of room for improvement due to its delicate and fragile probing mechanism. One of the room for improvements is gap control between probe tip and sample surface. Distance between probe tip and sample surface must be kept in below one Angtrom in order to measure the sample surface in Angstrom resolution. In this paper, AFM system modeling, experimental system identification and control scheme based on system identification are performed and finally sample surface is measured by home-built AFM with such a control scheme.

  • PDF

AFM을 이용한 데이터 저장 소자 연구 (A Study of Data Storage Device Utilizing AFM technology)

  • 최정환;박근형
    • 한국전기전자재료학회논문지
    • /
    • 제19권5호
    • /
    • pp.411-416
    • /
    • 2006
  • A new reading technology for the ultra-high density data storage device utilizing AFM technology was proposed and its experimental results were discussed in this paper. For the experiments, an about $2{\mu}m$ thick conductive polymer layer was spin-coated on the heavily doped n-type Si wafer and an about $0.1{\mu}m$ thick PMMA layer was also been spin-coated on it. After then, the $5{\times}5$ memory way was fabricated by making indents on the surface of the wafer with the heated AFM tip, and the data reading was performed by scanning the surface with the tip biased at 10 V and the measuring the current flowing out at the end of the tip. The experimental results clearly showed that the new data reading technology worked superbly. The current measured was about 0.92 pA at the cell with the indent, and it was not only below 0.31 pA at the cell without the indent, but also at the cell where the indent was erased.

AFM을 이용한 MEMS/NEMS 공정용 재료의 트라이볼로지 특성에 관한 연구 (A Study on Tribological Characteristics of Materials for MEMS/NEMS Using Chemically Modified AFM tip)

  • 허정철;김광섭;김경웅
    • Tribology and Lubricants
    • /
    • 제24권2호
    • /
    • pp.63-71
    • /
    • 2008
  • Friction and adhesion tests were conducted to investigate tribological characteristics of materials for MEMS/NEMS using atomic force microscope (AFM). AFM Si tips were chemically modified with a self-assembled monolayer (SAM) derived from trichlorosilane like octadecyltrichlorosilane (OTS) and (1H, 1H, 2H, 2H-perfluorooctyl) trichlorosilane (FOTS), and various materials, such as Si, Al, Au, Cu, Ti and PMMA films, were prepared for the tests. SAMs were coated on Si wafer by dipping method prior to AFM tip to determine a proper dipping time. The proper dipping time was determined from the measurements of contact angle, surface energy and thickness of the SAMs. AFM tips were then coated with SAMs by using the same coating condition. Friction and adhesion forces between the AFM Si tip modified with SAM and MEMS/NEMS materials were measured. These forces were compared to those when AFM tip was uncoated. According to the results, after coating OTS and FOTS, the friction and adhesion forces on all materials used in the tests decreased; however, the effect of SAM on the reduction of friction and adhesion forces could be changed according to counterpart materials. OTS was the most effective to reduce the friction and adhesion forces when counterpart material was Cu film. In case of FOTS, friction and adhesion forces decreased the most effectively on Au films.

AFM 기반 Pulse 를 이용한 전기화학적 가공 (Localized Oxidation of (100) Silicon Surface by Pulsed Electrochemical Processes Based on AFM)

  • 이정민;김선호;박정우
    • 대한기계학회논문집A
    • /
    • 제34권11호
    • /
    • pp.1631-1636
    • /
    • 2010
  • 본 연구는 AFM 을 이용하여 nano scale 의 Lithography 를 구현하는 것이다. 외부의 pulse generator 를 통하여 전류를 통전 시키는 방법을 수정함으로써, 일정 습도를 유지한 상태의 AFM 내부에서 Si-wafer 의 표면과 Tip의 사이에 전원을 인가하고 pulse generator 에서 임의로 pulse 폭의 변화를 준다. Si-wafer 표면에서 물 분자가 Tip과 wafer 사이의 직접적인 전류의 이동조절로 인해 전기 화학적 반응을 적절히 제한하여 산화물을 생성시키는 방법이다. 이렇게 생성된 산화물은 불산 처리를 통하여 산화물을 식각시켜 미세 그루브를 구현 할 수 있다. 본 연구를 통한 나노 패턴 생성 기법은 나노 머시닝 기술의 진보에 잠재적 가능성을 제시한다.

AFM을 이용한 스트렙타비딘-바이오틴 단백질 복합체의 흡착 분석 (Absorption analysis of streptavidin-biotin complexes using AFM)

  • 박지은;김동선;최호진;신장규;김판겸;임근배
    • 센서학회지
    • /
    • 제15권4호
    • /
    • pp.237-244
    • /
    • 2006
  • Atomic force microscope (AFM) has become a common tool for the structural and physical studies of biological macromolecules, mainly because it provides the ability to perform experiments with samples in a buffer solution. In this study, structure of proteins and nucleic acids has been studied in their physiological environment that allows native intermolecular complexes to be formed. Cr and Au were deposited on p-Si (100) substrate by thermal evaporation method in sequence with the thickness of $200{\AA}$ and $500{\AA}$, respectively, since Au is adequate for immobilizing biomolecules by forming a self-assembled monolayer (SAM) with semiconductor-based biosensors. The SAM, streptavidin and biotin interacted each other with their specific binding energy and their adsorption was analyzed using the Bio-AFM both in a solution and under air environment. A silicon nitride tip was used as a contact tip of Bio-AFM measurement in a solution and an antimony doped silicon tip as a tapping tip under air environment. Actual morphology could also be obtained by 3-dimensional AFM images. The length and agglomerate size of biomolecules was measured in stages. Furthermore, $R_{a}$ (average of surface roughness) and $R_{ms}$ (mean square of surface roughness) and surface density for the adsorbed surface were also calculated from the AFM image.

AFM 마이크로캔틸레버의 나노 비선형 동역학 (Nanoscale Nonlinear Dynamics on AFM Microcantilevers)

  • 이수일;홍상혁;이장무
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1560-1565
    • /
    • 2003
  • Tapping mode atomic force microscopy (TM-AFM) utilizes the dynamic response of a resonating probe tip as it approaches and retracts from a sample to measure the topography and material properties of a nanostructure. We present recent results based on nonlinear dynamical systems theory, computational continuation techniques and detailed experiments that yield new perspectives and insight into AFM. A dynamic model including van der Waals and Derjaguin-Muller-Toporov (DMT) contact forces demonstrates that periodic solutions can be represented with respect to the approach distance and excitation frequency. Turning points on the surface lead to hysteretic amplitude jumps as the tip nears/retracts from the sample. Experiments are performed using a tapping mode tip on a graphite sample to verify the predictions.

  • PDF