• 제목/요약/키워드: AC-electric load

검색결과 133건 처리시간 0.023초

절연구간운행 고속철도차량 전력품질 특성 분석 (The analysis of power quality characteristics in high speed train through neutral section of catenary system)

  • 홍현표;최의성;이시빈;이희순
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.634-643
    • /
    • 2011
  • The neutral section was installed in order to prevent conflict with different phase angle source in electric railway catenary system. The speed of electric train reduced due to coasting operation by notch off when it passed the neutral section. And, the catenary wire was damaged and the accident might be happened because of the arc generation when the electric train passed the neutral section with notch off condition. The inrush current of main transformer installed tiling train is analyzed during the operation of MCB(main circuit break) passing through the neutral section. The instantaneous waveform of load current were analyzed in case of powering and regenerative braking. Inrush current waveform with run of AC railway train showed that inrush current waveform and harmonics, the inrush current generated from main transformer in train has bad effects on power quality problem. In order to reduce these inrush currents, the MCB is connected when the phase angle of voltage is 90 degree. This paper is to measure inrush current and harmonics in main transformer of high speed train in neutral section of electric railway. This measurement report is used to control minimum inrush current in algorithm and power phase angle.

  • PDF

5상 1.5kW 농형 유도전동기의 운전특성 (Operating Characteristics of Squirrel-Cage Induction Motor of 5-Phase 1.5kW)

  • 김민회;정형우;송현직
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.52-59
    • /
    • 2014
  • This paper presents an improved operating characteristics of squirrel-cage induction motor(IM) for 5-phase 1.5kW, 220V, 60Hz in order to study a polyphase AC machinery that keep hold of advantages more than traditional three-phase a IM, such as reducing a amplitude of torque pulsation, decreasing electric noises, and increasing the reliability. The developed manufacturing motor was necessary to do improvement of speed regulation, efficiency, operating characteristics, and so on at rated load. There are remake a redesigned and distributed stator winding connection without changing the frames of stator and rotor core in previous established the motor by a repeat tests. There are shown a experiments results of no-load test, locked rotor test, operating characteristics at variable load, FFT analysis of harmonics within output voltages and current waveform, decided motor parameters.

A Contactless Power Supply for a DC Power Service

  • Kim, Eun-Soo;Kim, Yoon-Ho
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권4호
    • /
    • pp.483-491
    • /
    • 2012
  • It is expected that, in the future, DC power service will be widely used for photovoltaic home power generation systems, since DC consuming devices are ever increasing. Instead of using multiple converters to convert DC to AC and then AC to DC, the power service could solely be based on DC. This would eliminate the need for converters, reducing the cost, complexity, and possibly increasing the efficiency. However, configuration of direct DC power service with mechanical contacts can cause spark voltage or an electric shock when the switch is turned on and off. To solve these problems, in this paper, a contactless power supply for a DC power service that can transfer electric power produced by photovoltaics to the home electric system using magnetic coupling instead of mechanical contacts has been proposed. The proposed system consists of a ZVS boost converter, a half-bridge LLC resonant converter, and a contactless transformer. This proposed contactless system eliminates the use of DC switches. To reduce the stress and loss of the boost converter switching devices, a lossless snubber with coupled inductor is applied. In this paper, a switching frequency control technique using the contactless voltage sensing circuit is also proposed and implemented for the output voltage control instead of using additional power regulators. Finally, a prototype consisted of 150W boost converter has been designed and built to demonstrate the feasibility of the proposed contactless photovoltaic DC power service. Experimental results show that 74~83% overall system efficiency is obtained for the 10W~80W load.

전기자동차용 전동기/제어기의 시험 방법 (Test method for Motor/controller for Electric Vehicle)

  • 오성철
    • 전력전자학회논문지
    • /
    • 제8권4호
    • /
    • pp.328-335
    • /
    • 2003
  • 본 논문에서는 전기자동차용 전동기/제어기를 시험하기 위한 절차를 제시하였다. 현재 전기자동차용 전동기/제어기의 시험에 관한 국제 규격은 주로 안전 운전을 위한 최소 기준치를 정의하고 있지만 상세한 시험 방법에 대해서는 기술하고 있지 않다. 시험 항목 및 방법을 개발하기 위하여 기존의 선진국 규격에 대하여 전문가들의 의견을 바탕으로 보완 작업을 수행하였다. 개발된 규격에 따라 전동기/제어기의 시험 방법을 제시하였으며 다양한 부하 장치를 사용할 경우의 시험 방법을 제시하였다. 시험 절차는 주로 전동기 제어기 조합시험에 주안점을 두었으며 부하 장치로는 전동기-발전기, 와전류형 엔진 다이나모, 교류 다이나모 등을 사용하였으며 전동기/제어기를 차량에 탑재하지 않은 상태에서 전동기/제어기의 실제 주행모드 운전 특성을 시험하기 위한 방법을 제시하였다.

신재생 에너지원 활용을 위한 어선 전력계통 분석 및 모델링 (Analysis and Modeling of Fishing Boat's Power Network for using Renewable Energy Source)

  • 이상중;이동길;정지훈
    • 전력전자학회논문지
    • /
    • 제21권2호
    • /
    • pp.182-189
    • /
    • 2016
  • A modeling method of electric power network inside a fishing boat less than 5 tons is proposed for its high-energy efficiency with renewable energy sources. The power network inside the fishing boat consists of a diesel engine, a starter motor, an alternator, battery packs, and electric loads, which are connected in parallel. To obtain proper power network model, the voltage -current characteristics of the electric components are considered to develop elaborate electrical models under several load conditions. Measured data of the battery and alternator current include noise. By using an average method, the AC components from the power network of the fishing boat can be reduced, which is verified by KCL rule. Using the proposed power network model, the power generation of the alternator and the reduction of diesel consumption in the boat's engine are predictable under various operating conditions. The validity of the proposed methodology is verified by comparing simulation results with experimental measurements using statistical inferences.

전동차용 접지브러쉬 편중마모에 대한 해석 (Analsis of Preponderant Wear of Earth Brush for an Electrical Multiple Units(EMUs))

  • 박병섭;구정서;김길동
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.356-361
    • /
    • 2005
  • Earth brush for electrical multiple units(EMUs) is a device through which the current of the EMU load's consumed power fed from the DC 1,500V overhead line (or from the AC 25.000V catenary) flows via axle to the rail(ground) and which prevents the electric corrosion of the axle bearings by preventing the current flow to the axle bearings caused by electric potential from the magnetic field when the bearings rotate together with the earthing function when a thunderbolt falls or a surge comes. The earth brush wear rates among cars, however, shows quite differences when the earth brushes after being separated from the holders are measured with vernier callipers every 6 months of maintenance period. Main causes of the earth brush wear are divided as mechanical, electric arc and electrical one, and the factors can be running speed, current, harmonics, connection state. spring tension, earth brush material, lubricant and so on. but only the earth brushes of the motor(M1) car show the highest wear rate and moreover maintenance difficulty occurs because of the wear rate differences among e earth brushes in one holder. The reason for these preponderant wear comes from the design concept of making preponderant current flow to some particular earth brushes and moreover the heat generated by the harmonics when the inverter starts to operate accelerate the wear. By defining these causes through experiments. I hope that the found results would be helpful for the future EMU design, safety, economy and maintenance.

  • PDF

전기철도계통에 순간전압강하 보상장치 적용에 관한 연구 (A Study on the Application of the DVR in AC Electric Traction System)

  • 최준호;김태수;김재철;문승일;남해곤;정일엽;박성우
    • 조명전기설비학회논문지
    • /
    • 제17권6호
    • /
    • pp.95-104
    • /
    • 2003
  • 전기 철도계통은 기존 전력계통과 달리 단상, 대용량 부하로 필연적으로 전압강하, 전압불평형 및 고조파 왜곡 등의 전력품질의 문제가 발생한다. 이러한 문제점 중 상시전압강하는 전력품질의 가중 중요한 요소로서 SVC(Static Var Compensator) 또는 STACOM(Static Compensator)를 설치하여 전압강하를 보상하는 연구가 수행되었다. 또한 순시전압강하는 고속으로 운전중인 철도차량의 제어 및 안전에 상당한 영향을 미칠것으로 예상된다. 따라서 본 논문에서는 AT(Auto Transformer)급전계통에 적용되는 순간전압강하 보상장치에 관한 연구를 수행하였다. 순간전압강하에 의한 철도차량의 과도해석을 위해 전원, 철도급전변압기, AT, 철도선로 및 철도 차량부하를 모델링 하였다. 또한 순간전압강하 발생시 철도차량부하의 과도특성을 분석하였고 이를 보상하기위한 순간전압강하 보상장치 (DVR:Dynamic Voltage Restorer)를 제안하였다. 순간전압강하 보상 시뮬레이션 결과, 순간전압강하 보상장치의 철도급전계통의 적용은 상당히 유용함을 알수있었다.

전압원인버터를 이용한 계통연계형 풍력발전의 출력제어 모의 및 해석 (Modeling and Analysis of Control Scheme for Voltage Source Inverter Based Grid-connection of Wind Turbine)

  • 김슬기;김응상
    • 에너지공학
    • /
    • 제12권2호
    • /
    • pp.154-163
    • /
    • 2003
  • 전력계통에 연계하기 위해서 풍력발전시스템은 계속해서 변하는 풍속에 응동하여 적정한 출력을 계통에 공급할 수 있을 뿐만 아니라, 연계되는 전력계통에서 허용될 수 있는 수준의 주파수와 전압크기를 갖는 출력을 제공할 수 있어야 하며, 이를 위해서는 풍력발전의 적절한 출력제어가 필수적으로 요구된다. 본 연구에서는 동기발전기가 전압원인버터로 구성된 AC-DC-AC 변환부를 거쳐 계통에 접속되는 계통연계형 풍력발전시스템의 출력제어 전략을 소개하며, 이를 전자기 과도현상 해석 프로그램인 PSCAD/EMTDC를 이용하여 모의하고 해석하였다. 블레이드를 통해 입력되는 풍속에 대하여 최대 에너지를 공급할 수 있도록 전압원인버터의 유효전력 출력제어가 이루어지며, 출력단 전압을 일정하게 유지하기 위한 무효전력 출력제어가 행해진다. 또한 60 Hz의 주파수 출력 및 고조파 저감을 위해 SPWM 스위칭 방식을 채택하였다. 풍속의 변동 및 부하의 변동에 대한 풍력발전시스템의 응동특성 및 출력변화를 모의하고 해석한다.

Design and Implementation of Modified Current Source Based Hybrid DC - DC Converters for Electric Vehicle Applications

  • Selvaganapathi, S.;Senthilkumar, A.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권2호
    • /
    • pp.57-68
    • /
    • 2016
  • In this study, we present the modern hybrid system based power generation for electric vehicle applications. We describe the hybrid structure of modified current source based DC - DC converters used to extract the maximum power from Photovoltaic (PV) and Fuel Cell system. Due to reduced dc-link capacitor requirement and higher reliability, the current source inverters (CSI) better compared to the voltage source based inverter. The novel control strategy includes Distributed Maximum Power Point Tracking (DMPPT) for photovoltaic (PV) and fuel cell power generation system. The proposed DC - DC converters have been analyzed in both buck and boost mode of operation under duty cycle 0.5>d, 0.5<d<1 and 0.5<d for capable electric vehicle applications. The proposed topology benefits include one common DC-AC inverter that interposes the generated power to supply the charge for the sharing of load in a system of hybrid supply with photovoltaic panels and fuel cell PEM. An improved control of Direct Torque and Flux Control (DTFC) based induction motor fed by current source converters for electric vehicle.In order to achieve better performance in terms of speed, power and miles per gallon for the expert, to accepting high regenerative braking current as well as persistent high dynamics driving performance is required. A simulation model for the hybrid power generation system based electric vehicle has been developed by using MATLAB/Simulink. The Direct Torque and Flux Control (DTFC) is planned using Xilinx ISE software tool in addition to a Modelsim 6.3 software tool that is used for simulation purposes. The FPGA based pulse generation is used to control the induction motor for electric vehicle applications. FPGA has been implemented, in order to verify the minimal error between the simulation results of MATLAB/Simulink and experimental results.

고효율 오존생기용 고주파 공진형 인버터의 특성 해석 (Analysis of high-frequency resonant Inverter character using efficient ozonizer)

  • 김영훈;황영민;노인배;김영빈;허태원;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.246-248
    • /
    • 2002
  • This paper presents a high-frequency voltage source inverter for silent corona discharge ozonizer application, which is characterized by the power control based on pulse density modulation (PDM). The PDM inverter produces either a square -wave ac-voltage state or a zero-voltage state at its ac terminals to control the average output voltage under constant do voltage and operating frequency. This results in a wide range of power control in the silent corona discharge load with a strong nonlinear characteristics. And proposed addition circuit for maintain discharge on the center of the airgap. In this paper, schemed equivalent electric circuit of the discharge electrode for simulation. Finally, the effectiveness of this discharge tube character of silent corona ozonizer is investigated in the simulation results.

  • PDF