• Title/Summary/Keyword: AC7A

Search Result 880, Processing Time 0.028 seconds

Evaluation of glycerol encapsulated with alginate and alginate-chitosan polymers in gut environment and its resistance to rumen microbial degradation

  • Gawad, Ramadan;Fellner, Vivek
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.1
    • /
    • pp.72-81
    • /
    • 2019
  • Objective: To determine the effect of gut pH and rumen microbial fermentation on glycerol encapsulated in alginate and alginate-chitosan polymers. Methods: Glycerol was encapsulated at 2.5%, 5%, 7.5%, or 10% (w/w) with sodium alginate (A) and alginate-chitosan (AC) polymers. Surface morphology and chemical modifications of the beads were evaluated using scanning electron microscopy and Fourier transform infrared (FTIR) spectra. Encapsulation efficiency was determined at the 5% glycerol inclusion level in two experiments. In experiment 1, 0.5 g of alginate-glycerol (AG) and alginate-chitosan glycerol (ACG) beads were incubated for 2 h at $39^{\circ}C$ in pH 2 buffer followed by 24 h in pH 8 buffer to simulate gastric and intestinal conditions, respectively. In experiment 2, 0.5 g of AG and ACG beads were incubated in pH 6 buffer at $39^{\circ}C$ for 8 h to simulate rumen conditions. All incubations were replicated four times. Free glycerol content was determined using a spectrophotometer and used to assess loading capacity and encapsulation efficiency. An in vitro experiment with mixed cultures of rumen microbes was conducted to determine effect of encapsulation on microbial fermentation. Data were analyzed according to a complete block design using the MIXED procedure of SAS (SAS Institute, Cary, NC, USA). Results: For AG and ACG, loading capacity and efficiency were 64.7%, 74.7%, 70.3%, and 78.1%, respectively. Based on the FTIR spectra and scanning electron microscopy, ACG treatment demonstrated more intense and stronger ionic bonds. At pH 6, 36.1% and 29.7% of glycerol was released from AG and ACG, respectively. At pH 2 minimal glycerol was released but pH 8 resulted in 95.7% and 93.9% of glycerol released from AG and ACG, respectively. In vitro microbial data show reduced (p<0.05) fermentation of encapsulated glycerol after 24 h of incubation. Conclusion: The AC polymer provided greater protection in acidic pH with a gradual release of intact glycerol when exposed to an alkaline pH.

Expected Values for the Analysis of Accommodation and Vergence Dysfunction of Young Adluts (젊은 성인의 조절 및 이향운동 기능장애 분석을 위한 표준 값)

  • Baarg, Saang-Bai
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.127-134
    • /
    • 2008
  • Purpose: The purpose of this study was to determine the expected values of accommodation and vergence system for analysis of binocular vision. Methods: Seventy three healty subjects without past history of eye disease were selected for this study, Patients showing clinical binocular anomalies including manifest squint and intermittent heterotropia were excluded and data was collected on 54 patients(mean age, 25.3${\pm}$2.7 year). Near point of convergence, distance and near phoiras were measured based on objective deviation angle. And then AC/ A ratio, relative accommodation were measured and all of the data were compared with the Morgan's expected values. Results: The values of distance and near heterophoria were 1.24${\pm}$2.72${\Delta}$ and 2.70${\pm}$4.91${\Delta}$ respectively and the gradient AC/A ratio was 3.92${\pm}$2.17${\Delta}$/D which were all about the same compared with the Morgan's expected values. The values of distance negative fusional convergence was same, however, distance positive fusional convergence was 7${\Delta}$ greater than the Morgan's one. There were no significant differences in the range values of both near vergences while the range of distance vergence was relatively larger than the Morgan's one. Positive relative accommodation was +0.37D greater and negative relative accommodation was -0.63D greater than the Morgan's values. Conclusions: The findings in this study appear that the Morgan's expected values have a possibilities of including considerable proximal convergence value. In comparison with Morgan's values, Korean's normal expected values have much different values of especially BO limit, so if the Morgan's values are directly applied to binocular vision analysis for Korean people, it may lead to an inaccurate binocular vision diagnosis. This results can be used to diagnose the accommodation and vergence system of Korean normal young adults.

  • PDF

DECISION OF PROPER PROJECTION ANGLE AND EVALUATION OF REPRODUCIBILITY IN TRANSCRANIAL RADIOGRAPH (악관절규격촬영시 적절한 입사각의 결정 및 재현성의 평가)

  • Ryu Jung-Soo;Choi Soon-Chul;Lee Sang-Han
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.1
    • /
    • pp.99-107
    • /
    • 1991
  • The purpose of this study was to decide the proper projection angle that could avoid the superimposition of the petrous portion of temporal bone and posterior clinoid process in cephalometric lateral and basal view of the 10 dry skulls and to analyze the reproducibility of a modified Accurad-100 head holder device from Denar Co. and a cephalostat head holder in 30 transcranial radiographs of the dry skull. The results were obtained as follows: The vertical angle was 24.5±4.1° and the horizontal angle was 3.0 ±5.7°. The distances between arbitrary 3 points which were on the TMJ area were as follows: AB 16.76±0.27㎜, BC 8.79±0.18㎜ in the transcranial radiographs using modified Accurad-100 head holder, AB 29.03±0.14㎜, AC 19.95±0.24㎜, BC 10.08±0.07㎜ in the transcranial radiographs using cephalostat.

  • PDF

Preventive Effects of Oat Bran Extracts on Rat Colon Carcinogenesis Induced by 1,2-Dimethylhydrazine

  • Park, Hee-Joeng;Kang, Tae-Su;Kim, Kwang-Yup;Woo, Koan-Sik;Kim, Tae-Myoung;Kim, Yun-Bae;Kim, Dae-Joong;Jeong, Heon-Sang
    • Food Science and Biotechnology
    • /
    • v.15 no.6
    • /
    • pp.942-947
    • /
    • 2006
  • The effect of oat bran extracts on the formation of aberrant crypt foci (ACF) in the colon induced by 1,2-dimethylhydrazine (DMH) was studied in F344 male rats. Extracts were prepared using various combinations of temperature (40, 45, 50, 55, or 60$^{\circ}C:\;X_1$), ethanol concentration (0,5, 10, 15, or 20%: $X_2$), and pH (5, 6, 7, 8, or 9: $X_3$). Among the various extracts tested, one ethanol extract (EE; $45^{\circ}C$, 15% ethanol at pH 6) and one water extract (WE; $50^{\circ}C$ at pH 5) were selected based on their in vitro antitumor activity. The animals were fed with basal diet alone or basal diet supplemented with 0.25 or 0.5% of EE or WE for 6 weeks. During the initial 2 weeks of the 6-week test period, the rats were subcutaneously injected with DMH (30 mg/kg) 4 times for the induction of ACF. DMH induced an average of 322.7 and 142.9 aberrant crypts (AC) and ACF, respectively. A low dose (0.25%) of EE (containing 38.3% ${\beta}$-glucan) and WE (containing 22.8% ${\beta}$-glucan) greatly reduced the numbers of DMH-induced AC and ACF. Significantly, ACF consisting of more than 3 AC were reduced by half in which the effect of EE, containing a higher concentration of ${\beta}$-glucan, was superior to that of WE. These results demonstrate that oat bran extracts may confer protection against colon carcinogenesis.

A Study on the Narrow Erase Method of Surface Discharge AC PDP (면방전 AC PDP에서 세폭소거 방식에 관한 연구)

  • 안양기;윤동한
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.6
    • /
    • pp.39-47
    • /
    • 2003
  • This paper proposes the new narrow erase method to erase wall charges formed in an AC plasma display panel (PDP) cell. In the Proposed method, sustain switching timing is adjusted for inducing a weak discharge. Then, after the narrow erase, tile voltage of the X electrode is set to differ from that of the Y electrode. For the proposed method, the measured maximum address voltage margin was 38.3V at Y_Reset voltage of 100V and sustain voltage of 180∼185V. However, for the prior method, in which the X and Y electrodes we set to be of equal voltage after the narrow erase, the measured maximum address voltage margin was 31.3V at Y_Reset voltage of 150V and sustain voltage of 180V. This result shows that the measured maximum voltage margin for the proposed method is greater than that for the prior method by ∼7V(22%).

The Characteristics of Ozone Generation Synergy Effect for 3 Electrode-1 Discharge Gap Silent Discharge Type Ozonizer using Frequency-Vacuum (주파수-진공도를 이용한 3전극-1방전간극 무성방전형 오존발생기의 오존생성 상승 효과 특성)

  • Song, Hyun-Jig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.94-101
    • /
    • 2005
  • The silent discharge type ozonizer with three electrodes(central electrode, internal electrode, and external electrode) and one discharge gap(discharge gap between internal electrode and external electrode) has been designed and manufactured. It is a silent discharge type ozonizer for which the AC high frequency voltages applied to the central electrode within vacuum discharge tube and the internal electrode for which the external electrode is a ground Ozone is generated by silent discharge in discharge gap. At the moment, discharge characteristics and ozone generation characteristics were investigated in accordance with vacuum of discharge tube, frequency of AC power source, discharge power of ozonizer, and quantity of supplied oxygen gas. In consequence, ozone characteristics proportional to vacuum of discharge tube and frequency of AC power source. The maximum value of ozone can be obtained 7,700[ppm], 460[mg/h] and 70[g/kwh].

Prevalence of binocular anomalies in adult Koreans (한국인의 양안 시기능 이상에 관한 고찰)

  • Ryu, Geun Chang;Park, Hyun Ju;Seong, Jeong Sub;Kim, Jai Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.147-154
    • /
    • 2000
  • To describe the prevalence of binocular anomalies in adult Koreans. Patients included were 19 to 40 years of age, 41 males and 60 females and living in Kwang-Ju Korea. Refractive correction was estimated objectively with an autorefractometer and subjectively refined without cycloplegia. Myopia was defined as a refractive error less than -0.50 diopters hyperopia was defined as a refractive error greater than +0.50 diopters. 101 no strabismic patients who had a refractive error and a near lateral phoria(46%) and an AC/A(accommodative convergence/accommodation) anomaly(50.4%). The prevalence of a near vergence anomaly(52.5%) was higher than a near divergence anomaly(55.5%). The prevalence of a positive relative accommodation(PRA) anomaly(61.4%) was higher than a negative relative accommodation(NRA) anomaly(54.5%). According to Morgan's analysis method, patients with vergence anomaly(21.7%) were seen slightly less frequently than those with accommodative interaction anomaly(29.7%). 34.6% of patients had both vergence anomaly and accommodative interaction anomaly. These results indicate that full prescription for a refractive corrections should be considered as these can improve binocular visual function for ametropia.

  • PDF

A Power Losses Analysis of AC Railway Power Feeding Network using Adaptive Voltage Control (능동형 전압제어를 통한 교류 전기철도 급전망에 대한 전력손실 분석)

  • Jung, Hosung;Kim, Hyungchul;Shin, Seongkuen;Kim, Jinho;Yoon, Kiyong;Cho, Yonghyeun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1621-1627
    • /
    • 2013
  • This paper compares power losses between voltage controlled before and after using power conversion device in AC feeding system. For this purpose we present voltage control procedures and criteria and model high speed line and train using PSCAD/EMTDC to compare power losses in various feeding condition. Power losses of the simulation result in power control before and after in single point feeding system was reduced maximum 0.37 MW(23.8 %) and average 0.23 MW(20.5 %) when one vehicle load operates maximum load condition. When three vehicles operate maximum load condition in one feeder section, power losses after voltage control was reduced 1.03 MW(49.5%) compared to before voltage control. And, power loss of parallel feeding system is reduced the average 0.08 MW(7.2 %) compared to the single feeding system. In conclusion, adaptive voltage control method using power conversion device can reduce power losses compared with existing method.

A Study on Long-time Electrical Treeing Deterioration Properties According to High Frequency Voltage of Epoxy Resin (에폭시수지의 고전압 전원주파수 변화에 따른 장시간 전기적 트리잉 열화 특성연구)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1571-1577
    • /
    • 2013
  • Electrical tree structure is one of the most important influencing factors for electrical treeing characteristics in polymers. In this paper, we focused on the structure characteristics of electrical treeing in epoxy resins (original) insulation under different high-frequency voltages (60, 500, 1000Hz). Effects of voltage frequency on the ac electrical treeing phenomena in an epoxy resins were carried out in needle-plate electrode arrangement. To measure the treeing initiation and propagation, and the breakdown rate, constant AC of 10 kV with three different voltage frequencies (60, 500 and 1,000 Hz) was applied to the specimen in needle-plate electrode specimen at $30^{\circ}C$ of insulating oil bath. At 60 Hz, the treeing initiation time was 360 min and the propagation rate was $6.85{\times}10^{-4}mm/min$, and the morphology was dense branch type. As the voltage frequency increased, the treeing initiation time decreased and the propagation rate increased. At 1,000 Hz, the treeing initiation time was 0 min and the propagation rate was $7.81{\times}10^{-2}mm/min$, and the morphology was dense bush type.

A Novel, High-performance Single-phase Voltage Regulator using Common Arm (Common Arm을 이용한 새로운 고성능 단상 전압조정기에 관한 연구)

  • Park, Sung-Jun;Park, Han-woong;Song, Dal-Sub;Lee, Man-Hyung;Kim, Cheul-U
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.7
    • /
    • pp.369-375
    • /
    • 1999
  • This paper presents the novel low-performance single-phase voltage regulator which has common arm between the AC/DC and DC/AC power converters and adopts appropriate switching strategy, resulting in the reduction of the number of switching devices. Moreover, by introducing the method to replace the method to replace the conventional AC condenser in filter circuit with the new low-cost type using two DC condenser, the whole voltage regulator system can be more compact, simpler and less expensive than conventional ones. The fully digital controller is designed using high speed DSP, and the proposed system is validated through the experimental results.

  • PDF