• Title/Summary/Keyword: AE Measurement

Search Result 373, Processing Time 0.034 seconds

Effects of Cancer-Overcome BeHaS Exercise Program on Shoulder External Rotation, Cancer Coping and Group Cohesion in Mastectomy Patients (암 극복 베하스운동 프로그램이 유방절제술 환자의 어깨 외회전, 암 대처와 집단응집력에 미치는 효과)

  • Kim, Sun Ae;Kim, Jong Im;Park, Sun Young;Min, Shin Hong
    • Journal of muscle and joint health
    • /
    • v.19 no.3
    • /
    • pp.319-328
    • /
    • 2012
  • Purpose: The purpose of this study was to explore effects of a Cancer-overcome BeHaS exercise program that consists of exercise, education, and cognitive supports to improve shoulder external rotation, cancer coping, group cohesion in mastectomy patients. Methods: A one group pre-post test design was used. Thirty mastectomy patients from C Hospital participated in the supervised exercise program once a week for 8 weeks. Data were collected from May to July 2011 using self-administered questionnaires and physical measurement. SPSS/WIN 19.0 was used for the data analysis. Results: The mean age of participants was 53.7 and the mean postoperative period after the surgery was 12.93 months. There were significant differences in the shoulder external rotation, cancer coping, group cohesion between pre and post program. Conclusion: The results showed that cancer-overcome BeHaS exercise program was an effective nursing intervention for improving breast cancer patient's shoulder external rotation, cancer coping and group cohesion.

Properties of Sodium Dodecyl Sulfate / Triton X-100 Mixed Micelle

  • Park, Joon-Woo;Chung, Myung-Ae;Choi, Kyung-Moon
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.5
    • /
    • pp.437-442
    • /
    • 1989
  • The cmc's of sodium dodecyl sulfate (SDS)/Triton X-100 surfactant mixtures were determined by surface tension measurement at various surfactant compositions. The cmc values were lower than those predicted from ideal mixture. The regular solution theory was applied to calculate the interaction parameter, micellar composition, and the activity coefficients of surfactants in the mixed micelle. The interaction parameter (${\beta}$) was - 2.1. The nonideality arised largely from decreased activity of SDS in the mixed micelle. The mean aggregation numbers (${\bar{n}}$) and micropolarity of hydrocarbon region of the mixed micelles were determined by luminescence probe techniques. The total aggregation number (${\bar{n}}_{SDS}+{\bar{n}}_{TX}$) in mixed micelles showed little dependency on the composition of the micelle. The apparent dielectric constant of the hydrocarbon region of the micelle vs micellar composition plot showed positive deviation from linearity. Emission and emission quenching of excited tris(2,2'-bipyridine)ruthenium(Ⅱ) cation, $(Ru(bpy)_3^{2+})$, by methylviologen ($MV^{2+}$) were also investigated in the mixed micellar solutions. The quenching rate was lowest when the mole fraction of SDS in the surfactant mixtures (${\alpha}_{SDS}$) is about 0.25 and highest at ${\alpha}_{SDS}$ = 0.85. This was explained in terms of combined effects of binding of the cations with the micelle and mobility of the bound cations on the surface of the micelles.

Development of an Aging Anxiety Scale for Middle-Aged Women (중년여성의 노화불안 측정도구 개발)

  • Lee, Haejin;You, Mi-Ae
    • Journal of Korean Academy of Nursing
    • /
    • v.49 no.1
    • /
    • pp.14-25
    • /
    • 2019
  • Purpose: This was a methodological study that aimed to develop a measurement scale for aging anxiety among middle-aged women. Methods: In this study, construct factors were extracted, and a conceptual framework was established through an extensive literature review and in-depth interviews with middle-aged women. Under the conceptual framework, 44 preliminary items were constructed, and a preliminary scale of 25 items was completed after two rounds of expert validation and item review. For this study, data were collected from 201 women aged 40~59 years, and the construct validity and reliability of the preliminary scale were verified. Results: To verify the construct validity, exploratory factor analysis was conducted. Four factors containing 19 items were extracted. Concurrent validity of the developed scale was verified with Pearson's correlation analysis. The final scale comprised 4 factors ("Social valueless", "Physical weakness", "Concern about changes in appearance", and "Expectations of old age") and 19 items. The Cronbach's ${\alpha}$ value was .91. Conclusion: The scale for measuring aging anxiety in middle-aged women developed in this study validly reflected the peculiarities of aging anxiety in middle-aged women, who experience many physical, emotional, and social changes. The scale can be said to reflect the cultural background, as it reflected real experiences gained through in-depth interviews with middle-aged women.

The Effect of Arm Extension Patterns of PNF on Muscle Activity of Opposite Lower Extremity (고유수용성신경근촉진법의 팔 폄 패턴이 반대편 다리의 근활성도에 미치는 영향)

  • Kim, Hee-Gwon;Kim, Gyeon;Choi, Jae-Won;Chung, Hyun-Ae
    • PNF and Movement
    • /
    • v.12 no.1
    • /
    • pp.7-12
    • /
    • 2014
  • Purpose: The purpose of this study is to analyze the effect of the arm extension pattern of proprioceptive exercise program on the muscle activity of the opposite lower extremity. Methods: In this study, electromyogram MP150(Biopac system, USA) was applied to 20 healthy male subjects. Arm extension-adduction-internal rotation pattern was applied within initial, mid and end range in sling position and supine position for measurement. And the effect on the activity of rectus femoris and tibialis anterior muscle of the opposite lower extremity was compared and analyzed. Results: The results of this study were summarized as follows: First, there was a statistically significant difference of the activity of the tibialis anterior muscle within the Initial range in sling position and supine position(P<0.05). Second, there was a statistically significant difference of the activity of the tibialis anterior muscle within the end range in sling position and supine position(P<0.05). Conclusion: Rectus femoris and tibialis anterior muscles shows the higher activity in the supine position than in the sling position. Therefore, the supine position is more appropriate than the sling position to make irradiation on lower extremity muscle with the extension pattern.

Implementation of an in vitro exposure system for 28 GHz

  • Lee, Young Seung;Dzagbletey, Philip Ayiku;Chung, Jae-Young;Jeon, Sang Bong;Lee, Ae-Kyoung;Kim, Nam;Song, Seong Jong;Choi, Hyung-Do
    • ETRI Journal
    • /
    • v.42 no.6
    • /
    • pp.837-845
    • /
    • 2020
  • The objective of this study was to implement an in vitro exposure system for 28 GHz to investigate the biological effects of fifth-generation (5G) communication. A signal source of 28 GHz for 5G millimeter-wave (MMW) deployment was developed, followed by a variable attenuator for antenna input power control. A power amplifier was also customized to ensure a maximum output power of 10 W for high-power 28-GHz exposure. A 3-dB uniformity over the 80 mm × 80 mm area that corresponds to four Petri dishes of three-dimensional cell cultures can be obtained using a customized choke-ring-type antenna. An infrared camera is employed for temperature regulation during exposure by adjusting the airflow cooling rate via real-time feedback to the incubator. The reported measurement results confirm that the input power control, uniformity, and temperature regulation for 28-GHz exposure were successfully accomplished, indicating the possibility of a wide application of the implemented in vitro exposure system in the fields of various MMW dose-response studies.

Review of Clinical Researches for Herbal Medicine Treatment on Functional Abdominal Pain in Children. (소아 기능성 복통의 한약치료에 대한 임상연구 동향 - 중의학 논문을 중심으로 -)

  • Park, Se Mi;Yu, Sun Ae
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.35 no.1
    • /
    • pp.104-121
    • /
    • 2021
  • Objectives The purpose of this study is to evaluate the efficacy and safety of herbal medication for the treatment of functional abdominal pain in children by analyzing randomized controlled trials conducted in China. Methods Literatures from China National Knowledge Infrastructure published up to 23 November, 2020 were searched. Then they were collected and analyzed by their publication year, demographic information, treatment methods used, duration of illnesses, duration of treatments, follow-up periods, outcome measurement and adverse events. Results A total of 27 studies were selected for the analysis. In all studies, the total efficacy of the herbal medicine treatment group was reported to be higher than that of the control group. The most frequently used medical herb was Root of Glycyrrhiza uralensis Fischer (甘草). The most frequently used classes of herbal medications are Qi regulating medicine (理氣藥), Qi tonics (補氣藥), Aromatic wet medicine (芳香化濕藥), and Digestant (消食藥). The adverse events rate for the herbal medicine treatment group were significantly lower than those in the Western medicine treatment group. Conclusions This study showed that herbal medicine treatment can be effective and safe option for treating pediatric functional abdominal pain. However, additional well-designed clinical studies are needed to solidify the findings.

Proposal of VO2max estimation formula for elderly men and women using functional performance measurement

  • KWON, Young-Ae;LEE, Wan-Young;KIM, Jun-Su
    • The Korean Journal of Food & Health Convergence
    • /
    • v.8 no.1
    • /
    • pp.21-30
    • /
    • 2022
  • This study proposed a multiple regression equation for predicting VO2max of elderly men and women using functional performance variables required to conduct daily activities. The subjects of this study were 58 elderly men (72.4±5.9 yrs) and 117 elderly women (73.4±4.5 yrs) aged 65-90 who belong to the senior welfare center. The maximal graded exercise test using a cycle ergometer and functional performance representing muscle strength, endurance, static and dynamic flexibility, mobility, and agility were measured. For statistical processing, multiple regression analysis was performed, and the statistical significance level was α = .05. As a result, the VO2max estimation formula for the elderly was 0.419 (standing up and sitting down a chair) + 0.199 (leg endurance against wall) + 5.383, and R2=0.406. In addition, the VO2max estimation formula for elderly women is - 0.737 (standing up from a supine position) - 0.144 (waking around two cones in a figure 8) - 0.135 (%body fat) + 0.042 (one leg balance with eyes open) + 29.395, R2=0.367 was calculated. The conclusion is that if the maximal graded exercise test is not available, it is considered that VO2max of the elderly can be predicted properly by using the estimation formula calculated based on the functional performance variable.

An Empirical Study of the Clinically Reportable Range in Clinical Chemistry (임상보고 가능범위의 실증적 연구)

  • Chang, Sang-Wu;Lee, Sang-Gon;Choi, Ho-Seong;Song, Eun-Young;Park, Yong-Won;Lee, In-Ae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.1
    • /
    • pp.31-36
    • /
    • 2007
  • The purpose of the clinically reportable range (CRR) in clinical chemistry is to estimate linearity in working range. The reportable range includes all results that may be reliably reported, and embraces two types of ranges: the analytical measurement range (AMR) is the range of analyte values that a method can directly measure on the specimen without any dilution, concentration, or other pretreatment not part of the usual assay process. CAP and JCAHO require linearity on analyzers every six months. The clinically reportable range is the range of analyte values that a method can measure, allowing for specimen dilution, concentration, or other pretreatment used to extend the direct analytical measurement range. The AMR cannot exceed the manufacturer's limits. Establishing AMR is easily accomplished with Calibration Verification Assessment and experimental Linearity. For example: The manufacturer states that the limits of the AST on their instrument are 0-1100. The lowest level that could be verified is 2. The upper level is 1241. The verified AMR of the instrument is 2-1241. The lower limit of the range is 2, because that is the lowest level that could be verified by the laboratory. The laboratory could not use the manufacturer's lower limit of 2 because they have not proven that the instrument values below 2 are valid. The upper limit of the range is 1241, because although the lab has shown that the instrument is linear to 1241, the manufacturer does not make that claim. The laboratory needs to demonstrate the accuracy and precision of the analyzer, as well the validation of the patient AMR. Linearity requirements have been eliminated from the CLIA regulations and from the CAP inspection criteria, however, many inspectors continue to feel that linearity studies are a part of good lab practice and should be encouraged. If a lab chooses to continue linearity studies, these studies must fully comply with the calibration/calibration verification requirements of CLIA and/or CAP. The results of lower limit and upper limit of clinically reportable range were total protein (2.1 - 79.9), albumin (1.3 - 39), total bilirubin (0.2 - 106.2), alkaline phosphatase (13 - 6928.2), aspartate aminotransferase (24 - 7446), alanine aminotransferase (13 - 6724.2), gamma glutamyl transpeptidase (16.64 - 9904.2), creatine kinase (15.26 - 4723.8), lactate dehydrogenase (127.66 - 13231.8), creatinine (0.4 - 129.6), blood urea nitrogen (8.67 - 925.8), uric acid (1.6 - 151.2), total cholesterol (48.52 - 3162), triglycerides (36.91 - 3367.8), glucose (31 - 4218), amylase (21 - 6694.2), calcium (3.1 - 118.2), inorganic phosphorus (1.11 - 108), HDL (11.74 - 666), NA (58.3 - 1800), K (1.0 - 69.6), CL (38 - 1230).

  • PDF

Reference Ranges of Microalbumin Using Fasting Urine (Fasting Urine을 사용한 Microalbumin의 참고치에 관한 연구)

  • Kim, Ji-Young;Jin, Kwang-Ho;Bae, Ae-Young;Kim, Ye-Na;Seo, Sang-Won;Lee, Na-Ree;Jeon, Ha-Young;Shin, Sook-Hee
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.3
    • /
    • pp.208-211
    • /
    • 2006
  • Microalbuminuria is most frequently caused by kidney damage from diabetes. Moreover, many other conditions can lead to kidney damage, such as high blood pressure, heart failure, cirrhosis, or systemic lupus erythematosus (SLE). The measurement of the microalbumin in urine may be useful for the early diagnosis or as a predictor of nephropathy in diabetes. The most common method for getting a quantitative measurement of urinary protein relies on a 24-hour urine collection. The result of this method is accurate. But 24hr urine collection is difficult to obtain and variations in volume are frequent. Also the patients complain about urine collection. We tried to measure reference values for microalbumin using fasting urine and compare them with the albumin/creatinine ratio using 24hr urine. The concentrations of microalbumin in fasting urine and 24hr urine were $7.1{\pm}3.8mg/L$, $5.7{\pm}2.9mg/L$ (r=0.61, p=0.27), respectively. The albumin/creatinine ratios using fasting urine and 24hr urine were $8.7{\pm}4.2{\mu}g/mg$, $8.7{\pm}4.0{\mu}g/mg$ (r=0.76, p=0.88), respectively. This study indicated that the measurement of microalbumin in fasting urine was an easy and simple method for early diagnosis or to predict nephropathy in diabetes. Thus, setting up the reference value using fasting urine may be useful in the screening test for the diabetic nephropathy patients instead of using the 24hr albumin excretion rate (AER).

  • PDF

Design and Implementation of Biological Signal Measurement Algorithm for Remote Patient Monitoring based on IoT (IoT기반 원격환자모니터링을 위한 생체신호 측정 알고리즘 설계 및 구현)

  • Jung, Ae-Ran;You, Yong-Min;Lee, Sang-Joon
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.6
    • /
    • pp.957-966
    • /
    • 2018
  • Recently, the demand for remote patient monitoring based on IoT has been increased due to aging population and an increase in single-person household. A non-contact biological signal measurement system using multiple IR-UWB radars for remote patient monitoring is proposed in this paper. To reduce error signals, a multilayer Subtraction algorithm is applied because when the background subtraction algorithm was applied to the biological signal processing, errors occurred such as voltage noise and staircase phenomenon. Therefore, a multilayer background subtraction algorithm is applied to reduce error occurrence. The multilayer background subtraction algorithm extracts the signal by calculating the amount of change between the previous clutter and the current clutter. In this study, the SVD algorithm is used. We applied the improved multilayer background subtraction algorithm to biological signal measurement and computed the respiration rate through Fast Fourier Transform (FFT). To verify the proposed system using IR-UWB radars and multilayer background subtraction algorithm, the respiration rate was measured. The validity of this study was verified by obtaining a precision of 97.36% as a result of a control experiment with Neulog's attachment type breathing apparatus. The implemented algorithm improves the inconvenience of the existing contact wearable method.