• Title/Summary/Keyword: AFD

Search Result 52, Processing Time 0.027 seconds

Characteristics Analysis of RPV and AFD for Anti-Islanding in Active Method (단독운전방지를 위한 능동 방식 중 AFD 및 RPV에 대한 특성해석)

  • Choe, Gyu-Ha;D, Bayasgalan;Lee, Young-Jin;Han, Dong-Ha;Jeong, Byong-Hwan;Kim, Hong-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.160-167
    • /
    • 2009
  • To detect islanding mode when the grid is being tripped is a major safety issue in the Utility Interactive Photo Voltaic (UIPV) system. In this paper, analytical design method is suggested for AFD & RPV method under IEEE 929-2000 recommended islanding test condition. We have discussed that there is a same point. we injected reactive component of the current by AFD & RPV methods, but the current reference generated is other waveform. Possible if amount of reactive components in this methods are same each method, there is happened same rates frequency variation. To verify the validity of the analytical comparison, this paper presents simulation and experimental results from single phase, 3[kW] inverter for the transformerless UIPV system.

Simulation of Non-Detection Zone using AFD Method applied to Utility-Connected Photovoltaic Systems for a Variety of Loads (다양한 부하에 따른 계통연계형 태양광발전 시스템에 적용된 AFD 기법의 단독운전 불검출영역 시뮬레이션)

  • Ko, Moon-Ju;Choy, Ick;Choi, Ju-Yeop;Won, Young-Jin
    • 전자공학회논문지 IE
    • /
    • v.43 no.2
    • /
    • pp.63-69
    • /
    • 2006
  • Islanding phenomenon of utility-connected PV power conditioning systems(PV PCS) can cause a variety of problems and must be prevented. If the real and reactive powers supplied by PV PCS are closely matched to those of load, islanding detection by passive methods becomes difficult. The active frequency drift(AFD) method, called the frequency bias method, enables islanding detection by forcing the frequency of the voltage in the islanding to drift up or down. In this paper, non-detection zone(NDZ) of AFD is analyzed for the islanding detection method of utility-connected PV PCS by simulation tool PSIM.

Auxiliary domain method for solving multi-objective dynamic reliability problems for nonlinear structures

  • Katafygiotis, Lambros;Moan, Torgeir;Cheungt, Sai Hung
    • Structural Engineering and Mechanics
    • /
    • v.25 no.3
    • /
    • pp.347-363
    • /
    • 2007
  • A novel methodology, referred to as Auxiliary Domain Method (ADM), allowing for a very efficient solution of nonlinear reliability problems is presented. The target nonlinear failure domain is first populated by samples generated with the help of a Markov Chain. Based on these samples an auxiliary failure domain (AFD), corresponding to an auxiliary reliability problem, is introduced. The criteria for selecting the AFD are discussed. The emphasis in this paper is on the selection of the auxiliary linear failure domain in the case where the original nonlinear reliability problem involves multiple objectives rather than a single objective. Each reliability objective is assumed to correspond to a particular response quantity not exceeding a corresponding threshold. Once the AFD has been specified the method proceeds with a modified subset simulation procedure where the first step involves the direct simulation of samples in the AFD, rather than standard Monte Carlo simulation as required in standard subset simulation. While the method is applicable to general nonlinear reliability problems herein the focus is on the calculation of the probability of failure of nonlinear dynamical systems subjected to Gaussian random excitations. The method is demonstrated through such a numerical example involving two reliability objectives and a very large number of random variables. It is found that ADM is very efficient and offers drastic improvements over standard subset simulation, especially when one deals with low probability failure events.

Active Frequency Drift Method for Islanding Detection Applied to Micro-inverter with Uncontrollable Reactive Power

  • Kwak, Raeho;Lee, June-Hee;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1918-1927
    • /
    • 2016
  • This paper proposes active frequency drift (AFD) as an anti-islanding method applied to micro-inverters with uncontrollable reactive power. When using ordinary inverter topologies, such as full bridge inverters in photovoltaic systems, the islanding phenomenon can be detected with reactive power-based methods, such as reactive power variation. However, when the inverter topology cannot control the reactive power, conventional anti-islanding methods with reactive power cannot be utilized. In this work, the topology used in this paper cannot control the reactive power. Thus, an anti-islanding method that can be used in topologies that cannot control the reactive power is proposed. The conventional anti-islanding method of the topology that cannot control reactive power is introduced and analyzed. Unlike the conventional AFD method, the proposed method extends a zero current interval every predetermined cycle. The proposed method offers certain advantages over conventional AFD methods, such as total harmonic distortion. The proposed method is validated through simulation and experiment.

A rare case report of ameloblastic fibrodentinoma with imaging features in a pediatric patient

  • Youjin Jung;Kyu-Young Oh;Sang-Sun Han;Chena Lee
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.207-210
    • /
    • 2024
  • Ameloblastic fibrodentinoma (AFD) is a rare benign odontogenic tumor that resembles an ameloblastic fibroma with dysplastic dentin. This report presents a rare case of mandibular AFD with imaging features in a young patient. Panoramic radiography and computed tomography revealed a well-defined lesion with internal septa and calcified foci, causing inferior displacement of the adjacent molars as well as buccolingual cortical thinning and expansion of the posterior mandible. The lesion was surgically removed via mass excision, and the involved tooth was extracted under general anesthesia. During the 5-year follow-up period, no evidence of recurrence was observed. Radiologic features of AFD typically reveal a moderately to well-defined mixed lesion with varying degrees of radiopacity, reflecting the extent of dentin formation. Radiologists should consider AFD in the differential diagnosis when encountering a multilocular lesion with little dense radiopacity, particularly if it is associated with delayed eruption, impaction, or absence of involved teeth, on radiographic images of young patients.

Link Adaptation for Full Duplex Systems

  • Kim, Sangchoon
    • International journal of advanced smart convergence
    • /
    • v.7 no.4
    • /
    • pp.92-100
    • /
    • 2018
  • This paper presents a link adaptation scheme for adaptive full duplex (AFD) systems. The signal modulation levels and communication link patterns are adaptively selected according to the changing channel conditions. The link pattern selection process consists of two successive steps such as a transmit-receive antenna pair selection based on maximum sum rate or minimum maximum symbol error rate, and an adaptive modulation based on maximum minimum norm. In AFD systems, the antennas of both nodes are jointly determined with modulation levels depending on the channel conditions. An adaptive algorithm with relatively low complexity is also proposed to select the link parameters. Simulation results show that the proposed AFD system offers significant bit error rate (BER) performance improvement compared with conventional full duplex systems with perfect or imperfect self-interference cancellation under the same fixed sum rate.

Conditions for the disinfectant efficacy test under subzero temperatures

  • Chae, Won-Seok;Jeong, Wooseog;Lee, Hu-Jang
    • Korean Journal of Veterinary Research
    • /
    • v.59 no.1
    • /
    • pp.43-45
    • /
    • 2019
  • To establish appropriate conditions for a disinfectant efficacy test at subzero temperatures, this study examined mixtures of frozen foot-and-mouth disease virus or avian influenza virus solutions and disinfectant diluents at $-5^{\circ}C$ and monitored temperature and freezing status of an anti-freezing diluent (AFD, 15% ethanol + 30% propylene glycol + 55% distilled water) over time at various subzero temperatures. Viral solutions and disinfectant diluents froze before the mixtures reached $-5^{\circ}C$, whereas the AFD was not frozen at $-30^{\circ}C$. The times taken for the AFD to reach -10, -20, -30, and $-40^{\circ}C$ from room temperature were 36, 39, 45, and 48 min, respectively.

The improved AFD method for islanding detection (단독운전 검출을 위한 개선된 AFD 기법)

  • Go, Geun-Taek
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.59-60
    • /
    • 2011
  • 계통 연계형 인버터는 규정 시간 내에 반드시 단독운전 상황을 검출해야 한다. 계통 사로고 인해 계통전력이 차단되면 인버터가 이 상황을 제대로 감지하지 못 해 계통에 연결된 인버터가 계속 동작을 하게 된다면 위험한 상황을 초래하게 될 수도 있다. 이로 인해 계통연계형 인버터는 규정 시간 내에 계통이 이상을 감지하고 인버터의 동작을 멈추어야 한다. 이런 단독운전 상황을 방지하기 위해 본 논문에서 제시하는 알고리즘은 구현 자체가 간단하지만 기존의 알고리즘으로는 검출할 수 없었던 영역을 검출할 수 있고, 검출 속도 또한 개선을 했다. 실험 결과를 통해 알고리즘의 타당성을 검증하였다.

  • PDF

Development of Novel Algorithm for Anti-Islanding of Grid-Connected PV Inverter (계통연계형 태양광 인버터의 단독운전 방지를 위한 새로운 알고리즘 개발)

  • Choi, Jung-Sik;Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.76-86
    • /
    • 2011
  • This paper proposes novel algorithm for anti-islanding of grid-connected photovoltaic(PV) inverter. The islanding of PV systems can cause a variety of problems such as deterioration in power quality and electric shock. To prevent islanding, many anti-islanding methods are researched. Typical methods of anti-islanding are active frequency drift(AFD) and active frequency drift positive feedback(AFDPF). However, the AFD has problem that widely exists non diction zone(NDZ). The AFDPF is a method that improves the AFD method and is detected islanding by changing the chopping fraction(cf). However, The AFDPF does not detect when cf is very small and does not satisfy the IEEE Std. 929-2000 when cf is very big. Therefore, this paper proposes novel anti-islanding method that is simple to implement using virtual resister. The anti-islanding method proposed in this paper is compared with conventional method. The validity of this paper is proved using this result.

CANFLEX-RU(0.9%) 핵연료다발의 예비 열수력 특성 해석

  • 전지수;박주환;민병주;정창준;석호천
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.526-531
    • /
    • 1998
  • 본 논문은 농축도 0.9%의 순환우라늄 핵연료(CANFLEX-RU)에 대한 축방향 출력분포(AFD) 및 반경방향 출력분포(RFD) 특성을 조사하고 CANFLEX-RU 다발이 장전된 CANDU줄 채널의 예비 열수력 해석을 수행하였다. CANFLEX-RU 다발의 4 bundle shift 핵연료 교체 방법에 따라 AFD 분포 특성은 정점(Peak) 열속이 채널 상류쪽으로 이동하였고 채널 중심 부근에서 평탄하거나 다소 오목한 형상을 보여주었다. RFD 분포를 표현하는 적절한 변수로서 국부 다발열유속비를 정의하고, 이 비와 국부 표면열유속비의 상호 관계식을 도출하였다. 연소도에 따른 최외환봉의 국부 다발열유속비 변화를 조사한 결과로서, CANFLEX-RU 다발의 최대 국부 다발열유속비는 초기 연소도에서 발생되었고 이 값 CANFLEX-NU 다발 보다는 크고 37-핵연료봉다발 보다는 작았다. CCP 계산시에 RFD 분포 효과를 고려하는 방안으로서 최외환봉 열유속을 다발의 국부 열유속으로 가정하였다 이는 임계열유속이 -10.2% 감소한 조건을 사용하여 CCP를 계산하는 결과가 되었다. 다발-블균형 계수를 이용한 CCP 민감도 결과와 본 계산에서 얻은 CCP 결과에 의하면, CANFLEX-RU의 CCP 는 CANFLEX-NU에 비교해서 土1.0% 이내로 근사한 분포가 예상되었으며 이는 AFD 분포 효과가 RFD 분포에 의한 CCP 감소를 보상하기 때문이다. 결론적으로, CANFLEX-RU는 열수력적 설계 관점에서 CANFLEX-NU에 비교해서 열적 성능이 저하되지 않았고 따라서 기존 37-핵연료봉다발에 대한 CANFLEX-NU의 열여유도 증가와 같은 장점을 유지할 것으로 예상되었다.

  • PDF