• Title/Summary/Keyword: ACCURACY

Search Result 34,318, Processing Time 0.057 seconds

Beam Shaping by Independent Jaw Closure in Steveotactic Radiotherapy (정위방사선치료 시 독립턱 부분폐쇄를 이용하는 선량분포개선 방법)

  • Ahn Yong Chan;Cho Byung Chul;Choi Dong Rock;Kim Dae Yong;Huh Seung Jae;Oh Do Hoon;Bae Hoonsik;Yeo In Hwan;Ko Young Eun
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.150-156
    • /
    • 2000
  • Purpose : Stereotactic radiation therapy (SRT) can deliver highly focused radiation to a small and spherical target lesion with very high degree of mechanical accuracy. For non-spherical and large lesions, however, inclusion of the neighboring normal structures within the high dose radiation volume is inevitable in SRT This is to report the beam shaping using the partial closure of the independent jaw in SRT and the verification of dose calculation and the dose display using a home-made soft ware. Materials and Methods : Authors adopted the idea to partially close one or more independent collimator jaw(5) in addition to the circular collimator cones to shield the neighboring normal structures while keeping the target lesion within the radiation beam field at all angles along the arc trajectory. The output factors (OF's) and the tissue-maximum ratios (TMR's) were measured using the micro ion chamber in the water phantom dosimetry system, and were compared with the theoretical calculations. A film dosimetry procedure was peformed to obtain the depth dose profiles at 5 cm, and they were also compared with the theoretical calculations, where the radiation dose would depend on the actual area of irradiation. Authors incorporated this algorithm into the home-made SRT software for the isodose calculation and display, and was tried on an example case with single brain metastasis. The dose-volume histograms (DVH's) of the planning target volume (PTV) and the normal brain derived by the control plan were reciprocally compared with those derived by the plan using the same arc arrangement plus the independent collimator jaw closure. Results : When using 5.0 cm diameter collimator, the measurements of the OF's and the TMR's with one independent jaw set at 30 mm (unblocked), 15.5 mm, 8.6 mm, and 0 mm from th central beam axis showed good correlation to the theoretical calculation within 0.5% and 0.3% error range. The dose profiles at 5 cm depth obtained by the film dosimetry also showed very good correlation to the theoretical calculations. The isodose profiles obtained on the home-made software demonstrated a slightly more conformal dose distribution around the target lesion by using the independent jaw closure, where the DVH's of the PTV were almost equivalent on the two plans, while the DVH's for the normal brain showed that less volume of the normal brain receiving high radiation dose by using this modification than the control plan employing the circular collimator cone only. Conclusions : With the beam shaping modification using the independent jaw closure, authors have realized wider clinical application of SRT with more conformal dose planning. Authors believe that SRT, with beam shaping ideas and efforts, should no longer be limited to the small spherical lesions, but be more widely applied to rather irregularly shaped tumors in the intracranial and the head and neck regions.

  • PDF

Survival Analysis of Patients with Brain Metastsis by Weighting According to the Primary Tumor Oncotype (전이성 뇌종양 환자에서 원발 종양 가중치에 따른 생존율 분석)

  • Gwak, Hee-Keun;Kim, Woo-Chul;Kim, Hun-Jung;Park, Jung-Hoon;Song, Chang-Hoon
    • Radiation Oncology Journal
    • /
    • v.27 no.3
    • /
    • pp.140-144
    • /
    • 2009
  • Purpose: This study was performed to retrospectively analyze patient survival by weighting according to the primary tumor oncotype in 160 patients with brain metastasis and who underwent whole brain radiotherapy. Materials and Methods: A total of 160 metastatic brain cancer patients who were treated with whole brain radiotherapy of 30 Gy between 2002 and 2008 were retrospectively analyzed. The primary tumor oncotype of 20 patients was breast cancer, and that of 103 patients was lung cancer. Except for 18 patients with leptomeningeal seeding, a total of 142 patients were analyzed according to the prognostic factors and the Recursive Partitioning Analysis (RPA) class. Weighted Partitioning Analysis (WPA), with the weighting being done according to the primary tumor oncotype, was performed and the results were correlated with survival and then compared with the RPA Class. Results: The median survival of the patients in RPA Class I (8 patients) was 20.0 months, that for Class II (76 patients) was 10.0 months and that for Class III (58 patients) was 3.0 months (p<0.003). The median survival of patients in WPA Class I (3 patients) was 36 months, that for the patients in Class II (9 patients) was 23.7 months, that for the patients in Class III (70 patients) was 10.9 months and that for the patients in Class IV (60 patients) was 8.6 months (p<0.001). The WPA Class might have more accuracy in assessing survival, and it may be superior to the RPA Class for assessing survival. Conclusion: A new prognostic index, the WPA Class, has more prognostic value than the RPA Class for the treatment of patients with metastatic brain cancer. This WPA Class may be useful to guide the appropriate treatment of metastatic brain lesions.

Study on the Acceptability and Effectiveness of an Oral Contraceptive Among Iud Drop-outs in Rural Korea

  • Yang, J.M.;Bang, S.;Song, S.W.;Youn, B.B.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.1 no.1
    • /
    • pp.51-66
    • /
    • 1968
  • During a period of about one year(November '66 to December '67), the Yonsei University College of Medicine conducted a field trial of the oral contraceptive(Ovulen) in order to study its acceptability and use-effectiveness among IUD drop-outs in Koyang county. We can summarize the outstanding findings from this investigation as follows; 1. 61.4% of the IUD drop-outs interviewed (911 women) wanted to use the pill. Most of the reasons for not wanting to use it(352 women) pertained to either use of other contraceptive methods(98) or subfecundity(150) following IUD terminations. Only 83 out of 911 women gave reasons related to the difficulty of obtaining pills. Therefore, we can state that most IUD drop-outs if still in need of a contraceptive methods are in favor of trying the pill, and especially so if this method is conveniently available. 2. The 467 women or 37% of those who terminated IUD use actually visited the clinic for medical screening, and only 11 of them or 2.4% were rejected because of pregnancy and other medical reasons such as cervical erosion, myoma, breast mass, etc. 5.5% or 25 of the 456 women who received the first cycle did not take a single pill during the study period. 3. When we defined those 431 women who accepted and took one or more tablets we found that women over age 30, with 4 or more children, and/or with a higher educational level were the best prospects for recruitment. 4. In accuracy of use, about two thirds of the users started taking the pill on the 5 th day as directed for the first three cycles, but the percentages rose sharply to about 80% in later cycles. Tardiness in starting pill use in the first cycle may have occurred partly because they had to return to the clinic monthly to get each new cycle. Among acceptors who did not quit between cycles, 80 to 90% were regular users, missing two or less tablets in each cycle. 5) More than 60% of the users felt well and sometimes lost their pre-acceptance symptoms. especially dysmenorrhea. However, 27.4% (58 women) had side effects attributable to the pill compund as nausea, vomiting, indigestion, breast tenderness, decreased lactation or breakthrough bleeding. 25.0% (53 women) also complained of medical diseases or symptoms not related to the pill, especially during the first three cycles. However, as the confidence and experience of the client and the field workers grew, the incidence of unrelated medical complaints quickly fell to a lower level in the later cycles. 6. As of the end of this study, on December 31, 1967, 49.2% (212 women) had discontinued the use of the pill for medical reasons as well as for the non medical reasons. Only one case terminated use due to a pregnancy after taking pills. The cumulative continuation rates (by the life table method), were 58.9%, 51.9%, 41.0% at the end of 3 months, 6 months and one year, respectively. These rates are lower than in the U.S. studies. Even when we add the retaking group to the first segment, the continuation rate goes up only about 5% above the first segment rates mentioned above. Possible explanations are different dosages, the newerness of the method and the use of only one point for pill distribution in the country together with a monthly return for cycle 1, 2, 3, and 4-6.

  • PDF

The Clinical Usefulness of Cystatin C in Evaluating Renal Function in Children with Various Renal Diseases (다양한 신질환을 가진 소아에서 Cystatin C 검사의 임상적 유용성)

  • Kim, Khi-Joo;Kim, Joung-A;Shin, Jae-Il;Hwang, You-Sik;Cheung, Il-Chun;Lim, Jong-Baeck;Lee, Jae-Seung
    • Childhood Kidney Diseases
    • /
    • v.11 no.2
    • /
    • pp.161-167
    • /
    • 2007
  • Purpose : GFR(glomerular filtration rate) is a fundamental parameter in detecting renal impairment and predicts the progression of renal disease. Because serum creatinine has several disadvantages, serum cystatin C has been recently proposed as a new endogenous marker for GFR. We compared serum cystatin C with creatinine and creatinine clearance to investigate the clinical usefulness of cystatin C. Methods : We retrospectively analyzed 46 patients(60 case numbers) who had various renal diseases and classified them into 3 groups according to creatinine clearance(Group 1 : CrCl <40 mL/min/$1.73m^2$, Group 2 : CrCl 40-60 mL/min/$1.73m^2$, Group 3 CrCl >60 mL/min/$1.73m^2$). We measured serum creatinine, cystatin C and creatinine clearance and also analyzed the correlations among them. Results : Serum cystatin C and creatinine showed a similar correlation to creatinine clearance (r=0.685, r=0.640, respectively) and showed similar diagnostic accuracy in detecting decreased GFR(AUC, cystatin C 0.829 vs. creatinine 0.826, P=0.848). Serum cystatin C showed a greater sensitivity for detecting a decreased GFR than creatinine in Group 2 and 3(Group 1 : 100% vs. 100%, Group 2 : 70% vs. 35%, Group 3 : 46% vs. 15%). Conclusions : Serum cystatin C could be a useful endogenous marker for GFR and would be superior to serum creatinine in early detection of renal impairment in pediatric patients with renal diseases.

  • PDF

Quality Assurance of Volumetric Modulated Arc Therapy Using the Dynalog Files (다이나로그 파일을 이용한 부피세기조절회전치료의 정도관리)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Kim, Yon-Lae;Yang, Hyung-jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.577-585
    • /
    • 2016
  • The purpose of this study is to evaluate the accuracy of beam delivery QA software using the MLC dynalog file, about the VMAT plan with AAPM TG-119 protocol. The Clinac iX with a built-in 120 MLC was used to acquire the MLC dynalog file be imported in MobiusFx(MFX). To establish VMAT plan, Oncentra RTP system was used target and organ structures were contoured in Im'RT phantom. For evaluation of dose distribution was evaluated by using gamma index, and the point dose was evaluated by using the CC13 ion chamber in Im'RT phantom. For the evaluation of point dose, the mean of relative error between measured and calculated value was $1.41{\pm}0.92%$(Target) and $0.89{\pm}0.86%$(OAR), the confidence limit were 3.21(96.79%, Target) and 2.58(97.42%, OAR). For the evaluation of dose distribution, in case of $Delta^{4PT}$, the average percentage of passing rate were $99.78{\pm}0.2%$(3%/3 mm), $96.86{\pm}1.76%$(2%/2 mm). In case of MFX, the average percentage of passing rate were $99.90{\pm}0.14%$(3%/3 mm), $97.98{\pm}1.97%$(2%/2 mm), the confidence limits(CL) were in case of $Delta^{4PT}$ 0.62(99.38%, 3%/3 mm), 6.6(93.4%, 2%/2 mm), in case of MFX, 0.38(99.62%, 3%/3 mm), 5.88(94.12%, 2%/2 mm). In this study, we performed VMAT QA method using dynamic MLC log file compare to binary diode array chamber. All analyzed results were satisfied with acceptance criteria based on TG-119 protocol.

Comparison of $^{18}F$ FDG-PET and CT/MRI for the Diagnosis of Cervical Lymph Node Metastasis in Head and Neck Cancer: A Level-by-Level Based Study (두경부암 환자에서 경부 림프절 전이에 대한 $^{18}F$ FDG-PET과 CT/MRI의 진단적 정확도 비교: 림프절군에 따른 연구)

  • Yang, Yoo-Jung;Kim, Jae-Seung;Kim, Sang-Yun;Lee, Ho-Gyu;Nam, Soon-Yul;Choi, Seung-Ho;Ryu, Jin-Sook;Yeo, Jeong-Seok;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.52-61
    • /
    • 2004
  • Purpose: Cervical lymph node metastasis is the most important factor of the prognosis and therapeutic planning in head and neck cancer. With increasing interest of minimally invasive neck surgery, more accurate preoperative assessment of cervical lymph node becomes more essential. We evaluated the diagnostic accuracy of $^{18}F$ FDG-PET in the assessment of lymph node metastasis in patients with primary head and neck cancer and compared the results with those of CT/MRI. Materials and Methods: Thirty-two patients (M/F=27/5, $56{\pm}10yr$) with biopsy proven head and neck cancer (16 supraglottic cancer, 9 tongue cancer, 7 others) underwent FDG-PET and CT/MRI (25/7) within 1 month before neck dissection. Based on lymph node level, the diagnostic sensitivity and specificity of FDG PET and CT/MRI for the metastasis of cervical lymph node were compared. Results: Of 153 lymph node levels dissected in 32 patients, 32 lymph node levels of 19 patients were positive for metastasis by histopatholologic examination. The overall sensitivity and specificity of FDG-PET were 88% (28/32) and 93% (113/121), whereas those of CT/MRI were 56% (18/32) (p=0.002) and 92% (112/121), respectively. The diagnostic sensitivity and specificity of FDG-PET were different according to location of lymph node levels, and those of ipsilateral level 11 were lower than those of other levels. Conclusion: FDG-PET is more sensitive in detecting metastatic cervical lymph node in head and neck cancer than CT/MRI. FDG-PET might be useful in guiding the extent of neck dissection.

Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT (심근관류 SPECT에서 가역적인 병변을 보인 환자의 3차원 심장 SPECT/CTA 퓨전영상의 유용성)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Kang, Won-Jun;Kim, Seong-Min;Won, Kyoung-Sook;Lim, Seok-Tae;Hwang, Kyung-Hoon;Lee, Byeong-Il;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.513-518
    • /
    • 2009
  • Purpose: Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Materials and Methods: Forty-eight patients (M:F=26:22, Age: $63.3{\pm}10.4$ years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Results: Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Conclusion: Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

Usefulness of wearing pocket dosimeter in nuclear medicine (핵의학 영상검사에서 Pocket dosimeter 착용의 유용성 평가)

  • Kim, Young-Bin;Lee, Eun-Ji;Kim, Kun-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.25-28
    • /
    • 2011
  • Purpose: The aim of study is to find accuracy of pocket dosimeter in measuring exposed dose in compared with survey meter and to compare exposed dose according as Nuclear medicine exams. Materials and Method: First, radiation dose to point source(185 MBq,370 MBq, ${\ldots}$, 1665 MBq, 1850 MBq) were measured in using a pocket dosimeter and a survey meter. Second, radiation dose to 12 patients injected $^{18}F$-FDG 370 MBq were measured in using a pocket dosimeter and a survey meter. Third, radiation dose to 10 patients injected $^{99m}Tc$-DPD 925 MBq were measured in using a pocket dosimeter and a surveymeter. Result: The average is $70.12{\pm}39.36{\mu}Sv/h$ in measurement of point source with Surveymeter and $5{\pm}3.06{\mu}Sv$ in measurement of point source with Pocket dosimeter. The average is $25.04{\pm}6.16{\mu}Sv/h$ in measurement of PET/CT patients with Surveymeter and $2.41{\pm}0.51{\mu}Sv$ in measurement of PET/CT with Pocket dosimeter. The average is $8.58{\pm}0.96{\mu}Sv/h$ in measurement of Bone Scan patients with Surveymeter and $1{\mu}Sv$ in measurement of Bone Scan patients with Pocket dosimeter. Significant difference found between Survey meter value and Pocket dosimeter value in all experimentation (p<0.001). Conclusion: Accoring to rusult Wearing Pocket dosimeter is usefulnee in manerage of exposed dose in nucler medicine exams.

  • PDF

Development of Rapid Analytical Method of Forbidden Medicines in Dietary Supplements Using LC-ESI-Tandem MS (LC-ESI-tandem MS를 이용한 기능성표방식품 중 부정유해물질 신속검사체계 개발)

  • Kim, Hee-Yun;Jang, Young-Mi;Joo, Hyun-Jin;Jung, Young-Hyun;Lee, Myoung-Sook;Park, Jong-Seok;Lee, Kwang-Ho;Lee, Hwa-Mi
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.372-379
    • /
    • 2007
  • A high-performance liquid chromatography-electrospray ionization (HPLC-ESI) tandem MS was developed for the rapid and simultaneous determination of forbidden medicines in dietary supplements. Thirteen medicinal components such as PDE-5 inhibitors and their analogues, and the newly identified dimethylsildenafil and xanthoanthrafil, were included in this study. After tentative standardization of molecular ions in both polarities using thirteen references on the mass spectrometer, with ESI-continuous infusion via the syringe pump method, the relative intensity of the ions present in the resulting spectra was quantitatively compared. From the results, the ion mode was selected depending on each reference's characteristics. A HPLC method coupled with the ESI mode was developed considering the matrix effect and interference depending on the type of sample. The validation test of the developed method was followed by carrying out precision, accuracy, recovery, sensitivity and linearity, etc. The method showed sufficiently high sensitivity, reproducibility, and specificity, and produced 4 times faster results when compared with the existing HPLC/UV method for the determination of forbidden compounds in dietary supplements.

Evaluation of Feed Values for Imported Hay Using Near Infrared Reflectance Spectroscopy (근적외선분광법을 이용한 수입 건초의 사료가치 평가)

  • Park, Hyung Soo;Kim, Ji Hye;Choi, Ki Choon;Oh, Mirae;Lee, Ki-Won;Lee, Bae Hun
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.39 no.4
    • /
    • pp.258-263
    • /
    • 2019
  • Near infrared reflectance spectroscopy (NIRS) has become increasingly used as a rapid and accurate method of evaluating some chemical compositions in forages. The objective of this study was to evaluate the potential of NIRS, applied to imported forage, to estimate the moisture and chemical parameters for imported hays. A population of 392 imported hay representing a wide range in chemical parameters was used in this study. Samples of forage were scanned at 1 nm intervals over the wavelength range 680-2500nm and the optical data was recorded as log 1/Reflectance(log 1/R), which scanned in intact fresh condition. The spectral data were regressed against a range of chemical parameters using partial least squares(PLS) multivariate analysis in conjunction with spectral math treatments to reduced the effect of extraneous noise. The optimum calibrations were selected based on the highest coefficients of determination in cross validation(R2) and the lowest standard error of cross-validation(SECV). The results of this study showed that NIRS predicted the chemical parameters with very high degree of accuracy. The R2 and SECV for imported hay calibration were 0.92(SECV 0.61%) for moisture, 0.98(SECV 0.65%) for acid detergent fiber, 0.97(SECV 0.40%) for neutral detergent fiber, 0.99(SECV 0.06%) for crude protein and 0.97(SECV 3.04%) for relative feed value on a dry matter(%), respectively. Results of this experiment showed the possibility of NIRS method to predict the moisture and chemical composition of imported hay in Korea for routine analysis method to evaluate the feed value.