• 제목/요약/키워드: ADC Value

검색결과 89건 처리시간 0.022초

Background Breast Parenchymal Signal During Menstrual Cycle on Diffusion-Weighted MRI: A Prospective Study in Healthy Premenopausal Women

  • Yeon Soo Kim;Bo La Yun;A Jung Chu;Su Hyun Lee;Hee Jung Shin;Sun Mi Kim;Mijung Jang;Sung Ui Shin;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • 제25권6호
    • /
    • pp.511-517
    • /
    • 2024
  • Objective: To prospectively investigate the influence of the menstrual cycle on the background parenchymal signal (BPS) and apparent diffusion coefficient (ADC) of the breast on diffusion-weighted MRI (DW-MRI) in healthy premenopausal women. Materials and Methods: Seven healthy premenopausal women (median age, 37 years; range, 33-49 years) with regular menstrual cycles participated in this study. DW-MRI was performed during each of the four phases of the menstrual cycle (four examinations in total). Three radiologists independently assessed the BPS visual grade on images with b-values of 800 sec/mm2 (b800), 1200 sec/mm2 (b1200), and a synthetic 1500 sec/mm2 (sb1500). Additionally, one radiologist conducted a quantitative analysis to measure the BPS volume (%) and ADC values of the BPS (ADCBPS) and fibroglandular tissue (ADCFGT). Changes in the visual grade, BPS volume (%), ADCBPS, and ADCFGT during the menstrual cycle were descriptively analyzed. Results: The visual grade of BPS in seven women varied from mild to marked on b800 and from minimal to moderate on b1200 and sb1500. As the b-value increased, the visual grade of BPS decreased. On b800 and sb1500, two of the seven volunteers showed the highest visual grade in the early follicular phase (EFP). On b1200, three of the seven volunteers showed the highest visual grades in EFP. The BPS volume (%) on b800 and b1200 showed the highest value in three of the six volunteers with dense breasts in EFP. Three of the seven volunteers showed the lowest ADCBPS in the EFP. Four of the seven volunteers showed the highest ADCBPS in the early luteal phase (ELP) and the lowest ADCFGT in the late follicular phase (LFP). Conclusion: Most volunteers did not exhibit specific BPS patterns during their menstrual cycles. However, the highest BPS and lowest ADCBPS were more frequently observed in EFP than in the other menstrual cycle phases, whereas the highest ADCBPS was more common in ELP. The lowest ADCFGT was more frequent in LFP.

전이성 척추암 환자의 확산강조영상 검사 시 조영제 주입 전.후 ADC값의 변화에 대한 고찰 (SNR and ADC Value Change before and after the injection of contrast medium during DWI test on metastatic spinal cancer patients)

  • 김응찬;김기홍;박철수;이선엽;유흥준;조재환;장현철;김보희;한만석
    • 한국방사선학회논문지
    • /
    • 제5권1호
    • /
    • pp.37-49
    • /
    • 2011
  • 전이성 척추암 환자를 대상으로 1.5 T MR 기기에서 조영제 주입 전 후 확산강조영상에서 전이가 된 요추의 신호대 잡음비, 대조도대 잡음비, 현성 확산 계수가 어떤 변화를 나타내는지 알아보고자 하였다. 영상의 정량적 분석에서는 전이성 척추암 그룹의 경우 조영제 주입 전 확산강조영상에서 전이성 척추암이 있는 부위와 척추암이 있는 부위의 위, 아래 척추등 세 부위의 신호대 잡음비는 척추암이 있는 부위에서 낮게 나타났으며 조영제 주입 후 확산강조영상에서는 조영제 주입 전보다 세 부위 모두 신호대 잡음비가 상대적으로 증가하였으며 척추암이 있는 부위의 위, 아래 척추등 두 부위 에서는 대조도대 잡음비가 상대적으로 증가했다. ADC map영상에서는 조영제 주입 전에서 신호대 잡음비는 척추암이 있는 부위에서 높게 나타났으며 조영제 주입 후에서는 조영제 주입 전보다 전이성 척추암이 있는 부위와 척추암이 있는 부위의 위, 아래 척추등 세 부위 모두 신호대 잡음비가 상대적으로 감소했다. ADC map영상에서의 현성 확산 계수는 조영제 주입 전에서 현성 확산 계수는 척추암이 있는 부위에서 낮게 나타났으며 조영제 주입 후에서는 주입 전보다 세 부위 모두 현성 확산 계수가 상대적으로 감소했다. 정상 그룹의 경우 확산강조영상에서 요추체 3, 4, 5번 세 부위 모두 신호대 잡음비가 상대적으로 증가했고 ADC map영상에서는 조영제 주입 후 확산강조영상에서 세 부위 모두 신호대 잡음비가 상대적으로 감소했다. ADC map영상에서의 현성 확산 계수는 세 부위 모두 현성 확산 계수가 상대적으로 감소했다. 영상의 정성적 분석에서 조영제 주입 후 확산강조영상에서 전이성 척추암이 있는 부위의 신호강도가 증가하였고 ADC map영상에서는 신호강도가 감소하였다. 조영제 주입 후 확산강조영상에서 전이성 척추암이 있는 부위와 척추암이 있는 부위의 위, 아래 척추 등 세 부위 모두 신호대 잡음비와 대조도대 잡음비가 증가하고 현성확산계수가 감소하는 결과를 얻었고 조영제 주입 후 확산강조영상이 여러 가지 척추질환으로의 적용에 도움을 줄 것이라 사료된다.

Source Coupled FET Logic을 이용한 4:1 병렬 ADC 설계 (A Circuit Design of 4:1 Parallel ADC Using Source Coupled FET Logic)

  • 윤몽한;임명호;이상원;이형재
    • 한국통신학회논문지
    • /
    • 제15권6호
    • /
    • pp.467-474
    • /
    • 1990
  • 본 연구에서는 기존의 SCFL(Source Coupled FET Logic)회로보다 고속 저전력 특성을 지닌 회로를 설계하였다. 설계된 SCFL을 이용하여 4:1 병렬 A/D 컨버터를 구성, 시뮬레이션 한 결과 비교기(Comparator 혹은 양자화기)는 66MHz 입력신호와 2GHz 샘플링 주파수에서 Integral Nonlinearity는 $\pm$28mV로 한계치 $\pm$68mV 보다 훨씬 작으며, ADC 설계시 150여개의 소자를 줄여 전력소비 0.43mW를 실현케 하였다.

  • PDF

Benign versus Malignant Soft-Tissue Tumors: Differentiation with 3T Magnetic Resonance Image Textural Analysis Including Diffusion-Weighted Imaging

  • Lee, Youngjun;Jee, Won-Hee;Whang, Yoon Sub;Jung, Chan Kwon;Chung, Yang-Guk;Lee, So-Yeon
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권2호
    • /
    • pp.118-128
    • /
    • 2021
  • Purpose: To investigate the value of MR textural analysis, including use of diffusion-weighted imaging (DWI) to differentiate malignant from benign soft-tissue tumors on 3T MRI. Materials and Methods: We enrolled 69 patients (25 men, 44 women, ages 18 to 84 years) with pathologically confirmed soft-tissue tumors (29 benign, 40 malignant) who underwent pre-treatment 3T-MRI. We calculated MR texture, including mean, standard deviation (SD), skewness, kurtosis, mean of positive pixels (MPP), and entropy, according to different spatial-scale factors (SSF, 0, 2, 4, 6) on axial T1- and T2-weighted images (T1WI, T2WI), contrast-enhanced T1WI (CE-T1WI), high b-value DWI (800 sec/mm2), and apparent diffusion coefficient (ADC) map. We used the Mann-Whitney U test, logistic regression, and area under the receiver operating characteristic curve (AUC) for statistical analysis. Results: Malignant soft-tissue tumors had significantly lower mean values of DWI, ADC, T2WI and CE-T1WI, MPP of ADC, and CE-T1WI, but significantly higher kurtosis of DWI, T1WI, and CE-T1WI, and entropy of DWI, ADC, and T2WI than did benign tumors (P < 0.050). In multivariate logistic regression, the mean ADC value (SSF, 6) and kurtosis of CE-T1WI (SSF, 4) were independently associated with malignancy (P ≤ 0.009). A multivariate model of MR features worked well for diagnosis of malignant soft-tissue tumors (AUC, 0.909). Conclusion: Accurate diagnosis could be obtained using MR textural analysis with DWI and CE-T1WI in differentiating benign from malignant soft-tissue tumors.

Prognostic Implications for High Expression of MiR-25 in Lung Adenocarcinomas of Female Non-smokers

  • Xu, Fang-Xiu;Su, Yu-Liang;Zhang, Huan;Kong, Jin-Yu;Yu, Herbert;Qian, Bi-Yun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권3호
    • /
    • pp.1197-1203
    • /
    • 2014
  • Background: Adenocarcinoma (ADC) is the most common histological type of lung cancer and its proportion is rising, especially in Asian non-smoking women. Recent studies suggest miR-25 may have diverse effects on the pathogenesis of different types of cancer. However, the role of miR-25 in lung cancer is still unknown. The aim of this study was to investigate the potential clinical value of miR-25 in non-smoking women with lung ADC. Patients and Methods: Quantitative RT-PCR was performed to evaluate the expression of miR-25 in 100 lung ADC tumor tissues and matched plasma samples and Pearson correlation tests were used to analyze the relationship between values. Associations of miR-25 expression with clinicopathological features were determined using the Student's t-test. To determine prognostic value, overall survival (OS) was evaluated using the Kaplan-Meier method. Univariate and multivariate analyses were performed using the Cox proportional hazard model. Results: Expression of miR-25 in tissue was found to be associated with lymph node metastasis (P=0.021) and disease stage (P=0.012). Moreover, high miR-25 expression was also associated with poorer overall survival of women with lung ADC (P=0.008). Conclusion: Tissue miR-25 expression may be associated with tumor progression and have prognostic implications in female lung ADC patients.

MB-OFDM UWB에서 효율적인 자동 이득 조절 장치 (Automatic Gain Control Algorithms for MB-OFDM UWB System)

  • 홍대기
    • 한국산학기술학회논문지
    • /
    • 제8권6호
    • /
    • pp.1402-1409
    • /
    • 2007
  • 본 논문에서는 시스템 구현에 직접적으로 사용될 수 있는 직교 주파수 분할 다중화 (OFDM : Orthogonal Frequency Division Multiplexing) 통신 시스템을 위한 여러 가지 자동 이득 제어 (AGC : Automatic Gain Control) 알고리듬을 제안하고자 한다. 본 논문에서는 고속 패킷 전송을 위하여 비교적 많은 샘플 수를 갖고 긴 길이의 프리앰블을 반복적으로 사용하는 초 광대역 통신 (UWB : Ultra-Wideband)과 같은 OFDM 시스템의 디지털 수신 신호를 가정한다. 이러한 OFDM 시스템에서는 프리앰블 신호를 아날로그-디지털 변환기 (ADC : Analog-to-Digital Converter)를 통해 디지털 수신 신호로 변환한 후 최대 샘플 값 계수기내 버퍼의 길이만큼 디지털 수신 신호를 저장한다. 이 후 버퍼에 저장된 디지털 수신 신호 중 최대 샘플의 개수를 계산하고 이득 조절 신호 발생기에 저장된 이득 조절 테이블에 따라 이득을 조절하여 ADC 입력단의 전력 레벨을 자동으로 조절한다.

  • PDF

Expandable Flash-Type CMOS Analog-to-Digital Converter for Sensor Signal Processing

  • Oh, Chang-Woo;Choi, Byoung-Soo;Kim, JinTae;Seo, Sang-Ho;Shin, Jang-Kyoo;Choi, Pyung
    • 센서학회지
    • /
    • 제26권3호
    • /
    • pp.155-159
    • /
    • 2017
  • The analog-to-digital converter (ADC) is an important component in various fields of sensor signal processing. This paper presents an expandable flash analog-to-digital converter (E-flash ADC) for sensor signal processing using a comparator, a subtractor, and a multiplexer (MUX). The E-flash ADC was simulated and designed in $0.35-{\mu}m$ standard complementary metal-oxide semiconductor (CMOS) technology. For operating the E-flash ADC, input voltage is supplied to the inputs of the comparator and subtractor. When the input voltage is lower than the reference voltage, it is outputted through the MUX in its original form. When it is higher than the reference voltage, the reference voltage is subtracted from the input value and the resulting voltage is outputted through the MUX. Operation of the MUX is determined by the output of the comparator. Further, the output of the comparator is a digital code. The E-flash ADC can be expanded easily.

디지털 마이크로파 수신기에서의 선형 증폭기와 ADC 접속 해석 (Analysis of the Linear Amplifier/ADC Interface in a Digital Microwave Receiver)

  • 이민혁;김성곤;최희주;변건식
    • 한국항행학회논문지
    • /
    • 제3권1호
    • /
    • pp.52-59
    • /
    • 1999
  • 선형 증폭단, ADC 그리고 디지털 신호 처리기로 이루어진 디지털 광대역 마이크로파 수신기는 시스템의 감도와 동적 범위로 성능 평가를 해석할 수 있다. 시스템의 감도와 동적 범위는 시스템의 이득, 3차 상호변조적과 ADC 특성으로 결정되어지며 선형 증폭단의 설계 방법 또한 중요한 영향을 미친다. 그리고 수신기로 입력되는 두 신호의 주파수가 인접한 경우 디지털 신호 처리기는 두 신호를 분리할 수 있어야 한다. 본 논문에서는 증폭단의 이득을 변화시켜 동적 범위를 측정한 다음, 가장 적절한 감도와 동적 범위를 선택할 수 있는 이득 값을 결정하고, 인접한 두 신호의 분리를 위해 고해상도 스펙트럼 추정법을 사용하였다.

  • PDF

Diffusion-weighted Imaging and Apparent Diffusion Coefficient Maps for the Evaluation of Pyogenic Ventriculitis

  • Kim, Hyeong-Seok;Hong, Jae-Taek;Lee, Sang-Won;Son, Byung-Chul;Sung, Jae-Hoon;Kim, Moon-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권1호
    • /
    • pp.23-27
    • /
    • 2005
  • Objective : The aim of this study is to assess the significance of an apparent diffusion coefficient[ADC] study for diagnosis of ventriculitis. Methods : Seven patients with ventriculitis were enrolled in this study. Diffusion-weighted[DW] magnetic resonance images[MRI] and ADC maps in the dependent intraventricular collection, periventricular white matter and non-dependent cerebrospinal fluid[CSF] were obtained. The images and ADC data from the different lesions were compared. Results : The DW MRI showed marked hyperintensity in the purulent pus lesion, and the corresponding ADC maps revealed prominent hypointensity and restricted ADC values compared with the non-dependent CSF and normal white matter. Conclusion : The decreased ADC value and increased signal intensity of the dependent intraventricular fluid on the DW MRI show restricted water diffusion in the purulent fluid, which is indicative of a pyogenic ventriculitis diagnosis.

특성이 다른 지게차 적재 중량 센서의 초기 값 오차 보정 (Error Calibration of Initial Value of Weight Measuring Sensors with Different Feature of Forklift)

  • 한치문;임춘식;이성렬
    • 한국항행학회논문지
    • /
    • 제23권2호
    • /
    • pp.214-220
    • /
    • 2019
  • 산업현장에서의 안전사고 빈도가 높은 지게차 전복의 주요 원인인 과적을 방지하기 위해 개발된 앵커(anchor) 볼트 형태의 strain 게이지 센서의 초기 값 오차를 보정하는 방법을 제안하였다. Strain 게이지 센서의 초기 값 오차는 앵커 볼트의 물리적이고 기계적 오차와 환경적 문제에기인하는 것을 확인하였다. 이러한 원인들을 제조 공정에서 제거하는 것은 본 연구의 범위를 벗어나는 것이기 때문에 제반 원인들을 고려한 보정 값을 찾고, 이 보정 값으로 strain 게이지 센서부를 구성하는 ADC 모듈의 초기 값을 보정하는 방법을 적용하였다. 보정 값 도출을 위하여 선형 보간법을 채택하였다. 도출한 보정 값을 4개의 strain 게이지 센서에 적용하여 시험한 결과 4개의 센서 모두 실제 중량 값과의 차이가 5% 이내가 되는 것을 확인하였다. 아울러 초기 값 보정 전에는 센서들의 ADC 값과 적재 중량 실제 값의 상관성이 없었던 점도 동시에 해결할 수 있었다.