• 제목/요약/키워드: AE Count

검색결과 134건 처리시간 0.025초

드릴작업중 발생되는 일방향 적층 CFRP 복합재료의 손상평가 및 AE특성 (The Damage Evaluation and Acoustic Emission Characteristics of the Unidirectional Ply CFRP Composite Materials in a Drilling Procedure)

  • 윤유성;권오헌
    • 동력기계공학회지
    • /
    • 제3권2호
    • /
    • pp.42-50
    • /
    • 1999
  • In recent years, composite materials like CFRP are increasingly used in various fields of engineering because of their unique properties which offer a high strength/density and high modulus/density. When CFRP structures are manufactured in drilling processes which are frequently practiced in an Industry, they bring on the delaminations sometimes. So, acoustic emission(AE) techniques were used for a condition monitoring of the drilling process in CFRP. In this study, the AE from CFRP estimated the delamination which reduces the strength and load carrying capacity under the drilling process and the initial delamination were well caught and measured by a video camera. From the results, it was found the relationships between failure mechanism of CFRP delamination and AE characteristics as like amplitude and count.

  • PDF

엔드밀 가공시 절삭력과 절삭유를 통해 전파된 음향방출을 이용한 공구파손 검출 (Tool fracture detection in end milling using cutting force and acoustic emission propagated through cutting fluid)

  • 맹민재;조성산;정준기
    • 한국정밀공학회지
    • /
    • 제14권11호
    • /
    • pp.163-170
    • /
    • 1997
  • End milling experiments are conducted to investigate characteristics of acoustic emission (AE) and cutting force singals due to tool fracture. The AE signals are obtained with a sensor attached to cutting fluid discharge nozzle. Tool states are identified with scanning electron microscopy and optical microscopy. It is demonstrated that the AE signals provide reliable informations about the cutting processes and tool states. Morever, tool fracture can be detected successfully using both the AE count rate and the standard deviation of principal cutting force.

  • PDF

음향 방출법을 이용한 집중하중을 받는 일방향 섬유 금속 적층판의 손상 해석 (Damage Analysis of Singly Oriented Ply Fiber Metal Laminate under Concentrated Loading Conditions by Using Acoustic Emission)

  • 남현욱;김용환;한경섭
    • Composites Research
    • /
    • 제14권5호
    • /
    • pp.46-53
    • /
    • 2001
  • 집중하중을 받는 일방향 보강(singly oriented ply, SOP) 섬유 금속 적층판(fiber metal laminate, FML)의 손상 거동을 음향 방출법(acoustic emission, AE)을 이용하여 연구하였다. 섬유 방향의 영향을 연구하기 위하여 다양한 섬유 방향을 가지는 SOP FML을 제작하였으며, UTM을 이용하여 압입 하중을 가하였다. 압입 시험 시 발생하는 AE신호는 150kH의 공진 주파수를 가지는 AE센서를 이용하여 측정하였으며, 여기에서 발생된 신호를 하중-변위 선도와 비교하였다. SOP FML의 손상 과정은 균열 개시, 균열 전파, 관통에 따라 3구간으로 나누어 겼다. 균열 개시전까지의 AE 신호의 특성으로 보아 미소 균열이 시편의 하부에서 발생하고 이 균열이 시편의 두께 방향으로 전파되어 섬유 분리를 발생시키는 것으로 생각된다. 발생된 균열은 섬유 방향을 따라 성장하였으며, 이 때 60~80dB의 AE신호들이 발생되었다. 관통이 발생할 때는 80~100dB의 고진폭의 AE신호가 나타나 섬유의 파괴가 발생함을 보였으며, 섬유의 방향이 증가할수록 섬유의 파괴가 많이 발생되었다 누적 AE count선도는 FML의 압입 특성을 잘 나타내어 FML의 특성 변호 예측에 유용하게 사용될 수 있을 것으로 생각된다.

  • PDF

하수 방류수에서 대장균군의 검출방법의 비교 (Comparative Study on Detecting Methods for Total Coliform in Sewage Effluent)

  • 이미애;성일화
    • 한국환경보건학회지
    • /
    • 제33권5호
    • /
    • pp.422-427
    • /
    • 2007
  • The purposes of this study were to investigate the concentration of total coliforms in sewage effluents during the period from August 2004 to October 2005. The removal efficiency range of multi-tube method and plate count method were $31.3{\sim}99.5%$ and $66.8{\sim}99.2%$, respectively. Though a correlation between the multi-tube method and the plate count method in the same sample is low, not only is an experimental procedure very simple, but the time required also is short. The seasonal correlation between methods showed more sensitive spring and summer than autumn and winter. So the study indicated plate count method can be used in rapid and reliance identification of total coliform more than the multi-tube method.

Nasal eosinophilia and eosinophil peroxidase in children and adolescents with rhinitis

  • Choi, Yeonu;Jeon, Haeun;Yang, Eun Ae;Yoon, Jong-Seo;Kim, Hyun Hee
    • Clinical and Experimental Pediatrics
    • /
    • 제62권9호
    • /
    • pp.353-359
    • /
    • 2019
  • Background: Researchers have shown that eosinophil peroxidase (EPO) is a relatively accurate marker of eosinophilia and eosinophil activity. However, its use as a marker of eosinophilic inflammation in nasal secretions is limited because the diagnostic cutoff values of EPO for use as a one-time test for allergic diseases such as allergic rhinitis have not been established. Purpose: To identify the correlation between nasal eosinophil count and EPO in children and adolescents with rhinitis. Methods: We recruited patients <18 years of age with rhinitis for more than 2 weeks or more than 2 episodes a year whose nasal eosinophil and EPO were measured at a single allergy clinic. The eosinophil percentage was calculated by dividing the eosinophil count by the number of total cells under light microscopy at ${\times}1,000$ magnification. EPO and protein were measured from nasal secretions. We retrospectively analyzed the correlation between nasal eosinophils and protein-corrected EPO (EPO/protein) value. Results: Of the 67 patients enrolled, 41 were male (61.2%); the mean age was $8.2{\pm}4.0years$. The median nasal eosinophil count was 1 and percentage was 1%. The median protein-corrected EPO value was $12.5ng/{\mu}g$ (range, $0-31ng/{\mu}g$). There was a statistically significant correlation between eosinophil count and percentage (P<0.001). However, the eosinophil percentage and EPO did not correlate. The eosinophil count and EPO had a statistically significant correlation (P=0.01). The EPO cutoff value examined for nasal eosinophil counts of 2, 5, 10, and 20 was $17.57ng/{\mu}g$ regardless of the reference count. The largest area under the curve value was obtained when the receiver operating characteristic curve was drawn using the eosinophil count of 2. Conclusion: Nasal eosinophil count was significantly associated with protein-corrected EPO.

직접전단시험을 통한 암석 절리의 변형거동 및 미소파괴음 발생에 관한 연구 (Deformation Behaviors and Acoustic Emissions of Rock Joints in Direct Shear)

  • 김태혁;이상돈;이정인
    • 터널과지하공간
    • /
    • 제4권3호
    • /
    • pp.274-286
    • /
    • 1994
  • Direct shear tests were on ducted in a laboratory setting in order to investigate the shear strength and deformation behavior of rock joints. Also, the characteristics of acoustic emissions (AE) during shearing of rock joints were studied. The artificial rock joints were created by splitting the intact blocks of Hwangdeung granites and Iksan marbles. Joint roughness profiles were measured by a profile gage and then digitized by Image analyzer. Roughness profile indices(Rp) of the joints were calculated with these digitized data. Peak shear strength, residual shear strength, shear stiffness and maximum acoustic emission(AE) rate were investigated with joint roughness. The peak shear strenght, the residual shear strength and the shear stiffness were increased as roughness popfile index or normal stress increased in the shear tests of granites. In the tests of marble samples, the shear deformation characteristics were not directly affected by joint roughness. As the result of two directional shear tests, the shear characteristics were varied with shear direction. AE count rates were measured during the shear deformation and the AE signals in several stages of the deformation were analyzed in a frequency domain. The AE rate peaks coincided with the stress drops during the shear deformation of joint. The dominant frequencies of the AE signals were in the vicinity of 100 kHz fo rgranite sample and 900 kHz for marble samples. The distribution of amplitude was dispersed with increasing normal stress.

  • PDF

암석파괴시 발생되는 미세균열의 발생원에 대한 연구 (A Study on Source Mechanisms of Micro-Cracks Induced by Rock Fracture)

  • 김교원
    • 지질공학
    • /
    • 제6권2호
    • /
    • pp.59-64
    • /
    • 1996
  • 암석 시료가 파괴될 때에 발생되는 AE신호는 미세한 균열 발생시의 갑작스런 변형에너지 해바에 기인한다. 압전 압력형 탐촉자와 다채널 기록장치를 이용하여 AE 신호파를 기록하여 분석하므로 외적인 하중조건과 그에 따른 미세균열의 특징에 대하여 연구하였다. 연구결과 미세균열의 체적은 수 $\mu\textrm{m}^3$ 내지 $150,000\mu\textrm{m}^3$로 산출되어서 그 크기가 넓은 범위로 분포하였고 인장형 미세균열이 대체적으로 전단형 보다 큰 체적을 보였다. 또한, 균열원에서의 에너지 강도는 모드 I 하중조건하에서 발생하는 AE 신호가 혼합모드 조건하에서 발생한 신호보다 약 3배정도 크게 나타났으나,시료가 파괴되는 동안 기록된 AE 신호의 숫자는 반대로 모드 I의 경우가 혼합모드의 25%에 불과하였다. 이러한 사실은 같은 크기의 파괴면을 형성하는데 필요한 에너지 요구량이 대체적으로 동일함을 암시하는 것으로 보인다.

  • PDF

음향 방출법에 의한 파괴 인성치 측정 및 파괴 안정성 평가를 위한 연구 (Study of Fracture Toughness Measurement and Fracture Stability Evaluation by Acoustic Emission Method)

  • 이강용;백충헌
    • 대한기계학회논문집
    • /
    • 제13권1호
    • /
    • pp.96-104
    • /
    • 1989
  • 본 연구에서는 AE법에 의해 J$_{IC}$를 결정하는 것은 Takahashi등의 방법을 따르되 AE 실험결과를 토대로 이론을 전개하여 재료의 물성 곡선인 J-R곡선의 실험식과 재료 찢어짐 계수를 계산할 수 있는 실험식을 유도하며, 이렇게 구한 실험식을 불안정 파괴 조건에 적용하여 그 타당성을 검토한다.다.

진공 플라즈마 용사공정에 의한 MCrAlY코팅재의 음향방출 신호 특성 연구 (A Study on Acoustic Emission Characteristics of MCrAlY Coated Material by Vacuum Plasma Spray Process)

  • 박진효;이구현;예경환;김정석;강명창
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.921-924
    • /
    • 2004
  • This paper is to investigate a crack for plasma sprayed MCrAlY coated material by acoustic emission method in 4-point bending test. The CoNiCrAlY is coated on Inconel-718 by vacuum plasma spray process. Micro-hardness measurement was conducted by means of Micro Vickers-hardness indentor. The porosity of coating layer was measured using a SEM and Image Analyzer. AE monitoring system is composed of PICO type sensor, a wide band preamplifier(40dB), a PC and AE DSP(16/32 PAC) board. The AE count, Hit and energy of coating specimens is measured according to coating thickness.

  • PDF

AE를 이용한 회전형 압축기의 이상상태 감시 (The Monitoring of Abnormal Rotary Compressor using Acoustic Emission)

  • 정지홍;이기용;강명창;김정석;이감규;안봉열
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.328-332
    • /
    • 1996
  • The compressor is one of important elements in refrigerator cycle and play an important role of refrigeration efficiency and quality. Therefore it is very important to monitor state of normal and abnormal compressor. In this research, technic of AE is used for monitoring abnormal rotary compressor and an AE parameter which is a most proper parameter to monitor the abnormal state of compressor is determined by signal processing, Finally, the monitoring result of rotary compressor is agreement with the result of life test.

  • PDF