• Title/Summary/Keyword: AEC

Search Result 256, Processing Time 0.033 seconds

Work-life Conflicts in the AEC Industry - A Comparative Analysis

  • Hu, Wei;Panthi, Kamalesh
    • Journal of Construction Engineering and Project Management
    • /
    • v.8 no.2
    • /
    • pp.1-16
    • /
    • 2018
  • The Architectural, Engineering and Construction (AEC) industry has a culture of long working hours that sometimes extend to weekends. As a result, construction employees find it challenging to achieve a balance between their work and personal lives. It is believed that there is rarely a clear separation between employees' work and personal life in the AEC industry. This paper suggests that in order to attract and retain a talented workforce, AEC organizations have to cater for the diverse needs of employees with regard to work-life balance. This paper presents the results of a survey of both professional and managerial employees' perspective on work-life conflict issues in private and public AEC organizations. Perspectives were found to differ, although not significantly, by employees' experience, leadership experience, age and gender. Furthermore, most survey respondents noted that their employers did not have a policy or program in place supporting work-life balance initiatives. Finally, although the AEC industry is making strides to improve work-life balance, the effort is lagging behind other industry sectors in providing policies and programs to promote work-life balance through flexible work hours and various other means.

NLMS Adaptive Filter Based Acoustic Echo Canceller (NLMS 적응 필터 기반의 음향 반향 제거기)

  • Hwang, Sung-Sue;Yun, Sang-Suk;Kim, Suk-Chan;Lee, Chae-Dong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.4C
    • /
    • pp.343-349
    • /
    • 2010
  • In this paper, we study real time AEC (acoustic echo canceller) based on NLMS adaptive filter. Proposed method improves conversation quality by enhancing the performance of AEC during double talk section and reduces the power consumption by controling the adaption operation of NLMS adaptive filter. Proposed method examines the convergence of the NLMS adaptive filter, stores the estimated echo path and chooses operation of NLMS adaptive filter. Furthermore if double talk is detected, the proposed AEC utilizes the stored echo path optionally considering missed double talk time. When the proposed AEC is used, the performance of the AEC is enhanced although the simple double talk detector is used and the power consumption of the AEC is reduced.

Opportunities and Challenges for Vietnam in AEC (AEC 출범 이후 베트남 경제의 기회와 도전)

  • Beak, Yong Hun
    • International Area Studies Review
    • /
    • v.21 no.4
    • /
    • pp.101-124
    • /
    • 2017
  • This study is to examine the current situation of the AEC (ASEAN Economic Community) and analyze macroeconomic situation of Vietnam since the launch of AEC. According to recent trade indicators, Vietnam is expected to be more productive in the manufacturing and processing sectors because it is at the heart of the global value chains (GVCs) in electronics, telephones, and textiles and shoes industry. Vietnam has signed or is negotiating free trade agreements with various countries around the world including Korea, Israel, EU and RCEP and so on. Therefore, it is expected that Vietnam's trade dependency and FDI inflows to Vietnam increase more and more. However, the fact that the proportion of exports by foreign-invested companies accounts for about 70% of the total exports implies the uncertainty of Vietnam's economy in the future. Attracting FDI investment can further reduce the competitiveness of domestic companies in Vietnam. Therefore, in order for Vietnam to maintain sustainable development in the future, it is necessary to reform the momentum of foreign-invested enterprises to the development of Vietnamese companies.

Selection and Characterization of S-Aminoethyl-L-Cysteine Resistant Plants from Gamma-ray Irradiated Embryogenic Callus in Sweet potato

  • Lee In-Sok;Kim Dong-Sub;Hong Chang-Pyo;Kang Si-Yong;Song Hi-Sup;Lee Sang-Jae;Lim Yong-Pyo;Lee Young-Il
    • Journal of Plant Biotechnology
    • /
    • v.5 no.4
    • /
    • pp.233-238
    • /
    • 2003
  • Sweet potato cells derived from Yulmi were isolated from embryogenic callus and irradiated with 50 Gy dose. Resistant cells were selected on a MS medium containing 1.0 mM S-aminoethyl-L-cysteine (AEC). This level of AEC approximately inhibits non-selected wild type cells. The callus resistant to this analog of lysine was subcultured for 30 days in absence of AEC to proliferate. The three resistant calli (AR-1, AR-2 and AR-3) with better growth were divvied into 0.5~1mm diameter and placed on MS medium with 0, 0.4, 0.6, 0.8 and 1.0 mM AEC. There are considerable growth difference between control callus and AEC resistant callus on the AEC-medium. The selected calli were placed on the hormone-free medium for regeneration. Three plantlets, five plantlets and six plantlets were recovered from AR-1, AR-2 and AR-3 calli, respectively. Each two regenerants in AR-1, AR-2 and AR3 were randomly selected for RAPD and SDS PAGE analysis. RAPD polymorph isms between Yulmi and AEC resistant plant from irradiated calli were detected in several Wako primers. Also, it was identified that two AEC resistant plants had higher protein than the original variety Yulmi.

The Influence of the Change of Patient Radiation Exposure Dose Distribution on the Grid Condition and Detector Acquisition Dose on the Exposure Distance in the Use of Amorphous Silicon Thin Film Transistor Detector with AEC (자동노출제어장치를 이용한 비정질 실리콘 평판형 검출기에서 격자의 조건에 따른 환자선량 변화와 촬영 거리의 변화가 검출기 획득선량에 미치는 영향)

  • Yoon, Seok-Hwan;Choi, Jun-Gu;Han, Dong-Kyoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.23-30
    • /
    • 2007
  • This study attempts to propose an appropriate method of using digital medical imaging equipments, by studying the effects of automatic exposure control(AEC), grid ratio and the change of radiography distance on the patient dose and detertor acquisition dose during the procedure of acquiring image through a digital medical imaging detector. The change of dose following the change of grid ratio's exposure and radiography distance was measured, by using an abdominal phantom organized with tissue equivalent materials in an amorphous silicon thin film transistor detecter installed with AWC. The case to use grid ratio 12 : 1, focal distance 180cm to radiography distance 110cm in AEC, the patient dose increased rather when we used grid ration 10 : 1, focal distance 110cm. When AEC was not used,the dose necessary for image acquisition decreased as the grid ratio became higher and the distance became further. but detector acquisition dose was not reduced when in applied AEC. When purchasing digiral medical imaging equipments, optional items such as AEC and grid shall be accurately selected to satisfy the use of the equipments. Radiography error made by radiation technologist and unnenessary patient dose can be reduced by selecting equipments with a radiography distance marker equipment when it did not apply AEC. These equipments can also be helpful in maintaining high imaging quality, one of the merits of digital detectors.

  • PDF

Selection of 5-Methyltryptophan and S-(2-Aminoethyl)-L-Cysteine Resistant Microspore-Derived Rice Cell Lines Irradiated with Gamma Rays

  • Kim, Dong-Sub;Lee, In-Sok;Jang, Cheol-Seong;Hyun, Do-Yoon;Lee, Sang-Jae;Seo, Yong-Weon;Lee, Young-Il
    • Journal of Plant Biotechnology
    • /
    • v.5 no.1
    • /
    • pp.33-41
    • /
    • 2003
  • Microspore-derived cell lines resistant to 5-methyltryptophan (5MT, a tryptophan analog) or S-(2-aminoethyl)-L-cysteine (AEC, a Iysine analog) were selected in rice by in vitro mutagenesis. For selection of 5MT or AEC resistant cell lines, suspension-cultured cells were irradiated with gamma rays. Thirteen 5MT resistant cell lines were selected and they were able to grow stably at 2 times higher 5MT concentration. A feedback insensitive form of anthranilate synthesis, the pathway specific control enzyme for tryptophan synthesis, was detected from the 5MT resistant lines. Contents of the free amino acids in five resistant lines (MR12-1 to MR12-5) showed a 7.4 to 46.6 times greater level than that in the control culture. Tryptophan, phenylalanine, and tyrosine levels in the shikimate pathway were 28.1 and 22.5 times higher in MR12-3 and MR12 4, respectively, than that measured in the control cells. Four AEC resistant cell lines were isolated from cultures grown on medium containing 1 mM AEC, They were able to grow stably with 2 mM AEC, while sensitive calli were inhibited by 0.5 mM AEC. Aspartate kinase activities of the resistant lines were insensitive to the natural inhibitor, Iysine, and accumulated 2.2 to 12.9-fold higher levels of free Iysine than that of the control cells. Especially, the levels of aspartate, asparagine, and methionine in the aspartate pathway showed higher accumulation in the AEC resistant lines than that in the control cells.

Comparison of Exposure Dose by Using AEC Mode of Abdomen AP Study in Radiography (복부 전후 방향 검사의 자동노출제어 사용 시 선량 비교 연구)

  • Kim, Ki-Won;Kwon, Yong-Rak;Seo, Seong-Won;Kwon, Kyung-Tae;Oh, Joo-Young;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.205-211
    • /
    • 2015
  • We evaluated the effectiveness of TL (Time Limit) method by comparing with NTL (Non-time limit) method when it is used for examinations for abdomen Anterior Posterior (AP) in this paper. The evaluation was conducted based on the comparison of dose, and of signal to noise ratio (SNR) and contrast to ratio (CNR) on both methods. The experiments were conducted with XGEO GC 80 (Samsung, Korea), Unfors ThinX RAD (Unfors, Sweden) and Rando Phantom (Alderson research laboratories, USA) and shielding material with the size of $5.5{\times}9{\times}0.1cm^3$. It was set to activate only two upper ionization chambers in automatic exposure control(AEC) mode and the tube-voltage was set to 80kVp. When the exposure time was limited, it is limited to 51 msec. The images both by NTL AEC method and TL AEC method were acquired when with and without attachment of shielding material on the upper ionization chambers. The images were evaluated by SNR and CNR which are the image evaluation methods using 'Image J'. The NTL AEC method showed increases in dose as much as 130.7% at maximum and 80% at minimum than other methods. The TL AEC method showed decreases in mAs and exposure dose than the NTL AEC method as much as 43.8% and 44.4% respectively. There were no significant differences in SNR or CNR for the experiments (($p{\geq}0.05$). Therefore, it is suggested that the TLAEC mode is more effective when examining patients who have high BMI index or a patient with a metallic substance in the body after surgery.

Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography (전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가)

  • Kim, Jeong Jin;Jang, Seong Won;Park, Jang Heum;Lee, Kwan Seob;Ha, Dong Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF

Comparison of the Breast Dose based on the Existence of the Bismuth Breast Protection Shield for Automatic Exposure Control and Manual Exposure Control with the Coronary Artery CT Angiography

  • Kim, Sang-Tae;Kang, Sang-Koo;Kim, Chong-Yeal
    • International Journal of Contents
    • /
    • v.7 no.4
    • /
    • pp.103-107
    • /
    • 2011
  • The effective dose and the organ absorbed dose, which are given to a breast in the cases of using and not using the bismuth breast protection shield for the protection of a breast with the coronary artery CT angiography, have been measured and compared for the manual exposure control (MEC)and the automatic exposure control (AEC). In the cases of using and not using the bismuth breast protection shield, it has been found that the measured dose shows the reduction of about 23 to 26% for the MEC and about 22 to 25% for the AEC when the shield is used compared to the case of not using it. By comparing the shield and non-shield cases for the AEC and the MEC, it can be said that the value measured by carrying out the scanning process with the AEC mode has decreased by about 24 to 30% compared to the case of applying the MEC mode. Such a result shows that it is recommended to use the AEC mode for the reduction of the patient's exposure dose during the CT examination.

Development of Lifecycle Support Modules for the ISO 10303-AP241; Generic model for Lifecycle support of AEC facilities (AEC 시설물 공통모델(ISO 10303-AP241)의 생애주기 지원 모듈 개발)

  • An, Kyung-Ik;Kim, In-Han
    • Korean Journal of Computational Design and Engineering
    • /
    • v.13 no.5
    • /
    • pp.342-351
    • /
    • 2008
  • ISO 10303-AP241 is an Application Protocol of ISO 10303, which specifies the representation of AEC facility's life cycle information. The Working Draft of AP241 was submitted to the TC184/SC4 of ISO in July, 2007 by Korean team of ISO TC184/SC4/WG3. This paper introduces the currently developed draft Ap241 core model, and describes the life cycle support modules which are required to represent the life cycle information of AEC facilities. The draft core model is developed as a generic data model which is useful as a basis for implementation in a data warehouse. This core model could be used in combination with reference data such as PLCS RDL, Gellish table and RDL of ISO 15926. These concepts already exists in ISO 10303-AP221, AP239 and ISO 15926. In order to support maintenance and feedback of operational information concerning the AEC facilities, the AP241 team re-used many modules from AP239, and developed various STEP Application Modules which are adapted from the ISO 15926.