• Title/Summary/Keyword: AFM(Atomic force microscope

Search Result 530, Processing Time 0.028 seconds

마이크로웨이브 화학기상증착법으로 성장된 다이아몬드상 카본박막의 물리적인 특성연구 (Physical Properties of Diamond-like Carbon Thin Films Prepared by a Microwave Plasma-Enhanced Chemical Vapor Deposition)

  • 최원석;홍병유
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.842-845
    • /
    • 2003
  • DLC thin films were prepared by microwave plasma-enhanced chemical vapor deposition method on silicon substrates using methane ($CH_4$) and hydrogen ($H_2$) gas mixture. The negative DC bias ($-450V{\sim}-550V$) was applied to enhance the adhesion between the film and the substrate. The films were characterized by Raman spectrometer. The surface morphology was observed by an atomic force microscope (AFM). And also, the friction coefficients were investigated by AFM in friction force microscope (FFM) mode, which were compared with the pin-on-disc (POD) measurement.

  • PDF

SPM을 이용한 박막의 모폴로지, 표면전위와 광투과이미지 관찰 (Observation of Morphology, Surface potential and Optical Transmission Images in the Thin Film Using SPM)

  • 신훈규;권영수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.327-330
    • /
    • 2000
  • The scanning Maxwell-stress microscopy (SMM) is a dynamic noncontact electric force microscopy that allows simultaneous access to the electrical properties of molecular system such as surface potential, surface charge, dielectric constant and conductivity along with the topography. The Scanning near-field optical / atomic force microscopy (SNOAM) is a new tool for surface imaging which was introduced as one application of the atomic force microscope (AFM). Operated with non-contact forces between the optical fiber and sample as well as equipped with the piezoscanners, the instrument reports on surface topology without damaging or modifying the surface for measuring of optical characteristic in the films. We report our recent results of its application to nanoscopic study of domain structures and electrical functionality in organic thin films by SMM. Furthermore, we have illustrated the SNOAM image in obtaining the merocyanine dye films as well as the optical image.

  • PDF

원자현미경을 이용한 생체물질의 접착력 측정기술 개발 (Novel measuring technique for biological adhesion forces using AFM)

  • 김성주;문원규;전종협
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.641-644
    • /
    • 2005
  • The study on the interaction forces of some biological materials is important to understanding biological phenomena and their application to practical purpose. This paper introduces a measuring technique for biological adhesive forces using the AFM(Atomic Force Microscope). Since no standardized thesis on adhesive forces exist, the adhesive forces is defined as adhesive forces against a hardened surface of biological materials. To grant the results are meaningful, which is based on the understanding the surface characteristics of biological materials using the AFM, a nominal value of average adhesive force per unit area should be measured. Therefore the modified AFM probe with small micro glass bead was proposed so that it can guarantee the required contact area for measuring the average adhesive forces. A pyrex glass substrate with circular patterns, which was fabricated by micromachining technique, is introduced in order to controll the contact area. The two types of mussel adhesive proteins, Celltak and recombinant-MGFP5, were tested by the proposed measuring method. The test results show that the adhesive force of the mussel adhesive proteins can be reliably measured by use of this method.

  • PDF

유기산 완충용액의 포화도가 법랑질 및 상아질의 재광화에 미치는 영향과 수산화인회석의 AFM 관찰 (THE EFFECTS OF THE DEGREE OF SATURATION OF ACIDULATED BUFFER SOLUTIONS IN ENAMEL AND DENTIN REMINERALIZATION AND AFM OBSERVATION OF HYDROXYAPATITE CRYSTALS)

  • 박정원;허복;이찬영
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.459-473
    • /
    • 2000
  • Dental caries is the most common disease in the maxillofacial area. There are many factors contributing to its development, but complete understanding and prevention is not fully known. Since the structure of the coronal and root portion of the tooth is different, the remineralization and demineralization process is also known to be different. In this study, by using a partially saturated buffer solution, we created artificial enamel and dentin caries and evaluated mineral loss. A remineralization solution with four different degrees of saturation (degree of saturation ; group 1, 0.268, group 2, 0.309, group 3, 0.339, group 4, 0.390, PH 4.3, F-2ppm) was used on a demineralized specimen. The mineral precipitating quantity and depth was evaluated by using microradiography. Using an atomic force microscope (AFM), hydroxyapatite crystals of normal, demineralized, and remineralized enamel and dentin were evaluated. The results were as follows: 1. As the degree of saturation of the remineralizing solution increased, the mineral precipitation in the enamel was increased. In group 4, mineral precipitation was limited near the surface. 2. As the degree of saturation of the remineralizing solution increased, the mineral precipitation in the dentin was decreased and it occurred in a deeper portion. In group 4, however, mineral precipitation occurred on the surface and its quantity increased. 3. There was a statistically significant interaction between enamel and dentin mineral content changes on specimens treated with remineralization and demineralization solution (demineralization r=0.44, remineralization r=0.44, p<0.05). 4. Demineralized hydroxyapatite crystals showed central and peripheral dissolving and widening of intercrystal spaces under the AFM. 5. In dentin remineralization small crystal precipitation occurred between the large crystals. We conclude that by adjusting acidulated buffer solution's degree of saturation, we can control enamel and dentin remineralization. In addition, the AFM is highly useful in evaluating changes in remineralized and demineralized hydroxyapatite crystals.

  • PDF

Surface Imaging of Barley Aleurone Cell by Atomic Force Microscopy

  • Kim, Tae-Wan;Huh, Kwang-Woon;Kim, Seung-Hwan;Ku, Hyun-Hwoi;Lee, Byung-Moo;Kim, Jae-Yoon;Seo, Yong-Won
    • 한국작물학회지
    • /
    • 제49권1호
    • /
    • pp.36-40
    • /
    • 2004
  • To observe and analysis ultra-microscopically barley aleurone cell surface, atomic force microscope (AFM) was used. Seed coat of early maturing germplasm, eam9, was dehulled and scanned by non-contact mode. We have obtained the high resolution topographic 3-dimensional image of barley aleurone layer with high resolution. These images showed the membrane proteins in barley aleurone cell. One channel protein and numerous peripheral or integral proteins were detected in a area of 100 $\mu\textrm{m}^2$. Furthermore, we found that their widths were ranged from 50 to 750nm and lengths from 0 to 66 $\mu\textrm{m}$. The thickness of aleurone layer was measured by scanning electron microscope. The thickness at early developmental stage was about 16 and then the aleurone cell enlarged upto 57 $\mu\textrm{m}$${\mu}{\textrm}{m}$ at least until 42 days after anthesis. In this study, we firstly reported on the ultrastructural AFM analysis of living aleurone cell as a biological specimen. It was clearly suggested that AFM will become an powerful tool for probing both the structural properties of biological samples.

PFM을 이용한 AlN 박막의 압전특성 분석에 관한 연구 (A study for piezoelectric properties analysis of the AlN thin film by using PFM)

  • 이종택;김세영;신현창;송준태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.224-225
    • /
    • 2009
  • Aluminium nitride thin film was deposited on Au electrode and Si substrate by radio frequency sputtering system. X-ray diffraction (XRD) was utilized to identify the AlN phase, and Atomic Force Microscope (AFM) was used to obtain the images of surface morphology and roughness value of AlN thin film. The result of XRD and AFM measurement showed that the AlN thin film has strong c-axs orientation and smooth surface. In order to investigate piezoelectric response and polarization properties along to the direction of electric field, PFM (Piezoresponse Force Microscope) system was used, and the images of piezoelectric response due to switching of polarization was observed by PFM.

  • PDF

SPM을 이용한 Si 표면위에 플라즈마 처리된 소수성 박막의 나노 트라이볼로지적 특성 연구 (Nanotribological Characteristics of Plasma Treated Hydrophobic Thin Films on Silicon Surfaces using SPM)

  • 윤의성;양승호;공호성;고석근
    • Tribology and Lubricants
    • /
    • 제19권2호
    • /
    • pp.109-115
    • /
    • 2003
  • Nanotribological characteristics between a Si$_3$N$_4$ AFM tip and hydrophobic thin films were experimentally studied. Tests were performed to measure the nano adhesion and friction in both AFM (atomic force microscope) and LFM (lateral force microscope) modes in various .ranges of normal load. Plasma-modified thin polymeric films were deposited on Si-wafer (100). Results showed that wetting angle of plasma-modified thin polymeric film increased with the treating time, which resulted in the hydrophobic surface and the decrease of adhesion and friction. Nanotribological characteristics of these surfaces were compared with those of other hydrophobic surfaces, such as DLC, OTS and IBAD-Ag coated surfaces. Those of OTS coated surface were superior to those of others, though wetting angle of plasma-modified thin polymeric film is higher.

SPM을 이용한 접촉조건 변화에 따른 미소응착 및 마찰특성에 관한 연구 (A study on the Nano adhesion and Friction at Different Contact Conditions using SPM)

  • 윤의성;박지현;양승호;공호성
    • Tribology and Lubricants
    • /
    • 제17권3호
    • /
    • pp.191-197
    • /
    • 2001
  • Nano adhesion and friction characteristics between SPM(scanning electron microscope) tips and flat plates of different materials were experimentally studied. Tests were performed to measure adhesion and friction in AFM(atomic force microscope) and LFM(lateral force microscope) modes in different conditions of relative humidity. Three different Si$_3$N$_4$ tips (rdaii : 15nm, 22nm and 50 nm) and three different flat plates of Si-wafer(100), W-DLC(tungsten-incorporated diamond-like carbon) and DLC were used. Results generally showed that adhesion and friction increased with the tip radius, and W-DLC and DLC surfaces were superior to Si-wafer. But the adhesion force of Si-wafer showed non linearity with the tip radius while W-DLC and DLC surfaces showed good correlation to the “JKR model”. It was found that high adhesion force between Si-wafer and a large radius of tip was caused by a capillary action due to the condensed water.

OTS SAM의 미소 응착 특성에 관한 실험적 연구 (An Experimental Study on the Nano-adhesion of Octadecyltrichlorosilane SAM on the Si Surface)

  • 윤의성;박지현;양승호;한흥구;공호성
    • Tribology and Lubricants
    • /
    • 제17권4호
    • /
    • pp.276-282
    • /
    • 2001
  • Nano adhesion between SPM (scanning probe microscope) tips and 075 (octadecyltrichlorosilane) SAM (self-assembled monolayer) was experimentally studied. Tests were performed to measure the nano adhesion and friction in both AFM(atomic force microscope) and LFM(lateral force microscope) modes in various conditions of relative humidity. OTS SAM was formed on Si-wafer (100) surfaces, and Si$_3$N$_4$ tips of different radius of curvature were used. When the surface was hydrophobic, the adhesion and friction forces were found lower than those of bare Si-wafer. Results also showed that micro-adhesion force increased as the relative humidity and the tip radius of curvature increased. The main parameter for affecting the micro-adhesion was found absorbed humidity on the contact surface. These results were discussed with the JKR model and a capillary force caused by absorbed water.