• 제목/요약/키워드: ACFs

검색결과 749건 처리시간 0.019초

Flap selection for reconstruction of wide palatal defect after cancer surgery

  • Park, Yun Yong;Ahn, Hee Chang;Lee, Jang Hyun;Chang, Jung Woo
    • 대한두개안면성형외과학회지
    • /
    • 제20권1호
    • /
    • pp.17-23
    • /
    • 2019
  • Background: The resection of head and neck cancer can result in postoperative defect. Many patients have difficulty swallowing and masticating, and some have difficulty speaking. Various types of flaps are used for palatal reconstruction, but flap selection remains controversial. Therefore, our study will suggest which flap to choose during palatal reconstruction. Methods: Thirteen patients who underwent palatal reconstruction from 30 January, 1989 to 4 October, 2016 at our institution. Size was classified as small when the width was < $4cm^2$, medium when it was $4-6cm^2$, and large when it was ${\geq}6cm^2$. Based on speech evaluation, the subjects were divided into a normal group and an easily understood group. After surgery, we assessed whether flap selection was appropriate through the evaluation of flap success, complications, and speech evaluation. Results: Defect size ranged from $1.5{\times}2.0cm$ to $5.0{\times}6.0cm$. In four cases, the defect was in the anterior third of the palate, in eight cases it was in the middle, and there was one case of whole palatal defect. There were three small defects, two medium-sized defects, and eight large defects. Latissimus dorsi free flaps were used in six of the eight large defects in the study. Conclusion: The key to successful reconstructive surgery is appropriate selection of the flap with reference to the characteristics of the defect. Depending on the size and location of the defect, the profiles of different flaps should be matched with the recipient from the outset.

Finger reduction of nasal bone fracture under local anesthesia: outcomes and patient reported satisfaction

  • Lee, Young-Jae;Lee, Kyeong-Tae;Pyon, Jai-Kyong
    • 대한두개안면성형외과학회지
    • /
    • 제20권1호
    • /
    • pp.24-30
    • /
    • 2019
  • Background: Closed reduction of the fracture under general or local anesthesia with elevators or forceps is widely used to treat nasal bone fractures. However, operating under general anesthesia increases the risk of morbidity and raises the cost of management. Furthermore, using forceps or elevators may cause undercorrection, new fractures, mucosal damage, and nasal hemorrhage. We therefore performed manual reduction under local anesthesia, using the little finger, to minimize the demerits of treatment under general anesthesia with forceps or elevators and aimed to assess functional and aesthetic outcomes, and patient satisfaction. Methods: Patients who visited the plastic and reconstructive surgery department between November 2016 and November 2017 with nasal bone fractures and treated by a single surgeon were prospectively followed up. Patients with simple unilateral or bilateral nasal bone fractures were treated with bedside finger reduction under local anesthesia and patients with comminuted nasal bone or septal fractures were scheduled for closed reduction under general anesthesia. Results: Of 84 patients, 28 met the inclusion criterion and underwent bedside finger reduction under local anesthesia. Twenty-seven patients (96.4%) were successfully contacted via telephone for survey. Twenty-three (85.2%) showed good and three (11.1%) showed fair results. All 27 patients (100%) were satisfied with their postoperative function and 25 (92.6%) were satisfied with their postoperative aesthetic result. Twenty-five patients (92.6%) preferred the finger reduction method under local anesthesia over closed reduction under general anesthesia. Conclusion: Finger reduction under local anesthesia in patients with mild unilateral or bilateral nasal bone fractures is an easy and efficient procedure with high patient satisfaction and favorable postoperative functional and aesthetic outcomes.

Exclusive tongue tip reconstruction of hemiglossectomy defects using the underrated lateral arm free flap with bilobed design

  • Oh, Jeongseok;Lee, Tae Hyeon;Lee, Jang Hyun;Tae, Kyung;Park, Seong Oh;Ahn, Hee Chang
    • 대한두개안면성형외과학회지
    • /
    • 제20권1호
    • /
    • pp.37-43
    • /
    • 2019
  • Background: Tongue reconstruction is challenging with the unique function and anatomy. Goals for reconstruction differ depending on the extent of reconstruction. Thin and pliable flaps are useful for tongue tip reconstruction, for appearance and mobility. This study reports lateral arm free flap (LAFF) as a safe and optimal option for hemi-tongue reconstruction, especially for tongue tip after hemiglossectomy. Methods: Thirteen LAFFs were performed for hemi-tongue reconstruction after hemiglossectomy from 1995 to 2018. Of the 13 patients, seven were male and six were female, age varying from 24 to 64 years. Results: All flaps healed uneventfully without complications. Donor sites were closed primarily. The recipient vessels for microvascular anastomosis were mainly superior thyroidal artery, external jugular vein. All patients returned to normal diet, with no complaints regarding reconstructed tongue and donor site. Conclusion: The LAFF is hairless, thin (especially with lateral epicondyle approach), and potentially sensate. They are advantageous features for tongue tip and hemi-tongue reconstruction. Donor site sacrifices the inessential posterior radial collateral artery, and the scar is hidden under short sleeve shirts. We believe that LAFF can be considered as the first choice flap for hemitongue reconstruction, over radial forearm free flaps.

Immediate regraft of the remnant skin on the donor site in split-thickness skin grafting

  • Park, Young Ji;Ryu, Woo Sang;Kim, Jun Oh;Kwon, Gyu Hyeon;Kim, Jun Sik;Kim, Nam Gyun;Lee, Kyung Suk
    • 대한두개안면성형외과학회지
    • /
    • 제20권2호
    • /
    • pp.94-100
    • /
    • 2019
  • Background: Skin defects of head and neck need reconstruction using various local flaps. In some cases, surgeons should consider skin graft for large skin defect. It is important to heal skin graft and donor sites. The authors investigated wound healing mechanisms at the donor sites with split-thick-ness skin graft (STSG). In this study, the authors compared two types of immediate regraft including sheets and islands for the donor site after facial skin graft using remnant skin. Methods: The author reviewed 10 patients who underwent STSG, from March 2015 to May 2017, for skin defects in the craniofacial area. The donor site was immediately covered with the two types using remnant skin after harvesting skin onto the recipient site. Depending on the size of the remnant skin, we conducted regraft with the single sheet (n= 5) and island types (n= 5). Results: On postoperative day 1 and 3 months, the scar formation was evaluated using the Patient and Observer Scar Assessment Scale (POSAS) and Vancouver Scar Scale (VSS). Total POSAS and VSS scores for the island type were lower than in single sheet group after 3 months postoperatively. There was significant difference in specific categories of POSAS and VSS. Conclusion: This study showed a reduction in scar formation following immediate regrafting of the remnant skin at the donor site after STSG surgery. Particularly, the island type is useful for clinical application to facilitate healing of donor sites with STSG.

Short-term changes of human acellular dermal matrix (Megaderm) in a mouse model

  • Kim, Yang Seok;Na, Young Cheon;Yoon, Hyun Sik;Huh, Woo Hoe;Kim, Ji Min
    • 대한두개안면성형외과학회지
    • /
    • 제20권1호
    • /
    • pp.10-16
    • /
    • 2019
  • Background: Physicians tend to overcorrect when applying the acellular dermal matrix for reconstructive option because of volume decrement problem after absorption comparing with initial volume. However, there are no studies on the exact volume decrement and absorption rate with commercial products in South Korea. To figure out absorption rate of acellular dermal matrix product in South Korea (Megaderm), authors designed this experiment. Methods: Nine mice were used and randomly divided into three groups by the time with sacrificing. The implant (Megaderm) was tailored to fit a cuboid form ($1.0cm{\times}1.0cm$ in length and width and 2.0 mm in thickness). A skin incision was made at anterior chest with blade #15 scalpel with exposing the pectoralis major muscle. As hydrated Megaderm was located upon the pectoralis major muscle, the skin was sutured with Ethilon #5-0. After the surgical procedure, each animal group was sacrificed at 4, 8, and 12 weeks, respectively, for biopsies and histological analysis of the implants. All samples were stained with routine hematoxylin and eosin staining and Masson's trichrome staining and the thickness were measured. A measurements were analyzed using Friedman test. Statistically, the correlation between thicknesses of Megaderm before and after implantation was analyzed. Results: After sacrificing the animal groups at postoperative 4, 8, 12 weeks, the mean tissue thickness values were $2.10{\pm}1.03mm$, $2.17{\pm}0.21mm$, and $2.40{\pm}0.20mm$ (p= 0.368), respectively. The remaining ratios after absorption comparing with after initial hydrated Megaderm were 82.7%, 85.4%, and 94.5%, respectively. In histopathological findings, neovascularization and density of collagenous fiber was increased with time. Conclusion: Author's hypothesis was absorption rate of implant would be increased over time. But in this experiment, there is no statistical significance between mean absorption thickness of implant and the time (p= 0.368). Also it can be affected by graft site, blood supply, and animals that were used in the experiment.

Usefulness of the orbicularis oculi myocutaneous flap in periorbital reconstruction

  • Kim, Geon Woo;Bae, Yong Chan;Kim, Joo Hyoung;Nam, Su Bong;Kim, Hoon Soo
    • 대한두개안면성형외과학회지
    • /
    • 제19권4호
    • /
    • pp.254-259
    • /
    • 2018
  • Background: The esthetic and functional outcomes of periorbital defect reconstruction are very important because of the complex anatomy and specialized functions of this region. The orbicularis oculi myocutaneous (OOMC) flap is useful for the reconstruction of periorbital defects. But, according to the location and depth of the defects, the reconstruction using OMC flaps with various techniques is rare. The authors have used various kinds of OOMC flaps in various situations and we present an analysis of our experiences. Methods: From November 2001 to July 2017, we used 36 OOMC flaps to reconstruct 30 periorbital defects in 25 patients. We analyzed the cause of the defect, its location, the type of concomitant surgery, the method of flap movement, and complications. Results: Of the 30 defects, basal cell carcinoma was the most common cause, accounting for 20 cases. When the used OOMC flap was classified according to the location of the defects, the switch flap was used in nine cases among 15 defects of lower eyelid, and the V-Y advancement flap was mainly used for other parts. As surgical methods according to the depth of defect were classified, all cases involving the tarsal plate were reconstructed with a composite graft. In case of skin and muscles, they were reconstructed only with OOMC flap or with full-thickness skin graft. Conclusion: The OOMC flap provides good skin quality that is very similar to that of the defect tissue. Depending on the location and depth of the defect, the OOMC flap may be used properly in a variety of ways to achieve good results.

Reconstruction of cutaneous defects of the nasal tip and alar by two different methods

  • Kim, Yong Hun;Yoon, Hyung Woo;Chung, Seum;Chung, Yoon Kyu
    • 대한두개안면성형외과학회지
    • /
    • 제19권4호
    • /
    • pp.260-263
    • /
    • 2018
  • Background: The alar and nasal tip are important subunits of the nose. Determining the optimal procedure for reconstructing a cutaneous defect in a nasal subunit depends on several factors including size, location, and involvement of deep underlying structures. We treated cutaneous defects after tumor ablation in the alar and nasal tip with a local flap, using an S-shaped design and a modified V-Y advancement flap with a croissant shape. Methods: We analyzed 36 patients with skin tumors who underwent flap coverage after tumor ablation. Rotation flaps were used in 26 cases and croissant-shaped V-Y advancement flaps were used in 10 cases. The primary cause of the defects was skin cancer, except for one benign tumor. Results: The mean patient age was 71 years. The size of the defects ranged from $0.49cm^2$ to $3.5cm^2$. No recurrence of skin cancer was noted and all flaps lasted until the end of follow-up. Partial desquamation of the epidermis was noted in one case. The postoperative appearance for most patients was excellent, objectively and subjectively. Conclusion: For cutaneous defects of up to about $4.0cm^2$ of the alar and nasal tip, local flaps using our methods offered a good cosmetic and therapeutic result. The main advantage of our flaps is the minimal dissection required compared to bilobed and other local flap methods. We believe our flaps are a suitable option for alar and nasal tip reconstruction.

Orbital wall restoring surgery with resorbable mesh plate

  • Joo, Jae Doo;Kang, Dong Hee;Kim, Hyon Surk
    • 대한두개안면성형외과학회지
    • /
    • 제19권4호
    • /
    • pp.264-269
    • /
    • 2018
  • Background: Orbital resorbable mesh plates are adequate to use for isolated floor and medial wall fractures with an intact bony buttress, but are not recommended to use for large orbital wall fractures that need load bearing support. The author previously reported an orbital wall restoring surgery that restored the orbital floor to its prior position through the transnasal approach and maintained temporary extraorbital support with a balloon in the maxillary sinus. Extraorbital support could reduce the load applied on the orbital implants in orbital wall restoring surgery and the use of resorbable implants was considered appropriate for the author's orbital wall restoring technique. Methods: A retrospective review was conducted of 31 patients with pure unilateral orbital floor fractures between May 2014 and May 2018. The patients underwent transnasal restoration of the orbital floor through insertion of a resorbable mesh plate and maintenance of temporary balloon support. The surgical results were evaluated by the Hertel scale and a comparison of preoperative and postoperative orbital volume ratio (OVR) values. Results: The OVR decreased significantly, by an average of 6.01% (p<0.05) and the preoperative and postoperative Hertel scale measurements decreased by an average of 0.34 mm with statistical significance (p<0.05). No complications such as buckling or sagging of the implant occurred among the 31 patients. Conclusion: The use of resorbable mesh plate in orbital floor restoration surgery is an effective and safe technique that can reduce implant deformation or complications deriving from the residual permanent implant.

Trigeminal somatosensory evoked potential test as an evaluation tool for infraorbital nerve damage

  • Hong, Woo Taik;Choi, Jin-hee;Kim, Ji Hyun;Kim, Yong Hun;Yang, Chae-Eun;Kim, Jiye;Kim, Sug Won
    • 대한두개안면성형외과학회지
    • /
    • 제20권4호
    • /
    • pp.223-227
    • /
    • 2019
  • Background: Neurosensory changes are frequently observed in the patients with mid-face fractures, and these symptoms are often caused by infraorbital nerve (ION) damage. Although ION damage is a relatively common phenomenon, there are no established and objective methods to evaluate it. The aim of this study was to test whether trigeminal somatosensory evoked potential (TSEP) could be used as a prognostic predictor of ION damage and TSEP testing was an objective method to evaluate ION injury. Methods: In this prospective TSEP study, 48 patients with unilateral mid-face fracture (only unilateral blow out fracture and unilateral zygomaticomaxillary fracture were included) and potential ION damages were enrolled. Both sides of the face were examined with TSEP and the non-traumatized side of the face was used as control. We calculated the latency difference between the affected and the unaffected sides. Results: Twenty-four patients recovered within 3 months, and 21 patients took more than 3 months to recover. The average latency difference between the affected side and unaffected side was 1.4 and 4.1 ms for the group that recovered within 3 months and the group that recovered after 3 months, respectively. Conclusion: Patients who suffered ION damage showed prolonged latency when examined using the TSEP test. TSEP is an effective tool for evaluation of nerve injury and predicting the recovery of patients with ION damage.

Epidemiology of violence in pediatric and adolescent nasal fracture compared with adult nasal fracture: An 8-year study

  • Yu, Hahyun;Jeon, Minseok;Kim, Youngjun;Choi, Youngwoong
    • 대한두개안면성형외과학회지
    • /
    • 제20권4호
    • /
    • pp.228-232
    • /
    • 2019
  • Background: The epidemiology of nasal fractures varies according to factors such as the era and area of the study, as well as the age of the patient. We compared the characteristics and causes of pediatric nasal fractures. Methods: A total of 2,321 patients with nasal fractures from 2010 to 2017 were examined. The patients were divided into age groups using the Korean school system of age classification. The causes of injury were divided into five groups: violence, fall or slip down, sports, road traffic accidents, and others. Fractures were classified using the Stranc and Robertson standard: vector of force and plane of fracture. Results: Violence was the most common cause of nasal fracture in patients older than 12 years. Violence was a significantly less frequent cause among patients younger than 12 years old than among adolescent and adult patients. Nasal fractures due to violence were not observed in patients younger than 10 years. Plane 2 and lateral force fractures were the most common; however, in patients younger than 12 years, frontal force fractures were significantly more frequent than were lateral force fractures. Conclusion: As children may simply be injured due to a fall or slip down, it is important for the parents and guardians to ensure their safety. As they become older, children should abstain from violence and be monitored. It is therefore very important to ensure that the environment is free of violence in order to prevent such injuries.