• 제목/요약/키워드: ADC Value

검색결과 86건 처리시간 0.031초

Motor-Driven Power Steering 시스템의 진동 소음 스펙트럼 분석 (Analysis of Vibration Noise Spectrum in Motor-Driven Power Steering System)

  • 박한영;김진영;강준희
    • 센서학회지
    • /
    • 제27권2호
    • /
    • pp.126-131
    • /
    • 2018
  • Unlike the hydraulic power steering (HPS) system, which operates by the high pressure of a fluid obtained from the engine power, the motor-driven power steering (MDPS) system uses an electric motor to steer the wheel without consuming engine power. To steer the wheel with an electric motor, a worm wheel and a worm gear rotating between the steering shaft and motor are required. Any imperfection during the construction of an MDPS system or in a composing part creates noise and vibration, which can be sensed by a driver. To solve the noise and vibration problems, each part must be designed to not resonate with other parts. In this work, we developed the measurement and analysis systems to obtain the noise and the vibration of an automobile MDPS system. A signal analyzer was equipped with a 96 kHz, 24-bit ADC and a 150 MHz digital signal processor. The predetermined threshold value of the vibration in the MDPS system was used to determine the pass/fail, and the results were displayed on the screen. Our system can be used in the fabrication line to swiftly determine any imperfections in the MDPS system construction.

2차 델타 시그마 변조기법을 이용한 고 정밀 및 고 안정 디지털 전자석 전원 장치에 관한 연구 (A Study on High Precision and High Stability Digital Magnet Power Supply Using Second Order Delta-Sigma modulation)

  • 김금수;장길진;김동희
    • 조명전기설비학회논문지
    • /
    • 제29권3호
    • /
    • pp.69-80
    • /
    • 2015
  • This paper is writing about developing magnet power supply. It is very important for power supply to obtain output current in high precision and high stability. As a switching noise and a power noise are the cause of disrupting the stability of output current, to remove these at the front end, low pass filter with 300Hz cutoff frequency is designed and placed. And also to minimize switching noise of the current into magnet and to stop abrupt fluctuations, output filter should be designed, when doing this, we design it by considering load has high value inductance. As power supply demands the stability of less than 5ppm, high precision 24bit(300nV/bit) analog digital converter is needed. As resolving power of 24bit(300nV/bit) analog digital converter is high, it is also very important to design the input stage of analog digital converter. To remove input noise, 4th order low pass filter is composed. Due to the limitation of clock, to minimize quantization error between 15bit DPWM and output of ADC having 24bit resolving power, ${\Sigma}-{\Delta}$ modulation is used and bit contracted DPWM is constituted. And before implementing, to maximize efficiency, simulink is used.

경련 중첩증 환자의 확산 강조 영상 소견: 2 증례 보고 (Diffusion-Weighted Imaging Findings in Patients with Status Epilepticus: Report of Two Cases)

  • Sung Il Jung;Bae Ju Kweon;Keon Ha Kim;Moon Hee Han;Kee-Hyun Chang
    • Investigative Magnetic Resonance Imaging
    • /
    • 제7권1호
    • /
    • pp.56-60
    • /
    • 2003
  • 저자들은 2명의 경련 중첩증 환자들의 확산강조 자기공명영상을 보고하고자 한다. 확산강조 영상은 대뇌 반구에서 세포독성 부종을 시사하는 현성확산계수의 감소가 동반된 국소적 또는 미만성 고신호강도를 보였다. 이러한 고신호강도는 한 환자에서는 양측 측두두정후두엽과 도피질, 다른환자에서는 편측성 측두엽에서 나타났다.

  • PDF

마이크로컴퓨터를 이용한 식품공정의 변수계측 (Measurement of Food Process Variables with Microcomputer)

  • 강준수;서명교;정신교;최종욱
    • 한국식품과학회지
    • /
    • 제24권6호
    • /
    • pp.524-527
    • /
    • 1992
  • 식품가공 공정의 중요변수인 온도, 무게, 상대습도를 측정하기 위하여 16bit 마이크로컴퓨터와 PCL-711S 접속 board로 컴퓨터 시스템을 구성하였다. 자료수집, 공정제어 및 자료분석용 소프트웨어인 PC-LabDAS를 활용하여 센서, 변환기 및 컴퓨터시스템을 작동시켜서 건조 및 저장시 공정변수를 측정하였다. 온도, 무게 및 습도의 측정값과 변환기의 출력값 사이에는 $r^2$가 0.99이상으로 고도의 상관관계를 보였으며 센서의 감응속도도 순간적으로 변하는 미세한 값도 측정할 수 있을 만큼 충분히 빨랐다.

  • PDF

WAVE 핸드오버상에서 수신 신호 세기의 이용 (Usage of RSSI in WAVE Handover)

  • 조웅
    • 한국전자통신학회논문지
    • /
    • 제7권6호
    • /
    • pp.1449-1454
    • /
    • 2012
  • 수신 신호 세기 (RSSI: Received signal strength indicator)는 아날로그-디지털 변환기 입력단에서 수신신호의 세기를 나타낸다. 통신시스템에서 수신 신호 세기는 수신단에서 채널의 상태를 결정하는데 사용된다. 본 논문에서는 핸드오버상에서 실측값을 바탕으로 한 수신 신호 세기의 이용에 대해 알아본다. 먼저 WAVE (Wireless Access in Vehicular Environments)라 일컫어지는 차량통신을 위한 5.9GHz 주파수대에서 RSSI값을 측정한다. 측정된 데이터를 바탕으로 하여 빠른 핸드오버 방식 적용을 위한 수신 신호 세기의 이용에 대해 논의하고, 실제 고속도로 환경에서 RSSI를 이용하여 핸드오버를 적용한다.

자기-자이로 유도 장치를 위한 MEMS형 자이로의 민감도 최적화 (Sensitivity Optimization of MEMS Gyroscope for Magnet-gyro Guidance System)

  • 이인성;김재용;정은국;정경훈;김정민;김성신
    • 로봇학회논문지
    • /
    • 제8권1호
    • /
    • pp.29-36
    • /
    • 2013
  • This paper presents a sensitivity optimization of a MEMS (microelectromechanical systems) gyroscope for a magnet-gyro system. The magnet-gyro system, which is a guidance system for a AGV (automatic or automated guided vehicle), uses a magnet positioning system and a yaw gyroscope. The magnet positioning system measures magnetism of a cylindrical magnet embedded on the floor, and AGV is guided by the motion direction angle calculated with the measured magnetism. If the magnet positioning system does not measure the magnetism, the AGV is guided by using angular velocity measured with the gyroscope. The gyroscope used for the magnet-gyro system is usually MEMS type. Because the MEMS gyroscope is made from the process technology in semiconductor device fabrication, it has small size, low-power and low price. However, the MEMS gyroscope has drift phenomenon caused by noise and calculation error. Precision ADC (analog to digital converter) and accurate sensitivity are needed to minimize the drift phenomenon. Therefore, this paper proposes the method of the sensitivity optimization of the MEMS gyroscope using DEAS (dynamic encoding algorithm for searches). For experiment, we used the AGV mounted with a laser navigation system which is able to measure accurate position of the AGV and compared result by the sensitivity value calculated by the proposed method with result by the sensitivity in specification of the MEMS gyroscope. In experimental results, we verified that the sensitivity value through the proposed method can calculate more accurate motion direction angle of the AGV.

국소 간 병변의 발견: 1.5-T 자기공명영상에서의 자유호흡과 호흡유발 확산강조 영상의 비교 (Detection of Hepatic Lesion: Comparison of Free-Breathing and Respiratory-Triggered Diffusion-Weighted MR imaging on 1.5-T MR system)

  • 박혜영;조현제;김은미;허감;김용훈;이병훈
    • Investigative Magnetic Resonance Imaging
    • /
    • 제15권1호
    • /
    • pp.22-31
    • /
    • 2011
  • 목적: 이 연구의 목적은 간 병변 발견에 있어 1.5-T 자기공명영상에서 자유 호흡 확산강조 영상과 호흡 유발 확산강조 영상의 유용성을 비교하는데 있다. 대상 및 방법: 47명의 환자(평균 57.9세, 남성:여성 = 25:22)가 한번의 간 자기공명 영상검사에서 자유호흡 확산 강조 영상과 호흡유발 확산 강조 영상을 동시에 시행하였다. 이를 두 명의 영상의학과 의사가 호흡유발 이미지 세트(B50, B400, B800 확산강조 영상과 ADC map)와 자유호흡 이미지 세트를 2주간의 시간 간격을 두고 무작위로 후향적 분석을 시행하였다. 영상분석을 위하여 특정영역(ROI)를 설정한 후에 간의 신호대 잡음비 (signal-to-noise ratio, SNR)와 대조도(contrast-to-noise ratio, CNR)를 계산하였다. 결과: 32개의 낭종, 13개의 혈관종, 7개의 간세포암, 6국소 호산구성 간질환, 2개의 전이, 1개의 초점성 결절성 과증식과 글리슨막의 가성지방종을 포함하는 총 62개의 병변이 두 명의 평가자에 의하여 분석되었다. 비록 통계적 유의성을 없었으나, 전체적인 병변 발견의 sensitivity는 호흡유발 확산강조 영상이 [평가자 1:평가자 2, 47/62(75.81%):45/62(72.58%)] 자유호흡 확산강조 영상보다 [44/62(70.97%):41/62(66.13%)] 더 높은 수치를 보였다. 특히 1 cm보다 작은 국소 간 병변 발견의 sensitivity는 호흡유발 확산강조 영상이 [24/30(80%): 21/30(70%)] 지유호흡 확산강조 영상보다 [17/30(56.7%):15/30(50%)] 더 우월하였다. 진단적 정확도활 계산하기 위하여 ROC curve (Az value)를 구하였으며 자유호흡 확산강조 영상과 호흡유발 확산강조 영상간에는 통계적 차이는 없었다. 간의 신호대 잡음비 (SNR)와 대조도 (CNR)는 호흡유발 확산강조 영상이 ($87.6{\pm}41.4$, $41.2{\pm}62.5$) 자유호흡확산강조 영상보다 ($38.8:{\pm}13.6$, $24.8{\pm}36.8$) 높았으며 통계적인 유의성이 있었다. (p value < 0.001). 결론: 1.5-T자기공명 시스템서 1 cm보다 작은 간 병변발견에 있어서 호흡유발 확산강조 영상이 자유호흡 확산강조 영상보다 좋으며 이는 호흡유발 확산강조 영상이 높은 신호대 잡음비 (SNR)와 대조도(CNR)를 보이기 때문이다.

B-values 변환 자기공명영상: 국소 직장암 수술 전 검출을 위한 적합한 b-value 유용성 (Usefulness of High-B-value Diffusion - Weighted MR Imaging for the Pre-operative Detection of Rectal Cancers)

  • 이재승;구은회;이선엽;박철수;최지원
    • 한국콘텐츠학회논문지
    • /
    • 제9권12호
    • /
    • pp.683-690
    • /
    • 2009
  • 본 연구의 목적은 직장암 국소병변의 수술 전 검출을 위한 고 확산경사계수(High-b-values) 자기공명영상의 유용성을 평가하고자 한다. 직장암의 진단을 위하여 확산강조 자기공명영상을 시행한 60명의 환자 중 연령분포는 38 - 78세(평균 60세)였고 남자 40명, 여자가 20명 이었다. 사용된 장비는 1.5 Tesla 자기공명 영상기기(GE, General Electric Medical System, Excite HD)로 사용하였고, 검사 프로토콜은 고속기법 T2, T1강조영상을 얻은 후 정확한 병변 검출을 위하여 같은 위치를 정하여 확산강조영상을 얻었다. 확산강조영상의 b-value$(s/mm^2)$값은 250, 500, 750, 1000, 1500, 2000까지 변화시키면서 얻었다. 영상평가는 정량적 분석방법으로 직장, 방광과 종양간 대조도대 잡음비(rectum, bladder to tumor contrast noise ratio, 이하 CNR)를 GE software Functool tool을 사용하여 비교분석 하였고. 정성적 분석방법은 영상내의 인공물의 유무, 병변의 명확성, 직장벽 구분을 기준으로 네 명의 경험 있는 영상의학과 의사와 세 명의 방사선사가 영상을 분석하였다. 영상의 유의성 평가는 각 b-values 값에 대하여 ANOVA 검증과 Freedman 검증을 이용하여 분석하였다(p<0.05). 정량적 분석결과는 b-values 값 중 1000에서 직장, 종양의 평균 대조도대잡음비는 27.21, 24.44로 가장 높았고(p<0.05), 이때 확산계수는 $0.73\times10^{-3}$이었다. 정성적 분석결과로서, 병변의 명확성과 직장벽 구분은 $4.0\pm0.14$, $4.4\pm0.16$로 1000 값에서 가장 높았으며, 인공물유무는 $4.8\pm0.25$로 2000 값에서 높은 결과 이었다(p<0.05). 결론적으로, 확산강조영상은 수술 전 직장암 환자의 병변 검출에 유용성 있는 정보를 제공해 주었으며, 정확한 종괴의 발견을 위해는 고 확산경사계수 값 1000 영상이 가장 우수한 확산경사계수 값 이었다.

디지털방사선촬영술을 이용한 인접면 치아우식증 진단에 관한 실험적 연구 (A STUDY ON THE ARTIFICIAL INTERPROXIMAL CARIES DETECTION WITH THE DIGITAL RADIOGRAPHY)

  • 권기정;황의환;이상래
    • 치과방사선
    • /
    • 제24권1호
    • /
    • pp.85-94
    • /
    • 1994
  • The purposes of this study were clinical comparison and evaluation between digital radiography and conventional radiography for the detection of artificial interproximal caries. Four freshly extracted, unrestored posterior teeth were obtained and caries was simulated by drilling semicircled defects with variable size at the interproximal surface of each tooth. The experiments were performed with IBM-PC/32 bit-DX compatible, video camera(VM-S8200, Hitachi Co., Japan), and color monitor(Multisync 3D, NEC, Japan). Sylvia Image Capture Board for the ADC(analog to digital converter) was used, and spatial resolution was 512 × 480 with 256 gray levels. The obtained results were as follows: 1. At the condition of under exposure, the radiographs were superior to the digital images in readability. Also, as the size of the artificial lesion was increased, readability of the radiographs was elevated. 2. The digital images were superior to the radiographs in readability especially under over exsposure. 3. As the exposure time and size of lesion was increased, the gray level of region of interest of the digital image was decreased proportionally. 4. As the F-value of average gray level of region of interest at individual exposure time and size of lesion, gray level of the all lesion sizes was decreased in comparison with that of the normal enamel.

  • PDF

센서 기반 헤모글로빈의 산소 포화도 측정을 위한 아날로그 프런트 엔드 설계 기술 및 방법 (Analog Front-End Design Techniques and Method for Saturation of Hemoglobin with Oxygen Sensor)

  • 박세진;이호규;박종선;김철우
    • 전기전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.172-178
    • /
    • 2014
  • 이 논문은 산소 포화도 측정을 위하여 설계되는 아날로그 프런트 엔드의 설계 기술 및 디자인 방법에 관한 것이다. 센서로부터 출력되는 데이터를 이용하여 산소포화도를 계산하기 위해서는 센서의 포토다이오드에서 흘려주는 전류 데이터를 전압 데이터로 바꿔주는 것이 필요하다. 설계된 아날로그 프런트 엔드는 센서로부터 출력되는 전류 데이터를 여러 가지 전압 이득을 가지는 형태로 후방의 아날로그 디지털 변환기에 전압을 전달하는 역할을 한다. 설계된 회로는 $0.11{\mu}m$ CMOS공정을 이용하여 설계되었으며, $0.174mm^2$의 면적을 차지한다.