• Title/Summary/Keyword: AE count

Search Result 135, Processing Time 0.027 seconds

The Damage Evaluation and Acoustic Emission Characteristics of the Unidirectional Ply CFRP Composite Materials in a Drilling Procedure (드릴작업중 발생되는 일방향 적층 CFRP 복합재료의 손상평가 및 AE특성)

  • Youn, Y.S.;Kwon, O.H.
    • Journal of Power System Engineering
    • /
    • v.3 no.2
    • /
    • pp.42-50
    • /
    • 1999
  • In recent years, composite materials like CFRP are increasingly used in various fields of engineering because of their unique properties which offer a high strength/density and high modulus/density. When CFRP structures are manufactured in drilling processes which are frequently practiced in an Industry, they bring on the delaminations sometimes. So, acoustic emission(AE) techniques were used for a condition monitoring of the drilling process in CFRP. In this study, the AE from CFRP estimated the delamination which reduces the strength and load carrying capacity under the drilling process and the initial delamination were well caught and measured by a video camera. From the results, it was found the relationships between failure mechanism of CFRP delamination and AE characteristics as like amplitude and count.

  • PDF

Tool fracture detection in end milling using cutting force and acoustic emission propagated through cutting fluid (엔드밀 가공시 절삭력과 절삭유를 통해 전파된 음향방출을 이용한 공구파손 검출)

  • Maeng, M.J.;Cho, S.S.;Chung, J.K.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.11
    • /
    • pp.163-170
    • /
    • 1997
  • End milling experiments are conducted to investigate characteristics of acoustic emission (AE) and cutting force singals due to tool fracture. The AE signals are obtained with a sensor attached to cutting fluid discharge nozzle. Tool states are identified with scanning electron microscopy and optical microscopy. It is demonstrated that the AE signals provide reliable informations about the cutting processes and tool states. Morever, tool fracture can be detected successfully using both the AE count rate and the standard deviation of principal cutting force.

  • PDF

Damage Analysis of Singly Oriented Ply Fiber Metal Laminate under Concentrated Loading Conditions by Using Acoustic Emission (음향 방출법을 이용한 집중하중을 받는 일방향 섬유 금속 적층판의 손상 해석)

  • 남현욱;김용환;한경섭
    • Composites Research
    • /
    • v.14 no.5
    • /
    • pp.46-53
    • /
    • 2001
  • In this research, damage behavior of singly oriented ply (SOP) fiber metal laminate (FML) subjected to concentrated load was studied. The static indentation tests were conducted to study fiber orientation effect on damage behavior of FML. During the static indentation tests, acoustic emission technique (AE) was adopted to study damage characteristics of FML. AE signals were obtained by using AE sensor with 150kHz resonance frequency and the signals were compared with indentation curves of FML. The damage process of SOP FML was divided by three parts, i.e., crack initiation, crack propagation, and penetration. The AE characteristics during crack initiation show that the micro crack is initiated at lower ply of the plate, then propagate along the thickness of the plate with creating tiber debonding. The crack grow along the fiber direction with occurring 60∼80dB AE signal. During the penetration, the fiber breakage was observed. As fiber orientation increases, talc fiber breakage occurs more frequently. The AE signal behaviors support these results. Cumulative AE counts could well predict crack initiation and crack propagation and AE amplitude were useful for the prediction of damage failure mode.

  • PDF

Comparative Study on Detecting Methods for Total Coliform in Sewage Effluent (하수 방류수에서 대장균군의 검출방법의 비교)

  • Lee, Mi-Ae;Sung, Il-Wha
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.5
    • /
    • pp.422-427
    • /
    • 2007
  • The purposes of this study were to investigate the concentration of total coliforms in sewage effluents during the period from August 2004 to October 2005. The removal efficiency range of multi-tube method and plate count method were $31.3{\sim}99.5%$ and $66.8{\sim}99.2%$, respectively. Though a correlation between the multi-tube method and the plate count method in the same sample is low, not only is an experimental procedure very simple, but the time required also is short. The seasonal correlation between methods showed more sensitive spring and summer than autumn and winter. So the study indicated plate count method can be used in rapid and reliance identification of total coliform more than the multi-tube method.

Nasal eosinophilia and eosinophil peroxidase in children and adolescents with rhinitis

  • Choi, Yeonu;Jeon, Haeun;Yang, Eun Ae;Yoon, Jong-Seo;Kim, Hyun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.62 no.9
    • /
    • pp.353-359
    • /
    • 2019
  • Background: Researchers have shown that eosinophil peroxidase (EPO) is a relatively accurate marker of eosinophilia and eosinophil activity. However, its use as a marker of eosinophilic inflammation in nasal secretions is limited because the diagnostic cutoff values of EPO for use as a one-time test for allergic diseases such as allergic rhinitis have not been established. Purpose: To identify the correlation between nasal eosinophil count and EPO in children and adolescents with rhinitis. Methods: We recruited patients <18 years of age with rhinitis for more than 2 weeks or more than 2 episodes a year whose nasal eosinophil and EPO were measured at a single allergy clinic. The eosinophil percentage was calculated by dividing the eosinophil count by the number of total cells under light microscopy at ${\times}1,000$ magnification. EPO and protein were measured from nasal secretions. We retrospectively analyzed the correlation between nasal eosinophils and protein-corrected EPO (EPO/protein) value. Results: Of the 67 patients enrolled, 41 were male (61.2%); the mean age was $8.2{\pm}4.0years$. The median nasal eosinophil count was 1 and percentage was 1%. The median protein-corrected EPO value was $12.5ng/{\mu}g$ (range, $0-31ng/{\mu}g$). There was a statistically significant correlation between eosinophil count and percentage (P<0.001). However, the eosinophil percentage and EPO did not correlate. The eosinophil count and EPO had a statistically significant correlation (P=0.01). The EPO cutoff value examined for nasal eosinophil counts of 2, 5, 10, and 20 was $17.57ng/{\mu}g$ regardless of the reference count. The largest area under the curve value was obtained when the receiver operating characteristic curve was drawn using the eosinophil count of 2. Conclusion: Nasal eosinophil count was significantly associated with protein-corrected EPO.

Deformation Behaviors and Acoustic Emissions of Rock Joints in Direct Shear (직접전단시험을 통한 암석 절리의 변형거동 및 미소파괴음 발생에 관한 연구)

  • 김태혁;이상돈;이정인
    • Tunnel and Underground Space
    • /
    • v.4 no.3
    • /
    • pp.274-286
    • /
    • 1994
  • Direct shear tests were on ducted in a laboratory setting in order to investigate the shear strength and deformation behavior of rock joints. Also, the characteristics of acoustic emissions (AE) during shearing of rock joints were studied. The artificial rock joints were created by splitting the intact blocks of Hwangdeung granites and Iksan marbles. Joint roughness profiles were measured by a profile gage and then digitized by Image analyzer. Roughness profile indices(Rp) of the joints were calculated with these digitized data. Peak shear strength, residual shear strength, shear stiffness and maximum acoustic emission(AE) rate were investigated with joint roughness. The peak shear strenght, the residual shear strength and the shear stiffness were increased as roughness popfile index or normal stress increased in the shear tests of granites. In the tests of marble samples, the shear deformation characteristics were not directly affected by joint roughness. As the result of two directional shear tests, the shear characteristics were varied with shear direction. AE count rates were measured during the shear deformation and the AE signals in several stages of the deformation were analyzed in a frequency domain. The AE rate peaks coincided with the stress drops during the shear deformation of joint. The dominant frequencies of the AE signals were in the vicinity of 100 kHz fo rgranite sample and 900 kHz for marble samples. The distribution of amplitude was dispersed with increasing normal stress.

  • PDF

A Study on Source Mechanisms of Micro-Cracks Induced by Rock Fracture (암석파괴시 발생되는 미세균열의 발생원에 대한 연구)

  • 김교원
    • The Journal of Engineering Geology
    • /
    • v.6 no.2
    • /
    • pp.59-64
    • /
    • 1996
  • Acoustic Emission(AE) signals are emitted by a sudden release of strain energy associated with material damage. A multi-channels of LeCroy system and piezoelectric pressure transducers are employed for AE measurement to investigate the roles of AE in the propagation of macro cracks as well as the characteris-tics of AE wave in occurrence, amplitude and dominant frequency with changes in macro loading modes. Deduced crack opening volume of micro cracks varied widely and implies that AE events could be caused by crystal dislocations on a small scale and grain boundary movements on a large scale. Amplitude of first arrival AE wave emitted during mode I test was approximately 3 times higher than those from mixed mode test, while the number of AE count in mode I test was only 25% of mixed mode. It may imply that the total energy required for generation of a given fracture surface is similar regardless in change of macroloading modes.

  • PDF

Study of Fracture Toughness Measurement and Fracture Stability Evaluation by Acoustic Emission Method (음향 방출법에 의한 파괴 인성치 측정 및 파괴 안정성 평가를 위한 연구)

  • 이강용;백충헌
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.1
    • /
    • pp.96-104
    • /
    • 1989
  • The behaviors of acoustic emission emitted in the tests of the fracture toughness and fracture stability are observed by using the specimens of aluminum 2024-T351 and 7039-T6 alloys. The empirical eqution of J-R curve is derived. It is demonstrated from the comparison of the fracture toughness obtained from J-R curve with that from ASTM standard E813-81 that the latter is larger than the former. The discontinuous point in the log-log graph of J-integral vs. total acoustic emission count is observed in between the two offset lines referred from ASTM standard E813-81, but it's physical meaning is uncretain. An empirical material tearing modulus is derived in terms of the total acoustic emission count and proved to be valid in fracture instability test.

A Study on Acoustic Emission Characteristics of MCrAlY Coated Material by Vacuum Plasma Spray Process (진공 플라즈마 용사공정에 의한 MCrAlY코팅재의 음향방출 신호 특성 연구)

  • 박진효;이구현;예경환;김정석;강명창
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.921-924
    • /
    • 2004
  • This paper is to investigate a crack for plasma sprayed MCrAlY coated material by acoustic emission method in 4-point bending test. The CoNiCrAlY is coated on Inconel-718 by vacuum plasma spray process. Micro-hardness measurement was conducted by means of Micro Vickers-hardness indentor. The porosity of coating layer was measured using a SEM and Image Analyzer. AE monitoring system is composed of PICO type sensor, a wide band preamplifier(40dB), a PC and AE DSP(16/32 PAC) board. The AE count, Hit and energy of coating specimens is measured according to coating thickness.

  • PDF

The Monitoring of Abnormal Rotary Compressor using Acoustic Emission (AE를 이용한 회전형 압축기의 이상상태 감시)

  • 정지홍;이기용;강명창;김정석;이감규;안봉열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.328-332
    • /
    • 1996
  • The compressor is one of important elements in refrigerator cycle and play an important role of refrigeration efficiency and quality. Therefore it is very important to monitor state of normal and abnormal compressor. In this research, technic of AE is used for monitoring abnormal rotary compressor and an AE parameter which is a most proper parameter to monitor the abnormal state of compressor is determined by signal processing, Finally, the monitoring result of rotary compressor is agreement with the result of life test.

  • PDF