• Title/Summary/Keyword: AE Parameters

Search Result 418, Processing Time 0.035 seconds

Correlation between Caloric Intake and Lung Function Parameters in Patients with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환 환자에서 열량섭취와 폐기능지표와의 상관관계)

  • Yoon, Ho Il;Park, Young Mi;Choue, Ryowon;Kang, Yeong Ae;Kwon, Sung Youn;Lee, Jae Ho;Lee, Choon-Taek
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.5
    • /
    • pp.385-389
    • /
    • 2008
  • Background: There are reports that food deprivation causes emphysematous changes in the lungs of rats and humans. However, the meaning of this phenomenon in patients with chronic obstructive pulmonary disease has not been evaluated. The aim of this study was to determine the correlations between the caloric intake and parameters of the lung function in patients with chronic obstructive pulmonary disease. Methods: Patients with chronic obstructive pulmonary disease who had visited the respiratory clinic from March, 2006 for one year were enrolled in this study. The patients underwent pulmonary function tests, and a dietitian evaluated their nutritional intake using a food record method. Results: There was no correlation between the total caloric intake and forced vital capacity (FVC, %predicted) or forced expiratory volume in one second ($FEV_1$, %predicted). The total caloric intake showed a positive correlation with the diffusing capacity of carbon monoxide (DLCO %predicted, DLCO/VA %predicted), and a negative correlation with the total lung capacity (TLC, %predicted). Of the calories taken, only calories from protein intake correlated with the diffusing capacity of carbon monoxide (DLCO %predicted, DLCO/VA %predicted). Conclusion: The total caloric intake of patients with chronic obstructive pulmonary disease showed a positive correlation with the diffusing capacity of the lung, and a negative correlation with the total lung capacity. Further study on the linkage between the caloric intake and severity of emphysema is needed.

Effect of Pre-harvest Irradiation of UV-A and UV-B LED in Ginsenosides Content of Ginseng Sprouts (새싹 인삼의 수확 전 UV-A 및 -B LED의 조사에 의한 진세노사이드의 영향)

  • Jang, Seong-Nam;Lee, Ga-Oun;Sim, Han-Sol;Bae, Jin-Su;Lee, Ae-Ryeon;Cho, Du-Yong;Cho, Kye-Man;Son, Ki-Ho
    • Journal of Bio-Environment Control
    • /
    • v.31 no.1
    • /
    • pp.28-34
    • /
    • 2022
  • This study was conducted to determine the changes in ginsenosides content according to additional UV-A, and UV-B LED irradiation before harvesting the ginseng sprouts. One-year-old ginseng seedlings (n=100) were transplanted in a tray containing a ginseng medium. The ginseng sprouts were grown for 37 days at a temperature of 20℃ (24h), a humidity of 70%, and an average light intensity of 80 µmol·m-2·s-1 (photoperiod; 24h) in a container-type plant factory. Ginseng sprouts were then transferred to a custom chamber equipped with UV-A (370 nm; 12.90 W·m-2) and UV-B (300 nm; 0.31 W·m-2) LEDs and treated for 3 days. Growth parameters and ginsenoside contents in shoot and root were conducted by harvesting on days 0 (control), 1, 2, and 3 of UV treatments, respectively. The growth parameters showed non-significant differences between the control and the UV treatments (wavelengths or the number of days). Ginsenoside contents of the shoot was highly improved by 186% in UV-A treatment compared to the control in 3 days of the treatment time. The ginsenoside contents of the roots was more improved in UV-A 1-day treatment and UV-B 3-day treatment, compared to the control by 171% and 160%, respectively. As a result of this experiment, it is thought that UV LED irradiation before harvesting can produce sprout ginseng with high ginsenoside contents in a plant factory.

SINUS FLOOR GRAFTING USING CALCIUM PHOSPHATE NANO-CRYSTAL COATED XENOGENIC BONE AND AUTOLOGOUS BONE (칼슘포스페이트 나노-크리스탈이 코팅된 골이식재와 자가골을 병행 이용한 상악동 거상술)

  • Pang, Kang-Mi;Li, Bo-Han;Alrashidan, Mohamed;Yoo, Sang-Bae;Sung, Mi-Ae;Kim, Soung-Min;Jahng, Jeong-Won;Kim, Myung-Jin;Ko, Jea-Seung;Lee, Jong-Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.3
    • /
    • pp.243-248
    • /
    • 2009
  • Purpose: Rehabilitation of the edentulous posterior maxilla with dental implants often poses difficulty because of insufficient bone volume caused by pneumatization of the maxillary sinus and by crestal bone resorption. Sinus grafting technique was developed to increase the vertical height to overcome this problem. The present study was designed to evaluate the sinus floor augmentation with anorganic bovine bone (Bio-$cera^{TM}$) using histomorphometric and clinical measures. Patients and methods: Thirteen patients were involved in this study and underwent total 14 sinus lift procedures. Residual bone height was ${\geq}2mm$ and ${\leq}6mm$. Lateral window approach was used, with grafting using Bio-$cera^{TM}$ only(n=1) or mixed with autogenous bone from ramus and/or maxillary tuberosity(n=13). After 6 months of healing, implant sites were created with 3mm diameter trephine and biopsies taken for histomorphometric analysis. The parameters assessed were area fraction of new bone, graft material and connective tissue. Immediate and 6 months after grafting surgery, and 6 months after implantation, computed tomography (CT) was taken and the sinus graft was evaluated morphometric analysis. After implant installation at the grafted area, the clinical outcome was checked. Results: Histomorphometry was done in ten patients.Bio-$cera^{TM}$ particles were surrounded by newly formed bone. The graft particles and newly formed bone were surrounded by connective tissue including small capillaries in some fields. Imaging processing revealed $24.86{\pm}7.59%$ of new bone, $38.20{\pm}13.19%$ connective tissue, and $36.92{\pm}14.51%$ of remaining Bio-$cera^{TM}$ particles. All grafted sites received an implant, and in all cases sufficient bone height was achieved to install implants. The increase in ridge height was about $15.9{\pm}1.8mm$ immediately after operation (from 13mm to 19mm). After 6 months operation, ridge height was reduced about $11.5{\pm}13.5%$. After implant installation, average marginal bone loss after 6 months was $0.3{\pm}0.15mm$. Conclusion: Bio-$cera^{TM}$ showed new bone formation similar with Bio-$Oss^{(R)}$ histomorphometrically and appeared to be an effective bone substitute in maxillary sinus augmentation procedure with the residual bone height from 2 to 6mm.

Plant Physiological Responses in Relation to Temperature, Light Intensity, and CO2 Concentration for the Selection of Efficient Foliage Plants on the Improvement of Indoor Environment (실내 환경 개선에 적합한 식물 선발을 위한 온도, 광도, 이산화탄소 농도에 따른 관엽식물들의 생리적 반응)

  • Park, Sin-Ae;Kim, Min-Gi;Yoo, Mung-Hwa;Oh, Myung-Min;Son, Ki-Cheol
    • Horticultural Science & Technology
    • /
    • v.28 no.6
    • /
    • pp.928-936
    • /
    • 2010
  • This study was conducted to select efficient foliage plants for improving indoor environment conditions through the investigation of physiological responses including photosynthetic rate according to temperature, light intensity, and $CO_2$ level. Eight popular foliage plants used in this study were $Hedera$ $helix$ L., $Cissus$ $rhombifolia$ Vahl, $Ficus$ $benjamina$ L. 'Hawaii', $Syngonium$ $podophyllum$ Schott 'Albo-Virens', $Dieffenbachia$ $sp.$ 'Marrianne', $Pachira$ $aquatica$ Aubl., $Spathiphyllum$ $wallisii$ Regel, and $Scindapsus$ $aureus$ Engler. Photosynthetic rate and transpiration rate of the plants subjected to various light intensities (0, 25, 50, 75, 100, 150, 300, and $600{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ PPFD), $CO_2$ levels (0, 50, 100, 200, 400, 700, and $1,000{\mu}molCO_2{\cdot}mol^{-1}$), and two different temperatures (16 and $22^{\circ}C$) were measured. In addition, various parameters in relation to photosynthesis were calculated from the measured data. As a result, the patterns of photosynthesis varied among 8 foliage plants according to light intensity, $CO_2$ level, and temperature. Most foliage plants except $Dieffenbachia$ had high levels of apparent quantum yield, which represents the photosynthetic rate under low light intensity (PPFD $0-100{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$). $Hedera$ $helix$, $Ficus$ $benjamina$, $Pachira$ $aquatica$, and $Spathiphyllum$ $wallisii$ exposed to high light intensity (PPFD $200-600{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$) showed high levels of photosynthesis. $Cissus$ $rhombifolia$ and $Syngonium$ $podophyllum$ were low in $CO_2$ fixation efficiency compared to the other 6 foliage indoor plants. $Hedera$ $helix$ and $Spathiphyllum$ $wallisii$ showed high photosynthetic rate under high $CO_2$ level and vigorous photosynthesis was also observed in $Ficus$ $benjamina$ and $Pachira$ $aquatica$ grown under $22^{\circ}C$. Considering characteristics of indoor environment such as low light, high $CO_2$ level, and low relative humidity, therefore, $Hedera$ $helix$, $Spathiphyllum$ $wallisii$, $Ficus$ $benjamina$, and $Pachira$ $aquatica$ were efficient indoor foliage plants to improve indoor environmental conditions.

Validation of Satellite SMAP Sea Surface Salinity using Ieodo Ocean Research Station Data (이어도 해양과학기지 자료를 활용한 SMAP 인공위성 염분 검증)

  • Park, Jae-Jin;Park, Kyung-Ae;Kim, Hee-Young;Lee, Eunil;Byun, Do-Seong;Jeong, Kwang-Yeong
    • Journal of the Korean earth science society
    • /
    • v.41 no.5
    • /
    • pp.469-477
    • /
    • 2020
  • Salinity is not only an important variable that determines the density of the ocean but also one of the main parameters representing the global water cycle. Ocean salinity observations have been mainly conducted using ships, Argo floats, and buoys. Since the first satellite salinity was launched in 2009, it is also possible to observe sea surface salinity in the global ocean using satellite salinity data. However, the satellite salinity data contain various errors, it is necessary to validate its accuracy before applying it as research data. In this study, the salinity accuracy between the Soil Moisture Active Passive (SMAP) satellite salinity data and the in-situ salinity data provided by the Ieodo ocean research station was evaluated, and the error characteristics were analyzed from April 2015 to August 2020. As a result, a total of 314 match-up points were produced, and the root mean square error (RMSE) and mean bias of salinity were 1.79 and 0.91 psu, respectively. Overall, the satellite salinity was overestimated compare to the in-situ salinity. Satellite salinity is dependent on various marine environmental factors such as season, sea surface temperature (SST), and wind speed. In summer, the difference between the satellite salinity and the in-situ salinity was less than 0.18 psu. This means that the accuracy of satellite salinity increases at high SST rather than at low SST. This accuracy was affected by the sensitivity of the sensor. Likewise, the error was reduced at wind speeds greater than 5 m s-1. This study suggests that satellite-derived salinity data should be used in coastal areas for limited use by checking if they are suitable for specific research purposes.

STRAIN AND TEMPERATURE CHANGES DURING THE POLYMERIZATION OF AUTOPOLYMERIZING ACRYLIC RESINS

  • Ahn Hyung-Jun;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.709-734
    • /
    • 2001
  • The aims of this experiment were to investigate the strain and temperature changes simultaneously within autopolymerzing acrylic resin specimens. A computerized data acquisition system with an electrical resistance strain gauge and a thermocouple was used over time periods up to 180 minutes. The overall strain kinetics, the effects of stress relaxation and additional heat supply during the polymerization were evaluated. Stone mold replicas with an inner butt-joint rectangular cavity ($40.0{\times}25.0mm$, 5.0mm in depth) were duplicated from a brass master mold. A strain gauge (AE-11-S50N-120-EC, CAS Inc., Korea) and a thermocouple were installed within the cavity, which had been connected to a personal computer and a precision signal conditioning amplifier (DA1600 Dynamic Strain Amplifier, CAS Inc., Korea) so that real-time recordings of both polymerization-induced strain and temperature changes were performed. After each of fresh resin mixture was poured into the mold replica, data recording was done up to 180 minutes with three-second interval. Each of two poly(methyl methacrylate) products (Duralay, Vertex) and a vinyl ethyl methacrylate product (Snap) was examined repeatedly ten times. Additionally, removal procedures were done after 15, 30 and 60 minutes from the start of mixing to evaluate the effect of stress relaxation after deflasking. Six specimens for each of nine conditions were examined. After removal from the mold, the specimen continued bench-curing up to 180 minutes. Using a waterbath (Hanau Junior Curing Unit, Model No.76-0, Teledyne Hanau, New York, U.S.A.) with its temperature control maintained at $50^{\circ}C$, heat-soaking procedures with two different durations (15 and 45 minutes) were done to evaluate the effect of additional heat supply on the strain and temperature changes within the specimen during the polymerization. Five specimens for each of six conditions were examined. Within the parameters of this study the following results were drawn: 1. The mean shrinkage strains reached $-3095{\mu}{\epsilon},\;-1796{\mu}{\epsilon}$ and $-2959{\mu}{\epsilon}$ for Duralay, Snap and Vertex, respectively. The mean maximum temperature rise reached $56.7^{\circ}C,\;41.3^{\circ}C$ and $56.1^{\circ}C$ for Duralay, Snap, and Vertex, respectively. A vinyl ethyl methacrylate product (Snap) showed significantly less polymerization shrinkage strain (p<0.01) and significantly lower maximum temperature rise (p<0.01) than the other two poly(methyl methacrylate) products (Duralay, Vertex). 2. Mean maximum shrinkage rate for each resin was calculated to $-31.8{\mu}{\epsilon}/sec,\;-15.9{\mu}{\epsilon}/sec$ and $-31.8{\mu}{\epsilon}/sec$ for Duralay, Snap and Vertex, respectively. Snap showed significantly lower maximum shrinkage rate than Duralay and Vertex (p<0.01). 3. From the second experiment, some expansion was observed immediately after removal of specimen from the mold, and the amount of expansion increased as the removal time was delayed. For each removal time, Snap showed significantly less strain changes than the other two poly(methyl methacrylate) products (p<0.05). 4. During the external heat supply for the resins, higher maximum temperature rises were found. Meanwhile, the maximum shrinkage rates were not different from those of room temperature polymerizations. 5. From the third experiment, the external heat supply for the resins during polymerization could temporarily decrease or even reverse shrinkage strains of each material. But, shrinkage re-occurred in the linear nature after completion of heat supply. 6. Linear thermal expansion coefficients obtained from the end of heat supply continuing for an additional 5 minutes, showed that Snap exhibited significantly lower values than the other two poly(methyl methacrylate) products (p<0.01). Moreover, little difference was found between the mean linear thermal expansion coefficients obtained from two different heating durations (p>0.05).

  • PDF

The Heterogeneity of Flow Distribution and Partition Coefficient in [15O-H2O] Myocardium Positron Emission Tomography ([15O-H2O] 심근 양전자 단층 촬영에서 혈류 분포의 비균일성과 분배계수)

  • Ahn, Ji Young;Lee, Dong Soo;Kim, Kyung Min;Jeong, Jae Min;Chung, June-Key;Shin, Seung-Ae;Lee, Myung Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.32-49
    • /
    • 1998
  • For estimation of regional myocardial blood flow with O-15 water PET, a few modifications considering partial volume effect based on single compartment model have been proposed. In this study, we attempted to quantify the degree of heterogeneity and to show the effect of tissue flow heterogeneity on partition coefficient(${\lambda}$) and to find the relation between perfusable tissue index(PTI) and ${\lambda}$ by computer simulation using two modified models. We simulated tissue curves for the regions with homogeneous and heterogeneous blood flow over a various flow range(0.2-4.0ml/g/min). Simulated heterogeneous tissue composed of 4 subregions of the same or different size of block which have different homogeneous flow and different degree of slope of distribution of blood flow. We measured the index representing heterogeneity of distribution of blood flow for each heterogeneous tissue by the constitution heterogeneity(CH). For model I, we assumed that tissue recovery coefficient ($F_{MME}$) was the product of partial volume effect($F_{MMF}$) and PTI. Using model I, PTI, flow, and $F_{MM}$ were estimated. For model II, we assumed that partition coefficient was another variable which could represent tissue characteristics of heterogeneity of flow distribution. Using model II, PTI, flow and ${\lambda}$ were estimated. For the simulated tissue with homogeneous flow, both models gave exactly the same estimates, of three parameters. For the simulated tissue with heterogeneous flow distribution, in model I, flow and $F_{MM}$ were correctly estimated as CH was increased moderately. In model II, flow and ${\lambda}$ were decreased curvi-linearly as CH was increased. The degree of underestimation of ${\lambda}$ obtained using model II, was correlated with CH. The degree of underestimation of flow was dependent on the degree of underestimation of ${\lambda}$. PTI was somewhat overestimated and did not change according to CH. We conclude that estimated ${\lambda}$ reflect the degree of tissue heterogeneity of flow distribution. We could use the degree of underestimation of ${\lambda}$ to find the characteristic heterogeneity of tissue flow and use ${\lambda}$ to recover the underestimated flow.

  • PDF

CHEMICAL DEGRADATION OF LIGHT-CURED DENTAL COMPOSITE RESINS (수종 치과용 광중합형 복합레진의 화학적 분해)

  • Yang, Kuy-Ho;Choi, Nam-Ki;Park, Mi-Ran;Park, Eun-Hae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.403-411
    • /
    • 2001
  • The aim of this study was to evaluate the resistance to degradation of four commercial composite resins in an alkaline solution. The brands studied were Unifil(GC, Japan), Palfique(Tokuyama Japan). Definite$Degussa-H\ddot{u}ls$ AG, Germany). Revolution(Kerr, U.S.A.). Preweighed discs of each brand were exposed 0.1N NaOH solution at $60^{\circ}C$. After 14 days they were removed, neutralized with HCl, washed with water and dried. Resistance to degradation was evaluated on the basis of following parameters: (a) mass loss(%) - determined from pre-and post-exposed specimen weights; (b) Si loss(ppm) - obtained from ICP-AE analysis of solution exposed to specimens; and (c) degradation depth$({\mu}m)$ - measured microscopically (SEM) from polished circular sections of exposed specimens. The results were follows: 1. The mass loss of Unifil was 3.21%, it was the highest of materials. But, there was no significant difference among the materials. 2. The degree of degradation layer depth was $107.69\sim47.40{\mu}m$, the sequence of the degree pf degradation layer depth was in descending order by Unifil, Palfique, Revolution, Definite. There was significant difference among the materials except Palfique and Definite. 3. The Si loss of Paltique was 8940.0ppm, it was the highest. There was significant difference among the materials, except Revolution and Definite(p<0.05). 4. The correlation coefficient between mass loss and degradation depth was relatively high(r = 0.06, p<0.05). 5. There was no significant coefficient correlation between Si loss and mass loss, and/or the degree of degradation layer depth and Si loss. 6. When observed with SEM, destruction of bonding is observed between resin matrix and filler. Above results suggested that the hydrolytic degradation is considered as evaluation factor of composite resins.

  • PDF

Eosinophilic Peritonitis (EP) Complicated with Continuous Ambulatory Peritoneal Dialysis (CAPD) (지속적 외래 복막투석 직후 발생하는 비감염성 호산구성 복막염)

  • Paek Kyung-Hoon;Jeon Yun-Ae;Min Jae-Hong;Park Kyung-Mi;Kim Jung-Su;Ha Il-Soo;Cheong Hae-Il;Choi Yong;Ko Kwang-Wook
    • Childhood Kidney Diseases
    • /
    • v.1 no.2
    • /
    • pp.117-122
    • /
    • 1997
  • Purpose : To clarify the clinical findings, laboratory findings and disease course of EP complicated with CAPD and to find out possible predisposing factors to EP. Methods : The medical records of 34 children who underwent CAPD at our hospital between Jan. '94 and Dec. '96 were retrospectively reviewed. The clinical features and laboratory findings of EP were analyzed, and several parameters were evaluated as predisposing factors of EP. Results : EP developed in 7(21%) out of 34 patients. The major symptom of EP was turbid peritoneal fluid without fever, abdominal pain or disturbance of drainage in all cases. The microbiologic culture studies of the peritoneal fluid resulted negative in all cases. Patients with peripheral blood eosinophilia before insertion of CAPD catheter had higher risk of EP than those without eosinophilia (P=0.002). And peripheral blood eosinophilia, noted after insertion of hemodialysis catheter in cases with previous hemodialysis before CAPD, showed significant correlation with the occurrence of EP (P=0.016), too. However, there was no significant correlation between peripheral blood eosinophilia noted after insertion of CAPD cathter and the occurrence of EP. Identification of eosinophils in peritoneal fluids was more accurate with cytospin analysis. Conclusions : An early and accurate diagnosis of EP in patients with CAPD can prevent unnecessary treatment of antibiotics. Peripheral blood eosinophilia before insertion of CAPD catheter is one of the predisposing factors of EP. And, cytospin analysis of peritoneal fluid is an accurate method for diagnosis of EP.

  • PDF

Japanese Medaka, Oryzias latipes as a Test Animal for Marine Ecotoxicological Evaluation (해양생태독성평가를 위한 표준시험생물로서의 송사리(Oryzias latipes)에 관한 연구)

  • Park Gyung Soo;Yoon Seong Jin;Lee Seung Min;Kim Ae Hyang;Park Soung Yun;Kang Duk Young
    • Korean Journal of Environmental Biology
    • /
    • v.23 no.3 s.59
    • /
    • pp.293-303
    • /
    • 2005
  • Japanese medaka, Oryzias latipes is widely distributed in the North East Asia including Korea, Japan and east China, and commonly used for freshwater toxicity tests and cytotoxicological studies worldwide. In this study, a series of experiments were conducted to identify the potential of the fish as a standard test species for saltwater toxicity evaluation such as marine receiving waters, ocean-dumped materials and sediment pore waters etc. Hatching, growth and mortality rates of the fish were estimated with the wide ranges of salinity from freshwater to seawater (35 psu). Direct exposure of the fertilized eggs in freshwater to the wide ranges of salinity (from 0 to 35 psu) without pre- acclimation to the saltwater revealed no significant differences in hatching rates by salinities (p =0.24). On the other hand, medaka larvae hatched in freshwater and exposed to saltwater directly showed high mortality at > 25 psu treatment groups (p < 0.0001). However, there was no significant difference in mortality of medaka larvae hatched in 13.8 and 14.2 psu at the wide ranges of salinities ($0\~35$ psu). Growth rates of medaka larvae hatched in the above two salinities showed no differences in body length either from 0 to 35 psu treatment groups (p =0.64 for 13.8 psu group and p=0.32 for 14.2 psu group). The number of gill chloride cell in medaka larvae sharply increased when the larvae were exposed to high salinity. Reference tests with zinc chloride revealed 96h $LC_{50}=8.84(7.19\~10.87)mg\;L^{-1}$ using 7~10 day old medaka larvae. These were comparable or better sensitivity in comparison with the other standard test species such as North American sheepshead minnow Cyprinodon variegatus. Based on the results of these experiments, hatching rates and larvalmortality of medaka must be good toxicity parameters for seawater bioassay and the species seems to be a good standard species for both the freshwater and seawater toxicity test.